CS Paper Radar

Augmentation of cardiovascular flow measurements with generative diffusion models

Fabio Guglietta, Tianyi Li, Francesco Viola, Luca Biferale

cs.CV physics.flu-dyn ·submitted 2026-11-20 17:52 UTC · v1

Abstract

Cardiovascular imaging offers several ways to measure blood flow, but each provides an incomplete, resolution-limited, or noisy view of the underlying dynamics. Reconstructing the missing information is inherently ambiguous because several flow fields may be compatible with the same observation. Here, we investigate generative diffusion models as tools for cardiovascular-flow generation and reconstruction using a fully controlled state-of-the-art dataset from a digital twin of a healthy human left heart. First, we show how unconditional samples reproduce the changing anatomy and the highly fluctuating statistical properties of the flow throughout the cardiac cycle. Second, we test the conditional inference of our generative model by reconstructing an entire 2D planar section of geometry and flow configurations from a limited portion. Repeated reconstructions allow us to represent a range of plausible completions, going beyond a single deterministic estimate, while their mean retains the principal features of the reference flow. Comparison with a Gaussian process regression baseline on the same reduced domain highlights the main advantage of diffusion models: their reconstructed ensembles capture a broader range of velocity and gradient fluctuations, better encompassing ground-truth features that the baseline distributions can miss. Our results provide a quantitative proof of concept for probabilistic reconstruction of incomplete cardiovascular-flow measurements and demonstrate the potential for groundbreaking applications to the augmentation of in-vivo cardiovascular imaging data.

Closest papers

Nearest neighbours by meaning across the whole index.

Flow-based conditional cardiac anatomy generation for virtual cohorts

cs.LG cs.CVq-bio.QMq-bio.TO ·2026-08-10 ·Konstantinos Kevopoulos, Beatrice Moscoloni, Benjamin Alheit, Cameron Beeche, Julio A. Chirinos +2 more
similarity 0.70
Abstract

Cardiac digital twin research is moving from subject-specific anatomical replicas toward virtual cohorts that represent clinically relevant population subgroups. Yet access to representative imaging-derived anatomy datasets remains limited by cohort size, subgroup sparsity, and data-sharing constraints. Conditional generative models could help address this gap, but virtual cohorts are useful only if they preserve realistic, metadata-dependent anatomical variability. Existing cardiac anatomy generators largely rely on conditional variational autoencoders (cVAEs), which couple representation learning and metadata conditioning through a shared regularized latent prior. We introduce CAN-FLOW, a two-step Conditional ANatomy generation framework based on normalizing FLOWs that first learns geometry-only latent representations of diffeomorphic cardiac shape momenta and then models their sex-, age-, and body-mass-index-dependent distribution with a conditional normalizing flow. We trained CAN-FLOW on 2,208 healthy UK Biobank subjects and compared it with cVAEs across regularization strengths. CAN-FLOW generated plausible stochastic biventricular anatomies that better reproduced clinical phenotype distributions, metadata-dependent trends, subgroup variability, point-cloud coverage, and high-dimensional shape variability. Together, these results establish CAN-FLOW as a shareable framework for generating realistic, stochastically varying, metadata-conditioned biventricular anatomies for virtual cohort construction and in silico clinical trial workflows.

0.04

Physics-Guided Flow Matching for CT Image Reconstruction

cs.AI cs.CV ·2026-08-28 ·Davide Evangelista
similarity 0.70
Abstract · 16 pages, 6 figures, 2 tables

Deep generative models have recently emerged as powerful priors for solving ill-posed inverse problems in CT, with diffusion-based approaches achieving state-of-the-art reconstruction performance. However, diffusion models typically rely on stochastic sampling procedures, long inference trajectories, and carefully tuned noise schedules, which can limit computational efficiency and numerical stability, especially at high spatial resolutions. In this work, we investigate Flow Matching as an alternative generative prior for CT reconstruction. We train a high-resolution Rectified Flow Matching model on 256x256 chest images from the Mayo Clinic Low-Dose CT dataset. To mitigate overfitting and limited anatomical variability, we employ a two-stage training strategy consisting of an initial phase with strong, anatomically informed data augmentation, followed by a fine-tuning phase with reduced or no augmentation to refine structural fidelity. The resulting model is capable of generating high-quality and anatomically coherent CT-like images, serving as a strong learned prior. We then evaluate multiple reconstruction methods specifically designed for Flow Matching models, including Plug-and-Play Flow, FlowDPS, Flower, and Flow-Priors (ICTM), and compare them against state-of-the-art diffusion-based reconstruction algorithms such as DDRM, DPS, and DiffPIR. Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps. Finally, we publicly release the trained Flow Matching model and accompanying code to facilitate reproducibility and future research. Overall, this work demonstrates that Flow Matching provides a stable, efficient, and effective alternative to diffusion models for high-resolution CT image reconstruction.

