CS Paper Radar

A Bayesian Adaptive Spectral Surrogate Model for Efficient Probabilistic Optimal Power Flow Evaluation

Xiaoting Wang, Xiaozhe Wang, Gregory Kish, Yunwei, Li

eess.SY ·submitted 2026-09-01 01:32 UTC · v1
top venue

Abstract

This paper presents an adaptive stochastic spectral embedding (ASSE) method to solve the probabilistic AC optimal power flow (AC-OPF), a critical aspect of power system operation. The proposed method can efficiently and accurately estimate the probabilistic characteristics (e.g., mean, variance, median, and quantile-based metrics) of AC-OPF solutions while minimizing power losses. Based on estimated AC-OPF decisions (i.e., generator outputs), the confidence interval (CI)-based production cost index can be determined. Specially, an adaptive domain partition strategy is adopted to guide refinement domain selection and partition. The Bayesian compressive sensing-based coefficient calculation algorithm is integrated to enhance its performance. Numerical studies on modified IEEE 9-bus and IEEE 118-bus systems demonstrate that the proposed ASSE method offers accurate and fast evaluations compared to Monte Carlo simulations. Comparisons with a sparse polynomial chaos expansion, Gaussian process regression, and deep neural networks, further illustrate its efficacy in accurately assessing the responses with strongly localized behavior and non-symmetric distributions, providing practical decision-making bounds for generator outputs and operating costs under uncertainty.

Comment
18 pages, 15 figures. To appear in IEEE Transactions on Power Systems
DOI
10.1109/TPWRS.2026.3727456

Closest papers

Nearest neighbours by meaning across the whole index.

PowerModels-ACOPF-AI: On-the-Fly Machine Learning Approach for Solving AC Optimal Power Flow Integrating Renewable Energy Sources

eess.SY ·2026-09-16 ·Bhuban Dhamala, Jose Tabarez, Anup Pandey
benchmark similarity 0.68
Abstract

The increasing complexity of modern power systems, driven by high renewable penetration, load variability, and operational uncertainty, demands fast and reliable solutions to the AC optimal power flow problem (AC-OPF). Traditional optimization methods, though accurate, often struggle with scalability and high computational burdens, making them impractical for real-time use in large networks. This paper introduces PowerModels-ACOPF-AI, a two-stage Bayesian Neural Network (BNN) surrogate designed to predict generator set points, bus voltages, and phase angles with uncertainty. The framework integrates a performance-sensitive on-the-fly learning mechanism that identifies regions of degraded prediction accuracy and dynamically retrains with additional AC-OPF solutions generated by PowerModels.jl. This self-adaptive loop ensures robust performance, enabling the model to maintain accuracy under novel or highly variable operating conditions. Validation on benchmark test systems of different sizes, namely the 30-bus, 200-bus, and 500-bus networks, demonstrates strong generalization capability, efficient handling of stochastic renewable injections, and the ability to provide rapid, uncertainty-aware predictions. Beyond predictive accuracy, the proposed approach offers practical value as both a real-time advisory tool for system operators and a fast initializer for conventional solvers, thus supporting resilient and efficient grid operation in future power systems.

0.16

Bayesian Distribution System State Estimation with Flow Matching

cs.LG cs.AIeess.SP ·2026-10-29 ·Nan Lin, Peter Palensky, Pedro Vergara Barrios
similarity 0.66
Abstract · 10 pages

Medium-voltage feeders have few real-time measurements, so distribution system state estimation (DSSE) rests on pseudo-measurements of the secondary substations, a prior in Bayesian terms. Weighted least squares keeps the power flow exact but reduces this prior to a mean and variance, while supervised deep learning estimators also learn the power flow and are tied to one measurement set. We propose PoSE (posterior sampling for state estimation), which keeps the Bayesian structure of DSSE and learns only what the distribution system operator does not know, namely the distribution of substation injections, modelled by a neural network trained with flow matching on historical data. The power flow equations, grid topology and measurements enter only at sampling, through a noise-aware Kalman-type correction. The neural network therefore never approximates the power flow, but every posterior sample is a physically consistent operating point, and one trained prior serves any measurement set, noise level and topology. On the IEEE 33-bus feeder, PoSE lowers the probabilistic injection error (CRPS) by 6.7-7.5% against a full-covariance Gaussian prior in all 12 tested settings. It provides reliable uncertainty: the 90% intervals contain the true injection almost exactly as often as exact posterior samples would, whereas those of supervised estimators contain it in only 37-78% of cases. On the 240-bus unbalanced three-phase Iowa feeder, it gives the lowest injection, voltage and branch-current errors of all estimators. A fast variant matches this accuracy at 0.2-0.6s per snapshot and, without retraining, beats Gaussian priors and retrained supervised estimators on seven reconfigured topologies.

