ConRef: Auditing Reference Reliability in 2D/3D Registration Benchmarks

Jianfeng Yue, Feng Li, Tianyu Song, Julius Watrinet, Ulrich Eck, Nassir Navab

cs.CV ·submitted 2026-11-19 19:54 UTC · v1
benchmark

Abstract

Purpose: Accurate 2D/3D registration is crucial for image-guided orthopedic interventions, enabling the alignment of preoperative 3D anatomy with intraoperative X-ray observations for surgical navigation. Public benchmarks have facilitated the development and evaluation of increasingly accurate registration methods. However, as registration errors approach the uncertainty of benchmark reference poses, measured performance may be limited by reference inaccuracies rather than algorithmic errors alone. Methods: We propose Consensus Reference (ConRef), a multi-view framework for auditing reference poses in existing X-ray/computed tomography (CT) registration benchmarks. By jointly exploiting multiple X-ray observations, ConRef estimates an additional reference pose, quantifies its uncertainty, and identifies potential X-ray outliers. We validate the framework using independent anatomical evidence and a newly acquired X-ray/cone-beam CT (CBCT) phantom dataset with bead-based reference poses. Results: On our BeadPhant dataset, ConRef differed from independent bead-based references by 0.08-0.12 mm, while discrepancies with original references reached 2.06 mm on the Femur dataset. It also flagged 22 DeepFluoro X-rays as potential outliers. On Femur F5, reference choice changed the submillimeter success conclusions of the same registrations. Conclusion: Our findings demonstrate that reference discrepancies can influence the evaluation of high-accuracy 2D/3D registration methods. By providing an additional, independently validated reference and identifying potential inconsistencies, ConRef enables systematic auditing of existing benchmarks and supports more reliable evaluation of registration error.

Comment
12 pages, 6 figures, 1 table; includes 4 pages of supplementary material

Closest papers

Nearest neighbours by meaning across the whole index.

Landmark-Free and Scale-Blind Multi-View Registration of Preoperative Liver Models to Intraoperative Surfaces

cs.CV cs.AIcs.HC ·2026-10-16 ·Jiaming Feng, Gerardo Loza Galindo, Shahid Farid, Sharib Ali
similarity 0.68
Abstract · 10 pages

Augmented-reality guidance in laparoscopic liver resection requires aligning preoperative 3D liver models from CT/MRI with intraoperative surfaces. Monocular reconstruction in most cases cannot guarantee scale, albeit rigid-motion registration requires scale as an input. Our proposed framework ``SimCompose'' estimates the full similarity transformation $\Sim$, including scale, without relying on landmarks and applies the same transformation across multiple views with known relative geometry. However, reliable detection of registration failures remains challenging in surgical settings, where ground-truth alignment is generally unavailable. For this, we propose a geometry-based selector that evaluates candidate transformations without requiring ground truth. Large disagreement among these transformations is used to flag potentially unreliable registrations. Finally, we propose to use a non-rigid refinement based on a low-dimensional deformation model from Neo-Hookean simulations in the Simulation Open Framework Architecture (SOFA), without additional network training. SimCompose is trained exclusively on synthetic partial views. Its encoder processes point clouds normalised to a unit root-mean-square radius, without access to metric scale, and filters each view before multi-view fusion. Evaluation on unseen synthetic data (300 single-view pairs per run; 100 three-view registrations) shows that multi-view integration and candidate selection increase the success rate under stringent $\Sim$ accuracy criteria from 38.4% for a single-view, single-method configuration to 77%. Existing learning-based baselines do not satisfy these criteria even when provided with the exact scale. On five in-vivo patients with 92 keyframes, the rigid registration stage reduces surface error more than three-fold relative to learning-based baselines with external scale information.

0.12

XPos3R: Cross-Modal Transformer for Intraoperative 2D/3D Registration

eess.IV ·2026-09-09 ·Shiyan Su, Ruyi Zha, Hongdong Li, Xuelian Cheng, Zongyuan Ge
top venue similarity 0.67
Abstract · Accepted to ECCV 2026

Intraoperative 2D/3D registration, which aligns live X-ray images with preoperative volumes, is essential for image-guided interventions. Previous regression-based methods suffer from limited generalization, thus requiring time-consuming patient-specific retraining. Inspired by recent geometry foundation models such as DUSt3R, we propose XPos3R, a generalizable pose regression method that eliminates preoperative preparation. Unlike existing geometry models designed for homogeneous inputs, XPos3R extends this paradigm to multi-modal inputs, namely 2D X-rays and 3D volumes. Specifically, we introduce an asymmetric encoder-decoder architecture that improves cross-modal feature alignment while maintaining computational efficiency. To scale training under limited medical data, we adopt an anatomy-specific data curation strategy and construct million-scale synthetic datasets. Evaluated on real-world benchmarks, a single pretrained XPos3R surpasses patient-specific methods in both accuracy and robustness. With test-time optimization completed in seconds, it further reduces the 3D error to <4 mm and the reprojection error to <1 mm. The strong generalization, accuracy, and efficiency of XPos3R highlight its clinical potential, while its asymmetric framework may inspire broader cross-modal vision geometry tasks.