0.41

GenStrain: Multi-Conditional Generative Diffusion Model To Synthesize High-quality Motion and Strain Maps From Cardiac Magnetic Resonance Images

eess.IV cs.LG ·2026-11-05 ·Rishov Paul, Sona Ghadimi, Cristiane C. Singulane, Amit R. Patel, Frederick H. Epstein +1 more
code/data similarity 0.69
Abstract

This paper presents GenStrain, a novel method for synthesizing high-quality cardiac motion-based strain maps from routinely collected cine cardiac magnetic resonance (CMR) images. Existing approaches typically rely on image registration to estimate motion (a sequence of displacements) from cine CMR images, but cine CMR presents very sparse trackable intramyocardial features, presenting challenges to estimate intramyocardial motion. An advanced imaging technique, Displacement Encoding with Stimulated Echoes (DENSE) CMR, is considered as the gold standard for strain assessment, but it requires additional acquisitions, which are not ideal for efficient clinical workflows. To address this gap, we introduce GenStrain, a novel framework designed to learn the data distribution of highly accurate cardiac motion captured by DENSE. In particular, we develop a diffusion process in motion space, where spatiotemporal continuity is carefully considered. To fully leverage both cine CMR images and their associated motion patterns, we introduce a multi-conditional conditioning strategy that integrates anatomical features and motion representations learned by a spatiotemporal registration model to guide the generation process. Experimental results demonstrate that our proposed model, GenStrain, outperforms existing strain analysis methods based on displacement estimates from both traditional registration approaches and state-of-the-art (SOTA) deep learning models. Our model represents a promising step toward more accurate cardiac function assessment and holds great potential for clinical translation. Our code is publicly available at https://github.com/Rishov-MIA/GenStrain.

0.14

Reconstruction of 4D Mitral Regurgitation Hemodynamics from Sparse Planar Data using Deep Operator Networks with Test-Time Adaptation

cs.LG physics.med-phphysics.flu-dyn ·2026-08-31 ·Jakob Marcel Hoffmann, Yosuke Hasegawa, Alexander Stroh
similarity 0.67
Abstract

Quantifying mitral regurgitation severity remains limited by the assumptions of clinical flow convergence methods, while high-fidelity simulation and volumetric velocimetry are too slow for routine use. We investigate whether a learned solution operator can reconstruct transient three-dimensional transvalvular hemodynamics from the sparse observation an in-vitro experiment actually provides: a single planar velocity slice and two boundary pressure traces. A Deep Operator Network is pretrained on an experimentally benchmarked URANS database spanning eleven mitral regurgitation orifice phantoms, learning a mapping from a masked two-component planar velocity snapshot to the surrounding volumetric field, and is subsequently adapted to unseen target cases by fine-tuning on their sparse measurements. Adaptation reliably corrects the flow topology within the supervised plane, reorienting a strongly eccentric jet that the pretrained operator predicts as straight, and yields full-field predictions in minutes rather than the days required by the underlying simulations. Its influence decays sharply with distance from that plane, however: measured against phase-resolved particle image velocimetry, the reconstruction error rises from 24.6% at 2mm to 52.6% at 6mm, and the resulting mismatch between corrected and uncorrected layers degrades physical consistency. Single-plane supervision thus constrains the observed plane far more effectively than the surrounding volume, which we identify as the principal obstacle to coherent 4D reconstruction from sparse planar data.

0.18

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.66
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.13

Spatial and Temporal Super-Resolution and Denoising of Intracardiac 4D Flow MRI

cs.CV ·2026-11-02 ·Yusuf A. Ozturk, Jie Zheng, Fanwei Kong
similarity 0.66
Abstract

