CS Paper Radar

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

Yiwen Qiu, Che Sun, Shu Shen, Wentao Wang

cs.AI ·submitted 2026-11-20 09:56 UTC · v1

Abstract

On-premise clinical AI agents must auto-accept high-confidence diagnoses, deferring others to clinician review, yet token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute. We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol. Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels. Calibration freezes a nominal top-50% threshold, selecting single-run, five-run consistency, or full-deferral tiers by whether the one-sided 95% Wilson lower confidence bound of pass rate among accepted cases meets the 95% clinical target line. Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases, MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute; CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier, capping calibration false-certification rate at 0.00%-3.50%.

Closest papers

Nearest neighbours by meaning across the whole index.

AI Morbidity and Mortality: A Framework for Clinical AI Failure Review

cs.AI cs.HC ·2026-08-31 ·Paulius Mui, Dean F. Sittig, Steve Labkoff, Sanjay Basu
similarity 0.68
Abstract

Clinical artificial intelligence is increasingly embedded in real-world care, yet existing safety mechanisms are poorly suited to reconstructing and learning from individual AI-related errors and near-misses. Aggregate model monitoring can identify performance changes, and traditional patient safety reporting can capture adverse events, but neither is designed to explain how risk emerges across the interaction among AI systems, clinicians, workflows, and institutional controls. We propose AI Morbidity and Mortality (AI M&M), a structured, blameless framework for case-based review of clinical AI failures. The framework combines standardized case intake, evidence preservation and investigator-level reconstruction, tool-in-loop attribution, and corrective-action tracking. Each event is classified across four linked dimensions: Trigger - Mechanism - Clinical Pathway - Corrective Action, separating the condition that exposed a vulnerability from the process that produced risk, its consequence for care, and the remediation assigned. We demonstrate the framework using five illustrative outpatient medication and clinical decision-support cases; two clinician reviewers independently applied all four classification axes and reached agreement across all 20 axis-level classifications. AI M&M is intended to complement, rather than replace, model monitoring, patient safety reporting, and regulatory oversight by converting individual AI-in-workflow failures into actionable institutional learning. Prospective evaluation across institutions, AI systems, and clinical settings is needed.

0.13

Safe to Stop? Risk-Constrained Stopping for Sequential Clinical Diagnosis Agents

cs.AI ·2026-09-09 ·Yuexin Wu, Vasile Rus
benchmark similarity 0.67
Abstract

Clinical diagnosis agents must decide not only what test to request next, but also when to diagnose or defer. Existing agent benchmarks largely evaluate accuracy after fixed or unconstrained interaction, leaving autonomous stopping reliability implicit. We present Cros, a risk-constrained stopping layer combining state-wise error ranking, policy design on disjoint development splits, and LTT-style exact tests of selective diagnostic error and minimum autonomous coverage for complete sequential policies. Its finite-sample guarantee requires the candidate family, testing rule, and any randomization to be frozen before calibration labels are accessed. On a 1,834-episode MIMIC-derived abdominal-pain benchmark, the full ranker achieves exploratory state-error AUROC 0.853, compared with 0.715 for maximum class probability and 0.552 for the backbone's native stop score. On the previously viewed 367-episode evaluation split, analytically averaging over the frozen Cros weights yields 16.9% selective error at 78.8% coverage, cost 5.57, and 0.68 tests, versus 30.8% error at 100% coverage, cost 8.14, and 1.53 tests under native stopping. Forced continuation is non-monotone: error is 28.3% with HPI alone and 34.3% after full workup. However, the uniform-weight mixture ablation is cheaper on this viewed split despite missing the locked development margins, and Cros nominally satisfies the joint criterion in only 6 of 20 development resplits. Because evaluation labels were inspected during earlier development, these findings provide exploratory feasibility and audit evidence, not a confirmatory safety certificate.

0.51

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

cs.AI cs.CL ·2026-10-15 ·Zihao Zheng, Junyi Yao, Baichuan Li, Jiayu Long
benchmark similarity 0.67
Abstract · 8 pages, 5 figures

