CS Paper Radar

COMPASS: Cross-modal Observation with Multi-Path Adaptive Stopping and Selection for Early Time Series Classification

Cheng-En Chung, Yujia Wu, Oscar Tai-Yuan Chen, Vincent S. Tseng

cs.LG ·submitted 2026-11-20 03:33 UTC · v1

Abstract

Early time-series classification (ETSC) balances predictive performance against the amount of observed data. In multimodal settings, modality-associated and fused branches may differ in predictive ability at the same observed prefix, motivating joint decisions about when to stop and which branch should provide the final prediction. We propose COMPASS, a two-stage framework that preserves two modality-associated temporal branches and one fusion branch. The first stage combines cross-modal feature exchange and gated fusion with branch-wise supervision at every prefix. The second stage optimizes a shared four-action controller to continue observation or terminate through one of the frozen branches. Experiments on six physiological and wearable datasets compare COMPASS with multimodal adaptations of five ETSC baselines. COMPASS achieves the best average ranks in accuracy-earliness harmonic mean, AUROC, and earliness within this comparison set. At identical learned stopping times, branch selection improves mean accuracy over fusion readout on five of the six datasets, with gains of 2.35 and 2.16 percentage points on ISRUC-Sleep and UCDDB, respectively. To the best of our knowledge, this is the first work on joint stopping and branch selection for multimodal early time series classification.

Closest papers

Nearest neighbours by meaning across the whole index.

Efficient Multimodal Inference through Adaptive Acquisition and Sequential Fusion

cs.LG ·2026-10-05 ·Payal Mohapatra, Haodong Yang, Yueyuan Sui, Stephen Xia, Benjamin Lundell +1 more
similarity 0.66
Abstract

Multimodal systems often encode every available input, even when a subset suffices for prediction. Adaptive acquisition can reduce this cost by using predictions from incrementally fused evidence to decide which modality to encode next and when to stop. However, sequential fusion makes these predictions order-dependent, so decisions based on them may need to distinguish factorially many histories of the same acquired set. We introduce SemARC, which couples a Sequential Modality Aggregator (SeMA) with an Adaptive Runtime Controller (ARC) and uses acquired evidence to select each modality before its encoder runs. SeMA executes only selected encoder and fusion branches, updates a fixed-size state, and predicts after each acquisition without recomputing earlier branches. We supervise every acquisition prefix under randomized modality subsets and orders to encourage consistent predictions across acquisition orders. ARC combines a set-dependent marginal-utility prior with residual fitted-Q learning to select the next available modality or stop, without inspecting unacquired inputs or retaining acquisition order. Across six multimodal classification datasets and eleven baselines, SemARC achieves 3.2% higher macro-F1 and 61.4% lower total inference GFLOPs on average relative to each dataset's most accurate baseline. End-to-end latency falls by 44.0% across GPU and CPU and by 47.2% on Android INT8 relative to the fastest measured baseline, on average. Under varying runtime modality missingness, SemARC still skips available modalities, matching or exceeding the best baseline macro-F1 in 21 of 24 conditions with 14.8% lower total GFLOPs on average. SemARC thus offers a practical path toward efficient multimodal inference across heterogeneous devices.

0.23

SOTER: A Generative Time-Series Foundation Model for Wearable Human Physiological Signals

cs.LG cs.AI ·2026-09-15 ·Fangke Chen, Sirry Chen, Wei Chen, Zhongyu Wei
similarity 0.62
Abstract

Time-series foundation models have demonstrated strong cross-domain transfer, yet their common architectural assumptions remain poorly aligned with wearable physiological signals, which are multichannel, irregularly sampled, noisy, and governed by coupled continuous-time dynamics spanning distinct spectral scales. We present SOTER, a generative foundation model for wearable physiological time series that unifies cross-channel coupling, spectrum-guided expert specialization, and continuous-time latent evolution within a single pre-training framework. SOTER combines a spatial feature-aware backbone that models inter-signal dependencies, a power spectral density (PSD)-guided mixture-of-experts layer that routes representations to experts associated with fixed spectral bands through an inspectable, non-learned rule, and a neural controlled differential equation decoder that supports prediction and imputation at arbitrary timestamps. We pre-train SOTER on 226 billion time points from five public physiological datasets and evaluate the same pre-trained model across out-of-distribution zero-shot forecasting, frozen-encoder linear-probe classification, and continuous-time imputation on wearable benchmarks. SOTER achieves the best RMSE on 4 of 6 datasets and the best MAE on 5 of 6 in zero-shot forecasting, the highest average Macro-AUROC in classification, and the lowest imputation error on all six datasets at 75% missingness. It further remains robust to additive acquisition noise, matching or surpassing baselines evaluated on clean inputs even under the strongest corruption. These results indicate that domain-specialized foundation models for wearable physiology benefit from jointly modeling channel structure, spectral scale, and continuous-time dynamics.

