When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

Bowen Xiang, Michael I. Miga

eess.IV cs.CV ·submitted 2026-11-03 21:02 UTC · v1

Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

Closest papers

Nearest neighbours by meaning across the whole index.

ACUS: An Angular Calibrated Uncertainty Score for Incomplete-View CT

cs.CV ·2026-11-18 ·Zihan Deng, Chuanzhi Xu, Quankeng Huang, Yujie Liu, Zhenzhen Gong +3 more
similarity 0.60
Abstract

Sparse-view and limited-arc computed tomography (CT) are commonly treated as projection completion: a network fills an unmeasured view, and the result is ranked by similarity to one ground-truth image. That score can be high even when the query angle is far from every acquired measurement, because a learned prior may invent anatomy the scan never constrained. Existing protocols therefore leave a basic question unanswered: how does predictive reliability change with distance from the acquired views? We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question. ACUS is the Winkler interval score of a nominal 90% predictive interval on held-out projections, binned by distance to the nearest acquired view. It charges interval width and adds a large miss penalty when a held-out pixel falls outside the interval, so a narrow band helps only when coverage holds. We use collapse on acquired angles as a necessary consistency check on the predictor. On chest and dental cone-beam orbits, interval width grows with the angular gap. Empirical coverage ranges from 77% to 92%, and the peak signal-to-noise ratio (PSNR) of the point estimate falls as the width rises. Nearest-neighbor, interpolation, and point completion, each given one residual scale, have zero reported far coverage and incur outside-distance penalties. ACUS exposes gap-dependent overconfidence that a point-estimate PSNR alone does not measure.

0.29

Beyond Uncertainty: Generalizable Failure Monitoring for Surgical Segmentation under Acquisition Degradation

cs.CV ·2026-08-17 ·Hieu D. Pham, Dang P. M. Cao, Thanh Trung Huynh
published similarity 0.60
Abstract · Accepted at MICCAI'2026 @UNSURE Workshop

Surgical segmentation networks can fail silently under acquisition degradation: predicted masks may be wrong even when model confidence remains high. Existing deployment-time monitors rely primarily on uncertainty estimates and can therefore miss confident failures. We present TCSR-Monitor (Temporal Conformal Surgical Risk Monitor), a post-hoc failure-monitoring framework that combines confidence with observable shape, temporal-consistency, and image-quality cues. TCSR-Monitor wraps a frozen segmentation model, requires no model internals, and operates without ground truth at deployment. We also introduce a validation protocol to assess whether alarms remain credible under distribution shift. On EndoVis 2017, leave-one-corruption-out evaluation shows that TCSR-Monitor generalizes to unseen acquisition degradations and substantially outperforms confidence-based baselines. A circularity control confirms that it predicts segmentation failure rather than simply detecting corrupted images. Mondrian conformal calibration balances miss-rates across degradation severities, but a single global threshold still produces false alarms on up to 40% of correctly segmented frames at moderate corruption. Zero-shot transfer to SAM2 demonstrates feature portability, although entropy outperforms the transferred monitor at both evaluated thresholds. Overall, reliable monitoring under acquisition degradation benefits from complementary observable signals beyond confidence alone, but substantial false-alarm and transfer limitations remain.

0.34

Trust the Ray, Not the Depth: Ray-Lateral Agreement for Multi-View 3D Human Pose Fusion

cs.CV ·2026-11-17 ·Farnoosh Koleini, Ahmed Helmy, Pu Wang, Xiwu Cao
benchmarkhot direction similarity 0.57
Abstract · 10 pages, 5 figures, 1 table

Put a monocular mesh estimator behind every camera of a calibrated rig, and the reconstructed bodies land a meter or more apart. The cause is geometric: each estimate sits at the depth implied by a focal length the network assumed, not the one the camera has. Its error therefore points almost entirely along its own viewing ray, and the calibration tells us that direction exactly. To address this, we introduce the Ray-Lateral Agreement (RLA), which follows one rule: trust the ray, not the depth. RLA first slides every estimate along its own rays, which removes the depth bias and leaves the shape untouched. It then fuses the views one point at a time, under a Gaussian error whose precision follows each viewing ray. The maximum-likelihood solution is closed-form, interpolates between averaging and midpoint triangulation, and stays well conditioned where triangulation is singular. Robustness is the harder half, because correct views also disagree along their rays. Any weight built on the full residual therefore punishes good views together with bad ones. Ray-lateral agreement instead scores every view, at every point, by its residual across that view's own ray alone. We evaluated RLA on multi-camera public benchmark datasets. Across two, three, and four cameras and three per-view pose estimators, RLA consistently achieves lower worst-case error than all triangulation baselines.

