CS Paper Radar

Medical question answering collapses in Hausa: a pre-registered pilot on three small open models

Abbas Sani

cs.CL ·submitted 2026-11-16 10:06 UTC · v1
benchmark

Abstract

A system that reads nothing and always answers the most frequent letter scores \BaselineP{} on our Hausa medical multiple-choice set. \NBelowBaseline{} of the \NModels{} small open models we evaluate do not beat it. We lead with that because the usual summary of a multilingual result -- a percentage-point drop from English -- does not say whether what survives the drop is performance at all. On a paired English--Hausa set of \NEval{} MedMCQA items, three instruction-tuned models of 3--4B parameters lose between \GapMedGemma{} and \GapQwen{} points of accuracy, every gap significant after Holm correction. Back-translating the Hausa items into English recovers between half and two-thirds of the gap for the two general-purpose models but not demonstrably for the medically adapted one, so the deficit is substantially, though not wholly, a matter of the language of presentation. Answers are also far less stable: agreement across three option orderings falls from \ConsEnQwen{} to \ConsHaQwen{} in the worst case. An exploratory error analysis of \ENRows{} discordant items attributes most of the damage to medical vocabulary lost in translation (\ETerm{}, 95\% CI \ETermLo{}--\ETermHi{}), usually in the question stem. A fourth registered hypothesis proposed closing the gap with self-generated preference pairs. Its pilot gate found nothing to train on: asked to reason in Hausa rather than to pick a letter, the model echoes the prompt back, switches into Swahili, or simply stops without answering; only \GateParse{} of chains are parseable. We report that intervention as not run, which is itself the sharper result -- a forced-choice benchmark cannot see a model that has no generative command of the language at all. All hypotheses, thresholds and decision rules were registered before any model was run, and all deviations are logged.

Comment
10 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.66
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.64
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.09

Would an LLM Match into a Residency? Uncertainty, Reasoning and Image Use of Open Language Models on the Spanish MIR Examination

cs.CL cs.AIcs.CYcs.LG ·2026-10-22 ·Miguel Fernandez-de-Retana, Unai Zulaika, Ruben Sanchez-Corcuera, Aritz Bilbao-Jayo, Aitor Almeida
hot direction similarity 0.64
Abstract · 13 pages, 8 figures

Accuracy on medical examinations is common evidence offered for the clinical use of language models, yet a health system that intends to run an open model on its own hardware needs to know considerably more: whether the model recognizes when it is likely to be wrong, whether medical fine-tuning improves this ability, whether its correct answers rest on sound clinical reasoning, or whether it actually uses the images it is given. We examine these questions for four open models of 8 to 27 billion parameters on the Spanish MIR residency examination, scoring 1,552 questions from eight editions under the exam's own rules. Answering every question, the three larger models would rank among roughly the first 600 to 3,000 candidates, with 41 to 43 specialties still open to them. Abstention, however, never pays, because even their least confident answers are right more often than the 25% break-even. Medical fine-tuning reduced overconfidence at the cost of accuracy, without improving how well confidence separates right from wrong answers. Moreover, 13-38% of correct answers rejected a distractor for a clinically unsound reason that confidence did not reflect, and removing or swapping the provided contextual images left accuracy unchanged.

0.34

Calibration and Conformal Prediction for Medical Question Answering in Arabic and English: Evidence from Two Non-Parallel Benchmarks

cs.LG ·2026-11-12 ·Mariya
code/data similarity 0.64
Abstract · 15 pages, 1 figure, 12 tables. Code: https://github.com/Mariyaaleem/arabic-english-medqa-uncertainty

Large language models (LLMs) are increasingly tested on medical exam questions, but accuracy alone does not show when an answer can be trusted. I study the calibration and uncertainty of two open-weight models, Qwen2.5-7B-Instruct and Jais-adapted-7B-chat (both run in 4-bit precision), on 2,816 English multiple-choice questions from MedMCQA and 4,927 Arabic multiple-choice questions from MedAraBench. Accuracy was 0.561 (English) and 0.430 (Arabic) for Qwen, and 0.369 and 0.308 for Jais. Raw option probabilities were overconfident in all four settings (expected calibration error 0.242 to 0.486), and a single temperature parameter removed 82% to 93% of that error. Split conformal prediction reached its nominal coverage in all 24 settings I tested (within 0.006), but the sets were large when accuracy was low: at 90% coverage, temperature-scaled sets contained on average 63% (Qwen, English), 78% (Qwen, Arabic), 86% (Jais, English) and 89% (Jais, Arabic) of the options. The margin between the top two option probabilities separated correct from incorrect answers best for Qwen on English (AUROC 0.734) and worst for Jais on Arabic (0.579). Answering only the 20% most confident questions lowered Qwen's English error from 0.439 to 0.098. Jais showed a strong prior for option C (49% of English and 60% of Arabic predictions). Scoring Latin letters only cut the Arabic share to 29% but left accuracy, raw ECE and AUROC nearly unchanged. Because the two benchmarks differ in subject, level and number of options, I do not attribute differences between languages to language itself. Code is available at https://github.com/Mariyaaleem/arabic-english-medqa-uncertainty.

