ACUS: An Angular Calibrated Uncertainty Score for Incomplete-View CT

Zihan Deng, Chuanzhi Xu, Quankeng Huang, Yujie Liu, Zhenzhen Gong, Junjie Huang, Tianye Niu, Lequan Yu

cs.CV ·submitted 2026-11-18 03:06 UTC · v1

Abstract

Sparse-view and limited-arc computed tomography (CT) are commonly treated as projection completion: a network fills an unmeasured view, and the result is ranked by similarity to one ground-truth image. That score can be high even when the query angle is far from every acquired measurement, because a learned prior may invent anatomy the scan never constrained. Existing protocols therefore leave a basic question unanswered: how does predictive reliability change with distance from the acquired views? We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question. ACUS is the Winkler interval score of a nominal 90% predictive interval on held-out projections, binned by distance to the nearest acquired view. It charges interval width and adds a large miss penalty when a held-out pixel falls outside the interval, so a narrow band helps only when coverage holds. We use collapse on acquired angles as a necessary consistency check on the predictor. On chest and dental cone-beam orbits, interval width grows with the angular gap. Empirical coverage ranges from 77% to 92%, and the peak signal-to-noise ratio (PSNR) of the point estimate falls as the width rises. Nearest-neighbor, interpolation, and point completion, each given one residual scale, have zero reported far coverage and incur outside-distance penalties. ACUS exposes gap-dependent overconfidence that a point-estimate PSNR alone does not measure.

Closest papers

Nearest neighbours by meaning across the whole index.

View optimization in Computed Tomography

eess.IV ·2026-11-02 ·Seemeen Karimi, Christopher McGuire
published similarity 0.64
Abstract · All figures are in the PDF. presented at a conference, conference proceedings pending

Many emerging CT imaging applications must operate with data from sparse projection angles, on the order of 10 views, such as first responder scenarios, dynamic imaging of detonation events, and flash imaging of materials under extreme conditions in high energy-density science. Few-view imaging is a data undersampling problem, that degrades tomographic reconstructions with streaks, shadows, and other aliasing artifacts, due to ill-conditioning. In few- view CT, the specific set of projection angles can strongly impact reconstruction quality, and the optimal angles depend on the object being scanned. Despite a surge of recent research, there is much to explore in this problem. We present an object-aware performance prediction framework for few-view projection datasets based on a matrix decomposition of the discretized forward model augmented with expected object gradient information. The method yields a quantitative score for a candidate set of view angles that can underpin a view selection recommendation algorithm. A key feature is that it can be applied at multiple stages of acquisition: a priori, before any radiographs are taken, or adaptively, after some radiographs are collected, to determine the next best view. We demonstrate the approach using simulated CT data with 5 view and 15 view configurations. Preliminary results are encouraging; images reconstructed using a standard statistical algorithm show that reconstruction accuracy agrees with our performance score. Reconstruction accuracy was evaluated against a known ground truth using an information theoretic score. Continued testing with complex objects and multiple geometries is necessary.

0.14

SpatialUQ: Post-Hoc Uncertainty Quantification from Spatial Consistency in Black-Box Vision Models

cs.CV cs.AIcs.LG ·2026-10-07 ·Md Kawsher Mahbub, Milon Biswas, Mirza Niaz Morshed, Wei Yu
code/data similarity 0.63
Abstract

Clinical vision models are often deployed as frozen black boxes with no access to internals, retraining, or ground truth at inference time. We introduce \textbf{SpatialUQ}, a post-hoc uncertainty method using only output probabilities. It measures the Jensen-Shannon divergence between the global prediction and the mean of five fixed spatial crops in six deterministic forward passes. The premise is simple, trustworthy predictions are spatially consistent. On NIH ChestX-ray14 (DenseNet-121, $N{=}25{,}596$), our Multicrop Uncertainty Score (MUS) reaches $0.784$ failure-detection AUC versus $0.664$ for MC-Dropout ($p{<}10^{-6}$) at one-fifth the compute, with native calibration ($\text{SCE}{=}0.049$ vs.\ $0.127$ for $\ell_1$), the best-calibrated among methods above 0.78 AUC. A supervised fusion of MUS with entropy, confidence, and $\ell_1$ reaches $0.832$, outperforming a five-member ensemble ($0.813$). MUS scales with model quality, reaching $0.899$ with BiomedCLIP ($ρ= 0.846$), while this relationship remains meaningful in-distribution ($ρ= 0.523$) but breaks down under severe distribution shift (VinBigData, $ρ= 0.027$). MUS is well-suited to diffuse findings but is less dependable for small focal lesions such as nodules. Code and experimental materials are publicly available at https://huggingface.co/datasets/kawsher11/SpatialUQ.

0.34

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.62
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

eess.IV cs.CV ·2026-11-03 ·Bowen Xiang, Michael I. Miga
similarity 0.60
Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

0.25

Predicting silent failures of learned inference under restricted access: what measurement physics and prior information explain

cs.LG stat.ML ·2026-10-20 ·Mario Gianni
similarity 0.59
Abstract · 22 pages, 5 figures. Code and data: https://doi.org/10.5281/zenodo.23392686

Learned priors are used to reconstruct regions that measurements barely reach, and to report uncertainty there. They can fail silently: the reported interval excludes the truth while every ground-truth-free diagnostic stays within its noise. We call such errors the blind set and ask whether they can be predicted before the target data are seen. For a correctly specified linear-Gaussian model averaged over the prior, the risk of a silent failure factorises exactly into non-detection and non-coverage, which does not hold for learned systems in general; we build a score that approximates this reference by linearising a VAE prior. In a prospective study on real X-ray CT objects (2DeteCT) under simulated restricted access, with predictions committed by hash before any trial, the score ranked the realised blindness of two learned inference systems (latent Laplace and ensemble Kalman inversion) with Spearman $ρ= 0.79$ and 0.84 over 240 pre-specified errors. Simple structural predictors would also have passed these tests. Sequential post-hoc analyses, each specified before its own computation, show that under bounded reach the learned score gave no detectable improvement over a physics-based baseline, in rankings or trial-level log scores. At the weakest attenuation studied, prior information improved rankings over the physics-based baseline, most clearly for ensemble Kalman inversion, but a Gaussian prior did as well and the gain was not detectable at the trial level. The score is not a calibrated probability. Silent failures can be anticipated here, but their structure follows mainly from measurement access and the decision quantity rather than from the learned prior.