0.37

A digital-twin framework for forecasting treatment-day imaging with contour uncertainty in adaptive proton radiotherapy

cs.AI physics.med-ph ·2026-09-21 ·Yizhou Wu, Jie Ding, Justin Roper, Minglei Kang, Yuheng Li +4 more
similarity 0.56
Abstract

Head-and-neck anatomy changes over a six-to-seven-week proton course, and the anatomy of a later week cannot be imaged when the plan is made. We present a digital-twin framework that forecasts a patient's treatment-day anatomy as an ensemble of predicted CTs with propagated contours and quantifies the uncertainty of the forecast contours. The twin is a library of previously treated patients with planning and weekly quality-assurance CTs (QACTs), made patient-specific by a two-step foundation-model deformable registration: a cross-patient field carries each library patient onto the current patient, and a longitudinal field, estimated in the current patient's frame, carries that patient's planning-to-QACT change onto the current patient's own planning CT. A library of 302 observations from 88 patients yields about 300 replicates per patient, each a deformation that occurred in a treated patient. The dispersion of the propagated contours, resolved by outward normal, is six-direction contour uncertainty in millimeters. This is uncertainty in the input to the forecast, which library patient the current patient follows, rather than in model parameters, and it is unchanged when the registration engine is exchanged. On ten patients with clinician contours on two QACTs, the library alone fixes the anisotropic shape of the uncertainty (4.5 to 6.2 mm); the first QACT narrows it by a factor of 3.2 to 3.6 without a contour being drawn; an approved contour improves the center but not the width. The estimate orders directions correctly but is not Gaussian-calibrated. A clinical target volume expansion is worked out as one application.

0.44

ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration

cs.RO ·2026-10-07 ·Tiancheng Li, Yingyu Wang, Peter Walker, Liang Zhao, Shoudong Huang
similarity 0.55
Abstract · Preprint

Accurate bone registration is essential for orthopedic surgical navigation and robotic assistance. In a common workflow, the surgeon needs to identify and probe a number of prescribed locations on the exposed bone surface to obtain data points for registration, which can be difficult and time-consuming under limited surgical exposure. Reducing the number of required points while providing clear probing guidance would ease the surgeon's acquisition task intra-operatively. We present ActiveReg, a closed-loop framework that recommends probing regions rather than individual points, allowing flexibility in the exact contact location. A D-optimal planner that takes into account the already acquired points and the uncertainty of current registration information helps achieve accurate registration with fewer points. An online assessment combines pre-update innovation consistency with uncertainty at predefined surgical task locations improves the reliability of completion decision, without requiring ground truth. Simulations across four anatomical scenarios demonstrated that ActiveReg can achieve competitive accuracy compared with baseline registration methods while using substantially fewer acquired points. Real phantom experiments with optical and electromagnetic tracking demonstrated comparable mean target registration error to the Gradient-SDF framework, using only 24-28 acquired points instead of 771-1263.

0.25

Repeatability Characterisation and Error Budget of a Consumer Structured-Light Scanner for 3-D Wound Geometry:A Rigid-Phantom Study

cs.CV ·2026-08-31 ·Pushkal Kumar, Aadit Aggarwal, Karlen Aleksanyan
theoryunusual similarity 0.55
Abstract · 8 pages, 2 figures

We characterise the measurement error of a free- hand consumer structured-light scanner used to derive three- dimensional geometric wound descriptors. Rigid wound-care phantoms cannot change, so every difference between repeat scans of one site is measurement error; all repeats come from a single scanner unit, nine sites and 23 scans, so this charac- terises one instrument. The 95 percent repeatability limit for reconstructed surface area is a factor of 4.8, with a confidence interval from 3.0 to 7.0, so rescanning an unchanged site can shift the reading from a 79 percent decrease to a 377 percent increase. Forty-four of 45 descriptors fall below an intraclass correlation of 0.50, and none of 248 descriptor and pipeline combinations reaches 0.75. An error budget formed by holding the analy- sis region fixed, leaving sensor and reconstruction untouched, bounds the share of variance attributable to how much surface the operator captured at 75 percent for surface area, 91 percent for hull area and 95 percent for bounding-box diagonal; only hull volume is majority instrumental, at 48 percent, so a better sensor would buy little. No wound is delineated anywhere in the chain, so the comparison against the four-week area reduction used clinically to predict healing, a ratio near 2.1, is a lower bound on the noise an unsegmented pipeline must overcome, not a measurement of wound-area reproducibility. Standardising the analysis region cuts the limit to 2.13, meeting that ratio rather than clearing it. Statistical outlier removal imposes a measured systematic area deficit near 11 percent.

