Repeatability Characterisation and Error Budget of a Consumer Structured-Light Scanner for 3-D Wound Geometry:A Rigid-Phantom Study

Pushkal Kumar, Aadit Aggarwal, Karlen Aleksanyan

cs.CV ·submitted 2026-08-31 01:49 UTC · v1
theoryunusual

Abstract

We characterise the measurement error of a free- hand consumer structured-light scanner used to derive three- dimensional geometric wound descriptors. Rigid wound-care phantoms cannot change, so every difference between repeat scans of one site is measurement error; all repeats come from a single scanner unit, nine sites and 23 scans, so this charac- terises one instrument. The 95 percent repeatability limit for reconstructed surface area is a factor of 4.8, with a confidence interval from 3.0 to 7.0, so rescanning an unchanged site can shift the reading from a 79 percent decrease to a 377 percent increase. Forty-four of 45 descriptors fall below an intraclass correlation of 0.50, and none of 248 descriptor and pipeline combinations reaches 0.75. An error budget formed by holding the analy- sis region fixed, leaving sensor and reconstruction untouched, bounds the share of variance attributable to how much surface the operator captured at 75 percent for surface area, 91 percent for hull area and 95 percent for bounding-box diagonal; only hull volume is majority instrumental, at 48 percent, so a better sensor would buy little. No wound is delineated anywhere in the chain, so the comparison against the four-week area reduction used clinically to predict healing, a ratio near 2.1, is a lower bound on the noise an unsegmented pipeline must overcome, not a measurement of wound-area reproducibility. Standardising the analysis region cuts the limit to 2.13, meeting that ratio rather than clearing it. Statistical outlier removal imposes a measured systematic area deficit near 11 percent.

Comment
8 pages, 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

When can multi-fragment 2D/3D registration be trusted? Calibrated certification and uncertainty-driven view planning for pelvic fracture fluoroscopy

eess.IV cs.CV ·2026-11-03 ·Bowen Xiang, Michael I. Miga
similarity 0.55
Abstract

Registering a segmented CT to fluoroscopy can locate every fracture fragment but can guide surgery only when trusted. After each shot, our closed loop registers all fragments, bounds their errors with a calibrated sandwich covariance, flags implausible or ambiguous ones, and stops or plans the next view. On simulated fluoroscopy of 60 held-out fracture CTs with realistic image uncertainty, 95% bounds covered 83% of unflagged fragments and 91% of those within 5mm, but from the second view on 14% failed by over 5mm, a third with bounds of at most 2mm. A fragment's shift when a view was added separated tightly bounded failures best (exploratory; AUC 0.94, bound 0.81). Requiring that the newest view moved no fragment beyond its bound, preferred post hoc, lowered false stops at 2mm from 23% to 6% overall, with 345 instead of 362 correct ones but more trajectories uncertified; delaying the stop did not, and other signals at equal acceptance left 10-15% false. With a segmentation error shared by all views (median Dice 0.89), 21% of this rule's stops were false against 10% without it (15 cases; exploratory). Minimax planning certified sooner than the clinical protocol without the check (4.20 versus 4.72 shots, Holm p <0.001), but no criterion reached the pre-specified endpoint, a true 2mm error, significantly sooner, even in the true basin. On real fluoroscopy of five intact pelves no 2mm certificate was false. Trust takes evidence across views, not only a calibrated local bound.

0.25

ACUS: An Angular Calibrated Uncertainty Score for Incomplete-View CT

cs.CV ·2026-11-18 ·Zihan Deng, Chuanzhi Xu, Quankeng Huang, Yujie Liu, Zhenzhen Gong +3 more
similarity 0.53
Abstract

Sparse-view and limited-arc computed tomography (CT) are commonly treated as projection completion: a network fills an unmeasured view, and the result is ranked by similarity to one ground-truth image. That score can be high even when the query angle is far from every acquired measurement, because a learned prior may invent anatomy the scan never constrained. Existing protocols therefore leave a basic question unanswered: how does predictive reliability change with distance from the acquired views? We propose the Angular Calibrated Uncertainty Score (ACUS) to answer that question. ACUS is the Winkler interval score of a nominal 90% predictive interval on held-out projections, binned by distance to the nearest acquired view. It charges interval width and adds a large miss penalty when a held-out pixel falls outside the interval, so a narrow band helps only when coverage holds. We use collapse on acquired angles as a necessary consistency check on the predictor. On chest and dental cone-beam orbits, interval width grows with the angular gap. Empirical coverage ranges from 77% to 92%, and the peak signal-to-noise ratio (PSNR) of the point estimate falls as the width rises. Nearest-neighbor, interpolation, and point completion, each given one residual scale, have zero reported far coverage and incur outside-distance penalties. ACUS exposes gap-dependent overconfidence that a point-estimate PSNR alone does not measure.

