CS Paper Radar

Robustness of Local Energy Markets to Cyberattacks: Case Study of False Data Injection

Mehran Moradi, Reza Zamani, Phil Aupke, Andreas Theocharis, Andreas Kassler

cs.CR ·submitted 2026-09-29 11:34 UTC · v1

Abstract

Market clearing in community-based local energy markets relies on power demand and PV forecasts, making it vulnerable to coordinated false data injection (FDI) attacks. This paper proposes a bilevel optimization framework to identify worst-case bus-level FDI against interconnected multi-community electricity markets within a distribution network. The upper level attacker maximizes physical impact, measured by cumulative voltage deviation, while accounting for detectability. The lower level re-clears the interconnected multi-community markets subject to operational and network constraints. The bilevel model is reformulated as a single-level mixed-integer program through Karush-Kuhn-Tucker conditions and solved using the epsilon constraint method to characterize the trade-off between physical impact and detectability. Case studies on the IEEE 33-bus system with three communities show that even bounded, system-level zero-sum attacks can reshape local trading, reduce voltage security margins, and produce asymmetric community-level market outcomes. The results further show that vulnerability depends strongly on the spatiotemporal placement of falsified data rather than on uniform spreading across buses and time periods.

Closest papers

Nearest neighbours by meaning across the whole index.

Attack-Resiliency Analytics for Wide-Area Control Systems in Smart Grids

eess.SY ·2026-09-29 ·Mohammad Zakaria Haider, Prabin Mali, Nur Imtiazul Haque, Muhammad Nadeem, Sumit Paudyal +1 more
similarity 0.63
Abstract

Wide-area monitoring, protection, and control (WAMPAC) systems damp inter-area oscillations in large interconnected grids, but their reliance on synchronized PMU measurements carried over wide-area networks exposes them to false data injection (FDI) attacks. This paper presents an attack-resiliency analytics framework that formally models the coupled dynamics of the wide-area damping loop, automatic generation control, and the governor and excitation systems, and formulates the optimal stealthy FDI attack as a mixed-integer linear program (MILP). The anomaly detection model (ADM) enters as a replaceable constraint set: either a static bad-data detection (BDD) rule or a boundary learned from benign operation calibrated to a common false-positive rate. On the IEEE 39 and 118 bus systems, with reference dynamics validated on an OPAL-RT hardware-in-the-loop testbed, the optimal attack with wide-area access attains 3.3 and 8.1 times the benign objective and reaches a 0.5Hz frequency excursion more than twice as fast as an attack confined to automatic generation control. Learned boundaries reduce the attack objective by 15.5 55.0% and prevent over-frequency relay trips in all configurations, with feasible stealthy attacks remaining in every case, and residual risk tracks the width of the learned boundary rather than the detector family.

0.31

Adversarially-Informed Node Criticality Identification in Power Grid Measurements

eess.SY math.OC ·2026-08-27 ·Koto Omiloli, Olugbenga Moses Anubi
similarity 0.62
Abstract

Power grid state estimation relies on sensor measurements that are increasingly vulnerable to adversarial corruption in cyberphysical environments, potentially leading to significant deviations in system observations. This motivates the need to identify critical measurement nodes whose compromise results in the most severe system-level impact. However, existing node criticality methods primarily rely on structural or steady-state analyses and do not explicitly account for adversarial effects on system behavior. To address this gap, this paper proposes an adversarially informed framework for identifying critical measurement nodes in linearized power systems. Within this framework, a structured attack generation mechanism is developed to construct stealthy and effective false data injection attacks (FDIAs) against an H-infinity resilient state estimator. Node criticality is then evaluated using coalition-based marginal contributions of compromised sensor subsets, estimated via permutation sampling over a prescribed set of admissible nodes, with the resulting importance scores mapped to the corresponding physical buses. Simulation results on the IEEE 14-bus system show that adversarially identified nodes induce larger deviations in frequency, voltage angle, and net power compared to randomly selected nodes, demonstrating the effectiveness of the proposed framework.

0.23

GRID-MRI: Resilience Assessment of Power Systems under Coordinated Cyber-Physical Attacks

eess.SY cs.CR ·2026-11-12 ·Isaac Ortega Romero, Ioannis Zografopoulos
similarity 0.62
Abstract · IEEE PESGM 2027, 5 pages

The increasing penetration of inverter-based resources and growing cyber-physical interdependencies expose electrical power systems to disturbances that challenge conventional resilience assessments. Existing approaches often evaluate resilience dimensions independently, overlooking the non-additive effects of coordinated disruptions and the influence of exogenous stressors. To address this gap, this paper proposes a Grid Multidimensional Resilience Index (GRID-MRI) that integrates endogenous disruption severity, coordination effects, and climatic and economic-regulatory conditions. The framework quantifies physical, cyber, and operational degradation, identifies interaction effects through counterfactual (i.e., what-if), simulations of individual and coordinated attacks, and incorporates exogenous stressors as scenario-dependent scaling factors. Its application to a modified IEEE 39-bus system under three escalating cyber-physical attack scenarios, informed by the December 2025 Polish cyberattack incident, reveals that coordinated attacks induce system collapse despite stable individual and additive responses. The corresponding resilience losses are 3.72 and 4.09 times their additive estimates, while GRID-MRI increases from 0.062 to 1.188 and reaches 6.081 under additional exogenous stress. These findings demonstrate the limitations of additive assessments and establish a quantitative basis for distinguishing the dominant mechanisms of multidimensional resilience degradation.