0.29

SpatialUQ: Post-Hoc Uncertainty Quantification from Spatial Consistency in Black-Box Vision Models

cs.CV cs.AIcs.LG ·2026-10-07 ·Md Kawsher Mahbub, Milon Biswas, Mirza Niaz Morshed, Wei Yu
code/data similarity 0.54
Abstract

Clinical vision models are often deployed as frozen black boxes with no access to internals, retraining, or ground truth at inference time. We introduce \textbf{SpatialUQ}, a post-hoc uncertainty method using only output probabilities. It measures the Jensen-Shannon divergence between the global prediction and the mean of five fixed spatial crops in six deterministic forward passes. The premise is simple, trustworthy predictions are spatially consistent. On NIH ChestX-ray14 (DenseNet-121, $N{=}25{,}596$), our Multicrop Uncertainty Score (MUS) reaches $0.784$ failure-detection AUC versus $0.664$ for MC-Dropout ($p{<}10^{-6}$) at one-fifth the compute, with native calibration ($\text{SCE}{=}0.049$ vs.\ $0.127$ for $\ell_1$), the best-calibrated among methods above 0.78 AUC. A supervised fusion of MUS with entropy, confidence, and $\ell_1$ reaches $0.832$, outperforming a five-member ensemble ($0.813$). MUS scales with model quality, reaching $0.899$ with BiomedCLIP ($ρ= 0.846$), while this relationship remains meaningful in-distribution ($ρ= 0.523$) but breaks down under severe distribution shift (VinBigData, $ρ= 0.027$). MUS is well-suited to diffuse findings but is less dependable for small focal lesions such as nodules. Code and experimental materials are publicly available at https://huggingface.co/datasets/kawsher11/SpatialUQ.

0.34

Uncertainty-Guided Handshake: Efficient Human-in-the-Loop Refinement for Surgical-Grade Glioma Segmentation

cs.CV ·2026-10-01 ·Samuel Hart, Ahmad Yahya, Ahmed Karam Eldaly
theory similarity 0.54
Abstract · 12 pages

While state-of-the-art automated models for medical image segmentation achieve high mean performance, they frequently suffer from localized, catastrophic failures that preclude safe clinical deployment, particularly in neuro-oncology. Interactive segmentation frameworks mitigate this by incorporating human oversight, but traditionally impose prohibitive cognitive and temporal workloads by requiring clinicians to manually search for errors. In this project, we present an efficient, Hybrid Structural-Aleatoric Human-in-the-Loop framework for glioma segmentation that bridges the gap between automated baseline performance and surgical-grade precision, achieving sub-2.0 mm HD95 on curated benchmarks while providing safety-net routing for structural failures across real-world clinical data. By extracting voxel-wise Test-Time Augmentation (TTA) uncertainty and applying hierarchical topological filtering, our method proactively isolates high-risk structural anomalies. We comprehensively evaluated our approach on a challenging out-of-distribution clinical stress-test cohort (N = 362). Operating under a simulated Human Oracle, the framework improved the Whole Tumor (WT) Dice score from 0.891 to 0.914 and reduced the 95th percentile Hausdorff Distance (HD95) from 5.82 mm to 4.76 mm. Critically for surgical safety, the system rescued severe boundary failures in the Tumor Core, reducing mean HD95 from 17.96 mm to 14.83 mm (improving absolute TC Dice to 0.356). These spatial rescues were achieved while demanding a median interactive workload of just 11.3% of the target volume. Acknowledging this as a simulated upper bound lacking real-world cognitive friction, the framework nevertheless demonstrates a highly Pareto-efficient pathway for safely deploying clinical AI.

0.15