CS Paper Radar

Beyond Fidelity: Evaluating Synthetic Medical Imaging Data

Seyed Kahaki, Alexander R. Webber, Tahsin Rahman, Elim Thompson, Jana Delfino, Aldo Badano

eess.IV cs.AIcs.CV ·submitted 2026-11-19 19:44 UTC · v1

Abstract

The growing use of synthetic medical imaging datasets (SMD) in the development and evaluation of machine learning models has motivated interest in systematic methods to assess dataset quality across different imaging modalities. Common evaluation strategies rely heavily on fidelity-oriented metrics developed for general computer vision and may not capture clinically relevant properties such as anatomical plausibility, dataset coverage, metadata completeness, subgroup consistency, or documentation quality. We present the ScoreCard Toolkit that operationalizes six of the seven dimensions found within the 7Cs approach for SMD evaluation across Congruence, Coverage, Completeness, Consistency, Constraint, and Comprehension. The ScoreCard Toolkit provides a modular pipeline for preprocessing, feature extraction, metric computation, visualization, and structured scorecard generation. This approach complements standard fidelity-based evaluation by exposing quality characteristics not captured by those measures alone, including constraint violations, anatomically implausible shape artifacts, and metadata-related consistency issues. The toolkit supports appearance, texture, and shape features and is designed to accommodate additional feature representations, including radiomic features, deep-learning embeddings, and foundation-model representations. We demonstrate the end-to-end workflow across three imaging modalities: synthetic digital pathology whole-slide image patch data, synthetic digital mammography, and synthetic head CT. Across all three modalities, the resulting scorecards reveal dataset-specific quality characteristics, such as distributional biases and coverage gaps that may impact their effectiveness for model development or testing. ScoreCard provides a practical, extensible, and modality-agnostic approach for evaluating and transparently reporting SMD quality.

Comment
14 pages

Closest papers

Nearest neighbours by meaning across the whole index.

MedCORE: Criteria-Grounded Clinical Reasoning for Interpretable Medical Image Diagnosis

cs.CV cs.AI ·2026-10-06 ·Asim Khan, Samee Ullah Khan, Dwarikanath Mahapatra
similarity 0.69
Abstract · 16 pages, 4 figures, conference

Clinical diagnosis is inherently a structured reasoning process, yet existing deep learning models often bypass this structure by mapping image features directly to disease labels without explicitly interrogating the morphological and textural criteria that clinicians systematically evaluate. This limits diagnostic transparency and may compromise safe clinical deployment. We present MedCORE (Medical Criteria-Oriented Reasoning and Evidence), a structured diagnostic framework that operationalizes clinical reasoning within a vision-language architecture. For each input image, MedCORE decomposes the diagnostic process into clinically defined criteria, spatially localizes each criterion to diagnostically relevant image regions, encodes evidence through multi-scale representations that capture macro-structural and micro-textural pathological characteristics, and refines criterion representations using a Graph Attention Network that explicitly models inter-criteria dependencies. Criterion representations are further aligned with clinical text descriptors, reinforced through class-wise visual prototypes, and aggregated using uncertainty-calibrated weighting that proportionally discounts low-confidence diagnostic evidence. MedCORE is validated across three clinically heterogeneous imaging modalities, including dermoscopic lesion classification on ISIC 2018, breast ultrasound lesion characterization on BUSI, and diabetic retinopathy grading on IDRiD. Quantitatively, MedCORE achieves 89.2% accuracy, 85.7% macro-F1, and 96.4% AUC on ISIC 2018; 96.1% accuracy, 95.2% macro-F1, and 98.4% AUC on BUSI; and 84.3% accuracy, 80.2% macro-F1, and 92.8% AUC on IDRiD. These results demonstrate consistent improvements over strong CNN, transformer, biomedical vision-language, concept-based, and prototype-based baselines.

0.20

Medical Image Analysis with Machine Learning (MEDiml): Strategies for Simpler Radiomics

eess.IV physics.med-ph ·2026-10-27 ·Mahdi Ait Lhaj Loutfi, Simon Provost, Élodie Gillard, Moustafa Amine Bezzahi, Alexander Chum +11 more
code/data similarity 0.69
Abstract · 11 pages, 3 figures, 2 tables. Software paper. Full reference manual: arXiv:2610.29666 . Software, documentation, tutorials, and resources a…

Radiomics extracts quantitative features describing tumor shape, intensity, and texture from medical images to build models that predict clinical outcomes. However, large feature sets increase the risk of overfitting in small datasets, and building an end-to-end workflow often requires programming expertise. We present MEDiml (Medical Image Analysis with Machine Learning), open-source radiomics software available as a Python package (MEDiml-pkg) and a no-code desktop application (MEDiml-app). Both run on the same computational engine, and code generation exports graphically configured workflows as executable Python code. Feature extraction follows the Image Biomarker Standardization Initiative (IBSI) standards. MEDiml is built around complexity minimization: features are grouped into levels of increasing complexity (morphological, intensity, textural,l and filter-based), a model is trained at each level, and the simplest level not significantly outperformed by more complex ones is retained. Applied to five oncological datasets (2,104 scans), MEDiml achieved AUCs of 0.65 to 0.82, with morphological or intensity features sufficient in four of the five tasks. Resources: www.mediml.app.

