CS Paper Radar

AnyBodyCodec: A Shared Native Interface for Body-Model Conversion, Extension, and Humanoid Control

Qianxing Li

cs.RO ·submitted 2026-11-20 10:03 UTC · v1

Abstract

Parametric body models expose incompatible pose and shape controls, tying humanoid policies to particular input formats. AnyBodyCodec learns a shared representation through native conversion, then reuses it for new body models and control with its core frozen. Encoders map MHR, SMPL-X, and SOMA to aligned slots; native decoders recover target controls. The 1.090M-parameter converter covers nine routes and reaches 16.801 mm input-reference MPJPE across six cross routes: the 2.887M Transformer bank reaches 16.390 mm and its parameter-matched version 18.866 mm. Three measured routes take 7.43-7.67 ms on an RTX 4090. Adding ANNY shows that comparable conversion accuracy can accompany different action consistency under one frozen controller. Under a matched PPO budget, aligned slots support 60.78% full-action success across three formats. Separate 160-hour training reaches 66.10% source-weighted validation success, and the controller is deployed qualitatively on a physical G1 through three visual front ends. Together, these results establish reuse through both native geometric fidelity and downstream policy compatibility.

Closest papers

Nearest neighbours by meaning across the whole index.

Fast and Accurate Body Estimation in Pixels, World Space and Scenes

cs.CV cs.RO ·2026-11-19 ·Jinkun Cao
code/data similarity 0.59
Abstract · 28 pages, 9 pages of main text. 16 figures

We present FAB (Fast and Accurate Body estimation), a human body estimator that jointly improves inference efficiency and body-recovery fidelity. Rather than predicting only parametric mesh-model parameters, FAB directly predicts human skeleton joints and dense surface points. In images, it predicts dense 2D and 3D body points alongside a parametric Momentum Human Rig (MHR) head, then fits SMPL in one learned pass followed by two Gauss-Newton steps. Its ViT-L student, FAB-L, distilled from a fine-tuned SAM 3D Body, runs in real time for one person on an RTX 4070 Ti SUPER, from detection to a fitted body, at 4.6x the speed of SAM 3D Body's eager-PyTorch body-only path, while improving accuracy on most camera-space benchmarks. The same network predicts heel, toe, hand, and knee contacts, which connect the body to the scene. FAB also estimates world-space motion, fuses static-scene depth around the visible person, and aligns body and scene using predicted contacts. For human-to-humanoid real-to-sim transfer, an in-model G1 head and FAB-Retarget, a motion-level retargeter that reads dense points or the fitted mesh, map motion to a Unitree G1. FAB-Retarget produces references that follow the person more closely than specialized retargeters including SOMA, GMR, UMR, and OmniRetarget, and substantially more closely than Fast SAM 3D Body retargeted with our sequence IK. Project page: https://www.jinkuncao.com/FAB.

0.27

CADENCE:Temporally Coherent Whole-Body Human Mesh Recovery that Preserves Expressive Hand Motion

cs.CV cs.GRcs.LG ·2026-11-19 ·Keniel Peart, Jagmohan Chauhan, Indu P. Bodala, Shelly Vishwakarma
similarity 0.59
Abstract

Whole-body SMPL-X estimators recover body, hand, and face meshes from single images, but applied frame by frame to video they produce jittery motion. Smoothing the output removes the jitter at a cost that body-only benchmarks do not measure: a temporal filter strong enough to steady the torso also flattens the fast finger strokes that carry meaning in sign language and gesture. We present CADENCE, a whole-body SMPL-X system for monocular video designed around this trade-off. A per-frame estimator built on a shared C-RADIOv4 encoder, with a high-resolution hand pathway that reuses the same encoder on hand crops, produces each frame's estimate. An offline temporal refiner then filters the SMPL-X rotation sequence: attention along the kinematic tree selects, for every joint and every frame, a mixture of learned zero-phase filters, so the torso is smoothed while fast finger strokes pass through. On 3DPW, the refiner reduces acceleration error from 17.4 to 5.4 mm/s2 while lowering PA-MPJPE from 41.9 to 40.2 mm; generic smoothers applied to the same predictions reach 6.2 to 7.7 mm/s2. On SignAvatars/How2Sign sign-language sequences, the refiner has the lowest hand jitter among the compared smoothers while keeping a hand-speed peak amplitude of 0.98, against 0.35 for a SmoothNet retrained on the full SMPL-X vector. The per-frame estimator also obtains the lowest full-body mesh error (25.7 mm) and hand joint error (8.3 mm) among the compared methods on EHF.