0.47

A thorough review on Deep Learning approaches to 2D-to-3D Registration in Medical Imaging

eess.IV cs.CVcs.LGphysics.med-ph ·2026-11-12 ·Andrea Borghesi, Julia van Beurden, Maarten van Alphen, Michiel van den Brekel, Luc Karssemakers +4 more
similarity 0.66
Abstract · 51 pages, 4 tables, 8 figures

2D-to-3D image registration is a key component for several medical imaging purposes such as intraoperative guidance, enabling the alignment between preoperative 3D volumes and real-time 2D images. While conventional optimisation-based methods often struggle with non-convex objectives, sensitivity to initialisation, and high computational demands, deep learning (DL) has emerged as a promising alternative, offering improved alignment robustness and the potential for real-time performance. This review provides a comprehensive analysis of DL frameworks developed to address the challenges inherent in 2D-to-3D registration. We first outline how core concepts of DL are adapted to the registration problem. We then examine recent methodological advancements from multiple perspectives, including pipeline design, architectural innovations, and domain adaptation strategies. Particular attention is given to quantitative metrics, highlighting how performance is defined and measured across studies. Across the 41 included studies, we find that direct regression is the most common pipeline (23 studies, against 18 iterative ones), that hybrid CNN-attention architectures are gaining ground, and that research remains heavily concentrated on X-ray-to-CT registration. We conclude by identifying the absence of per-case uncertainty estimation and the strong neglect of temporal or sequential modelling as the two methodological gaps most consequential for clinical readiness, and discuss state-space models as a way to add temporal memory within intraoperative latency budgets. Further opportunities lie in more principled domain adaptation and in the integration of foundation models for representation learning.

0.19

Bridging the Markerless Tracking Validation Gap: Intraoperative X-ray Workflow Integration

cs.CV ·2026-10-15 ·Connor Daly, Salvatore Russo, Jinendra Ekanayake, Daniel S. Elson, Ferdinando Rodriguez y Baena
top venue similarity 0.66
Abstract · This version was submitted to MICCAI 2026 for review, see journal reference for published version

Markerless intraoperative tracking of spinal anatomy via RGB-D sensors is a promising alternative to invasive bone-anchored fiducials, yet no existing clinical dataset provides independent subsurface ground truth for validating these methods. We address this gap with a clinically viable pipeline that derives per-vertebra 6-DoF pose from routine intraoperative C-arm fluoroscopy, co-registered to the RGB-D camera frame through a multimodal fiducial array detectable in both imaging modalities. Critically, the pipeline requires no additional radiation, instrumentation, or deviation from standard surgical workflows, relying solely on the fluoroscopic images already acquired during routine level checks. A calibrated transform chain links the vertebral pose recovered via multi-view 2D-3D CT-to-fluoroscopy registration to the RGB-D coordinate frame, enabling direct comparison of any markerless registration estimate against a subsurface reference. Ex vivo validation against optically tracked ovine vertebrae confirms end-to-end accuracy of 2.06 +- 0.29 mm and 3.35 +- 0.93 degrees, sufficient to serve as independent ground truth for methods with substantially larger errors. We demonstrate the pipeline's utility by evaluating two markerless registration strategies on clinical data spanning 11 vertebrae across 1,500 frames from three surgical sequences: the first such evaluation against an independent subsurface reference in a clinical setting. The proposed framework provides reusable infrastructure for benchmarking emerging markerless tracking methods on real surgical data.