0.29

SpatialUQ: Post-Hoc Uncertainty Quantification from Spatial Consistency in Black-Box Vision Models

cs.CV cs.AIcs.LG ·2026-10-07 ·Md Kawsher Mahbub, Milon Biswas, Mirza Niaz Morshed, Wei Yu
code/data similarity 0.52
Abstract

Clinical vision models are often deployed as frozen black boxes with no access to internals, retraining, or ground truth at inference time. We introduce \textbf{SpatialUQ}, a post-hoc uncertainty method using only output probabilities. It measures the Jensen-Shannon divergence between the global prediction and the mean of five fixed spatial crops in six deterministic forward passes. The premise is simple, trustworthy predictions are spatially consistent. On NIH ChestX-ray14 (DenseNet-121, $N{=}25{,}596$), our Multicrop Uncertainty Score (MUS) reaches $0.784$ failure-detection AUC versus $0.664$ for MC-Dropout ($p{<}10^{-6}$) at one-fifth the compute, with native calibration ($\text{SCE}{=}0.049$ vs.\ $0.127$ for $\ell_1$), the best-calibrated among methods above 0.78 AUC. A supervised fusion of MUS with entropy, confidence, and $\ell_1$ reaches $0.832$, outperforming a five-member ensemble ($0.813$). MUS scales with model quality, reaching $0.899$ with BiomedCLIP ($ρ= 0.846$), while this relationship remains meaningful in-distribution ($ρ= 0.523$) but breaks down under severe distribution shift (VinBigData, $ρ= 0.027$). MUS is well-suited to diffuse findings but is less dependable for small focal lesions such as nodules. Code and experimental materials are publicly available at https://huggingface.co/datasets/kawsher11/SpatialUQ.

0.34

Surface Reconstruction from Range Scans Under Visibility Constraints

cs.CV ·2026-10-13 ·Gabriel Lenain, Edmond Boyer, Jean Ponce
similarity 0.51
Abstract

Surface reconstruction from range scans is challenging in the presence of noise and outliers, as fidelity to observations must be balanced against sensitivity to measurement errors. Yet, most neural approaches discard the sensor positions and corresponding visibility information, compensating for this loss with geometric priors or regularization terms. We instead formulate surface reconstruction as robust regression of the predicted first surface intersection along each acquisition ray against its measured depth, which penalizes predicted surface intersections within the segment between the sensor and the observed point. We represent the surface as the zero set of a 1-Lipschitz multi-layer perceptron, allowing the use of linearly convergent sphere tracing to compute the first hit, and use a robust Huber loss for regression. Our formulation requires neither oriented normals, sampled off-surface points, nor an eikonal loss. Comparisons with the state of the art on synthetic and real data with varying levels of noise and outlier contamination demonstrate competitive performance on clean data and much improved fidelity and robustness under even moderate corruption. Our analysis further confirms a trade-off between fidelity and robustness: greater fitting capacity improves data fidelity in the clean case but increases sensitivity to the measurement errors inherent in real acquisitions, with a sweet spot typically emerging at intermediate capacity.

0.37

How reliable is an embedding of the seabed? Repeat-look measurement of frozen encoders on synthetic aperture sonar

cs.CV cs.LGstat.AP ·2026-11-07 ·Harold Horsley, Oscar Pizarro, Hayat Rajani, Morten Omholt Alver
publishedposition similarity 0.51
Abstract · Accepted at the Maritime Computer Vision Workshop (MaCVi) at WACV 2027

Pretrained encoders from self-supervised representation learning are increasingly applied to sonar imagery of the seafloor, where they are evaluated with protocols that take one embedding per target. A target patch of seabed, by contrast, is re-imaged from an alternate look on overlapping survey passes, so each embedding is one measurement of that target. Standard protocols cannot say how consistent those measurements are, or how much of their spread belongs to the patch and how much to the acquisition geometry. We treat this as a measurement-reliability problem. Using a synthetic-aperture sonar (SAS) survey, we measure the repeat-look reliability of embeddings from a frozen natural-image encoder (DINOv3 ViT-S/16). Standard single-look metrics, effective rank, clustering and a linear probe for coral, are all stable to the look, and the probe performs well (AUC 0.93). Yet the repeat-look reliability of the same embeddings is poor, with a distance-based intraclass correlation (dbICC) of 0.20 and nearest neighbours and clusters that barely agree across looks. This contradiction resolves as we find the probe learns a stable direction, whose ICC of 0.60 is 3.0 times that of the full embedding. Variance components, calculated from generalizability theory, attribute under a tenth of the within-cell spread to look acquisition geometry. The rest is cell-specific and cannot be separated without repeat passes at matched geometry. A sonar-pretrained encoder (BenthicDINO) and a classical SAS texture descriptor show the same pattern. For this dataset and the tested representations, uses that depend on patch identity fail, such as cross-pass comparison and retrieval, while uses at the level of habitat type (e.g. coral classification) do not. Because the standard metrics did not detect this, we argue that repeat-look reliability should accompany any evaluation of representations of the seafloor.