0.24

OmniCalib: Target-Free, Task-Structured Self-Calibration for Humanoid Robots

cs.RO ·2026-09-17 ·Kaixiang Lu, Haiyu Lan, Chunxiao Qiao, You Li, Enyu Li +4 more
similarity 0.57
Abstract · 6 figures, 3 tables

Assembly, wear, and component replacement perturb the sensor extrinsics and joint zeros encoded by a humanoid CAD model. Existing procedures calibrate one sensor pair or require external fiducials. Using only robot-native motion and onboard sensing, we present OmniCalib, a target-free workflow that calibrates the full upper limbs---all 14 arm joint zeros and the extrinsics of both wrist and chest cameras---as well as lower limbs and the multi-camera head rig. Each module matches a robot-native task to a parameter block, checks observability, and writes only supported corrections to the CAD model. Our depth ICP method recovers all 14 arm joint zeros and calibrates all RGB-D camera extrinsics without any calibration target. Relative to CAD, the estimated extrinsic corrections are 10.56 mm and 1.74 degrees for the left wrist, 6.33 mm and 1.25 degrees for the right wrist, and 9.81 mm and 0.929 degrees for the chest RGB-D camera. ICP point-to-plane residual is 2.09 mm. On the same injected offsets, ICP and ArUco recover all 14 joint zeros below the 0.1-degree encoder-resolution reference. On an AGIBOT A3 Ultra humanoid, four static double-support stances recover all 12 lower-limb joint-zero offsets injected with an RMS error of 0.063 degrees. The head module combines multi-camera visual odometry with legged odometry and dynamic compensation through the live ROS transform tree. Using only planar walking, it attains a mean SO(3) error of 1.061 degrees across three sequences. The best sequence reaches 0.775 degrees, competitive with iKalibr at 0.902 degrees from rich 6-DOF excitation. Rig-relative angles repeat within 0.140 degrees. Injection recovery and held-out tests validate each observable block.

0.25

S2HAND: Accuracy-Preservation Trade-Offs for Hand Specialization in Whole-Body Pose Models

cs.CV ·2026-11-07 ·Singyu Muk, Xuanren Song, Kalin Stefanov
code/data similarity 0.56
Abstract · 39 pages, including appendices. Code and models: https://github.com/ronggong000/S2HAND

Unified whole-body pose estimators jointly predict body, face, and hand landmarks, but often degrade on small, blurred, or occluded hands. Attaching a standalone hand specialist introduces extra detection overhead, coordinate alignment, and wrist-stitching artifacts. We introduce S2HAND, a hand-specialized Sapiens2-5B framework that preserves the native 308-keypoint output interface. Specifically, S2HAND-MT adapts a lightweight 0.87M-parameter pose branch to route 40 finger heatmaps while strictly preserving the shared Transformer, auxiliary task heads, and the other 268 body, foot, and face heatmaps. S2HAND-Pose further fine-tunes three Fisher-selected Transformer blocks (267.13M parameters), trading exact preservation for stronger hand recovery: it lifts macro AUC from 57.83% to 65.73% across HInt TEST, COCO WholeBody VAL, and FreiHAND EVAL, and surpasses HInt-adapted Hand5/HRNet and stitched Hand5 systems on all five Native Pipeline benchmarks. On COCO, S2HAND-Pose improves hand AP by 12.89 points and body-plus-foot AP by 0.19 points. Across a 512-image multi-task audit, it maintains 99.60% foreground segmentation agreement with the public checkpoint, with quantified normal and pointmap drift. Its 2D coordinates also lower 3D mesh error in frozen Pose2Mesh transfer, while our optional TailGuard re-cropping module cuts S2HAND-MT's severe failure rate on NewDays from 13.45% to 10.43%. S2HAND thus resolves the whole-body hand bottleneck with either exact non-hand preservation (MT) or empirically audited trade-offs (Pose).

0.33

OneSteer: Unlocking Steerable General Humanoid Motion Tracking via One-Step Diffusion Whole-Body Control

cs.RO ·2026-10-30 ·Yifei Huang, Yazhao Yang, Weijia Li, Zhiheng Ma, Dian Shen
similarity 0.55
Abstract

Deployment objectives often specify desired outcomes without providing revised trajectories, while parts of the original reference must still be followed. We present OneSteer, a one-step diffusion whole-body controller that combines general motion tracking with selective test-time steering. To accommodate new objectives, differentiable task costs guide optimization of the generator's input noise with frozen weights, while body-group reference masks relax selected tracking requirements. Predicted state-action plans provide a shared interface for task optimization and feedback-conditioned execution. For nominal tracking, the model trained from scratch achieves the lowest local tracking error among the evaluated baselines on successful held-out AMASS and BONES clips. For steering, one frozen distilled controller adapts across diverse deployment objectives in simulation, raising the clean passage rate under a 1.25 m bar from 2% to 90%. On a physical Unitree G1, OneSteer completes all 27 nominal tracking trials across nine diverse whole-body motion sequences without falling. With a steering cost derived from a signed distance field built using only onboard LiDAR, it also passes under a 1.1 m low bar in four of five attempts and steps over a 12 cm hurdle without falling in all three attempts. Beyond control, prediction variation in the model trained from scratch ranks likely tracking failures without physics rollouts. This scoring method is more than 10x faster than simulation-based scoring with five rollouts per clip and guides targeted fine-tuning.