0.42

ActiveReg: Information-Driven Active Regional Probing for Partial-to-Full Bone Registration

cs.RO ·2026-10-07 ·Tiancheng Li, Yingyu Wang, Peter Walker, Liang Zhao, Shoudong Huang
similarity 0.65
Abstract · Preprint

Accurate bone registration is essential for orthopedic surgical navigation and robotic assistance. In a common workflow, the surgeon needs to identify and probe a number of prescribed locations on the exposed bone surface to obtain data points for registration, which can be difficult and time-consuming under limited surgical exposure. Reducing the number of required points while providing clear probing guidance would ease the surgeon's acquisition task intra-operatively. We present ActiveReg, a closed-loop framework that recommends probing regions rather than individual points, allowing flexibility in the exact contact location. A D-optimal planner that takes into account the already acquired points and the uncertainty of current registration information helps achieve accurate registration with fewer points. An online assessment combines pre-update innovation consistency with uncertainty at predefined surgical task locations improves the reliability of completion decision, without requiring ground truth. Simulations across four anatomical scenarios demonstrated that ActiveReg can achieve competitive accuracy compared with baseline registration methods while using substantially fewer acquired points. Real phantom experiments with optical and electromagnetic tracking demonstrated comparable mean target registration error to the Gradient-SDF framework, using only 24-28 acquired points instead of 771-1263.

0.25

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.64
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

Spectral Consistency-Guided Multiview Point Cloud Registration for Low-Overlap Scenes

cs.CV ·2026-09-11 ·Tianyu Li, Yanghong Lin, Shudong Zhou, Kui Yang, Jingru Zhang +2 more
code/data similarity 0.63
Abstract

Multiview point cloud registration is particularly challenging in low-overlap scenes, where reliable correspondences are limited and incorrect pairwise transformations can affect global pose estimation. In addition, registering all scan pairs is computationally expensive because many pairs provide weak geometric information. To address these problems, we propose GMPCR, a non-learning-based spectral consistency-guided framework for efficient and robust multiview point cloud registration. GMPCR builds a refined second-order compatibility structure from initial correspondences and uses its dominant spectral response to evaluate both correspondence reliability and scan-pair confidence. This allows unreliable correspondences to be filtered and informative scan pairs to be selected before relative transformation estimation, leading to a sparse pose graph and reduced pairwise registration cost. For each retained scan pair, maximal-clique-based hypothesis generation is used to estimate reliable relative transformations. The resulting pose graph is further refined by an adaptive history-aware synchronization scheme, in which the effect of residual history is adjusted according to changes in the global rotation residual. A recovery mechanism also allows down-weighted edges to regain confidence when their global consistency improves. Experiments on 3DMatch, 3DLoMatch, ScanNet, and ETH demonstrate the effectiveness of GMPCR. It achieves registration recalls of 97.2% and 89.6% on 3DMatch and 3DLoMatch, respectively, while maintaining competitive performance on ScanNet and ETH. The results show that GMPCR provides a favorable balance among registration accuracy, robustness to low overlap, and computational efficiency. The code is publicly available at https://github.com/swccj/gmpcr.

0.31

SCoPE-Reg: Efficient Rigid Ultrasound Slice-to-Volume Registration via State-Space Correlation and Closed-Form Pose Estimation

eess.IV cs.CV ·2026-08-28 ·Niklas Schwarz, Jens Kleesiek, Moritz Rempe
publishedcode/data similarity 0.63
Abstract · Accepted to Winter Conference for Applications in Computer Vision 2027, Orlando, Florida

Ultrasound-guided interventions can require localization of an untracked 2D frame within a 3D anatomical reference. Rigid slice-to-volume registration (SVR) estimates this six-degree-of-freedom pose but remains challenging because of limited anatomical context, acoustic artifacts, and view-dependent appearance. Existing methods often use dense cross-attention, whose cost scales with the product of slice and volume token counts, or direct pose regression that lacks explicit correspondence constraints. We introduce SCoPE-Reg, combining dual-input state-space slice-volume interaction, dense 3D coordinate prediction, and parameter-free weighted Kabsch estimation. On SVR tasks from CAMUS and $μ$-RegPro, SCoPE-Reg yields mean target registration errors of $0.73$ mm and $2.27$ mm against $1.24$ mm and $2.63$ mm for the best-performing baseline, reduces peak error on CAMUS by 56% ($12.5\to5.5$ mm), and registers $100%$ and $80%$ of frames within $3$mm. On CAMUS at $128^2$ it retains the lowest error at increasing pose-perturbation magnitude. It holds $6.49$ M parameters independent of resolution, sustaining $51$ FPS at $512^2$. By coupling correspondence-based accuracy with bounded worst-case error and resolution-independent cost, SCoPE-Reg becomes viable at native acquisition resolution during intervention, whereas previous methods had to compromise on accuracy, reliability or frame rate. Supplementary code: https://github.com/TIO-IKIM/SCoPE-Reg.

0.50