CS Paper Radar

GRID-MRI: Resilience Assessment of Power Systems under Coordinated Cyber-Physical Attacks

Isaac Ortega Romero, Ioannis Zografopoulos

eess.SY cs.CR ·submitted 2026-11-12 16:55 UTC · v1

Abstract

The increasing penetration of inverter-based resources and growing cyber-physical interdependencies expose electrical power systems to disturbances that challenge conventional resilience assessments. Existing approaches often evaluate resilience dimensions independently, overlooking the non-additive effects of coordinated disruptions and the influence of exogenous stressors. To address this gap, this paper proposes a Grid Multidimensional Resilience Index (GRID-MRI) that integrates endogenous disruption severity, coordination effects, and climatic and economic-regulatory conditions. The framework quantifies physical, cyber, and operational degradation, identifies interaction effects through counterfactual (i.e., what-if), simulations of individual and coordinated attacks, and incorporates exogenous stressors as scenario-dependent scaling factors. Its application to a modified IEEE 39-bus system under three escalating cyber-physical attack scenarios, informed by the December 2025 Polish cyberattack incident, reveals that coordinated attacks induce system collapse despite stable individual and additive responses. The corresponding resilience losses are 3.72 and 4.09 times their additive estimates, while GRID-MRI increases from 0.062 to 1.188 and reaches 6.081 under additional exogenous stress. These findings demonstrate the limitations of additive assessments and establish a quantitative basis for distinguishing the dominant mechanisms of multidimensional resilience degradation.

Comment
IEEE PESGM 2027, 5 pages

Closest papers

Nearest neighbours by meaning across the whole index.

RESILAGENT: A Three-Pillar Architecture for Cyber-Physical Resilience in Electrical Power and Energy Systems

cs.CR cs.AIeess.SY ·2026-11-16 ·Nikolaos Kekatos, Georgios Koutidis, Konstantinos Antonakopoulos, Stylianos Basagiannis, Sokratis Katsikas +4 more
publishedbenchmark similarity 0.66
Abstract · 7 pages, 5 figures, 1 table. Accepted at the 2026 IEEE International Conference on Cyber Security and Resilience (IEEE CSR 2026)

Electrical Power and Energy Systems face hybrid threats that combine cyber intrusions, physical sabotage and climate-driven stress, and routinely outpace today's siloed monitoring stacks. We present RESILAGENT, a concept architecture organised around three operational pillars, Sensing & Data Intelligence, Resilience Analytics & Reporting, and Incident Response & Recovery, mediated by a Cloud-based Orchestrator and exercised through a closed Detect-Simulate-Decide-Sign loop. The framework fuses agentic artificial intelligence and multimodal large language models for cross-modal detection, real-time digital twins for what-if simulation, and a permissioned blockchain anchor for tamper-evident threat intelligence and CER/NIS2-aligned evidence. We instantiate it on two scenarios, a transmission operator under coordinated cyber compromise, sabotage and heatwave, and a distribution operator under a supply-chain compromise during a storm, and report an IEEE-bus micro-benchmark that quantifies each pillar through false-data-injection attack detection, cyber-physical fusion lift, N-1 contingency screening and anchor cost.

0.42

System-Level Factors Influencing AGC Cyber-Attack Success and RAS Vulnerability in Multi-Area Grids

eess.SY ·2026-10-30 ·Abdulmannan Ajabnoor, Zhi Jin Zhang, Maryam Saeedifard, Dominic Groß
published similarity 0.66
Abstract

Automatic generation control (AGC) stabilizes frequency and scheduled power exchanges among interconnected areas, yet its reliance on communication networks introduces cyber-vulnerabilities. This work examines coordinated AGC cyber-attacks in the presence of remedial action schemes (RAS) and identifies operating conditions under which an attacker can drive grid frequency beyond safe limits while evading RAS. A feedback-based attack policy is used to manipulate AGC signals and steer system frequency toward unsafe trajectories. Then, a large nested-loop parametric sweep---spanning attacked-area inertia relative to its interconnected neighboring area, AGC capacity versus maximum tie-line transfer, AGC update rate, load damping, and bi-directional power transfers---generates over 1.45 million scenarios. These are classified using a decision tree to establish guidelines to distinguish successful from unsuccessful attacks based on frequency deviations. The resulting vulnerability guidelines are validated on a three-area system using phasor-domain simulations with IEEE 9-bus area models, detailed turbine--governor dynamics, and under/over-frequency load and generation shedding. Results show that specific combinations of AGC capacity, inertia distribution, and pre-attack tie-line loading increase the likelihood of successful attacks, offering operators actionable criteria for identifying vulnerable operating conditions.

