CS Paper Radar

Safe to Stop? Risk-Constrained Stopping for Sequential Clinical Diagnosis Agents

Yuexin Wu, Vasile Rus

cs.AI ·submitted 2026-09-09 03:46 UTC · v1
benchmark

Abstract

Clinical diagnosis agents must decide not only what test to request next, but also when to diagnose or defer. Existing agent benchmarks largely evaluate accuracy after fixed or unconstrained interaction, leaving autonomous stopping reliability implicit. We present Cros, a risk-constrained stopping layer combining state-wise error ranking, policy design on disjoint development splits, and LTT-style exact tests of selective diagnostic error and minimum autonomous coverage for complete sequential policies. Its finite-sample guarantee requires the candidate family, testing rule, and any randomization to be frozen before calibration labels are accessed. On a 1,834-episode MIMIC-derived abdominal-pain benchmark, the full ranker achieves exploratory state-error AUROC 0.853, compared with 0.715 for maximum class probability and 0.552 for the backbone's native stop score. On the previously viewed 367-episode evaluation split, analytically averaging over the frozen Cros weights yields 16.9% selective error at 78.8% coverage, cost 5.57, and 0.68 tests, versus 30.8% error at 100% coverage, cost 8.14, and 1.53 tests under native stopping. Forced continuation is non-monotone: error is 28.3% with HPI alone and 34.3% after full workup. However, the uniform-weight mixture ablation is cheaper on this viewed split despite missing the locked development margins, and Cros nominally satisfies the joint criterion in only 6 of 20 development resplits. Because evaluation labels were inspected during earlier development, these findings provide exploratory feasibility and audit evidence, not a confirmatory safety certificate.

Closest papers

Nearest neighbours by meaning across the whole index.

Evidence sufficiency assessment enables cost-effective review allocation in on-premise clinical AI agents

cs.AI ·2026-11-20 ·Yiwen Qiu, Che Sun, Shu Shen, Wentao Wang
similarity 0.67
Abstract

On-premise clinical AI agents must auto-accept high-confidence diagnoses, deferring others to clinician review, yet token probabilities and self-reported confidence miss errors, while more reliable five-run consistency incurs fivefold compute. We propose training-free decision-point evidence sufficiency assessment and a three-tier sequential triage protocol. Masking reasoning and diagnosis, the same 4B model scores sufficiency from objective evidence via prior-debiased probabilities over five ordered levels. Calibration freezes a nominal top-50% threshold, selecting single-run, five-run consistency, or full-deferral tiers by whether the one-sided 95% Wilson lower confidence bound of pass rate among accepted cases meets the 95% clinical target line. Across 1,605 MIRA-v2, CDM, VivaBench, and in-hospital liver malignancy primary cohort cases, MIRA-v2 single-run top-50% pass rate reached 98.91%, matching five-run consistency, saving ~80% compute; CDM achieved 96.00% test attainment by escalating to the five-run consistency tier; cross-specialty, missing-imaging, and combined enriched cohorts entered the full-deferral tier, capping calibration false-certification rate at 0.00%-3.50%.

0.25

Asclepius: An Adaptive Harness for Long-Horizon Clinical Agents

cs.AI ·2026-09-11 ·Grace Chang Yuan, Xiaoman Zhang, Sung Eun Kim, Luyang Luo, Pranav Rajpurkar
top venue similarity 0.64
Abstract · 9 pages, 4 figures, 11 tables. EMNLP 2026 Findings

LLM agents are predominantly benchmarked on short, single-task trajectories, yet real deployments run for hours under contention, surfacing a different class of failures. We use the Clinical Environment Simulator (CES), in which an agent manages an entire emergency-department shift under continuous time and resource pressure, as a testbed: long-horizon execution failures manifest measurably in a single rollout under structured, multi-dimensional grading. On CES, current agents reach the correct diagnosis in most cases yet fail to deliver complete and timely critical actions, revealing an execution gap. We attribute this gap to three long-horizon failure modes, each operationalized as a per-trace counter: instruction-adherence drift, treatment incompleteness, and a severity-equity gap in timeliness. We then introduce Asclepius, an adaptive agent scaffolding with a self-evolving harness that rewrites the operating manual between shifts from trace-level feedback, an externalized clinical skills library for high-stakes regimen knowledge, and three isolated subagents that partition per-turn decisions across the patient queue. On held-out batches never observed during harness evolution, Asclepius improves critical-action correctness by 22% (p = 0.024) over a strong baseline agent framework while preserving diagnostic accuracy, with consistent gains across five LLM judges from three model families; on the full ten-batch set, improvements reach 25% on critical actions and 13% on timeliness. The three failure modes form a coupled bottleneck: decisive reductions appear only when all three components act together.

