CS Paper Radar

A Multi-Stage Linear Programming Framework for Three-Phase State Estimation in Low-Voltage Distribution Grids

Mohsen Banaei, Eghbal Hosseini, Ahlam Jameel, Konstantin Filonenko, Shahrzad Pour, Razgar Ebrahimy

eess.SY ·submitted 2026-09-24 09:49 UTC · v1
published

Abstract

Low-voltage (LV) distribution feeders are increasingly difficult to monitor because real-time load data are unavailable, historical measurements are sparsely sampled, and high-rate voltage sensors cover only a few nodes. This paper proposes a multi-stage linear programming (MSLP) estimator for three-phase unbalanced LV grids that reconstructs per-phase nodal voltages under such limited observability. The estimator linearises the three-phase power flow through voltage-to-power sensitivity matrices and adjusts the nodal active and reactive power injections so that the resulting voltages match the available measurements. To limit the error introduced by linearisation, the sensitivities are rebuilt and the power corrections refined over successive iterations, and power-balance constraints at intermediate metered nodes are added to tighten the feasible region. The method is validated on a real 50-node Danish LV feeder, where it attains a mean absolute error of 0.641V, a standard deviation of 0.816V, a root-mean-square error of 0.842~V, and a maximum error of 3.437V. Compared with a single-stage linear estimator, MSLP lowers the error metrics by roughly 16 percent on average, and additional studies quantify the influence of the input-preparation strategy and of the number of estimation meters.

Comment
Presented at the International Energy Future Conference, 2025, Rome

Closest papers

Nearest neighbours by meaning across the whole index.

Topology-adaptive Estimation of Maximum Voltage Unbalance for Distribution Networks with Finite-sample Guarantee

eess.SY ·2026-10-14 ·Jinbao Wang, Jun Liu, Shiliang Zhang, Xuehui Ma, He Zhang
similarity 0.61
Abstract

High penetration of single-phase distributed power production and frequent topology changes can significantly increase voltage unbalance in distribution networks. Reliable probabilistic power flow (PPF) assessment for the network, therefore, must account for topology-dependent power-flow equations, numerical error in the voltage unbalance factor (VUF), and finite-sample uncertainty in power measurements. In this paper, we propose Topology-Adaptive Certified Quantile Estimation (TACQE) to estimate the maximum VUF across monitored electric buses. Following a local network change, TACQE updates the cross-couplings among power-flow sequences, and certifies candidate PPF solutions against the updated nonlinear equations. The resulted power-flow state enclosures provide rigorous bounds on the maximum VUF. Furthermore, we derive independent reference-solver evaluations to calibrate discrepancies from the reference PPF solution. This leads to a uniform sampling bound that yields simultaneous upper-tail probabilities and quantiles, which provides a finite-sample guarantee for the estimated maximum-VUF distribution over an entire range of VUF thresholds. From our numerical simulations across 101 fixed-topology quantiles, it demonstrates that the designed TACQE can provide a fast candidate post-change power flow solution where it reuses most of the previous network model and modifies only the affected bus blocks.

0.17

A Deficiency-Based Approach for Unbalanced Three-Phase Distribution System Expansion Planning

eess.SY ·2026-10-12 ·Eli Brock, Miguel Heleno, Javad Lavaei, Somayeh Sojoudi
benchmark similarity 0.61
Abstract · 12 pages, 1 figure, 3 tables. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice…

Distribution planners typically characterize grid needs through power flow studies and fit upgrades to those needs by hand. More principled one-shot optimization methods either do not scale or misrepresent unbalanced three-phase networks. This paper proposes an iterative planning process that alternates between two problem classes with mature off-the-shelf solvers. An optimal power flow (OPF) problem quantifies the deficiency of a candidate portfolio by optimizing the dispatch of controllable devices and measuring thermal and voltage violations on a common scale, with an optimal value of zero exactly at adequate portfolios. The OPF multipliers give a first-order approximation of the relief each investment candidate would provide. We bound the error of this approximation and show that structural properties of the deficiency guard it against overestimation. Building on this property, a heuristic cutting-plane search uses a mixed-integer linear program to propose each next portfolio from these approximations. On six unbalanced three-phase feeders from the SMART-DS dataset, the search outperforms a linearized optimization-based benchmark, and the results agree across five variants of the deficiency.

