CS Paper Radar

Volt-VAr-Watt Optimization in Four-Wire Low-Voltage Networks: Exact Nonlinear Models and Smooth Approximations - Extended Version

Sleiman Mhanna, Frederik Geth, Lucas Quiertant, Pierluigi Mancarella

eess.SY ·submitted 2026-09-14 10:56 UTC · v1
top venue

Abstract

The proliferation of distributed energy resources is increasing the prevalence of both overvoltages and undervoltages in low-voltage (LV) distribution networks. Smart inverter functionalities, such as Volt-VAr and Volt-Watt control, can regulate voltage at the consumer level but are challenging to capture in optimization models due to their nondifferentiability. This paper proposes three nonlinear models for four-wire unbalanced optimal power flow that incorporate these nonsmooth functions without binary or integer variables. The first model encodes these nonsmooth functions directly as user-defined functions using control flow, a feat enabled by many state-of-the-art algebraic modeling languages. The second and third introduce bespoke smooth approximations with tunable approximation errors to address potential numerical issues arising from nondifferentiability, improving reliability while maintaining accuracy. All three methods are evaluated on real four-wire unbalanced LV networks with varying rooftop solar adoption levels, including a 539-bus system with 302 smart inverters. This paper is not only the first to demonstrate accurate, reliable, and tractable Volt-Var-Watt optimization (VVWO) on real four-wire unbalanced LV network models, but it also establishes that optimization-based, non-incremental methods offer superior reliability compared to commonly used incremental (quasi-steady-state) approaches.

Comment
Extended version of the article published in IEEE Transactions on Power Systems, vol. 41, no. 5, pp. 3663-3677, 2026. DOI: 10.1109/TPWRS.2026.3677246
Journal ref
IEEE Transactions on Power Systems, vol. 41, no. 5, pp. 3663-3677, 2026
DOI
10.1109/TPWRS.2026.3677246

Closest papers

Nearest neighbours by meaning across the whole index.

Day-ahead Coordination of Virtual Power Plants within Active Distribution Networks using Deterministic Bi-Level Optimization

cs.CE math.OCeess.SY ·2026-09-15 ·Laura M. Barajas-Arguello, Rafael A. Núñez-Rodríguez, Daniel Gebbran, Clodomiro Unsihuay-Vila
publishedtheory similarity 0.62
Abstract

This paper proposes a deterministic bilevel optimization framework for the coordinated operation of Virtual Power Plants (VPPs) embedded in an active distribution network. The Distribution System Operator (DSO) acts as the upper-level leader, minimizing a weighted combination of expenditure, active losses and voltage deviation subject to nonlinear AC power flow constraints, while each VPP operates as a lower-level follower that maximizes its profit under the uniform price signal issued by the DSO. Unlike most existing formulations, which linearize the lower-level subproblem to obtain a Mixed-Integer Linear Program (MILP), the proposed model retains the full AC Optimal Power Flow (AC-OPF) equations, producing a bilevel Mixed-Integer Nonlinear Program (MINLP). The lower-level problem is replaced by its Karush-Kuhn-Tucker (KKT) optimality conditions and the Strong Duality Theorem, yielding a single-level Mathematical Program with Equilibrium Constraints (MPEC). Complementarity conditions are then linearized via the Fortuny-Amat big-M transformation. The framework is validated on the IEEE 33-bus feeder over a 24-hour horizon, with four distributed resources aggregated into a single VPP. Compared with individual dispatch against a regulated time-of-use tariff, aggregation reduces active losses by 10.5 %, the accumulated voltage deviation by 18.3 %, and the bus-hours below 0.95 p.u. from 132 to 29. These gains cost 0.31 % in social cost and 0.26 % in DSO expenditure, while the rent of the aggregator is preserved.

0.25

Coordinated Conservation Voltage Reduction and Network Topology Reconfiguration in Active Distribution Networks

eess.SY ·2026-10-12 ·Rida Fatima, Hassan Zahid Butt, Xingpeng Li
similarity 0.61
Abstract