0.30

ObjectTwin: Measuring the Asset Correspondence Gap for Capture-Anchored Digital Twins

cs.CV ·2026-09-30 ·Zhenghe Guo
similarity 0.50
Abstract

Object-wise reconstruction increasingly inserts generated meshes into captured scenes as editable proxies for observed objects. This use creates a requirement absent from isolated-asset scores and pose estimates: at the captured metric state, the proxy should reproduce calibrated observations of the same instance. We present ObjectTwin, a scan-grounded measurement protocol that freezes the instance, cameras, scan-projected support and recorded depth, metric anchor, and evaluation denominator, then replaces only the object representation. The resulting asset correspondence gap measures lost observation agreement relative to scan-derived visible geometry without treating the scan as complete physical ground truth. Across two indoor RGB-D capture domains and two generation backends, visible, anchored generated assets lose 0.302-0.497 MaskIoU under this replacement. Every tested scene-level estimate is positive, while same-input generator preference reverses across capture domains. Coverage and overlap-depth analyses locate disagreement in both visible support and surface placement; the evaluated conservative pose refinement does not systematically recover it. These results establish capture correspondence as a separately measurable interface between generated-asset quality and stronger physical or task-level evaluation.

0.27

DrawScore: Evaluating Generated CAD Models against Engineering Drawings

cs.CV cs.SE ·2026-11-18 ·Haorui Chen, Shiteng Lu, Zhanyu Guo, Zaixi Li, Yunhe Ni +4 more
code/data similarity 0.49
Abstract

Automatic CAD generation is commonly evaluated with volumetric IoU, Chamfer Distance, and surface F-score, which barely penalize local errors that occupy only a small fraction of a part's volume or surface area, such as a misplaced hole or a slot on the wrong face, even though such errors are critical to manufacturing. We formalize these metrics in a unified integral form and show that the weight of a local error decays as the $(k+q)$-th power of its size, where $k$ is the dimension of the integration domain and $q$ is determined by the penalty function. Guided by this analysis, we propose DrawScore, which projects both models into three orthographic views with visible and hidden lines, as in engineering drawings, and applies a saturating penalty along the projected curves, so that the weight of a local error decays only linearly. Controlled experiments confirm the predicted decay orders, and on outputs of existing CAD generation agents, DrawScore exposes errors in outputs that IoU rates as nearly perfect. DrawScore further improves generation as a reinforcement learning reward and, for CAD generation from engineering drawings, serves as a test-time verifier without 3D ground truth or an additional reward model. Our code is available at https://github.com/UESTC-Simon/DrawScore.

0.48

Multi-Robot Scanner for Automated Full-Body Dermoscopic Imaging

cs.RO ·2026-09-09 ·Valerio Franchi, Rafael Garcia, Nuno Gracias, Ricard Campos, Josep Quintana +5 more
similarity 0.49
Abstract · Article under review by Robotics and Autonomous Systems

This paper outlines the specifications and design approach used to construct a full body imaging scanner capable of capturing skin lesions at a dermatoscopic level using cameras mounted on the end-effectors of four UR10 manipulators. The system possesses a view-planning algorithm capable of appropriately selecting the best camera position to acquire images of moles, a high-level controller to allow the manipulators to work simultaneously and a collision-detector that halts the manipulators when they make contact with an object or a person. We evaluate the system through real-patient full-body scans, comparing acquired images against contact dermoscopy and an existing total-body photography system (Vectra) across clinically relevant lesion features, and quantify true optical resolving power using a USAF 1951 resolution target, yielding a smallest resolvable feature size of 22.1 microns for our scanner compared to 8.8 microns for contact dermoscopy. Results show the scanner consistently outperforms Vectra across most clinically relevant features and achieves comparable performance to contact dermoscopy for the majority of features assessed. By acquiring dermatoscopic-quality images automatically and without contact, and without requiring a separate manual dermoscopic examination, the scanner closes part of the gap between total-body photography and handheld dermoscopy, suggesting potential for future integration into screening workflows.

0.25