Optimal Energy and LLM Task Scheduling for Multiple Cloud Data Centers

Zhongqi Zhao, Lei Fan, Zhu Han

eess.SY ·submitted 2026-11-17 05:44 UTC · v1

Abstract

This paper studies coordinated Large Language Model (LLM) training-task scheduling and facility operation for geographically distributed cloud data centers (CDCs). The central question is how two scheduling flexibilities - cross-CDC task transfer and task reordering - affect service and economic outcomes when remote execution remains subject to compute, bandwidth, energy, and zone-temperature constraints. We formulate a mixed-integer optimization model that jointly determines task outcomes, heterogeneous-node assignment, execution timing, pre-execution data transfer, node activation, and facility operation. A deterministic 24-hour case study contains 3 CDCs, 15 heterogeneous graphics processing unit (GPU) nodes, 4 thermal zones per CDC, and 103 tasks. In this instance, enabling transfer increases net profit by 57.9% relative to the otherwise matched no-transfer variant and increases completed tasks from 76 to 103. The more restrictive no-transfer FIFO-prefix variant completes 14 tasks and yields negative profit. The proposed schedule transfers 39 tasks, achieves 70.3% node utilization, and maintains zone temperatures within 24°C-27°C. These fixed-instance results indicate that cross-CDC transfer and task-reordering flexibility can improve the modeled profit and task-completion outcomes under the studied conditions.

Closest papers

Nearest neighbours by meaning across the whole index.

Job Class Thermal Intent Aware Liquid Cooling Allocation for AI Data Centers

cs.DC cs.PFeess.SY ·2026-09-25 ·Krishna Chaitanya Sunkara
similarity 0.66
Abstract · 6 pages, 5 figures, IEEE conference paper, first submitted to IEEE ICCSP 2026 02/02/2026

GPU-dense AI data centers need to run on liquid cooling as air simply cannot shed the heat at these power densities. Yet the cooling loops themselves are blind to what workloads are about to run; they crank up flow only after a sensor catches a temperature climb, which can take 30 to 50 seconds. We built Job-Class Thermal Intent (JCTI) to close that window. The scheduler already knows a job is coming and what class it belongs to; JCTI feeds that information straight to the cooling controller so it can stage coolant before the heat shows up. We pulled the thermal signatures for each job class out of MLPerf GPU power traces and tuned arrival patterns against Alibaba cluster data. Over 120 paired Monte Carlo trials the numbers come out to 56.4% fewer thermal violations and 60.2% less cumulative overshoot than a straight PI loop. As AI data centers evolving towards gigawatt grid loads with highly fluctuating power swings, thermally-aware scheduling reduces sudden demand and improves load prediction in grid side. Cooling and scheduling have been running as two separate systems for years despite each one knowing something the other needs, JCTI wires them together.

0.22

ETCInfer: An Energy-efficient Thermal-aware Cooling-joint Scheduler for LLM Inference in AI Datacenters

cs.DC cs.PFeess.SY ·2026-09-14 ·Rui Lu, Rui Ge, Huanghuang Liang, Xiaobo Zhou, Dan Wang
similarity 0.64
Abstract · 16 pages

Large language model (LLM) inference in AI datacenters creates a coupled control problem between GPU serving and facility cooling. Raising ambient temperature setpoints can reduce cooling energy and carbon, but also shrinks thermal headroom, induces GPU throttling, and leads to Service-Level-Objective (SLO) violations. In this paper, we study joint cooling--computing control for LLM inference: minimizing per-job GPU-plus-cooling energy while satisfying thermal safety and latency SLO constraints. We present ETCInfer, an energy-efficient, thermal-aware scheduler that selects a pre-job Computer Room Air Conditioner (CRAC) setpoint and adapts per-GPU frequency and micro-batch size during execution. ETCInfer builds compact physics-informed control models by calibrating GPU heat generation, chassis heat dissipation, CRAC power, and prefill/decode latency relations from telemetry. These models estimate hidden thermal states and time-to-throttle, enabling the scheduler to evaluate energy, temperature, and latency before applying an action. We formulate this joint setpoint--frequency--micro-batch control problem as a partially observable Markov decision process and design ETCAdapter, a learning-based controller that minimizes per-job energy under thermal safety and SLO constraints. We implement ETCInfer as a coordination layer over typical inference and cluster management stacks. Evaluation across real-trace simulation and validation experiments shows that ETCInfer reduces total job energy by up to 33.1%, thermal throttle exposure by up to 92.9%, and keeps SLO violation rates below 0.7% even at ambient temperatures up to $48^{\circ}\mathrm{C}$.