Distribution networks rely on conservation voltage reduction (CVR) and network topology reconfiguration (NTR) to manage demand, distributed energy resources (DERs), and tighter operating margins. Yet these strategies are typically deployed independently, despite coupled effects on feeder voltages, losses, and loading. This paper addresses that gap by developing a day-ahead mixed-integer second order cone programming (MISOCP) framework that jointly optimizes feeder head voltage control and network reconfiguration. The formulation incorporates AC branch flow constraints, ZIP load models, DERs, battery energy storage systems, and multi substation radiality. Using modified IEEE 33 bus and 123 bus systems, four configurations isolate the individual and coordinated effects of CVR and NTR. On the 33-bus system under mixed ZIP loading, NTR reduces active energy loss by 2.50%, while coordinated operation reduces it by 2.91% relative to SDN and produces a 2.46% CVR induced active load reduction relative to SDNTR. Under constant impedance loading, coordinated operation reduces active energy loss by 17.65% relative to SDN, while CVR reduces active load by 14.61% relative to SDNTR. DER portfolio scaling shows a nonmonotonic coordinated load reduction response, strongest at 20% penetration and decreasing at higher levels. On the 123 bus system, NTR reduces losses by 19.3%, while CVR reduces voltage dependent load energy by 2.3 to 2.4%. Under loading stress, SDN becomes infeasible at 120% loading, whereas CEDNTR remains feasible. Overall, the results demonstrate complementary, operating condition dependent benefits shaped by load composition, DER portfolio scaling, feeder topology, voltage margins, and source constraints, highlighting the value of joint optimization.

0.29

Optimal Coordination of Heat Pump Demand Flexibility and Battery Energy Storage Considering the Operation of Distribution Networks

eess.SY ·2026-10-06 ·Gustavo L. Aschidamini, Guilherme S. Castiglio, Mariana Resener
similarity 0.61
Abstract

Electrifying space heating with heat pumps (HP) and backup electric-resistance heaters (ERH) is incentivized to support decarbonization but increases voltage and thermal issues in distribution networks. Direct load control (DLC) of smart thermostats (ST) provide grid support, yet, to the best of our knowledge, existing methods do not co-optimize this flexibility with grid-scale battery energy storage systems (BESS) and voltage-regulation devices, and do not use ERH for preheating, limiting peak demand reduction and undervoltage mitigation. We propose a mixed-integer linear programming (MILP)-based model predictive control (MPC) framework that coordinates ST setpoints for preheating and setback, grid-scale BESS, on-load tap changers, switched capacitor banks, and step voltage regulators. The framework is evaluated on 23-node and 733-node distribution networks, including a real-data-based feeder, across multiple realized days. On the 23-node feeder with 50% HP penetration and 50% DLC participation, the proposed framework reduces the feeder peak by 23.1%, and by 27.1% with the co-optimized BESS. Rolling-horizon setpoint optimization contributes 6.5 percentage points beyond a day-ahead ST schedule (16.6%), and dispatching the ERH for preheating adds 2.7 percentage points beyond backup-only operation (20.4%). On the 733-node feeder, where thermal congestion is the binding constraint, the framework reduces overloaded branches by 94% and overloaded transformers by 47%. These results demonstrate the potential of coordinated demand flexibility and voltage regulation to accommodate heating electrification.

0.12

Co-Optimization of Network Topology and Variable Impedance Devices under Dynamic Line Ratings Using Iterative McCormick Relaxation

eess.SY ·2026-10-27 ·Junseon Park, Hyeongon Park, Rahul K. gupta
benchmark similarity 0.61
Abstract

Grid Enhancing Technologies (GETs), such as Network Topology Optimization (NTO), Dynamic Line Rating (DLR), and Variable Impedance Devices (VIDs) are increasingly deployed in power transmission grids to address congestion and improve grid utilization. However, their growing adoption necessitates coordinated operation to fully exploit their benefits. This paper presents a unified co-optimization framework that integrates NTO, DLR, and VID to alleviate congestion and minimize operational costs. NTO is modeled using a node-breaker formulation to provide enhanced switching granularity, while DLR incorporates weather-dependent parameters, including wind speed and ambient temperature, to dynamically adjust transmission limits. The resulting formulation is a mixed-integer nonlinear program due to power flow constraints with bilinear VID terms, and discrete topology decisions. To improve tractability, we propose using a McCormick relaxation approach to linearize bilinear terms. Furthermore, we propose an iterative refinement of the McCormick relaxation scheme to enhance solution accuracy. The proposed framework is validated through detailed analyses on the IEEE 118-bus system, along with additional case studies on other benchmark systems to assess scalability. Results demonstrate that the proposed approach improves solution accuracy compared to standard McCormick relaxation, achieves solution quality close to the nonlinear formulation, and maintains computational efficiency.