0.63

Right Diagnosis, Unsafe Route: Auditing Clinical AI Decision Trajectories and Corrective Oversight for Validity and Potential Harm

cs.AI ·2026-11-17 ·Guanqiao Chen, Wei Jiang, Shu Zhang, Qian Lin, Guanxu Yu +3 more
benchmarkcode/data similarity 0.62
Abstract

A clinical AI system can reach a correct final diagnosis through intermediate decisions that could have harmed the patient, and can repair an error while introducing new risks. Most evaluations score final diagnoses; even stepwise benchmarks, which release a case's evidence over time, score whether systems reach the right diagnosis or gather the right information, not whether the decisions a patient passes through are safe. We make patient safety the target of stepwise evaluation. A trajectory audit replays real admissions checkpoint by checkpoint, lets each system decide with only the evidence released so far, and rates every test, treatment and disposition for its potential harm to the patient and, separately, for clinical validity, against the documented final diagnosis and physician-written disease rubrics yet on the evidence available when the decision was made. An LLM judge scores every decision, and a physician reference standard (triple annotation and senior adjudication of a stratified sample) calibrates the rates. An oversight audit branches each trajectory at its first actionable error and measures, on the same branches, whether corrective feedback repairs the error and whether it introduces new harm. Across 300 cases from a hospital cardiology cohort, MIMIC-IV and the public ASCENT benchmark, with up to seven AI systems per source, 55.2% of hospital trajectories reaching an acceptable final diagnosis passed through a decision with moderate or severe potential harm and 24.8% through a clinically unacceptable one; the harm rates were 76.2% on MIMIC-IV and 39.6% on ASCENT. Structured corrections resolved 73.6% of first errors versus 24.8% after bare rejection, yet new potentially unsafe decisions followed 30.2% of corrections versus 19.7% of rejections. A correct final diagnosis does not certify a safe trajectory, and a successful correction does not certify a safe recovery.

0.37

Fixing a Model That Learned Worse Cancer Means Lower Risk: Monotonic Constraints in Bladder Cancer Recurrence Prediction

cs.LG ·2026-10-01 ·Saram Abbas, David Thomas, Naeem Soomro, Rishad Shafik, Rakesh Heer +1 more
similarity 0.61
Abstract · 13 pages, 4 figures, 1 table. Supplementary material (15 pages) provided as ancillary files

Background and Objective: Clinicians expect recurrence risk to climb with cancer severity. In a UK multicentre trial, an unconstrained XGBoost model learnt that higher tumour stage and carcinoma in situ predicted lower recurrence risk, and discrimination, calibration, and SHAP were all blind to it. We developed a counterfactual testing framework to detect this inversion and a monotonic-constraint framework to remove it without hurting performance. Methods: BOXIT enrolled 472 patients with protocol-mandated cystoscopy across 51 UK sites (2007-2012); 435 had at least two years' follow-up (153 recurrences, 35.2%). We developed a counterfactual direction test and a monotonic-constraint correction, with constraint directions drawn from the EORTC and EAU risk systems, and evaluated both against unconstrained XGBoost and logistic regression on 18 predictors (seven directed) over 50 cross-validation folds. The test worsened each patient on one directed feature at a time to check whether risk fell; SHAP direction and calibration were also assessed. Key Findings and Limitations: Tumour stage and carcinoma in situ were associated with lower recurrence, opposite to medical intuition; the unconstrained model reversed carcinoma in situ counterfactuals in 90.2% of cases and stage in 74.3%. Discrimination ($Δ$AUC 0.005, p=0.47), calibration, and SHAP magnitude were all blind to the inversion. Monotonic constraints eliminated every violation at no cost to discrimination (0.723 vs 0.718) and outperformed EORTC (p=8.9e-16). Limitations: single trial, internal-external validation only. Conclusions and Clinical Implications: A model that had learned this inversion passed every conventional check. A counterfactual direction test, run as a single refit with pre-specified monotonic constraints, catches this failure at no cost to performance and should be routine before clinical deployment.

0.49

Beyond Uncertainty Reduction: Calibrated Planning for Interactive Diagnosis

cs.AI ·2026-08-28 ·Yue Zhou, Haiyang Zhou, Jin Zhang, Kong Wang, Zihao Rao +3 more
code/data similarity 0.60
Abstract

Interactive medical diagnosis requires an agent to gather patient evidence through sequential questions before committing to a diagnosis. Large language models (LLMs) now make such consultations feasible, and existing approaches typically select questions by how much they reduce uncertainty among candidate diseases. However, this objective is insensitive to the unequal clinical costs of diagnostic errors and omitted severe alternatives, so minimizing uncertainty need not minimize final diagnostic loss. To bridge this gap, we propose CaRDI (Calibrated Risk for Diagnostic Interaction), a planning framework built around a clinical loss combining primary diagnosis error with severity-weighted differential omission. Diagnostic and safety beliefs estimate the two loss components, while conformal residual calibration corrects for underestimation from partial evidence. The calibrated risk then guides question selection and stopping by balancing expected risk reduction against interaction cost. Experiments on multiple medical benchmarks show that CaRDI improves accuracy while requiring fewer questions. Further analysis shows that replacing entropy with clinical risk as the planning objective reduces clinical loss by 21.5% and decreases severe omissions. Our code is available at https://anonymous.4open.science/r/CaRDI-A940/.

