RetiDual-Select: Reliability-Aware Specialist-Generalist Routing for Retinal OCT under Image-Quality Shift

Zihao Han, Philippe De Wilde

cs.CV ·submitted 2026-11-17 02:59 UTC · v1

Abstract

Adaptive fusion can repair a static ensemble's errors, but can also overturn correct decisions. RetiDual-Select combines retinal specialist RETFound with the image encoder of the medical vision-language model MedSigLIP, separating candidate fusion, routing safety and predictive review. Calibrated product-of-experts (PoE) fusion is the static reference, a small gate proposes an alternative for each image, a validation-frozen harm guard decides whether that candidate may replace the reference, and a separate score prioritizes review. Static PoE reached the highest or joint-highest clean accuracy on all three datasets. At a clean 2% accepted-error target the review policy accepted 94.3% of Kermany-4 images at 99.89% selective accuracy, and 92.4% of OCT-C8 at 98.65%. Both branches were correct on 95.0% and 91.8% of clean images; only 4.4% and 6.2% had exactly one correct branch. Across 15 prespecified synthetic conditions, adaptive gains were concentrated in severe contrast reduction, where this routing opportunity widened roughly ninefold; percentile rescaling largely removed the effect, linking it to compressed dynamic range. In post-hoc validation-only analyses, gain was higher when the gate followed the more reliable branch, and a frozen guard cut the worst-condition OCT-C8 loss from 1.39 to 0.36 percentage points. Adaptive routing was useful when image quality created a reliability opportunity and the gate followed it; otherwise the system retained Static PoE or deferred for review. The findings are bounded by the synthetic perturbations evaluated and do not establish robustness to natural acquisition or scanner shift.

Comment
4 figures, 4 tables, 42 references. Submitted to the IEEE for possible publication. Main article only; the separate Supplementary Information is not included

Closest papers

Nearest neighbours by meaning across the whole index.

RetinaGuard: Risk-Controlled Agentic Triage for Multi-Disease Retinal Screening

cs.AI ·2026-11-07 ·Sohaib Sulman, Muhammad Atif Saeed, Akhtar Jamil, Alaa Ali Hameed, Roland Aydin
similarity 0.66
Abstract

Retinal screening programmes need to know which automated decisions can be accepted without review. This paper presents RetinaGuard, an agentic triage framework in which quality, diagnostic, uncertainty, verification and explanation agents gather evidence for each fundus photograph, a learned failure predictor estimates the probability that the decision is unsafe, auxiliary tools are invoked only when their expected value of information exceeds their cost, and the acceptance threshold is certified by conformal risk control. On the RFMiD test split, RetinaGuard was compared with confidence and calibrated-uncertainty referral at matched referral budgets and equal certified safety, using two RETFound primary models of different strength. With the weaker model (macro-AUROC 0.896), verifier disagreement added significant information, RetinaGuard captured 119 of 280 unsafe decisions at a 20% budget against 88 for lowest-confidence referral, and at a nominal 5% unsafe level it accepted 37.0% of cases against 10.3%. With the stronger model (0.925) the verifier added nothing beyond uncertainty and the advantage shrank to a few percentage points. In both settings its coverage at the nominal 5% level stayed near 37.7%, gating cut computation by about 30%, and a quality agent reduced unsafe acceptances under most image corruptions. The benefit of agentic evidence gathering thus depends on how much the primary model's own uncertainty already reveals about its errors.

0.25

Explainable Diabetic Retinopathy Classification Using Vision Foundation Models

cs.CV cs.LG ·2026-08-28 ·Abhishek Verma, Anila Krishna, Abhishek Gajanan Bankar, Juan Miguel Lopez Alcaraz
code/data similarity 0.62
Abstract · 17 pages, 4 figures, source code under https://github.com/UOLMDA26/retinopathy_vision_foundational

Diabetic retinopathy (DR) is a leading cause of preventable blindness, and automated screening must be both accurate and trustworthy. We study an explainable DR classification framework built on vision foundation models and three transfer learning strategies. Three backbones, DINOv2, CLIP, and Vision Transformer (ViT), were adapted by full fine-tuning, linear probing, and Low-Rank Adaptation (LoRA). Models were trained and internally evaluated on the ODIR dataset and externally evaluated on APTOS to assess generalization. DINOv2-LoRA achieved the highest internal AUROC (0.758), whereas DINOv2 and ViT full fine-tuning achieved the highest external AUROC (0.920). Probability calibration was assessed with reliability analysis after isotonic regression. For explainability, Grad-CAM and HiResCAM maps were compared with expert-annotated lesion masks from the IDRiD dataset using Dice, Intersection over Union (IoU), and Pointing Game metrics. The results show that foundation models, particularly DINOv2, provide strong predictive performance, and that LoRA is a parameter-efficient alternative to full fine-tuning. Spatial overlap between explanation maps and annotated lesions was limited (mean Dice of about 0.13 for the combined lesion mask), which highlights the value of quantitatively testing whether model attention corresponds to clinically relevant retinal lesions.