Trustworthy biomedical AI requires reliable action selection when evidence is missing, stale, conflicting, or late, not only accurate answers on static inputs. We instantiate an episode-level evaluation protocol as 400 synthetic healthcare workflow episodes: 40 hand-authored semantic seeds across four task classes, two surface parameterizations, and five controlled variants, scored on ANSWER/ASK CLARIFICATION/ABSTAIN/ESCALATE under a pre-declared 5:1 missed-versus-unnecessary escalation cost. Reference actions are single-author study-policy labels, not clinician-adjudicated ground truth. Across five open-weight configurations (1.7B--9.7B), clean decision accuracy reaches 0.97, yet uncertainty-prompted models miss 32--97% of required escalations. The stronger 9.7B configuration narrows but does not remove the gap, falling from 0.97 clean accuracy to 0.78 under conflict. Verbalized confidence is inconsistent (ECE 0.10--0.54; failure AUROC 0.48--0.77), and a development-tuned confidence-only policy yields no utility gain. A transparent workflow-aware controller improves 5:1 utility for every model and reduces missed escalations to 0.12--0.24, at specificity 0.83--0.93. However, a 30-concept lexical stress test reduces each rule detector's recall from 1.00 on trigger phrases to 0.00 on unseen paraphrases, limiting the controller claim to this benchmark. Seed-clustered statistics, ablations, cross-task transfer, raw outputs, and manifests are packaged for audit. The results motivate explicit workflow-state evaluation while showing that apparently effective routing controls need their own generalization tests.

0.46

Scaling large language model-assisted line-of-therapy adjudication with human-in-the-loop evidence-calibrated selection

cs.LG q-bio.QMstat.AP ·2026-11-15 ·Olatunji Oni, Sanhita Sengupta, Marc De Benedetti, Nathanial Eddy
similarity 0.66
Abstract · 12 pages, 4 figures

Large language models (LLMs) have enabled the ability to scale clinical adjudication tasks traditionally dependent on exhaustive manual review. Line-of-therapy (LoT) adjudication, a major bottleneck in oncology cohort construction, is a prime example. Line boundaries must be inferred from longitudinal treatment histories according to nuanced, study-specific definitions, at every regimen transition for every patient. LLMs can apply this adjudication at scale, but their reliability varies across patients. Treatment histories differ in complexity, and ambiguous or atypical patterns depend on expert clinical judgment. Reliable automation thus requires verified support for model assignments and the ability to identify cases that warrant manual review. Here, we present evidence-calibrated selection (ECS), a human-in-the-loop framework for scaling LLM-assisted LoT adjudication. ECS derives confidence from observed clinician adjudications, prioritizes patients with the least-supported assignments for follow-up review, and returns completed adjudications to the model as precedent. As the evidence base grows, ECS continuously calibrates confidence to estimate residual error, thus enabling more efficient use of clinician time. In simulations on 136 clinician adjudicated patients with multiple myeloma, ECS achieved a residual error of 5% after review of 44.6% of patients, compared to 62.2% when review was directed by LLM self-reported confidence and 81.9% under random sampling. These results support a scalable approach to study-specific LoT adjudication, using clinician evidence to inform automated predictions, minimize error, and reduce review burden.

0.21

Scalable Evaluation of Medical AI using Evidence-based Practice Recommendations

cs.AI cs.HC ·2026-11-20 ·Teya Bergamaschi, Bijal Rajput, Akshay Goel, Matthew Thompson, Jacqueline Shreibati +12 more
similarity 0.66
Abstract

Rigorously evaluating medical artificial intelligence (AI) requires testing open-ended clinical management across diverse presentations and stages of care. However, existing benchmarks rely on manual expert authoring, limiting coverage across conditions, conditional care pathways, and evolving guidelines. We develop an automated pipeline that extracts and verifies structured clinical criteria and branching decision trees from practice recommendations to generate scenarios spanning the care continuum, including nuanced presentations and practice variations across regions and guideline editions. Applied to 436 BMJ Best Practice clinical monographs (354 US, 82 International), this yields 3,200 scenarios spanning differential diagnosis, investigations, treatment, and complications, plus targeted suites for regional specificity (731 US/International pairs) and temporal freshness (630 scenarios). To grade responses, we develop a clinician-calibrated autorater that scores management plans on a 4-point rubric stratifying deviations by clinical severity. Across Gemini models, scaling improves adherence, while web search (+0.8 percentage points [pp] on average) and multi-sample synthesis (+2.2 pp) combine additively (+2.8 pp). In context, full monographs consistently trail condensed excerpts. On targeted suites, web search narrows international performance gaps (+4.2 pp) and improves adherence to newly updated guidance (+4.6 pp). In a study with Primary Care Physicians (n = 9) across 200 scenarios, AI assistance raises adherence from 50.5% to 70.0%, driven largely by fewer clinical omissions. Overall, our results demonstrate a scalable evaluation setup using an evidence-based corpus originally written to guide human clinical decision-making, and demonstrate its viability to assess medical AI and its assistance on clinician decision-making.