0.41

A Decoupled Approach for Modeling N-k Interdiction with Induced Failures in Electric Power Grids

eess.SY ·2026-10-13 ·Andrew Chio, Kaarthik Sundar, Russell Bent, Nalini Venkatasubramanian
benchmark similarity 0.64
Abstract

The electric power grid is a critical infrastructure system subject to different types of failures which can have devastating impacts on society. One framework to study the resilience of the grid is the N-k interdiction model, which introduces an attacker and defender model to identify grid vulnerabilities. However, traditional N-k interdiction models characterize the power grid with steady-state assumptions. One key aspect missing from this analysis is the behavior of the grid as it evolves from the pre-failure grid state and post-failure grid state. During such a transition period, automated protection systems, transient instabilities, and other phenomena can trigger cascading failures that can occur before grid operators can respond. To bridge this gap, this paper first introduces the generalized induced failure N-k (N-k.k') problem, where an initial set of k failures induces an additional set of k' failures. In this context, we propose a disjoint optimization approach that decouples the computation of cascading failures from the interdiction model. This system response model, furthermore, is treated as a black box module without compromising the underlying performance guarantees of the interdiction model. Extensive experiments on several benchmark power grid case studies showcase the efficacy and scalability of the approach.

0.22

AIDC Microgrid Vulnerability Assessment Under Computing-Power Coordinated Attacks

eess.SY ·2026-08-11 ·Ze Yu, Hongwei Zhen, Chao Shen, Mingyang Sun
similarity 0.63
Abstract

The rapid growth of large language model (LLM) services is expanding AI data centers (AIDCs), increasing electricity demand and associated carbon emissions. Renewable energy integration can mitigate these impacts but also strengthens the coupling between AIDC loads and inverter-interfaced generation, creating cross-domain cyber-physical vulnerabilities. Specifically, adversarial AI requests alter AIDC power demand, whereas inverter control tampering modifies source-side dynamics, and their combined impact on system stability varies with generation forecast and demand response uncertainties. To this end, we propose an uncertainty-aware AIDC microgrid vulnerability assessment framework under computing-power coordinated attacks. First, the framework maps adversarial AI requests to AIDC power variations and represents uncertainties in attack-induced demand responses and photovoltaic (PV) forecasts through confidence-weighted realizations. Then, impedance based stability analysis combines these realizations with bounded inverter parameter tampering to construct attack reachable domains and identify critical attack time windows. Furthermore, a separate criterion identifies fixed coordinated attack vectors that retain destabilizing capability throughout each selected window. Case studies demonstrate that, unlike either attack component applied alone, coordinated attacks within identified critical windows induce sustained inverter frequency oscillations with peak absolute deviations exceeding 20% of nominal frequency, whereas the evaluated out-of-window response remains bounded. The proposed method further identifies critical attack windows and the associated coordinated attack vectors.

0.04

Technical Report on Resilient and Secure Large-Scale Energy Internet Systems

eess.SY cs.CR ·2026-08-13 ·Ioannis Zografopoulos, Karen Largman, Isaac Ortega Romero, S M Zia Ur Rashid, Yexiang Chen +9 more
similarity 0.62
Abstract · Task Force on Resilient and Secure Large-Scale Energy Internet Systems, August 2026

This IEEE PES Task Force report examines the security and resilience of large-scale Energy Internet (EI) systems, in which electricity, information, and market layers are tightly coupled through pervasive digitalization. The report characterizes the EI cyber-physical threat landscape and surveys detection, assurance, and mitigation techniques, presents modeling, control, and decision-making frameworks that capture cyber-physical interdependencies, including storage integration, multi-dimensional resilience, and electricity price forecasting, examines adversarial risks and trustworthy deployment of artificial intelligence, and introduces graph-based, attack-resilient information routing. The report closes with recommendations for research, standardization, and regulatory efforts needed to realize a resilient and secure large-scale EI.

