CS Paper Radar

KneeFS-Net: A Lightweight Deep Learning Model for Knee Osteoarthritis Severity Assessment with Cross-Domain External Validation

Shafqat Alam, Galib Anjum Talukder Mahi, Yeasir Rabbani Tanvir, Md. Ibrahim, Md. Shahed Hossain, Shashank Ghimire, Mahmud Hasan Mostofa Kamal, ASM Shahidul Hossain, Taufiq Hasan

cs.CV cs.LG ·submitted 2026-11-15 12:56 UTC · v1

Abstract

Knee osteoarthritis (OA) grading from radiographs using the Kellgren-Lawrence (KL) scale requires expertise that may be scarce. We present KneeFS-Net, a lightweight ordinal grader (0.8 million parameters; 0.33 GFLOPs) combining spatial, Fourier and state-space features with landmark-guided attention. On the Osteoarthritis Initiative (OAI) test set, KneeFS-Net achieved a quadratic weighted kappa (QWK) of 0.863, mean absolute error (MAE) of 0.325 and 97.2% within-one-grade accuracy, comparable to models with 9-35-fold more parameters. We evaluated cross-population generalization on two Bangladeshi cohorts, a single-center hospital cohort and a multi-center teleradiology cohort. Without further training or adaptation, the OAI-trained model achieved QWK 0.803, MAE 0.339 and 98.2% within-one-grade accuracy on its hospital cohort, declining to QWK 0.656 and MAE 0.522 on multi-center teleradiology images. Self-supervised pretraining on 6,092 unlabeled radiographs followed by joint fine-tuning achieved QWK 0.823, MAE 0.329 and 99.7% within-one-grade accuracy in cross-validation. These findings demonstrate accurate, efficient KL grading and potential adaptation to new populations with limited annotation.

Comment
23 pages, 6 figures, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Knee3DVLM: Dual-Sequence Full-Volume Vision-Language Modeling for Comprehensive Knee MRI Assessment

cs.CV cs.AI ·2026-10-06 ·Maryam Baizhigitova, Andrew Seohwan Yu, Po-Hao Chen, Naveen Subhas, Sixu Chen +5 more
similarity 0.67
Abstract · 11 pages, 2 figures, 5 tables

Vision-language models (VLMs) are increasingly being applied to three-dimensional medical imaging, but their application to knee MRI remains limited, particularly for interpreting the complementary sequences used in clinical practice. We introduce Knee3DVLM, a sequence-aware VLM that uses full-volume DESS and fluid-sensitive TSE MRI to predict 57 anatomically resolved binary diagnostic targets derived from the MRI Osteoarthritis Knee Score (MOAKS) for structured reporting. We evaluated DESS-only, TSE-only, and paired DESS-TSE configurations using subject-disjoint Osteoarthritis Initiative partitions. In a held-out cohort of 1,074 examinations, the fused model achieved 72.98% average accuracy, 71.17% balanced accuracy, 78.96% mean ROC-AUC, and 78.74% macro ROC-AUC, the highest values among the three configurations. In a secondary multiclass analysis aligned with the released 3DReasonKnee cohort, Knee3DVLM was numerically higher than the strongest reported 3DReasonKnee configuration across five pathology categories. These findings support dual-sequence full-volume modeling for comprehensive knee MRI assessment.

0.23

KneePreM: Towards 3D Knee MRI Foundation Models via Large-Scale Unlabeled Pretraining and Label-Efficient Fine-Tuning

cs.CV ·2026-09-25 ·Xinxin Wang, Liam Hazan, Jing Li, Simona Rabinovici-Cohen, Xiaojuan Li +1 more
similarity 0.64
Abstract

Background: Large volumes of unlabeled knee MRI scans are available across repositories but remain insufficiently leveraged. We developed KneePreM, a knee-specific 3D self-supervised model, and evaluated transfer and label efficiency for classification and segmentation. Methods: A 3D U-Net masked autoencoder was pretrained on 19,011 unlabeled Osteoarthritis Initiative (OAI) MRI series from 4,791 participants. Downstream fine-tuning used full and reduced training sets for fastMRI+ two-label classification (1,172 examinations), Arthroscopic Partial Meniscectomy (APM) eight-target classification (1,716 examinations), SKM-TEA segmentation (155 examinations), and APM segmentation (25 examinations). Baselines were random initialization and SuPreM. Deployment workflow was implemented with a Model Context Protocol interface. Evaluation metrics included balanced accuracy, F1 score, ROC AUC, PR AUC, and Dice score. Statistical analysis used bootstrap confidence intervals and paired bootstrap tests for classification and Wilcoxon signed-rank tests for segmentation. Results: KneePreM achieved higher full-data macro ROC AUC than both baselines for fastMRI+ and APM (all p < .001). For fastMRI+ classification, KneePreM achieved a ROC AUC of 0.722 using 50% of the training data, exceeding both full-data baselines. In APM classification, KneePreM reached a ROC AUC of 0.740 with 70% of the data, matching the full-data random baseline and outperforming SuPreM. For SKM-TEA segmentation, its 70%-data Dice of 0.838 exceeded the full-data random baseline (0.835) and both same-budget comparators. In APM segmentation, its 75%-data Dice of 0.746 exceeded the full-data random baseline (0.731) and both same-budget comparators. Conclusion: KneePreM improves transfer performance and label efficiency across knee MRI classification and segmentation tasks, particularly when labeled training data are limited.