0.17

Probabilistic electrical power demand forecasting with uncertainty quantification

cs.LG cs.AI ·2026-09-28 ·Mahesh Neupane, Pragya Dhungana, Pradip Khatri, Swechhya Baskota, Hariom Dhungana
similarity 0.64
Abstract

The majority of research on electricity consumption forecasting has focused on deterministic approaches, which generate a single point estimate for each time step in the forecasting horizon. However, the increasing penetration of renewable energy sources and the growing complexity of modern smart grids have introduced greater variability and uncertainty into power-system demand and operation. Consequently, probabilistic forecasting, which quantifies the uncertainty and variability associated with future electricity demand, is becoming increasingly important for reliable power-system planning and operation. This study presents an empirical comparison of four contemporary probabilistic forecasting models for electricity consumption, highlighting their respective strengths and limitations. We have performed comparision on real-world power systems related datasets. Across all power-consumption zones, NGBoost demonstrates superior probabilistic forecasting performance, achieving the lowest MAE and RMSE while providing well-calibrated uncertainty estimates with high prediction-interval coverage and reasonably narrow intervals. These results indicate that NGBoost offers a more accurate and reliable forecasting framework than Bayesian, Monte Carlo (MC) Dropout, and Gaussian Process Regression (GPR) models for the considered electricity consumption data.

0.16

Topology-adaptive Estimation of Maximum Voltage Unbalance for Distribution Networks with Finite-sample Guarantee

eess.SY ·2026-10-14 ·Jinbao Wang, Jun Liu, Shiliang Zhang, Xuehui Ma, He Zhang
similarity 0.63
Abstract

High penetration of single-phase distributed power production and frequent topology changes can significantly increase voltage unbalance in distribution networks. Reliable probabilistic power flow (PPF) assessment for the network, therefore, must account for topology-dependent power-flow equations, numerical error in the voltage unbalance factor (VUF), and finite-sample uncertainty in power measurements. In this paper, we propose Topology-Adaptive Certified Quantile Estimation (TACQE) to estimate the maximum VUF across monitored electric buses. Following a local network change, TACQE updates the cross-couplings among power-flow sequences, and certifies candidate PPF solutions against the updated nonlinear equations. The resulted power-flow state enclosures provide rigorous bounds on the maximum VUF. Furthermore, we derive independent reference-solver evaluations to calibrate discrepancies from the reference PPF solution. This leads to a uniform sampling bound that yields simultaneous upper-tail probabilities and quantiles, which provides a finite-sample guarantee for the estimated maximum-VUF distribution over an entire range of VUF thresholds. From our numerical simulations across 101 fixed-topology quantiles, it demonstrates that the designed TACQE can provide a fast candidate post-change power flow solution where it reuses most of the previous network model and modifies only the affected bus blocks.

0.17

Learning-Based Power Flow Estimation with Sparse PMU Deployment in Power Systems

eess.SY ·2026-10-09 ·Van-Hai Bui, Quang Manh Hoang, Akhtar Hussain, Wencong Su
similarity 0.61
Abstract · 14

Accurate monitoring of power flow is fundamental to the secure and reliable operation of modern power systems. Existing data-driven power flow estimation methods typically assume that synchronized measurements are available at every bus, requiring extensive deployment of phasor measurement units (PMUs). Such dense sensing infrastructures substantially increase installation, communication, and maintenance costs. This paper proposes a learning-based framework that minimizes the number of installed PMUs while maintaining high-accuracy systemwide power flow estimation. Instead of relying on measurements from all buses, the proposed method identifies an informative subset of buses whose synchronized measurements are sufficient to accurately reconstruct branch power flow across the network. To this end, a neural network is developed to learn the nonlinear relationship between PMU measurements and system-wide power flows, and multiple PMU deployment scenarios are evaluated to quantify the trade-off between measurement availability and estimation accuracy. The results enable utilities to identify cost-effective PMU placement strategies that balance deployment cost and prediction performance. Case studies on the IEEE 30-bus test system demonstrate that the proposed framework significantly reduces the number of required PMUs while maintaining accurate power flow estimation.

