CS Paper Radar

QSVT-Based Three-Phase Unbalanced Power Flow

Kamini Shahare, Peng Zhang

cs.ET ·submitted 2026-09-02 21:08 UTC · v1
benchmarkunusual

Abstract

This letter introduces QSVT-3PF, a quantum singular value transformation (QSVT) based solver for three-phase unbalanced power flow with embedded single-phase grid-forming inverter (GFM) operation. The contributions are threefold: 1) reformulating the Newton correction as a QSVT-compatible inverse problem using a normalized block-encoded phase-domain Jacobian; 2) introducing a regularized singular-value filter to improve robustness under ill-conditioned and stressed operating conditions; and 3) validating the proposed solver on an IEEE 5-bus system and the IEEE 123-node test feeder with single-phase GFM integration. Test results show that QSVT-3PF matches the classical Newton benchmark in residual convergence, voltage profile, and final operating point, demonstrating the feasibility of QSVT-3 for large, unbalanced distribution systems.

Closest papers

Nearest neighbours by meaning across the whole index.

Embedding Single-Phase Grid-Forming Inverters in Three-Phase Unbalanced Power Flow

cs.ET ·2026-09-02 ·Kamini Shahare, Fei Feng, Peng Zhang
similarity 0.69
Abstract

This letter introduces Grid-Forming Three-Phase Power Flow (GFM-3PF), an augmented Newton power flow framework for modeling single-phase grid-forming inverters (GFMs) in three-phase unbalanced networks. The contributions of this work are threefold: 1) developing a two-stage solution strategy based on positive-sequence initialization followed by three-phase phase-domain lifting for robust large-scale computation; 2) incorporating phase-domain unbalanced network modeling with controlled mutual coupling together with phase-dependent, frequency-sensitive load representation; and 3) embedding a single-phase GFM bus model directly into the three-phase unbalanced Newton power flow equations through a common droop-governed frequency state. GFM-3PF is validated on 3-bus, 33-bus, and 118-bus test systems, demonstrating its accuracy, robustness, and scalability.

0.54

A Multi-Stage Linear Programming Framework for Three-Phase State Estimation in Low-Voltage Distribution Grids

eess.SY ·2026-09-24 ·Mohsen Banaei, Eghbal Hosseini, Ahlam Jameel, Konstantin Filonenko, Shahrzad Pour +1 more
published similarity 0.57
Abstract · Presented at the International Energy Future Conference, 2025, Rome

Low-voltage (LV) distribution feeders are increasingly difficult to monitor because real-time load data are unavailable, historical measurements are sparsely sampled, and high-rate voltage sensors cover only a few nodes. This paper proposes a multi-stage linear programming (MSLP) estimator for three-phase unbalanced LV grids that reconstructs per-phase nodal voltages under such limited observability. The estimator linearises the three-phase power flow through voltage-to-power sensitivity matrices and adjusts the nodal active and reactive power injections so that the resulting voltages match the available measurements. To limit the error introduced by linearisation, the sensitivities are rebuilt and the power corrections refined over successive iterations, and power-balance constraints at intermediate metered nodes are added to tighten the feasible region. The method is validated on a real 50-node Danish LV feeder, where it attains a mean absolute error of 0.641V, a standard deviation of 0.816V, a root-mean-square error of 0.842~V, and a maximum error of 3.437V. Compared with a single-stage linear estimator, MSLP lowers the error metrics by roughly 16 percent on average, and additional studies quantify the influence of the input-preparation strategy and of the number of estimation meters.

0.32

EMT Assessment of SCR and X/R Effects on Current-Priority-Dependent LVRT Response of a Grid-Following BESS

eess.SY ·2026-10-30 ·Dileep Cheerla, Amirthagunaraj Yogarathnam, Divya Jain, Satish Natti
similarity 0.56
Abstract · 6 pages, 4 figures. Submitted to the 2027 IEEE Texas Power and Energy Conference (TPEC 2027)