0.45

Motor Imagery Classification Using Hybrid Cross-Subject Class Mixup and Selective Attention

cs.LG ·2026-11-16 ·Jiwon Kim, Chae-Won Lee, Jong-Seok Lee
similarity 0.61
Abstract

Motor imagery (MI) enables a brain-computer interface (BCI) to decode movement intentions without overt movement. Hybrid electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS) classification combines complementary signals, but inter-subject variability and the design of information exchange between modalities affect generalization to new subjects. We propose a framework that combines Cross-Subject Class Mixup (CSCM) with Selective Attention. CSCM aims to construct new training data to make the model robust against inter-subject variability. It independently selects EEG and fNIRS donor trials from other training subjects within the anchor class and mixes each modality while preserving the original label. Selective Attention provides an effective way to simultaneously model the temporal signal characteristics and fuse the two modalities. It retains causal temporal self-attention for EEG and uses a classification token (CLS) to integrate both modalities, without fNIRS attention updates or direct cross-modal temporal-token attention. Leave-one-subject-out (LOSO) evaluation across 28 subjects on a public EEG-fNIRS dataset yields a mean balanced accuracy (BA) of 76.85% and a macro-averaged F1 score (Macro-F1) of 76.58%. The proposed model achieves the highest mean performance among five reimplemented baselines. We also examine the contributions of CSCM and Selective Attention through modality-specific mixing and donor-policy comparisons, temporal-policy comparisons, interventions on direct cross-modal paths, and component ablations.

0.18

LingSante-Pulse: Unified Physiological Pretraining through Random-Feature Prediction and Cross-Modal Alignment

cs.LG cs.AI ·2026-11-20 ·Linxiao Yang, Wenwei Wang, Tian Zhou, Bingqing Peng, Zihao Zhang +3 more
similarity 0.61
Abstract

Clinical monitoring and wearable devices capture complementary physiological signals, but their partially overlapping modality coverage makes within-signal information and cross-modal relationships difficult to exploit jointly. We introduce LingSante-Pulse, a unified, general-purpose and flexible physiological representation framework that learns from these heterogeneous recordings. A shared, signal-conditioned encoder processes each physical channel independently and supports different numbers and combinations of signals for multimodal assessment and single-sensor inference. Pairwise cross-modal alignment, structured random-feature prediction (RFP) and masked waveform reconstruction jointly learn physiological relationships and preserve informative within-signal structure. Across 38 general physiological task configurations spanning PPG, ECG, EEG and EMG, the frozen encoder achieves the best dataset-balanced mean rank in each domain. In sleep assessment, multimodal staging on the HMC dataset and EEG-only staging on the Sleep-EDF dataset reach Macro-F1 scores of 0.7784 and 0.7941, respectively, while single-lead ECG apnea screening achieves an AUROC of 0.9183. Controlled experiments show that function prediction and waveform reconstruction provide complementary supervision for retaining temporal and rhythmic information. Representations learned under continually refreshed random supervision generalize to unseen teacher realizations, and correct auxiliary modality correspondence improves respiration-only representations. These results demonstrate that a single encoder can learn reusable physiological features across signal types, prediction targets and sensor configurations from partially overlapping recordings.

0.22

Learning Multimodal Sensor Fusion with JEPA Representations for Breathing Activity and Pose Recognition

cs.CV cs.AI ·2026-10-11 ·Yunxiang Luo, Constantino Álvarez Casado, Xiaoting Wu, Nhi Nguyen, Le Nguyen +2 more
hot direction similarity 0.60
Abstract · 6 pages, 2 figures, 3 equations, 4 tables, conference paper

Predictive video representations do not by themselves specify how a multimodal system should handle missing sensors. We transfer frozen V-JEPA2 features to a set of heterogeneous sensors comprised by RGB video, depth video, and radar time series. A shared fusion model uses modality queries, fixed sensor slots, and explicit availability to classify breathing activity and pose from all seven non-empty sensor subsets. The contribution is a controlled evaluation of subset supervision, pooling capacity, and representation transfer on 39 OMuSense-23 subjects with five subject-group folds and three seeds. With matched downstream parameter counts, the final model reaches recording-level activity macro-F1 of $75.23%\pm0.60$ averaged across seven subsets. Supervising all subsets in each batch improves the matched query-pooling control by 1.923 percentage points (conditional 95% subject-bootstrap interval [0.647, 3.209]), while query pooling shows no clear advantage over matched mean pooling under balanced supervision. Radar probes support transfer beyond pooled wavelet pixels, 64-token inference approximately preserves mean activity performance, and the tested Consensus-JEPA loss adds no measured benefit against its exact control.