0.04

Robustness of Local Energy Markets to Cyberattacks: Case Study of False Data Injection

cs.CR ·2026-09-29 ·Mehran Moradi, Reza Zamani, Phil Aupke, Andreas Theocharis, Andreas Kassler
similarity 0.62
Abstract

Market clearing in community-based local energy markets relies on power demand and PV forecasts, making it vulnerable to coordinated false data injection (FDI) attacks. This paper proposes a bilevel optimization framework to identify worst-case bus-level FDI against interconnected multi-community electricity markets within a distribution network. The upper level attacker maximizes physical impact, measured by cumulative voltage deviation, while accounting for detectability. The lower level re-clears the interconnected multi-community markets subject to operational and network constraints. The bilevel model is reformulated as a single-level mixed-integer program through Karush-Kuhn-Tucker conditions and solved using the epsilon constraint method to characterize the trade-off between physical impact and detectability. Case studies on the IEEE 33-bus system with three communities show that even bounded, system-level zero-sum attacks can reshape local trading, reduce voltage security margins, and produce asymmetric community-level market outcomes. The results further show that vulnerability depends strongly on the spatiotemporal placement of falsified data rather than on uniform spreading across buses and time periods.

0.26

LLM-Guided Cyber-Physical Attack Path Identification in Smart Grids

cs.CR cs.AI ·2026-11-18 ·Amr Elshazly, Jesse Roberts, Rachad Atat, Muhammad Ismail
published similarity 0.61
Abstract · 7 pages, 4 figures, 1 table. Accepted at IEEE IECON 2026

Identifying high-impact attack paths in cyber-physical power systems is critical for improving grid resilience. Existing methods typically rely on either structural topology analysis or simulation-based cascading-failure models. Topology-based approaches capture connectivity but lack adversarial reasoning, while simulation-driven methods are primarily suited for offline analysis and are less effective for rapid evaluation of evolving attack scenarios. As a result, identifying realistic attack paths that jointly capture topology, threat semantics, and physical impact remains challenging. This paper presents a physics-grounded framework for identifying cyber-physical attack paths using large language models (LLMs), with cascading-failure-derived impact rankings used as physics-grounded references. The framework integrates system topology, LLM-guided STRIDE and MITRE ATT&CK threat modeling, and three baseline strategies for comparison: topology-driven, threat-driven, and fusion-based. Evaluation is performed using (i) critical-node overlap between LLM-inferred top-K rankings and cascading-failure-based ground truth; (ii) node-level similarity between LLM-inferred and reference paths; and (iii) path-level alignment capturing agreement in complete attack sequences. Results show that structured LLM-based threat modeling substantially improves alignment with physics-grounded references. In the cyber layer, critical-node overlap@3 increases from approximately 33% to as high as 100%, while node-level similarity reaches up to 65% and path-level alignment reaches up to 48%. In addition, the proposed framework reduces runtime by approximately 75--85% compared to the fusion-based baseline in the IEEE 14-bus system. These results suggest that LLM-guided attack path identification is a promising approach for efficient and impact-aware cyber-physical security analysis.

0.35

Attack-Resiliency Analytics for Wide-Area Control Systems in Smart Grids

eess.SY ·2026-09-29 ·Mohammad Zakaria Haider, Prabin Mali, Nur Imtiazul Haque, Muhammad Nadeem, Sumit Paudyal +1 more
similarity 0.59
Abstract

Wide-area monitoring, protection, and control (WAMPAC) systems damp inter-area oscillations in large interconnected grids, but their reliance on synchronized PMU measurements carried over wide-area networks exposes them to false data injection (FDI) attacks. This paper presents an attack-resiliency analytics framework that formally models the coupled dynamics of the wide-area damping loop, automatic generation control, and the governor and excitation systems, and formulates the optimal stealthy FDI attack as a mixed-integer linear program (MILP). The anomaly detection model (ADM) enters as a replaceable constraint set: either a static bad-data detection (BDD) rule or a boundary learned from benign operation calibrated to a common false-positive rate. On the IEEE 39 and 118 bus systems, with reference dynamics validated on an OPAL-RT hardware-in-the-loop testbed, the optimal attack with wide-area access attains 3.3 and 8.1 times the benign objective and reaches a 0.5Hz frequency excursion more than twice as fast as an attack confined to automatic generation control. Learned boundaries reduce the attack objective by 15.5 55.0% and prevent over-frequency relay trips in all configurations, with feasible stealthy attacks remaining in every case, and residual risk tracks the width of the learned boundary rather than the detector family.

0.31