0.34

Report-Derived Labels, an Image Teacher and the Gap to Expert Labels in Knee MRI: An Analysis of One Entry to the RSNA 2026 Knee Abnormality Detection Challenge

eess.IV ·2026-10-28 ·Soheil Kooklan
benchmarkcode/data similarity 0.64
Abstract · 24 pages, 10 figures, 14 tables. Code: https://github.com/soheilkooklan/rsna-knee-report-labels

In the RSNA 2026 Knee Abnormality Detection challenge, 58 of 4,407 training studies have expert labels for 12 findings, and the rest have only a radiology report. We compare training targets built from a language-model reading of the reports and from a public image model against two references: the expert labels and the 39,248 study-finding cells that the reports state as present or absent. The report labels and the out-of-fold predictions of the image model reach similar agreement with the expert labels (macro AUC 0.892 and 0.896) but fail on different findings. The report is better for ligament tears and patellofemoral osteoarthritis, which it never calls present when the experts do not; the image model is better for effusion, Baker's cyst, contusion, and synovitis, where the reports call the finding absent, leave it out, or call it present more often than the experts. Their equal mixture reaches 0.927 (gain over the report labels 0.035, 95% interval 0.019 to 0.052), also after removing the studies whose knee side was handled inconsistently. We did not observe a model-level gain from this better target: a 2.5D ResNet50 trained on the report labels alone scored 0.877 on the private leaderboard, after the deadline, against 0.872 for the same model trained on the mixture, and the out-of-fold advantage of the mixture is confounded by a change of code and by possible leakage through the image model's folds. A scanner prevalence prior raised agreement with the reports but not with the experts, so a report-derived reference can reward reporting habits. A rank correction for co-occurring findings gave small out-of-fold gains and no visible leaderboard effect. Our entry, a forked public ensemble with that correction, was displayed at rank 582 of 6,299 on the private leaderboard (0.943, a score shared by 287 teams). All results are exploratory; none of the models is meant for clinical use.

0.41

CS-LDM: Clinically Guided Structure-Aware Latent Diffusion for Knee Radiographic Forecasting

eess.IV ·2026-10-29 ·Shaotian Li, Chenhui Wang, Wenhua Wu, Yanqiu Wu, Xiaohan Yu
similarity 0.62
Abstract

Knee osteoarthritis (KOA) is a leading cause of physical disability and currently has no curative clinical treatment. Early diagnosis and accurate prognosis are therefore vital for managing its progression. Existing methods mainly predict future severity grades and provide limited visual explanation of structural change. Recent generation-guided approaches synthesize follow-up radiographs for progression assessment, but generated images are often judged by predictive accuracy or image realism, so they may satisfy a grading model while remaining morphologically unreliable. We therefore propose CS-LDM, a clinically guided, structure-aware latent diffusion framework that forecasts patient-specific future knee radiographs from the current X-ray and clinically available current KL grade, using LoRA adaptation, current-grade conditioning, and frozen-teacher diagnostic distillation. Experiments on the public Osteoarthritis Initiative (OAI) dataset show that CS-LDM improves future severity-grade consistency while maintaining competitive image fidelity. Further ordinal, OARSI, ROI-level, and stable/progressed analyses show that radiographic forecasting should be evaluated by balancing diagnostic consistency, anatomical plausibility, and structural preservation.