0.21

Efficient Quantile-Resolved Hosting Capacity Assessment on Nodal Level for Low-Voltage Grids

eess.SY ·2026-09-08 ·Maximilian Köhler, Edwin Mora, Mathias Duckheim, Stefan Niessen
similarity 0.57
Abstract · Submitted to IEEE PES ISGT Europe 2026. 5 pages, 3 figures. Keywords: Hosting Capacity, Uncertainty, Distribution Grid, Distributed Energy R…

Hosting capacity - the maximum additional capacity a network can accommodate without violating operational limits - is a key metric in distribution system planning and operation. Decisions on grid reinforcements and the deployment of flexibility management require not only the worst-case HC but also an understanding of the distribution of HC under different likelihoods in load and generation patterns. Quantile-resolved HC distributions provide this view by expressing HC as a function of an acceptable operational limit exceedance likelihood. Monte Carlo sampling is the established approach for computing such distributions but demands large computational resources. Approximations sacrifice either accuracy, the ability to capture uncertainty correlations, or scalability when assessing real-world networks. This paper introduces a computationally efficient method for calculating distributions for quantile-resolved HC. It uses a representation of load samples as multivariate normal distribution, propagated through a linearized power flow model. This allows for leveraging a re-parametrized AC-OPF problem for each hosting capacity quantile. Benchmarking against Monte Carlo-based methods on realistic LV networks demonstrates that the proposed method achieves comparable accuracy with a mean deviation of approx. 3%, while reducing computational time by orders of magnitude. For the exemplary networks the computational time decreases from 11 min to 2 s, and 38 h to 50 s, respectively. The method's scalability is also suitable for recalculation in 15-minute cycles encountered in DSO practice for e.g., real-time grid management.

0.21

QSVT-Based Three-Phase Unbalanced Power Flow

cs.ET ·2026-09-02 ·Kamini Shahare, Peng Zhang
benchmarkunusual similarity 0.57
Abstract

This letter introduces QSVT-3PF, a quantum singular value transformation (QSVT) based solver for three-phase unbalanced power flow with embedded single-phase grid-forming inverter (GFM) operation. The contributions are threefold: 1) reformulating the Newton correction as a QSVT-compatible inverse problem using a normalized block-encoded phase-domain Jacobian; 2) introducing a regularized singular-value filter to improve robustness under ill-conditioned and stressed operating conditions; and 3) validating the proposed solver on an IEEE 5-bus system and the IEEE 123-node test feeder with single-phase GFM integration. Test results show that QSVT-3PF matches the classical Newton benchmark in residual convergence, voltage profile, and final operating point, demonstrating the feasibility of QSVT-3 for large, unbalanced distribution systems.

0.34

Reinsertion-Aware Parameter Estimation of the WECC Composite Load Model via Closed-Loop Equivalent-Network Co-Estimation

eess.SY ·2026-10-25 ·Jong Ha Woo, Victor Daldegan Paduani, Zishuo Yang, Yu Ma, Qi Xiao +1 more
benchmark similarity 0.55
Abstract · 10 pages, 10 figures, 7 tables. Submitted to IEEE Transactions on Power Systems

Measurement-based parameter estimation of the WECC composite load model (CMLD) commonly relies on voltage replay, where measured voltage is imposed on an isolated CMLD and its parameters are optimized to reproduce measured active and reactive power. However, this open-loop formulation neglects the two-way dynamic interaction between the load and grid, potentially causing large errors when the estimated model is reinserted into dynamic grid simulations. To address this limitation, we propose a closed-loop parameter estimation framework that alternately estimates the CMLD parameters and a five-parameter equivalent network representing the external grid. This framework restores load-grid interaction during estimation and enables voltage, active power, and reactive power to jointly constrain the parameter estimation. Compared with four baseline methods, the proposed approach achieves the highest reinsertion accuracy in both the CMLD benchmark and transmission and distribution (T&D) co-simulation environments. In the T&D case, it reduces active-power, reactive-power, and voltage errors by 73%, 64%, and 62%, respectively. The identified model also maintains improved reinsertion accuracy under disturbances not used for estimation, demonstrating transferability beyond the identification event.