0.17

Quantifying the hosting capacity value of workload flexibility for AI data centers: A two-stage electricity-computation co-optimization framework

eess.SY ·2026-11-18 ·Jiakai Wu, Wei Sun, Pengyu Ren, Yifan Wang
hot direction similarity 0.64
Abstract

Grid connection constraints increasingly limit the expansion of AI data centers, yet the additional hosting capacity enabled by computational workload flexibility remains insufficiently quantified. This paper develops a two-stage electricity--computation co-optimization framework to quantify the individual and coordinated hosting capacity values of spatial and temporal workload flexibility. Data center capacities are determined endogenously, with computational task arrivals scaling with admitted capacity. Spatial routing of eligible interactive requests and temporal deferral of batch workloads are linked to server operation and facility power demand, subject to workload completion requirements and transmission constraints. The first stage maximizes aggregate hosting capacity; the second fixes the resulting site capacities and optimizes annual workload scheduling and generation dispatch to minimize generation and carbon costs. An 8760-hour case study with three data centers on a modified IEEE 118-bus system shows that temporal and spatial flexibility individually increase hosting capacity by 21.26\% and 5.37\%, respectively. Their coordinated use raises hosting capacity from 4635.1~MW to 6231.5~MW, a 34.44\% increase without network reinforcement. The coordinated gain exceeds the sum of the individual gains by 361.9~MW, demonstrating complementarity between spatial migration and temporal deferral. By redistributing computational demand across locations and operating hours, these mechanisms enable fuller utilization of existing transmission capacity. The findings establish workload flexibility as a quantifiable planning resource for accommodating additional data center capacity within existing transmission networks.

0.28

Next-generation O-RAN Edge: Energy-aware Joint Placement and Migration of Cloud-Native Functions

cs.IT cs.DCcs.ETcs.PF+1 ·2026-08-25 ·Nguyen Phuc Tran, Brigitte Jaumard, Oscar Delgado
similarity 0.63
Abstract · Submitted and under review

The transition toward Open Radio Access Networks (O-RANs) is reshaping how cellular infrastructure is deployed, managed, and optimized. This paper investigates the energy-aware joint placement and migration of cloud-native functions (CNFs) in an O-RAN edge cloud. We consider both a Single-CU-UP association model and a slice-aware Multi-CU-UP relaxation, in which distinct slice-flow groups of the same distributed unit (DU) may be assigned to different Centralized Unit User Plane (CU-UP) processing targets under one Centralized Unit Control Plane (CU-CP). For brevity, these scenarios are referred to as Single-CU and Multi-CU, respectively; Multi-CU never denotes multiple CU-CP associations. We formulate the problem as a Mixed-Integer Linear Program (MILP) that minimizes server, transmission, wake-up, and migration energy while satisfying server-resource capacities and one-way delay requirements over the F1 user-plane interface (F1-U) between each DU and its selected CU-UP in a fat-tree edge data center. To improve computational scalability, we also develop a deterministic k-means-based heuristic that approximates the MILP decisions without requiring repeated exact optimization. Over the evaluated 24-hour workload, the theoretical Multi-CU relaxation reduces modeled energy consumption by 5.7% relative to the Single-CU baseline. For the Multi-CU case, the proposed heuristic remains within approximately 9.7% of the proposed MILP, demonstrating a favorable trade-off between energy efficiency and computational tractability.

0.28

Solver-Free and Cost-Aware Online Scheduling of AI Data Center Tasks

eess.SY cs.AI ·2026-11-17 ·Xin Qin, Dawei Qiu, Fei Teng
benchmark similarity 0.63
Abstract

AI data centers receive computing tasks continuously, whereas solver-based optimization takes time to run and electricity is priced per settlement period. This paper bridges this timing gap through a solver-free online optimization rule inspired by dual decomposition. The rule assigns each task a start period upon arrival to optimize energy cost subject to operational constraints, shifting flexible tasks toward low-price periods while keeping high-priority tasks on schedule. Simulations on the A100 GPU trace (3,456 GPUs, 1,343 tasks) show that the proposed rule keeps GPU and CPU use within capacity while scheduling tasks at low cost. Compared with a multi-timescale optimization benchmark, it achieves a lower cost and, because it needs no solver, much less computation time.