0.28

Data4Cyber: Labeled Cyber-Physical Datasets for Distribution-Grid Management Systems Under Representative OT Attacks

cs.CR ·2026-11-10 ·Ömer Sen, Lennart Bader, Marawan Emara, Martin Serror, Benedikt Schwalm +4 more
published similarity 0.61
Abstract

Cyberattacks against power systems increasingly exploit industrial communication and control dependencies arising from distributed energy resources (DER), remote management, and market-based incentives. Progress on intrusion detection is constrained by a lack of public datasets that align operational technology (OT) network telemetry with physical measurements and control context. Data4Cyber is a labeled cyber-physical dataset recorded in a laboratory distribution management system (DMS) for self-consumption optimization with photovoltaic generation, battery storage, controllable loads, and substation metering. It captures synchronized process measurements, controller context, price incentives, and packet captures (Modbus/TCP and MQTT) across one benign baseline and six attack scenarios spanning protocol-semantic Modbus manipulation, man-in-the-middle (MitM) false-data injection, and MQTT price manipulation. Its fixed 1 s time base, phase-resolved labels, and state-oriented representation support temporally blocked stateful-detector evaluation. Baseline results show that high recall alone is insufficient: several detectors achieve sensitivity through alarm saturation. Context-driven attacks require process-aware interpretation rather than single-channel thresholding.

0.63

An Adaptive Cyber-Resilient Framework for P2P Energy Trading under Optimal Stealthy Attacks

eess.SY ·2026-10-10 ·Devangi, Yashasvi Bansal, Ankit Singhal
similarity 0.61
Abstract

The increasing adoption of peer to peer energy trading has enabled prosumers to actively participate in decentralized energy markets. However, the growing dependence of P2P energy markets on communication infrastructures and distributed coordination mechanisms introduces an expanded cyberattack surface, enabling sophisticated adversaries to manipulate market interactions while remaining concealed from conventional detection mechanisms. This paper first designs an optimal stealthy attack that maximizes economic disruption of the MicroGrids, while preserving the apparent convergence characteristics of the ADMM based market-clearing process. To detect such attacks, a Mahalanobis Boosting detector is developed using market layer features to effectively capture inter feature dependencies and distinguish compromised updates from normal market operation. An adaptive rho based mitigation strategy is then introduced to limit the propagation of compromised information and restore robust market operation once an attack is flagged. The effectiveness of the proposed framework is demonstrated through comprehensive case studies, achieving an attack detection accuracy of 98.49% while the proposed mitigation strategy reduces the operating cost by approximately 18.43% compared to the unmitigated attack case. The proposed approach provides a practical pathway toward trustworthy and cyber-secure distributed P2P energy trading systems.

0.21

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.61
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04

System-Level Factors Influencing AGC Cyber-Attack Success and RAS Vulnerability in Multi-Area Grids

eess.SY ·2026-10-30 ·Abdulmannan Ajabnoor, Zhi Jin Zhang, Maryam Saeedifard, Dominic Groß
published similarity 0.60
Abstract

Automatic generation control (AGC) stabilizes frequency and scheduled power exchanges among interconnected areas, yet its reliance on communication networks introduces cyber-vulnerabilities. This work examines coordinated AGC cyber-attacks in the presence of remedial action schemes (RAS) and identifies operating conditions under which an attacker can drive grid frequency beyond safe limits while evading RAS. A feedback-based attack policy is used to manipulate AGC signals and steer system frequency toward unsafe trajectories. Then, a large nested-loop parametric sweep---spanning attacked-area inertia relative to its interconnected neighboring area, AGC capacity versus maximum tie-line transfer, AGC update rate, load damping, and bi-directional power transfers---generates over 1.45 million scenarios. These are classified using a decision tree to establish guidelines to distinguish successful from unsuccessful attacks based on frequency deviations. The resulting vulnerability guidelines are validated on a three-area system using phasor-domain simulations with IEEE 9-bus area models, detailed turbine--governor dynamics, and under/over-frequency load and generation shedding. Results show that specific combinations of AGC capacity, inertia distribution, and pre-attack tie-line loading increase the likelihood of successful attacks, offering operators actionable criteria for identifying vulnerable operating conditions.

0.41

Checking DER Commands Against Grid Context Catches Credentialed Attacks Static Checks Miss

cs.CR ·2026-11-09 ·Benjamin Blakely
similarity 0.59
Abstract

Authorization of distributed energy resource (DER) commands judges a command by who sent it and whether its value has been seen before. An attacker holding a legitimate credential who writes ordinary values passes both tests. We add a check that judges each DER write against the grid's operating context: the bus voltages around the target, the hour, the day- ahead price, system load, and irradiance, compared with what operators wrote under similar conditions in the feeder's own benign history. We evaluate it live on the IEEE 123-bus and 8500-node feeders, driven by a measured 2024 year of price, load, and irradiance, against nine attack scenarios. A lookup trained on the same history catches none of the writes of the four scenarios that send values already familiar on the targeted device; the context check refuses 91.7% of insider-abuse writes and 64.4% of DER-aggregation writes while denying 1.28% of benign writes. In an offline test that replays recorded moments with curtailment setpoints drawn from the benign range, issued at a positive price, it refuses 47.3% and 50.5% on the two feeders, against 18.5% and 16.0% for the same check without context; live, the few setpoints tested were mostly shallow and were mostly allowed. The context check complements the lookup.

0.40