0.29

Generalized and Unified Power Flow Framework for Converter-Dominated AC/DC Power Grids

eess.SY ·2026-10-18 ·Hamin Chang, Fei Teng, Gyu-Sub Lee, Jae-Won Chang
code/data similarity 0.59
Abstract · Submitted to IEEE Transactions on Power Systems. 10 pages + 10-page appendix (Appendices A-C included at the end). Code: https://github.com/…

Modern power grids increasingly rely on power electronic interfaces, requiring steady-state power flow analysis to accommodate diverse operating modes and network structures. Conventional approaches often rely on system-specific formulations and sequential approaches to handle such complexity. However, these approaches may limit applicability to diverse grid configurations and lead to convergence and computational issues. To address these limitations, this paper proposes a generalized and unified Newton-Raphson (NR) power flow framework for AC/DC hybrid grids. For generalized operational modeling, conventional and droop operating modes of generators and interlinking converters are represented through a common set of coefficients. For generalized structural modeling, models of AC transformers and DC/DC converters accommodate different transformer winding configurations and converter operating modes. For a unified solution, augmented variables are introduced to incorporate droop deadbands, output limits, and converter station losses into a single NR formulation, eliminating the need for sequential outer loops. To validate the effectiveness of the proposed framework, its results are compared with those obtained from existing power flow methods and electromagnetic transient simulations across transmission networks, distribution networks, and microgrids. The implementation is made publicly available to facilitate its use in analyzing AC/DC hybrid grids.

0.36

Data-driven Linearization of Operational Dynamics of Soft Open Points in Power Distribution Networks

eess.SY ·2026-11-19 ·Shoaib Hussain, Mostafa Farrokhabadi, Hamidreza Zareipour
hot direction similarity 0.59
Abstract · 7 pages, 7 figures, 5 tables

This paper proposes a novel data-driven linearization of operational power losses in a Soft Open Point (SOP). The proposed learning-based representation, combined with the standard segmentation of the quadratic device capacity inequalities, linearizes the operational dynamics of SOPs in unbalanced power distribution network applications without a significant drop in power loss estimation accuracy. The technique was tested in three applications using a three-phase extension of the IEEE 33-bus network. The case studies include a sizing application for a multi-terminal phase-changing soft open point (PCSOP), an operational optimization application for an active distribution network featuring a PCSOP, and a system simulation engine built for a Deep Reinforcement Learning (DRL) application that trains an agent to optimally dispatch a PCSOP in an unbalanced distribution network. The results of the three case studies were validated against the standard nonlinear AC load-flow representations and point to the efficacy of the proposed solution.

0.41

Fixed-Time Voltage Regulation in Distribution Networks with Impedance Awareness

eess.SY ·2026-10-01 ·Nilanjan Roy Chowdhury, Venkatesh Sarangan
similarity 0.59
Abstract · 8 pages, 6 figures

This letter introduces an optimization-based fixed time control algorithm for solving the voltage regulation problem of a radial and balanced power distribution network. The proposed algorithm requires no prior knowledge of the exact network impedance (resistance and reactance), yet guarantees voltage convergence to the predefined safe limit within a fixed time-window. We embrace results from Fixed-time stability (FxTs) and Control Lyapunov function (CLF) to analyze the stability and robustness of the underlying algorithm and then synthesize it leveraging the Quadratic Programming (QP) approach. We first analytically provide sufficient conditions on the control gains and the design parameters, that can ensure voltage regulation in fixed-time. Thereafter we transform the existing voltage regulation problem into an equivalent QP-based optimization framework and translate the aforesaid conditions to find feasible solutions for voltage stability. We empirically verify the efficacy of our proposed algorithm on the IEEE-33 bus distribution network and compare its performance against other existing robust control methods.

0.29

Modeling of Network Constraints in Large-scale Capacity Expansion Optimization of Power Grids

eess.SY math.OC ·2026-08-28 ·Yu Weng, Lara Booth, Priya L. Donti, Ruaridh Macdonald
publishedtheoryhot direction similarity 0.58
Abstract

Capacity expansion modeling plays a critical role in optimizing the deployment of new generation, storage, and transmission, typically at national and regional levels. To support long-term planning, these models consider a large set of energy technologies and policies, along with decades of weather and demand data. Realistic capacity expansion models thus become high-dimensional optimization problems, with hundreds of millions of variables and constraints, which are challenging to solve. A common strategy to address this complexity is to omit non-linear, non-convex AC optimal power flow (ACOPF) constraints and instead use linearized power balance equations or transport formulations. While these simplifications improve tractability, they limit our understanding of how power flow and the physical properties of power networks impact investment decisions across generation, storage, and transmission infrastructure. This paper addresses this gap by extending the GenX capacity expansion model to incorporate fixed point theorem-based network constraints. These embed ACOPF-based considerations while maintaining the tractability of the planning model, nearly preserving the dimensionality of the transport formulation and incurring only modest runtime increases. This approach is much cheaper than embedding ACOPF directly, making it appropriate for large-scale capacity planning problems. We compare our approach to the original transport-based GenX model as well as a non-linear, non-convex version that incorporates the full ACOPF constraints, for a case study of the ISO New England grid.

0.47