Low-voltage ride-through (LVRT) forces a grid-following inverter to allocate finite converter current between active- and reactive-current objectives. This paper uses a PSCAD electromagnetic-transient (EMT) representation of an aggregated battery energy storage system (BESS) to quantify how short-circuit ratio (SCR) and grid impedance X/R ratio alter that tradeoff. Active-current priority and reactive-current priority are compared for five paired grid conditions under the same 150-ms balanced three-phase fault, with pre-fault active power approximately 0.84 pu, POI reactive-power exchange near 0 pu, and a 1.0-pu dq-current limit. Fundamental positive-sequence voltage and power are reconstructed from 100-$μ$s three-phase EMT outputs. Across the fixed-fault SCR sweep, the Q-priority late-fault voltage advantage increases from 0.046 pu in the strongest tested grid to 0.129 pu in the weakest; the weakest P-priority case also shows active-power reversal and a pronounced controller-frequency excursion. At fixed SCR, changing X/R produces a smaller increase from 0.092 to 0.112 pu, mainly through reduced P-priority voltage support. Because the common physical fault also deepens the passive retained-voltage condition as SCR decreases, the SCR result is interpreted as a fixed-fault grid-strength sensitivity rather than a constant-sag comparison. Grid strength is the larger sensitivity in the tested matrix, while X/R remains an additional modifier under the studied fault conditions.

0.37

A Deficiency-Based Approach for Unbalanced Three-Phase Distribution System Expansion Planning

eess.SY ·2026-10-12 ·Eli Brock, Miguel Heleno, Javad Lavaei, Somayeh Sojoudi
benchmark similarity 0.53
Abstract · 12 pages, 1 figure, 3 tables. This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice…

Distribution planners typically characterize grid needs through power flow studies and fit upgrades to those needs by hand. More principled one-shot optimization methods either do not scale or misrepresent unbalanced three-phase networks. This paper proposes an iterative planning process that alternates between two problem classes with mature off-the-shelf solvers. An optimal power flow (OPF) problem quantifies the deficiency of a candidate portfolio by optimizing the dispatch of controllable devices and measuring thermal and voltage violations on a common scale, with an optimal value of zero exactly at adequate portfolios. The OPF multipliers give a first-order approximation of the relief each investment candidate would provide. We bound the error of this approximation and show that structural properties of the deficiency guard it against overestimation. Building on this property, a heuristic cutting-plane search uses a mixed-integer linear program to propose each next portfolio from these approximations. On six unbalanced three-phase feeders from the SMART-DS dataset, the search outperforms a linearized optimization-based benchmark, and the results agree across five variants of the deficiency.

0.21

Towards Efficient Edge AI for Power Flow in Renewable-Rich Grids with Volt/VAR Control

eess.SY ·2026-11-11 ·Shahariya R. R. Puthanpurayil, Vlad A. Sanduleac, Remus Teodorescu
code/data similarity 0.51
Abstract

AI models of the power grid must capture how wind and solar plants support the voltage, adjusting their reactive power to the local voltage along a grid-code Q(V) characteristic. This research examines whether grid foundation models, fast neural network models for power-flow analysis, can represent this behaviour. We introduce the Q(V) bus, a new bus type for the open-source GridFM GraphKit, whose physics decoder evaluates the reactive injection from the plant characteristic at the predicted voltage in every correction step. Training data comprise 7882 hourly operating points of a modified IEEE 118-bus system, matched to Energinet DK1/DK2 measurements and solved with pandapower. Compared with a physics-informed baseline that represents the parks as negative load, the Q(V) bus lowers the voltage-magnitude RMSE 2.3-fold, reduces the power-balance mismatch at the parks from 25 to 0.66 MVA, and raises the F1 score for voltage-band violations from 0.40 to 0.76. An ablation over five configurations shows that the Q(V) bus type provides the accuracy and the physics loss provides the power balance. For edge monitoring, we distil the trained $2.0\times10^{7}$-parameter model into students of $6\times10^{5}$ and $1.3\times10^{6}$ parameters; a flat-start initialisation prevents their collapse into an incorrect low-voltage state in which the characteristic saturates. With output distillation, the 12-step student reaches 1.4 times the teacher's error and, for edge inference on an NVIDIA Jetson Orin Nano (15 W), solves an hourly scenario in 12.2 ms, within the 20 ms synchrophasor interval.