0.18

Expediting AC Contingency Analysis using a Basecase Machine Learning Model

eess.SY ·2026-09-29 ·Md Obaidur Rahman, Vassilis Kekatos
similarity 0.60
Abstract · 10 page, 7 figures

Grid planning and operation under increasingly variable operating conditions require fast and accurate AC power flow (AC-PF) contingency analysis for numerous line outages. While ML models can accelerate these computations, existing approaches often require either training separate models for different contingencies or a single model using data from multiple topologies. Both approaches incur substantial offline data generation and training costs. To address this gap, this work proposes a fixed-point framework that reuses a single ML model trained exclusively on basecase topology data to predict post-contingency AC-PF states under any non-critical single-line outage. We analyze the proposed method's convergence under the DC model approximation and derive its convergence rate in terms of network parameters. As a side result, we show that power transfer distribution factors (PTDFs) for non-critical lines have magnitudes less than one. We further characterize the ML training region to accommodate PF specifications encountered during fixed-point iterations and derive bounds on ML prediction errors for post-contingency state estimates. Numerical tests on a 6,717-bus synthetic Texas system demonstrate convergence across all non-critical single-line outages, with prediction errors remaining close to those of basecase. The proposed framework offers a favorable tradeoff between the speed of DC solvers and Newton-Raphson accuracy.

0.11

Adaptive State Estimation Under Topological Uncertainty in Unobservable Primary Distribution Systems Using Strategically Placed Sensors

eess.SY ·2026-09-23 ·Farah Elsherif, Behrouz Azimian, Anamitra Pal
published similarity 0.59
Abstract · 6 pages, 6 figures, 4 tables. Accepted for presentation at the 2026 North American Power Symposium (NAPS)

The rapid integration of distributed energy resources is fundamentally altering power flow patterns in primary distribution networks and intensifying operational uncertainty. These problems are further compounded by lack of real-time situational awareness and frequent topology changes. To address these problems, this paper proposes an integrated deep learning framework for simultaneous topology identification (TI) and distribution system state estimation (DSSE) in real-time unobservable primary distribution networks instrumented by a minimal set of synchronized measurement devices (SMDs). A correlation-driven SMD placement algorithm is introduced first that jointly satisfies TI accuracy and DSSE performance requirements by exploiting temporal and spatial correlations in nodal voltage measurements. A dual deep neural network (DNN)-based DSSE model is developed next to estimate three-phase voltage magnitudes and angles across diverse operating conditions. To extend the framework beyond the base topology, fine-tuning-based transfer learning is employed to adapt the DSSE model to reconfigured topologies using limited retraining data. The framework is validated under both Gaussian and non-Gaussian measurement noise and benchmarked against a conventional estimation approach and a single DNN model.

0.35

Benchmarking a Grid Foundation Model for AC Optimal Power Flow: Feasibility and Warm-Start Results on Synthetic Texas and South Carolina Grids

eess.SY ·2026-11-17 ·Tam Kemabonta, Brighton Ombuki, Vladimir Abdelnour
similarity 0.59
Abstract · 5 pages, 3 figures, 2 tables. Submitted to the 2027 IEEE PES General Meeting

Learning-based surrogates for alternating-current optimal power flow (AC-OPF) are often judged by the gap between their objective value and that of a nonlinear solver, which does not show that a prediction satisfies power balance and network limits. This paper tests whether predictions from the pretrained foundation model GridSFM-Open 1.1.0, recently released by Microsoft, are feasible AC-OPF operating points and whether they are useful initial values for a nonlinear solver. The model was evaluated zero-shot and after fine-tuning on 10, 100, and 1,000 labeled scenarios (FT10, FT100, and FT1000) on 500 scenarios for each of two synthetic grids, ACTIVSg2000 (Texas) and ACTIVSg500 (South Carolina), with Ipopt, MATPOWER MIPS, and pandapower PIPS as solver references. The lowest Texas median cost gap, 0.44\% for FT100, coincided with thermal violations in 24.1\% of cases and a median maximum bus power mismatch of 89 MW and 197 Mvar. Texas zero-shot predictions had a median maximum mismatch of 648 MW and 1,641 Mvar, and every South Carolina case violated a thermal limit for every model variant. Seeding Ipopt with FT1000 predictions gave geometric-mean solve-time speedups of 1.55x on South Carolina and 1.12x on Texas (p = 0.06, not significant at the 5\% level), while zero-shot seeds slowed South Carolina solves (0.26x). A small objective gap therefore did not indicate feasibility: although median zero-shot inference took only 1.32 s on Texas and 0.157 s on South Carolina on a shared host, every prediction still required a nonlinear solver, and fine-tuned predictions gave modest, grid-dependent warm-start speedups while zero-shot predictions slowed convergence on one grid. GridSFM may therefore be useful for initializing a nonlinear solver, but obtaining feasible AC-OPF solutions still required the solver.

0.18