Intracardiac flow is driven by complex, and time-varying cardiac motion and interaction with the heart valves, producing complex flow features that may provide valuable information for disease diagnosis and treatment planning. 4D Flow MRI enables non-invasive, time-resolved measurement of three-dimensional cardiovascular velocity fields. However, substantial noise and limited spatial and temporal resolution limit its ability to accurately resolve flow features. We propose 4D-MRAR (4D Magnetic Resonance Augmented Reconstruction), a deep learning (DL) method to super-resolve and denoise 4D Flow MRI data. Unlike prior DL methods that train and infer on static vascular regions, our method predicts intracardiac flow within hearts undergoing large deformation. Moreover, it uniquely allows for simultaneous super-resolution in 3D space and time. The method combines a residual convolutional neural network, a recurrent neural network, and an implicit neural field to predict high-resolution velocity and pressure fields while efficiently enforcing the governing equations of fluid flow during training. Trained on a synthetic dataset obtained from computational fluid dynamics (CFD) simulations of left ventricle (LV) flow, our method generalizes to synthetic whole-heart 4D flow MRI data, and demonstrated promising performance on real 4D Flow MRI. The produced super-resolved flow fields exhibit significantly improved accuracy and greater consistency with the governing equations of blood flow compared with prior methods.

0.04

Learning Incompressible 3D Flows from Sparse Samples: A Set Transformer Approach to Divergence-Free Kernel Fitting

cs.LG cs.AIcs.CE ·2026-10-12 ·Ramzi Idoughi, Radouan Boukharfane, Peter Wonka
similarity 0.65
Abstract · 33 pages with supplement materials, 9 figures

Recovering divergence-free velocity fields from sparse and corrupted observations requires reconciling physical consistency, expressive representations, and robustness to missing data. We introduce DFK-Former, a set-to-field transformer that reconstructs divergence-free velocity fields from sparse, noisy, and irregularly sampled 3D observations. The model is inherently invariant to the number and ordering of input samples and predicts the parameters of a divergence-free kernel representation, producing continuous, mesh-free velocity fields that satisfy incompressibility exactly by construction rather than approximately through soft constraints or projection operators. Unlike existing divergence-free kernel approaches, which estimate kernel coefficients via a separate optimization for each field, DFK-Former predicts these coefficients directly in a single forward pass. This eliminates costly iterative fitting while providing a learned prior that enables accurate reconstruction even when observations are insufficient to uniquely determine the field. To enhance representational power, we introduce adaptive and anisotropic divergence-free kernels that preserve exact incompressibility guarantees while capturing more complex flow structures. Extensive experiments across varying levels of sparsity, noise, and occlusion, including transfer to real Direct Numerical Simulation (DNS) turbulence data, demonstrate substantial gains in both accuracy and efficiency. DFK-Former reduces endpoint error by up to 4.6x compared to per-field divergence-free-kernel optimization, while reconstructing each field in 7.5 ms instead of 9.8 s, yielding a speedup of more than three orders of magnitude. These results establish direct, feed-forward prediction of divergence-free kernel parameters as a practical and effective paradigm for physically consistent velocity-field reconstruction from sparse observations.

0.22

Learning to Beat: Phenotype-Guided Latent Flow with Regional Motion Priors for Biventricular Motion Synthesis

cs.CV cs.AI ·2026-08-20 ·Xuan Yang, Xiaohan Yuan, Hao Li, Lingyu Chen, Yanan Liu +2 more
similarity 0.65
Abstract · 14pages, 10 figures

Full-cycle biventricular geometry is essential for characterizing cardiac function. However, dense and temporally consistent 3D+t biventricular meshes are not routinely available, whereas end-diastolic (ED) anatomy can often be obtained reliably. We therefore investigate full-cycle biventricular motion synthesis from a single ED mesh. This task is challenging because cardiac deformation is spatially heterogeneous and phenotype dependent, while conventional global generative models often obscure localized motion patterns. In this study, we propose a region-specific and phenotype-adaptive framework that integrates motion-informed functional parcellation with conditional latent flow. A functional partition learned from reconstructed motion organizes the ventricular surface into regions with coherent dynamics and enables topology-aware regional feature exchange. A phenotype-conditioned rectified-flow model subsequently maps the ED anatomy to full-cycle motion latents through fine-grained conditioning and prototype-routed motion adapters. An optional control branch further incorporates available motion descriptors for controllable synthesis. Experiments on ACDC, M\&Ms, and M\&Ms-2 demonstrate consistent improvements in geometric accuracy and functional fidelity. Under ED-only synthesis, our method achieves biventricular ASSD, HD95, and vRMSE of \(1.49\pm0.34\)~mm, \(3.77\pm1.06\)~mm, and \(3.31\pm1.03\)~mm, respectively, outperforming all competing methods. Complementary functional and robustness evaluations further demonstrate that the synthesized sequences preserve physiologically plausible ventricular dynamics and generalize across cohorts and disease phenotypes. The code will be released publicly upon acceptance of the manuscript for publication.

0.27