0.23

Beyond Accuracy: Benchmarking Uncertainty Quantification in Retinal Disease Screening

eess.IV ·2026-11-17 ·Mahvash Jebeli, Mohammad Eslami, Nazlee Zebardast, Lucia Sobrin, Tobias Elze
benchmarkdataset similarity 0.61
Abstract

Reliable uncertainty quantification (UQ) is essential for evaluating retinal AI systems beyond classification accuracy, yet it remains unclear whether existing UQ strategies generalize across diseases, model architectures, and reliability criteria. We introduce a large-scale, multi-disease benchmark comprising over $242,000$ fundus photographs from $32$ datasets covering diabetic retinopathy, age-related macular degeneration, and glaucoma. We evaluate six representative UQ strategies across three Vision Transformer configurations, assessing discrimination, probabilistic calibration, selective prediction, and conformal prediction-set coverage. Our findings reveal no universally superior model or UQ strategy: methods that improve reliability in one disease or architecture may underperform in another, while improvements in discrimination, calibration, and selective prediction do not necessarily align. Notably, computationally intensive methods do not consistently outperform simple confidence scores, and domain-specific foundation models and calibration-oriented loss functions do not guarantee greater reliability. In contrast, conformal prediction provides a complementary framework for achieving near-nominal marginal prediction-set coverage across diverse settings, subject to its statistical assumptions. These findings challenge universal UQ recommendations and highlight the need for disease-specific, model-specific, and multidimensional reliability evaluation before clinical deployment. We release standardized dataset splits, trained checkpoints, evaluation code, and an interactive research demonstration to support reproducible benchmarking.

0.06

From Canon to Nikon: Camera Domain Shift and Potential Equity Implications in Retinal AI

cs.CV cs.CY ·2026-10-21 ·Lisa Y. W. Tang
similarity 0.61
Abstract

Diabetic retinopathy is a leading cause of preventable blindness, yet access to regular screening remains limited worldwide. AI offers a scalable approach, but its performance can be sensitive to image quality and acquisition conditions. In a Brazilian cohort of 8,524 patients, retinal images acquired with the Nikon NF5050 were more than twice as likely to have inadequate image quality compared with those acquired with the Canon CR-2, despite refurbished Canon systems costing more than twice as much as Nikon systems. This potential cost-quality trade-off highlights an important consideration for the reliability of AI systems deployed across heterogeneous imaging systems. Using a frozen pretrained retinal foundation model, we systematically evaluate whether camera-associated performance differences persist across 12 retinal disease classification tasks, four input resolutions, and five downstream classifiers. We find that camera-associated performance differences vary substantially across tasks, and that neither higher input resolution nor classifier choice consistently mitigates cross-camera variation. These findings identify camera platform as a potentially overlooked source of performance variability, with implications for the safety and reliability of retinal AI when deployed across heterogeneous imaging systems. We release all source code, evaluation scripts, and per-task results on GitHub to support reproducible benchmarking.

0.24

Lesion-Aware Explainable AI for Diabetic Retinopathy Grading from Fundus Images

cs.CV cs.AI ·2026-11-14 ·Truong Thinh Nguyen, Hai Phong Nguyen, Truong Thanh Hung Nguyen, Giang Son Tran, Hung Cao
similarity 0.59
Abstract · 12 pages, 6 figures, 9 tables. Truong Thinh Nguyen and Hai Phong Nguyen contributed equally. Corresponding author: Truong Thinh Nguyen

Post-hoc explanations of deep-learning models for diabetic retinopathy (DR) grading are difficult to trust because different attribution methods highlight different retinal regions for the same image, and a visually plausible heatmap does not show that the highlighted pixels drive the prediction. We propose the Consensus-Calibrated Explanation Map (CCEM), which fuses Grad-CAM++, Ada-SISE, and SmoothGrad Integrated Gradients (SG-IG) using image-specific weights derived from annotation-free reliability cues: deletion sensitivity, inter-method agreement, compactness, retinal containment, and peak structure. CCEM explains a frozen ordinal grader, an EfficientNet-B7 with CBAM and a scalar regression head, pre-trained on EyePACS 2015 in Stage 1 and fine-tuned on APTOS 2019 in Stage 2 with quadratic weighted kappa (QWK)-optimized thresholds; it reaches a QWK of 0.920 on the hidden Kaggle test set and 0.559 on the external MAPLES-DR cohort. Explanations are evaluated on MAPLES-DR, 198 MESSIDOR images with expert pixel-level lesion annotations that are never used for training, threshold fitting, or fusion. On the 193 images with annotated lesions, CCEM obtains the highest Soft Pointing Game score (69.61%; 95% CI 63.7-75.3), defined as the ratio of the strongest lesion-supported saliency to the global map maximum rather than a lesion detection rate, together with the lowest deletion AUC (0.570) and the best deletion-insertion balance (0.115); each gain is significant against the strongest single explainer on paired tests. Annotation-free, per-image reliability weighting therefore turns three disagreeing explainers into one map whose peak evidence is more lesion-supported and more faithful to the model than that of any single explainer.