0.34

Volt-VAr-Watt Optimization in Four-Wire Low-Voltage Networks: Exact Nonlinear Models and Smooth Approximations - Extended Version

eess.SY ·2026-09-14 ·Sleiman Mhanna, Frederik Geth, Lucas Quiertant, Pierluigi Mancarella
top venue similarity 0.50
Abstract · Extended version of the article published in IEEE Transactions on Power Systems, vol. 41, no. 5, pp. 3663-3677, 2026. DOI: 10.1109/TPWRS.202…

The proliferation of distributed energy resources is increasing the prevalence of both overvoltages and undervoltages in low-voltage (LV) distribution networks. Smart inverter functionalities, such as Volt-VAr and Volt-Watt control, can regulate voltage at the consumer level but are challenging to capture in optimization models due to their nondifferentiability. This paper proposes three nonlinear models for four-wire unbalanced optimal power flow that incorporate these nonsmooth functions without binary or integer variables. The first model encodes these nonsmooth functions directly as user-defined functions using control flow, a feat enabled by many state-of-the-art algebraic modeling languages. The second and third introduce bespoke smooth approximations with tunable approximation errors to address potential numerical issues arising from nondifferentiability, improving reliability while maintaining accuracy. All three methods are evaluated on real four-wire unbalanced LV networks with varying rooftop solar adoption levels, including a 539-bus system with 302 smart inverters. This paper is not only the first to demonstrate accurate, reliable, and tractable Volt-Var-Watt optimization (VVWO) on real four-wire unbalanced LV network models, but it also establishes that optimization-based, non-incremental methods offer superior reliability compared to commonly used incremental (quasi-steady-state) approaches.

0.60

Fixed-Time Voltage Regulation in Distribution Networks with Impedance Awareness

eess.SY ·2026-10-01 ·Nilanjan Roy Chowdhury, Venkatesh Sarangan
similarity 0.50
Abstract · 8 pages, 6 figures

This letter introduces an optimization-based fixed time control algorithm for solving the voltage regulation problem of a radial and balanced power distribution network. The proposed algorithm requires no prior knowledge of the exact network impedance (resistance and reactance), yet guarantees voltage convergence to the predefined safe limit within a fixed time-window. We embrace results from Fixed-time stability (FxTs) and Control Lyapunov function (CLF) to analyze the stability and robustness of the underlying algorithm and then synthesize it leveraging the Quadratic Programming (QP) approach. We first analytically provide sufficient conditions on the control gains and the design parameters, that can ensure voltage regulation in fixed-time. Thereafter we transform the existing voltage regulation problem into an equivalent QP-based optimization framework and translate the aforesaid conditions to find feasible solutions for voltage stability. We empirically verify the efficacy of our proposed algorithm on the IEEE-33 bus distribution network and compare its performance against other existing robust control methods.

0.29

Blackbox Small-Signal Modeling of Grid-Connected Inverters in Asymmetrical Power Grids

eess.SY ·2026-09-01 ·Airan Frances, Dionisio Ramirez, Javier Uceda
top venuehighly cited similarity 0.49
Abstract · 11 pages, 14 figures, IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 38, NO. 10, OCTOBER 2023

Power electronic converters are envisaged to be key enablers of modern electric power distribution systems. Grid-connected three-phase inverters are widely used in Smart Grids and microgrids, but also in standard grids. They provide controllability and dynamic decoupling capabilities, which are fundamental in the integration of renewable sources and storage systems and in specialized applications such as FACTS. Nevertheless, power electronics-based systems can exhibit dynamic interactions, which may lead to power quality issues. Although the electrical model of each element of these systems is important for their system-level analysis, they are rarely available. Blackbox modeling strategies are useful for obtaining behavioral models of commercial electronic converters. Most blackbox modeling strategies are focused on dc-dc electronic converters; however, some works have extended these concepts to three-phase converters by means of the dq framework, under the assumption of symmetrical and balanced conditions. This work proposes a new structure in the sequence domain to represent the dynamic behavior of grid-connected commercial converters in asymmetrical conditions. Experimental tests have been performed on a three-phase inverter to identify its blackbox model and its performance has been validated during an asymmetric voltage sag.

0.82