0.27

Grid Demand Flexibility Assessment of AI Data Centers via Batch Workload Temporal Shifting

eess.SY ·2026-09-29 ·Suntao Su, Liang Du, Shengyi Wang
similarity 0.63
Abstract · 5 pages, 5 figures, conference

The rapid growth of artificial intelligence (AI) data centers has introduced new challenges to power system operation. As their power demand becomes larger and more variable, quantitatively characterizing their demand flexibility is increasingly important for effective power system coordination. However, heterogeneous workload characteristics and resource requirements make this flexibility difficult to characterize directly. This paper proposes a framework for assessing the grid-compatible demand flexibility of AI data centers via batch workload temporal shifting. An averaging-based resource usage processing method is developed to map fine-resolution CPU, GPU and memory usage into unified time intervals compatible with power system operation. A workload temporal scheduling model is then formulated to shift batch workloads while preserving execution continuity, delay constraints, and server resource capacities, and is coupled with a utilization-dependent server power model to translate workload scheduling decisions into server power demand. Two complementary flexibility metrics are evaluated: short-term peak demand shaving and the maximum duration of sustained power reduction. Numerical results based on real GPU cluster traces demonstrate that workload temporal shifting can provide quantifiable and grid-compatible demand flexibility for AI data centers with limited disruption to computing workloads.

0.13

Adaptive Context Parallelism for Production LLM Serving

cs.OS ·2026-09-04 ·Jiarui Guo, Rongle Wang, Peijun Huang, Zongwei Lv, Ziqing Wang +5 more
similarity 0.62
Abstract

As LLM context windows expand and input sequences grow longer, serving systems face increasing computational and memory demands. Context parallelism (CP), which partitions the input sequence across multiple ranks to parallelize the computation, has therefore become increasingly important for efficient LLM serving. However, existing CP-enabled systems either rely on static CP configurations or adjust the CP degree only for active requests or batches. In this paper, we present Vertumnus, an adaptive CP serving system designed for heterogeneous and evolving workloads. At the request level, Vertumnus routes requests among workers with different CP degrees using a placement cost that combines predicted queuing delay, cache-aware prefill time, and GPU-time cost. At the cluster level, Vertumnus adapts the worker composition through seconds-scale split and merge operations as workload demand changes. Vertumnus further introduces a global prefix-cache management policy that coordinates cache placement and replication among workers with the same or different CP degrees, preserving cache locality as request assignments and worker composition change. Experiments on a 64-GPU cluster with public and production workloads show that, under the highest evaluated loads, Vertumnus reduces mean TTFT by up to 28.1% and improves token-weighted SLO attainment by up to 13.3 percentage points over the strongest baseline.

0.43

From Overloaded to Guaranteed: High-Throughput Multi-SLO Enforcement for LoRA-Assisted On-Premise LLM Deployment

cs.CL cs.DC ·2026-10-04 ·Zeshen Zhang, Han Zhao, Weihao Cui, Quan Chen, Yu Liu +7 more
similarity 0.62
Abstract · 22 pages, 16 figures, 4 tables

As Large Language Models (LLMs) become essential in privacy-sensitive sectors like hospitals and government agencies, the on-premise LLM servers offer a cost-effective and secure alternative to public cloud services. However, these resource-constrained servers struggle to guarantee heterogeneous Service Level Objectives (SLOs) when serving multiple LoRA-adapted services simultaneously. Existing serving frameworks suffer from severe SLO violations due to the computational overhead of LoRA layers and the rigid nature of batch scheduling. To address this, we propose HALO, a scheduling method tailored for LoRA-assisted on-premise LLM deployment. HALO introduces two key innovations: a spatial multiplexing strategy that overlaps Base and LoRA computations by partitioning GPU Streaming Multiprocessors (SMs), and an SLO-aware scheduler that decouples request execution based on "request-level slack." By prioritizing urgent tasks and utilizing idle budget for traffic shaping, HALO significantly mitigates resource contention. Our evaluation demonstrates that HALO minimizes SLO violations while improving throughput compared to state-of-the-art baselines.

0.14