0.13

HierarchiRetina: A Diabetic Retinopathy Screening and Grading Cascade with Heterogeneous Mixture-of-Experts Lesion Segmentation

cs.CV ·2026-10-13 ·Md Asif Uddin, Niloy Farhan, Rafeed Rahman, Md. Golam Rabiul Alam
code/datahot direction similarity 0.58
Abstract · 8 pages, 8 figures, 8 tables. Submitted to the IEEE Journal of Biomedical and Health Informatics. Code, trained weights and per-image predic…

Clinical screening for diabetic retinopathy proceeds in stages, yet most automated systems grade fundus images with a single black-box network. Three gaps remain: (i) lesions differ widely in size and contrast, but segmenters typically apply the same blocks to all; (ii) ungradable images are usually excluded or treated as an extra class, and lesion-aware graders seldom test whether lesions drive the grade; (iii) staged systems often report each stage only on the images reaching it, leaving propagated errors unmeasured. HierarchiRetina, a screening, segmentation and grading cascade with inspectable stage outputs, addresses each gap. First, HSMoE-AUNet is a U-Net whose skip, bottleneck and decoder blocks are sparse mixtures of heterogeneous experts, with lesion-matched types, counts and losses; SwinHRUNetPP, a dual-encoder vessel segmenter, uses a field-of-view-restricted loss. Second, LG-DRG separates gradability from ordinal severity and lets lesion masks query the image through gated cross-attention. Third, an end-to-end evaluation counts screening misses as errors and traces each error to its stage. Pooled Dice ranged from 0.184 (microaneurysms) to 0.579 (exudates); vessel Dice was 0.731. On 58,689 held-out images from six datasets, end-to-end quadratic weighted kappa was 0.804, with referral sensitivity 0.832 at specificity 0.947, and the screening gate caused 66% of errors. In ablations, the grade ignored the masks, even with the cross-attention gate started open. On all 4,105 official DDR test images, six-class accuracy was 85.6%, above the best published six-class result we found (83.8%). Staged screening systems should be evaluated end-to-end, with stage attribution and mask ablation, before clinical deployment.

0.45

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

cs.CV cs.AI ·2026-09-27 ·David Restrepo, Chenwei Wu, Luis Filipe Nakayama, Miguel L. Martins, Stergios Christodoulidis +2 more
top venuebenchmarkdatasetcode/data similarity 0.58
Abstract · Accepted at NeurIPS 2026, Evaluations & Datasets Track. Interactive benchmark dashboard: https://huggingface.co/spaces/dsrestrepo/FOCUS-Reti…

Progress in AI-based retinal image analysis has accelerated with the adoption of foundation models, yet evaluating their real-world reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark evaluating retinal fundus models across vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted via LoRA fine-tuning. Results show no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual-encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards.

0.52

A Decision-Aware Evaluation Protocol for Uncertainty in Medical Image Segmentation

cs.CV ·2026-10-15 ·Saket Maganti, Shreyank N Gowda
similarity 0.58
Abstract

Medical segmentation uncertainty is often evaluated with calibration error or pixel-level error-detection scores, but these metrics do not show whether uncertainty improves downstream review decisions. We propose a decision-aware evaluation protocol that separates uncertainty estimation from deferral policy and evaluates their combination under fixed review budgets: which pixels, regions, or images should be accepted, and which should be reviewed. The protocol reports fixed-budget error reduction, risk-coverage behaviour, region-level review proxies, structural failure modes, probability-derived baselines, and sensitivity to review assumptions. We instantiate it across retinal vessel, skin lesion, and polyp segmentation with multiple backbones and uncertainty estimators. Under matched inference budgets and canonical multi-layer MC Dropout, test-time augmentation (TTA) gives a stronger error-detection signal across matched MC--TTA comparisons, including architecture and dropout-placement checks. However, estimator rankings are not universal. For example, probability-derived scores remain competitive, deep ensembles can outperform TTA, learned deferral helps mainly when the base estimator is weak, and rankings can change with review unit, uncertainty target, correction assumptions, and cost model. Structural and second-observer analyses further show that boundary and thin-structure failures are partly tied to annotation ambiguity. These findings support evaluating uncertainty as an estimator-policy-review configuration, not as a standalone score map. Code: https://anonymous.4open.science/r/Uncertainity-in-Medical-Image-Segmentation/README.md

0.34