0.28

Scalable Evaluation of Medical AI using Evidence-based Practice Recommendations

cs.AI cs.HC ·2026-11-20 ·Teya Bergamaschi, Bijal Rajput, Akshay Goel, Matthew Thompson, Jacqueline Shreibati +12 more
similarity 0.60
Abstract

Rigorously evaluating medical artificial intelligence (AI) requires testing open-ended clinical management across diverse presentations and stages of care. However, existing benchmarks rely on manual expert authoring, limiting coverage across conditions, conditional care pathways, and evolving guidelines. We develop an automated pipeline that extracts and verifies structured clinical criteria and branching decision trees from practice recommendations to generate scenarios spanning the care continuum, including nuanced presentations and practice variations across regions and guideline editions. Applied to 436 BMJ Best Practice clinical monographs (354 US, 82 International), this yields 3,200 scenarios spanning differential diagnosis, investigations, treatment, and complications, plus targeted suites for regional specificity (731 US/International pairs) and temporal freshness (630 scenarios). To grade responses, we develop a clinician-calibrated autorater that scores management plans on a 4-point rubric stratifying deviations by clinical severity. Across Gemini models, scaling improves adherence, while web search (+0.8 percentage points [pp] on average) and multi-sample synthesis (+2.2 pp) combine additively (+2.8 pp). In context, full monographs consistently trail condensed excerpts. On targeted suites, web search narrows international performance gaps (+4.2 pp) and improves adherence to newly updated guidance (+4.6 pp). In a study with Primary Care Physicians (n = 9) across 200 scenarios, AI assistance raises adherence from 50.5% to 70.0%, driven largely by fewer clinical omissions. Overall, our results demonstrate a scalable evaluation setup using an evidence-based corpus originally written to guide human clinical decision-making, and demonstrate its viability to assess medical AI and its assistance on clinician decision-making.

0.13

When to Trust Simulated Patient Responses:Support-Gated World Models for Vasopressor Decision Support

cs.AI ·2026-11-13 ·Yifan Jin, Tao Liu
similarity 0.60
Abstract

Clinical world models expose language-model agents to predicted patient responses, but simulations can be unreliable for poorly supported treatments or unfamiliar hospitals. We introduce Support-Gated World-Model decision support, a lightweight extension of a propose--simulate--refine agent. A recurrent dynamics ensemble predicts short-horizon physiological responses to documented norepinephrine dose categories, while a behavior model estimates observational action support. The interface withholds predictions with insufficient support or excessive ensemble disagreement and abstains when no candidate qualifies. Evaluation on eICU-CRD includes 70 hospitals and 30,700 decision transitions, with 14 hospitals held out for testing. At 62.0% factual-transition coverage, joint gating yields a MAP mean absolute error of 7.3 mmHg, compared with 9.2 mmHg for random selection at the same coverage. The gated agent achieves 60.0% agreement with recorded actions at 81.0% decision coverage, compared with 55.0% agreement and 99.5% coverage for an ungated ensemble agent. Component ablations show lower factual risk with joint gating than with either gate alone.These results characterize a reliability--coverage trade-off in selective clinical simulation; they do not identify individualized treatment effects or establish improved patient outcomes.

0.15

Testing-Driven Reliability Audit of Trajectory-Based Early Outcome Prediction for LLM Agents: Target-Specific Calibration Transfer Persists Within a Single Benchmark

cs.AI ·2026-09-22 ·YanZe Cao
benchmark similarity 0.60
Abstract · 26 pages, 4 figures, 3 tables

Predicting early outcomes based on trajectory can decrease the expenses associated with agent evaluation by terminating a run once the outcome becomes sufficiently predictable, assuming that the predictor's confidence is properly calibrated. Calibration is at risk when a predictor is applied to an agent on which it was never trained, but it is not known whether such transfer failures are broad across agent systems or concentrated in specific target agent/head combinations. Using public SWE-bench Verified trajectories and a frozen dual-head early-outcome prediction pipeline, we ran a leave-one-agent-out calibration audit, a shared-predictor leave-two-agents-out control, oracle prior correction, and a robustness battery over training cohorts, task resampling, task halves, jackknife, and thresholds. Fixed-scaffold TerminalBench analysis served as a pre-registered boundary test. Broad same-predictor pairwise heterogeneity was not supported; the median pairwise corrected-gap differences were 0.0180 (SUCCESS head, 45 pairs) and 0.0385 (FAILURE head, 35 pairs), and the pre-registered heterogeneity criterion was not met on either head. Two specific combinations, gpt-5-mini/SUCCESS and claude-opus-4.6/FAILURE, showed persistent calibration-transfer errors (median corrected gaps 0.1377 and 0.1107) without a sign reversal under any frozen control. TerminalBench did not establish cross-benchmark replication: the success target produced zero decisions (INDETERMINATE), and the failure target did not satisfy the pre-registered persistence criterion. Therefore, a strong target-specific calibration-transfer error can exist within one frozen environment, but the evidence does not establish that the error is intrinsic to the model or general across benchmarks.

0.52