0.12

PhysMamba: Selective State Space Models as Learned Articulated Body Simulators

cs.CV ·2026-10-02 ·Haochuan Zhang, Sinisa Todorovic
published similarity 0.54
Abstract · CVPR 2026 Workshop on Physically Grounded Human Perception and Modeling -- 1st PhysHuman

We introduce the first learned articulated body simulator based on a selective state space model (SSM), called PhysMamba. PhysMamba predicts next-frame full-body state from position, rotation, and joint-action history, without velocity inputs. We compare four architectures under partial- and full-observation inputs and three training protocols. The from-scratch rollout training protocol gives Mamba2 strong short- and mid-horizon accuracy under partial observation (s10 = 43 mm, 2/50 diverged), while the two-stage teacher-based rollout protocol stabilizes GRU but fails for Mamba2. With CUDA graph compilation, Mamba2 reaches 0.107 ms per frame (9,334 FPS) on an H100 GPU, within 1.1$\times$ of GRU's un-compiled throughput, adding under 1% latency to a 30 Hz HMR pipeline and enabling integration as a differentiable physics module for video-based mesh recovery.

0.40

Anchor 1: Precise and Stable Humanoid Control for Whole-Body Manipulation

cs.RO ·2026-10-30 ·Archon Robotics, :, Caojun Wang, Checheng Yu, Gangcheng Jiang +22 more
benchmark similarity 0.54
Abstract

Humanoid controllers have acquired increasingly diverse motor skills, yet translating these capabilities into precise and stable whole-body manipulation remains challenging. Manipulation tasks are sensitive to execution deviations -- even small errors or unintended steps can cause failure. Introducing Anchor 1, a whole-body controller for precise and stable whole-body manipulation, together with a benchmark spanning diverse coordination demands. Anchor 1 adopts calibrated sparse motion references to preserve task-relevant human motion structure without online joint-space retargeting, leaving kinematic freedom for precise control. To guide this freedom towards stable, physically plausible whole-body coordination, we shape the training distribution through offline curation of robot motions paired with these calibrated sparse references. We further introduce explicit error feedback decoupled from motion encoding, improving control precision while supporting flexible command interfaces. To achieve a systematic evaluation of these capabilities, a benchmark is proposed to assess precision, sustained execution stability, and reachability across diverse whole-body coordination demands. Evaluations in simulation and on hardware show stronger precision and stability across all evaluation tracks. Under the most strict real-world global scoring setting, Anchor 1 achieves a 30\% to 80\% decrease in tracking error with fewer look-ahead inputs, and without retargeting compared to all existing controllers. Downstream experiments demonstrate more efficient teleoperated data collection and higher task success using the same deployment pipeline as well. We believe Anchor 1 supports precise and stable whole-body control as a practical basis for humanoid task execution.

0.18

Dataset-Free Compliant Humanoid Loco-Manipulation with Dynamic Online Posture

cs.RO ·2026-10-05 ·Seungho Yeom, Zhenyu Wu, Jaeyoung Huh, Diego Williams, Yuheng Zhi +2 more
similarity 0.54
Abstract

Most humanoid loco-manipulation controllers require human motion data to learn whole-body coordination and posture, leaving policies reliant on external sources to provide this data. We present OCLO (Online-posture Compliant LOco-manipulation), a humanoid loco-manipulation system trained without human motion data and commanded only through two end-effector targets. Because these targets do not uniquely determine whole-body posture, OCLO generates pelvis height and torso orientation online using an analytic reachability prior, further refined through policy-in-the-loop sampling with a task-agnostic cost. OCLO also learns whole-body compliance by displacing end-effector references according to measured forces through a spring-damper model, encouraging the legs, waist, and pelvis to yield to external loads. In simulation, using the reachability prior leads to a 77.8% success rate in acquiring the commanded reference, a vast improvement over the 37.8% success rate accomplished without the prior. Further, refinement reduces end-effector orientation error across all evaluated tasks. The same posture module improves a pretrained SONIC controller on four of five tasks. Without compliance training, policies tend to lose balance under disturbances rather than sacrifice tracking. On a Unitree G1, OCLO maintains balance under end-effector disturbances that cause its ablations to fail and performs seven loco-manipulation tasks, including crouched walking and picking up a box from a low surface. Project website: https://oclo-humanoid.github.io/

0.27