0.35

Uncertainty of Vision Medical Foundation Models

cs.LG ·2026-08-31 ·Haoxu Huang, Narges Razavian
similarity 0.59
Abstract

Accurate uncertainty estimation is essential for machine learning systems de- ployed in high-stakes domains such as medicine. Traditional approaches primarily rely on probability outputs from trained models (point predictions), which provide no formal guarantees on prediction coverage and often require additional calibra- tion techniques to improve reliability. In contrast, conformal prediction (region prediction) offers a principled alternative by generating prediction sets with finite- sample validity guarantees, ensuring that the ground truth is contained within the set at a specified confidence level. In this study, we explore the impact of pre-training approach, dataset scale and domain on both point and region-level uncertainty quantification, by studying domain-specific vision medical foundation models vs. general domain vision foundation models. We conduct a comprehensive evaluation across foundation models trained on retinal, histopathological, and Chest X-Rays data, applying various calibration techniques. Our results demonstrate that (1) pre-training on higher-quality domain-specific datasets along with self-supervised learning leads to better-calibrated point predictions than general domain pre-training, (2) stan- dard re-calibration methods alone cannot fully mitigate uncertainty discrepancies across models trained on different data sources, (3) domain-specific foundation model can lead to more efficient conformal prediction. These findings highlight the importance of careful model selection and the inte- gration of both point and region prediction to enhance the reliability and trust- worthiness of medical AI systems. Our work underscores the need for a holistic approach to uncertainty quantification in recent development of medical vision foundation model, ensuring robust and interpretable AI-driven decision-making.

0.06

SPARCL: Spatially Adaptive Regional Coverage for Active Learning in Chest X-ray Analysis

cs.CV cs.LG ·2026-10-13 ·Juho Jung, Seongjae Kang, Mijoo Kim, Sungduk Cho, Yunkyoung Jun +2 more
similarity 0.58
Abstract · 10 pages, 7 figures

Pixel-level annotation for chest X-ray (CXR) lesion segmentation is expensive, making active learning (AL) essential. However, existing AL strategies fail to account for the spatial distribution of selected samples, resulting in inconsistent performance across focal (e.g., aortic calcification) and diffuse (e.g., nodules) pathologies. In this paper, we propose SPARCL (Spatially Adaptive Regional Coverage for Active Learning) to dynamically balance predictive uncertainty with cumulative spatial coverage. By employing a concave coverage function, SPARCL imposes diminishing returns on previously annotated regions, naturally directing the annotation budget toward under-labeled areas. Furthermore, an entropy gate reverts the algorithm to standard uncertainty sampling when spatial variation is absent. This coverage objective is monotone submodular, guaranteeing near-optimal greedy batch selection. To address how aggregate metrics like Dice obscure regional failures, we further introduce two metrics---Spatial Inconsistency (SI) and Performance Coverage (PC)---to quantify anatomical fairness across AL rounds. Evaluated on an in-house calcification cohort and public CXR benchmarks, SPARCL reaches 95% of fully supervised performance using only 24% of the data, compared to 29% for the best baseline. Ultimately, SPARCL ensures robust spatial reliability, surfacing regional gains that aggregate metrics miss.

0.25

ReVar3R: Gauge-Aware Perturbation Uncertainty for Feed-Forward 3D Reconstruction

cs.CV ·2026-10-06 ·Sammam Mahdi, Fariha Binta Salim, Rakin Bin Rabbani, Aniqua Nusrat Zereen
highly cited similarity 0.58
Abstract

A correctly reconstructed distant point appears uncertain even when a frozen 3D model processes equivalent inputs because its output frame rotates fractionally. This exposes a weakness of trainingfree perturbation uncertainty: when outputs contain an unobserved symmetry, run-to-run variation potentially reflects symmetry rather than error. Existing alternatives have trade-offs: built-in confidence is outperformed in most evaluated conditions, while trained evidential heads require modelspecific supervision. For point maps, this research derives a closed-form, error-independent variance term that grows with scene extent and potentially overwhelms the desired signal. Simulation reproduces the effect; all 30 real VGGT view-sets tested exhibit its predicted $\|x_p\|^2$ signature. ReVar3R robustly registers predictions to a common similarity frame before computing per-point variance, without retraining or modifying the frozen model. Optional calibration and fusion use a held-out split. Across VGGT, π3, and MASt3R on six datasets, the same estimator on every backbone lowers AUSE below built-in confidence in 15 of 18 conditions. The staged evaluation yields 11 of 18 wins for the label-free core, 12/18 for label-free equal-weight fusion, 14/18 with held-out weights, and 15/18 when the built-in signal is included. Against a trained evidential head, the result is a trade-off: the head calibrates magnitude better and leads in its training domain, whereas ReVar3R transfers across backbones without adaptation. Its ranking improves point filtering, but it does not detect stable systematic bias, aid novel-view synthesis, or transfer calibration across domains.

0.45