0.20

How well do routinely collected demographic and clinical variables aid point-of-care lung ultrasound TB classification

eess.IV cs.CVcs.LG ·2026-10-05 ·Joshua M. Jansen van Vüren, Christiaan M. Geldenhuys, Devendra S. Parihar, Véronique Suttels, Trevor Brokowski +5 more
published similarity 0.61
Abstract · Accepted: SATNAC, Drakensberg, South Africa, 2026

We consider the fusion of lung ultrasound images with routinely-collected clinical and demographic data for the purpose of automated tuberculosis (TB) screening using deep-learning. Such deep-learning based screening tools for TB could meaningfully support the health care system in Africa, where the burden of disease is severe and resources are constrained. Beginning with an established ResNet baseline for classification of lung ultrasound images, which achieves an area under the receiver operating characteristic (AUROC) curve of 0.91 [0.86,0.96] (95% CI), we consider the incorporation of the clinical and demographic data using three fusion approaches. We find that a simple average-based fusion of the output scores of separately-trained image and clinical data classifiers consistently matches or outperforms a more complex approach where the data is fused earlier and a combined classifier is trained. Fusing the image and the clinical classifiers in this way leads to a classifier with an overall AUROC of 0.95 [0.91,0.99] (specificity of 0.76 at sensitivity 0.93) which is an improvement of 4% absolute over the image-only baseline. We also find that greedy feature selection can be used to reduce the number of clinical and demographic inputs without sacrificing classification performance. Finally, when we differentiate between clinical and demographic data that are self-reported, that require some basic measurement or calculation, and that require a point-of-care (POC) test, we find the inclusion of the POC tests included in this study to be of minimal benefit to classification performance. We conclude that the incorporation of routinely-collected clinical and demographic data is a promising way to improve the performance of lung ultrasound based automatic classification.

0.25

Acute Stroke Classification Using Asymmetric Data Standardization and Orthogonal-Focal Loss Optimized CNN-ViT Cross-Attention Fusion: A Multicenter External Validation Study

eess.IV cs.AI ·2026-10-25 ·Tansel Uyar
code/data similarity 0.60
Abstract · All research data has been uploaded to Zenodo (DOI: 10.5281/zenodo.22132268). The data presented in this study are available on request from…

Background/Objectives: Rapid differentiation of ischemic and hemorrhagic stroke subtypes is vital for acute management. Although current deep learning models achieve high single-dataset accuracy, they suffer from "shortcut learning" and domain shift in external validation. This study proposes a hierarchical computer-aided diagnostic (CAD) system mimicking emergency triage. Methods: We introduce a 3-channel Radiology-Focused Preprocessing pipeline that feeds radiological Hounsfield Unit (HU) windows into Convolutional Neural Network (CNN) and Vision Transformer (ViT) backbones via asymmetric formats (.mat and .png). The architecture utilizes a novel joint cross-attention fusion network optimized by an Integrated Orthogonal-Focal Loss. Results: Our system achieved a 95.48% F1-score on the internal stroke dataset. However, multi-center external validation (AISD, BHSD, PhysioNet) using a Mask Anchor filter revealed a drop to the 58-62% range, exposing the "internal validation illusion" caused by hardware noise. Critically, models exhibited high precision (77%) but low sensitivity (57%) for ischemic stroke, proving prone to hemorrhage overdiagnosis. Multi-seed variance analysis demonstrated that the DenseNet201+ViT backbone yielded the lowest deviation (0.59) and highest stability, making it the most reliable architecture for real-world clinical integration. Conclusions: To overcome diagnostic challenges, future research must focus on multimodal architectures that combine 3D volumetric extraction with clinical data.

0.33

OA-MAP: Evidence-Grounded Multi-Agent Multimodal Framework for Interpretable Knee Osteoarthritis Progression

cs.AI cs.MA ·2026-10-08 ·Sixu Chen, Mingrui Yang, Qiang Guan, Xiaojuan Li
similarity 0.59
Abstract

Knee osteoarthritis (KOA) progression prediction can support patient monitoring, requiring the integration of multimodal data and multidomain expertise. Moreover, isolated risk estimates provide limited insight underlying a prediction. To automate the progression assessment workflow and reduce manual effort while providing interpretable findings and supporting evidence, we present OA-MAP, an autonomous multi-agent framework for evidence-grounded assessment of structural and pain progression in KOA. The system incorporates modality-specific agents including MRI, X-ray, and clinical agents, together with a coordinator agent. This framework can autonomously recruit specialist agents, select tools for prediction and analysis, and retrieve literature as external evidence based on user request and available patient information. An uncertainty-informed human-in-the-loop mechanism enables clinicians to review and correct intermediate findings, triggering recomputation of affected results. We evaluate the prediction models using 600 participants from the FNIH Osteoarthritis Biomarkers Consortium cohort. On the test set of 100 participants, the fusion models achieve AUROCs of 0.80 for structural progression and 0.68 for pain progression. A case study illustrates how OA-MAP combines risk estimates with intermediate findings, cross-modal conflicts, literature support, and uncertainty indicators to support interactive review.

0.18

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
similarity 0.58
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.06