0.35

CLADE: Category-Level Answering from Deficient Evidence in Retrieval-Augmented Language Models

cs.AI ·2026-11-10 ·S M Rayeed, Charles V. Stewart, Yao Ma
position similarity 0.62
Abstract

Retrieval-augmented systems often retrieve passages that are accurate and relevant but state the answer at a coarser level of granularity than the question requires. For example, a question may ask which specific disease a drug treats (familial hyperlipidemia), while the retrieved passage mentions the broader disease family (hyperlipidemia). Prior work on context sufficiency treats such coarse passages simply as insufficient. We argue that they form a distinct case, which we call resolvable insufficiency: text alone cannot settle the fine-grained answer, but the broader category it mentions maps to a short list of candidate answers in a domain ontology. When language models read these coarse, family-only passages, they exhibit a phenomenon we call Clade (Category-Level Answering from Deficient Evidence): they answer instead of abstaining or searching further. On biomedical questions from PrimeKG, family-only passages reduce abstention by 13.8 points compared to uninformative passages, and the resulting guesses are wrong about half the time. A counterfactual test confirms the cause: replacing an exact disease name with its broader family name lowers abstention by 17.4 points compared to deleting the sentence. Simple fixes like confidence filtering, scaling to a larger model, and explicitly instructing the model to abstain cannot resolve Clade, and this replicates on ecological species interactions in GloBI. Finally, we test whether an ontology can turn coarse passages into exact answers. Given the correct family, an ontology list includes the true answer in 98.5% of cases, but string matching finds that family on the page for only 19.8%. Letting the model choose the family raises this to 30.0% and end-to-end recovery from 10.0% to 26.8%. Overall, our results show when language models should stop guessing and consult an ontology, and highlight which steps of that process remain unsolved.

0.32

A System 1 Decision Model for Medical Multiple-Choice Questions Built on Frozen Language Models

cs.AI cs.CL ·2026-11-18 ·Pavan Kumar Mantha
hot direction similarity 0.62
Abstract · 12 pages with 7 tabular explanations

A System 1 model answers a multiple-choice question in a single pass. A frozen language model turns the question and each option into vectors, two small, trained heads place them in a shared space, and the closest option wins. The design has been shown on agent decisions, but we are not aware of a study of how far it goes on exam questions that need medical knowledge, where the right option is often no more similar to the question than the wrong ones. We rebuilt the recipe from scratch for MedMCQA and trained only two projection heads and one temperature on top of frozen Qwen3.5-0.8B, Granite-4.2-3B and Qwen3-8B, using a contrastive loss with in-batch and hard negatives and a mask for repeated answers. With plain last-token vectors, both small encoders answer about one question in three correctly (33.1% and 33.0% on 3,842 held-out questions, where chance is 25.0%). Writing each text inside a one-word-summary prompt and lowering the learning rate of the heads raised this to 41.7% and 42.5% for the two small encoders and to 46.0% +-0.2 (three seeds) for Qwen3-8B. Shuffling the questions against the options returns accuracy to chance, so the heads do use the question. Flan-PaLM and Med-PaLM 2 report 57.6% and 72.3% on MedMCQA under a different protocol, so ours is a cheap, fast baseline and not a competitive system. We also say what our evidence cannot show: validation gains were about 1.7 to 2 times the test gains, and we could not separate the effect of reading several encoder layers from the other changes.

0.35

MamaReason: Unfinished Reasoning and Answer Recovery in Clinical Language Models

cs.CL ·2026-11-13 ·Thanni Adewuyi, Adepoju Jeremiah Moyondafoluwa, Dorcas Amapu, Dieko Whenu, Sylvia Essessien +6 more
similarity 0.61
Abstract

Answer continuation often returns a diagnosis already stated in unfinished clinical reasoning. We study this behavior in MamaReason, adapted from dense Gemma 4 31B, on MamaBench's 217 paired maternal and child-health presentations. An explicit-commitment extractor identifies a diagnosis in 75 of 94 failed RL first passes and 75 of 93 failed SFT first passes. The continuation matches that diagnosis in 67/75 RL cases and 58/75 SFT cases, using diagnosis strings alone. Reading these commitments without additional generation recovers 30 of the 40 RL pairs restored by continuation under the archived correctness labels. Recurrence controls distinguish routine mentions from repeated answer selection. An offline second-commitment trigger measures the tradeoff between earlier readout and paired accuracy. The resulting decomposition separates diagnostic content already present in a trace, completion of an accepted answer, and paired diagnostic correctness. For clinical language-model evaluation, these are distinct outcomes that become visible when the same reasoning trace is examined through multiple readouts.

0.25

Benchmarking decision models against generative large language models on medical multiple-choice questions

cs.CL cs.AI ·2026-10-28 ·Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert +1 more
similarity 0.61
Abstract

Medical workflows often require selecting among predefined options. We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions. Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations. Among the tested configurations, Mercury Decide had the lowest mean final-attempt cost (USD 0.0069 per 1,000 questions), while Clef Omni had the shortest median request duration (0.291 seconds). Decision-model probabilities distinguished correct from incorrect answers, but error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied. Decision models offered resource advantages alongside lower peak accuracy; selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.

0.22