0.36

WearableBridge: Task-Guided Latent Transport for Free-Living Activity Recognition

cs.LG ·2026-11-06 ·Jingjing Zou, Yixin Wang
code/data similarity 0.60
Abstract · 26 pages, 5 figures, 11 tables. Code and interactive demo: https://github.com/jingjingz/WearableBridge

Wrist-worn accelerometers make activity monitoring feasible at scale, but incidental arm motion, device orientation, and shifting context blur the signal that separates activities. Calibration studies supply higher-quality references such as concurrent thigh recordings or supervised laboratory wrist sessions, but they are expensive, cover few participants, and are rarely available at deployment. How can limited reference data improve recognition for participants who wear only a wrist device? We propose WearableBridge, which holds the reference encoder and classifier fixed and learns a task-guided transport map, the bridge, that carries each wrist feature into the region the classifier associates with its activity. Reference features or the classifier's predictions indicate the destination, and a classification loss penalizes wrist features that land in the region of another activity. We instantiate WearableBridge with three bridges: Mapper regresses onto reference features, Distillation matches the classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features. On 40 held-out free-living PAAWS participants, all three bridges improve macro-F1 in every training run, and the strongest, MeanFlow, raises mean macro-F1 from 35.1% to 56.0% with concurrent thigh references (Thigh2Wrist), and from 54.0% to 63.5% with group-matched laboratory wrist references (Lab2Freeliving). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.8% to 54.7%. The gains replicate on selfBACK, hold across four reference encoders, and grow with temporal context. A study can therefore collect reference recordings for a calibration subset and improve wrist-only recognition for every other participant, training only a bridge of 0.13 to 2.44 million parameters while the reference encoder and classifier stay unchanged.

0.26

SwitchPFN: Shared Switching Dynamics for Frozen In-Context Time Series Classification

cs.LG ·2026-09-24 ·Zhenyi Zhu, Jacqueline Pang, Peilin Shen, Tianyi Song, Tingwei Zhang +5 more
similarity 0.60
Abstract

Tabular foundation models (TFMs) provide a promising route to time-series classification, but their effectiveness depends on how sequential data are converted into tabular representations. Existing representations face two challenges: global aggregation can lose the order of temporal evolution, while features computed in independently fitted coordinate systems may not have consistent meanings across sequences. We therefore view representation design for TFMs as a problem in its own right: the representation should preserve local temporal transitions while maintaining a shared feature definition across samples. We propose SwitchPFN, which learns a shared projection and regime codebook from the training sequences, making local dynamic operators and transition features directly comparable across samples. Across the evaluated benchmarks, SwitchPFN achieves the highest mean accuracy among the evaluated methods, improving over the strongest baseline by 4.47% relatively. Ablation studies, parameter sensitivity analyses, and reduced-training-data experiments further examine the contributions of the representation, its main design choices, and its behavior when labeled data are limited.

0.22

RTSM: Adapting Recursive Models to Multivariate Time-Series Classification

cs.LG ·2026-10-16 ·Georg Tenzing, Anna Tegon, Luca Benini, Thorir Mar Ingolfsson
similarity 0.60
Abstract · 33 pages, 6 figures

Accurate multivariate time-series classification requires extracting temporal features and integrating information across a sequence. Weight-tied refinement offers a way to repeatedly process these features without allocating new parameters at each stage. Applying this principle to time series requires choosing both a temporal representation and a latent-state organization suited to classification. We introduce the Recursive Time-Series Model (RTSM), which combines a learned convolutional temporal tokenizer, single-state weight-tied refinement, and a pooled classification readout. Across all 30 UEA datasets, RTSM achieves 72.81% mean accuracy under validation-based configuration and checkpoint selection, the highest observed mean among the 17 evaluated deep-learning models and 1.60 percentage points above MambaSL. Ablations on eight datasets favor the proposed tokenizer over a simple convolutional embedding and the single-state model over the tested two-state variants. The complete classifier reaches 86.10% mean accuracy versus 84.79% for a separately trained tokenizer-only classifier. These findings identify temporal encoding and state organization as key design choices for adapting recursive architectures to time series. The resulting classifier combines competitive accuracy with a shared refinement module whose parameter count is independent of computational depth.

0.16