0.18

Decide, Ask, or Defer: Clinical LLMs under Incomplete Evidence

cs.AI ·2026-10-03 ·Mingzhan Yang, Weili Wu
published similarity 0.66
Abstract · Accepted to the Main Track of the NeurIPS 2026 GenAI4Health Workshop

Clinical LLMs must decide not only what diagnosis to produce, but also whether the available evidence is sufficient for autonomous decision making. Binary DECIDE/ABSTAIN formulations merge distinct non decision states and do not explicitly evaluate information acquisition. We introduce a DECIDE/ASK/DEFER formulation together with a blinded protocol that prevents models from using evidence completeness metadata. We evaluate Qwen, Gemini, and GPT on 200 matched clinical evidence states constructed from DDXPlus. The models show substantial differences in action selection under identical evidence, with disagreement in 137 of 200 states. For Qwen, a matched targeted versus random analysis shows that selected information changes the likelihood of a subsequent autonomous decision more clearly than diagnostic correctness. Its matched DECIDE/ABSTAIN baseline further reveals a safety autonomy tradeoff: the three action policy rescues some erroneous autonomous decisions but also removes some correct autonomous deci sions. These results show that separating information acquisition from clinician deferral exposes behavior that binary abstention hides, without yielding a uniformly improved decision policy.

0.31

Beyond Uncertainty Reduction: Calibrated Planning for Interactive Diagnosis

cs.AI ·2026-08-28 ·Yue Zhou, Haiyang Zhou, Jin Zhang, Kong Wang, Zihao Rao +3 more
code/data similarity 0.66
Abstract

Interactive medical diagnosis requires an agent to gather patient evidence through sequential questions before committing to a diagnosis. Large language models (LLMs) now make such consultations feasible, and existing approaches typically select questions by how much they reduce uncertainty among candidate diseases. However, this objective is insensitive to the unequal clinical costs of diagnostic errors and omitted severe alternatives, so minimizing uncertainty need not minimize final diagnostic loss. To bridge this gap, we propose CaRDI (Calibrated Risk for Diagnostic Interaction), a planning framework built around a clinical loss combining primary diagnosis error with severity-weighted differential omission. Diagnostic and safety beliefs estimate the two loss components, while conformal residual calibration corrects for underestimation from partial evidence. The calibrated risk then guides question selection and stopping by balancing expected risk reduction against interaction cost. Experiments on multiple medical benchmarks show that CaRDI improves accuracy while requiring fewer questions. Further analysis shows that replacing entropy with clinical risk as the planning objective reduces clinical loss by 21.5% and decreases severe omissions. Our code is available at https://anonymous.4open.science/r/CaRDI-A940/.

0.28

Safe Reinforcement Learning for Multi-Turn Clinical Agents: When Dense Rewards Beat Outcome Rewards

cs.LG cs.AIcs.CL ·2026-11-09 ·Brendan P. Murphy, Agustina Saenz
code/data similarity 0.66
Abstract · 31 pages, 11 figures. Code: https://github.com/csbrendan/Safe-Reinforcement-Learning-for-Multi-Turn-Clinical-Agents

Reinforcement learning with verifiable rewards is increasingly used to improve language model reasoning, yet its effects on sequential decision procedures remain poorly understood. We study this problem in clinical multi-turn agents that must decide what information to request, when to stop gathering evidence, and which action to take. We introduce three controlled environments: medication refill triage, acute diagnostic work-up, and dosing titration, each with hidden clinical states, query costs, exact adaptive oracles, and deterministic outcome verifiers. Across these tasks, outcome-only group relative policy optimization often improves aggregate reward while producing undesirable procedures, including premature commitment, one-question collapse, and failures on rare high-risk cases. In diagnostics, assigning dense credit to questions that reduce uncertainty improves held-out value and moderate-case support across three training seeds relative to outcome-only reinforcement learning, without the high-risk seed collapse observed under outcome-only training. Separating exploration from exploitation further increases high-risk support at its best checkpoint, but at the cost of excessive information gathering on low-acuity cases. Additional experiments show that the optimal strength of process credit is task-dependent; that after a supervised warmup that already gathers carefully, reinforcement learning raises aggregate reward by trimming questions while degrading high-risk performance; and that reinforcement learning does not reliably repair rare behavior gaps inherited from biased supervised data. Verifiable final outcomes are therefore insufficient for training reliable multi-turn agents: reward design must account for the procedure used to reach an answer, and evaluation must distinguish adaptive information gathering from reward-exploiting shortcuts.

0.26