0.47

Embedding Single-Phase Grid-Forming Inverters in Three-Phase Unbalanced Power Flow

cs.ET ·2026-09-02 ·Kamini Shahare, Fei Feng, Peng Zhang
similarity 0.55
Abstract

This letter introduces Grid-Forming Three-Phase Power Flow (GFM-3PF), an augmented Newton power flow framework for modeling single-phase grid-forming inverters (GFMs) in three-phase unbalanced networks. The contributions of this work are threefold: 1) developing a two-stage solution strategy based on positive-sequence initialization followed by three-phase phase-domain lifting for robust large-scale computation; 2) incorporating phase-domain unbalanced network modeling with controlled mutual coupling together with phase-dependent, frequency-sensitive load representation; and 3) embedding a single-phase GFM bus model directly into the three-phase unbalanced Newton power flow equations through a common droop-governed frequency state. GFM-3PF is validated on 3-bus, 33-bus, and 118-bus test systems, demonstrating its accuracy, robustness, and scalability.

0.54

Data-driven Linearization of Operational Dynamics of Soft Open Points in Power Distribution Networks

eess.SY ·2026-11-19 ·Shoaib Hussain, Mostafa Farrokhabadi, Hamidreza Zareipour
hot direction similarity 0.55
Abstract · 7 pages, 7 figures, 5 tables

This paper proposes a novel data-driven linearization of operational power losses in a Soft Open Point (SOP). The proposed learning-based representation, combined with the standard segmentation of the quadratic device capacity inequalities, linearizes the operational dynamics of SOPs in unbalanced power distribution network applications without a significant drop in power loss estimation accuracy. The technique was tested in three applications using a three-phase extension of the IEEE 33-bus network. The case studies include a sizing application for a multi-terminal phase-changing soft open point (PCSOP), an operational optimization application for an active distribution network featuring a PCSOP, and a system simulation engine built for a Deep Reinforcement Learning (DRL) application that trains an agent to optimally dispatch a PCSOP in an unbalanced distribution network. The results of the three case studies were validated against the standard nonlinear AC load-flow representations and point to the efficacy of the proposed solution.

0.41

Bayesian Distribution System State Estimation with Flow Matching

cs.LG cs.AIeess.SP ·2026-10-29 ·Nan Lin, Peter Palensky, Pedro Vergara Barrios
similarity 0.53
Abstract · 10 pages

Medium-voltage feeders have few real-time measurements, so distribution system state estimation (DSSE) rests on pseudo-measurements of the secondary substations, a prior in Bayesian terms. Weighted least squares keeps the power flow exact but reduces this prior to a mean and variance, while supervised deep learning estimators also learn the power flow and are tied to one measurement set. We propose PoSE (posterior sampling for state estimation), which keeps the Bayesian structure of DSSE and learns only what the distribution system operator does not know, namely the distribution of substation injections, modelled by a neural network trained with flow matching on historical data. The power flow equations, grid topology and measurements enter only at sampling, through a noise-aware Kalman-type correction. The neural network therefore never approximates the power flow, but every posterior sample is a physically consistent operating point, and one trained prior serves any measurement set, noise level and topology. On the IEEE 33-bus feeder, PoSE lowers the probabilistic injection error (CRPS) by 6.7-7.5% against a full-covariance Gaussian prior in all 12 tested settings. It provides reliable uncertainty: the 90% intervals contain the true injection almost exactly as often as exact posterior samples would, whereas those of supervised estimators contain it in only 37-78% of cases. On the 240-bus unbalanced three-phase Iowa feeder, it gives the lowest injection, voltage and branch-current errors of all estimators. A fast variant matches this accuracy at 0.2-0.6s per snapshot and, without retraining, beats Gaussian priors and retrained supervised estimators on seven reconfigured topologies.

0.17