0.28

Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

cs.CV ·2026-11-17 ·Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel +1 more
publishedcode/data similarity 0.69
Abstract · Accepted at WACV 2027. Code: https://github.com/StanfordMIMI/data-curation-3d-medical-vlm

Training 3D vision-language models (VLMs) on large medical imaging datasets collected across institutions is constrained by data quality. Vast, uncurated pools of image-report pairs are characterized by redundancy, class imbalance, and cross-institutional heterogeneity. We address this challenge of data curation for improving 3D VLM pretraining by proposing an offline, training-free, reference-guided data curation recipe. Our approach leverages a small, high-quality reference set to independently extract quality signals for each modality of a large, uncurated pool and merges them through a rank-aggregation step into a single ranking that guides sample selection. We validate this method on datasets comprising 35k 3D abdominal CT volume-report pairs from two institutions and 58k 2D chest X-ray image-report pairs. On 3D CT, using our reference-guided data curation strategy, our curated model matches the zero-shot disease classification performance of a state-of-the-art baseline (Merlin) while using $3.3\times$ less training data and a reference set of 5k samples. On 2D chest X-rays, our method yields a curated model that matches or exceeds the zero-shot disease classification performance of a model trained on the full pool while using up to $10\times$ less training data and a reference set of only 74 samples. Ablations show that the selection is stable under resampling of the reference, that smaller reference sets still outperform random sampling, and that label rebalancing does not improve performance. To support reproducibility, we release our code.

0.51

Personalized and Adaptive Federated Learning for Canine Cardiomegaly Keypoint Prediction

eess.IV cs.CRcs.CV ·2026-11-13 ·Jialu Li, Youshan Zhang, Honggang Wang
similarity 0.68
Abstract

In the field of medical imaging, limited data and cross-institutional heterogeneity remain major challenges for training robust deep learning models. Federated learning (FL) has emerged as a promising approach that enables collaborative training across institutions while preserving data privacy by keeping datasets local. In this work, we propose a structure-aware personalized and adaptive federated learning framework, PAFL, for automatic vertebral heart score (VHS) estimation and cardiomegaly classification from canine thoracic X-rays. Our method treats the task as anatomical keypoint prediction followed by geometry-based VHS computation, introducing implicit structural consistency and improving interpretability. To address cross-institutional heterogeneity, we adopt a parameter-decomposed architecture that separates shared feature representations from client-specific adaptation modules. Furthermore, we introduce an adaptive, quality-aware aggregation strategy that dynamically weights client contributions based on both dataset size and model quality, thereby enhancing robustness to non-IID data distributions. Experimental results demonstrate that the proposed PAFL framework improves models' predictive performance compared to isolated training and to conventional and existing personalized federated learning (PFL) methods. Our results demonstrate the potential of integrating structure-aware modeling with PFL for reliable and interpretable medical image analysis.

0.13

X-Beat: An Explainable Framework for ECG Image Classification

cs.CV ·2026-09-18 ·Mohammad Sadman Tahsin, Haitham Y. Adarbah, Afzel Noore
benchmark similarity 0.68
Abstract · Accepted to the Workshop on Data Quality Aware, High-Performance, and Trustworthy AI Systems for Healthcare at IEEE/ACM CHASE 2026

Accurate automated interpretation of electrocardio- grams (ECGs) is essential for early detection of cardiac condi- tions such as myocardial infarction and rhythm abnormalities. However, many high-performing deep learning models remain difficult to deploy in clinical settings due to limited transparency and lack of reliability validation. In this work, we present X- Beat, an explainable and reliability-aware benchmark framework for ECG image classification designed to support trustworthy AI systems in healthcare. The proposed framework combines transfer learning with post-hoc explainability and systematic reliability evaluation across four cardiac classes: Abnormal Heartbeat, History of Myocardial Infarction, Myocardial In- farction, and Normal Heartbeat. Multiple ImageNet-pretrained CNN backbones, including EfficientNet-B0, ResNet-50, DenseNet- 121, and MobileNetV3-Large, are evaluated under a unified training protocol. Beyond standard performance metrics, we incorporate Grad-CAM-based visual explanations together with additional analyses, including explanation stability, regional sen- sitivity, and confidence-based reliability assessment, to examine whether model predictions are supported by clinically meaningful evidence. Experimental results show that ResNet-50 achieves the best performance, reaching 91.94% accuracy and a macro F1- score of 0.9098, with strong class separability (AUC up to 0.995). Explanation analyses indicate that the model primarily focuses on waveform-relevant regions, while reliability evaluation suggests that most incorrect predictions occur with lower confidence. Overall, this work provides a structured and reproducible bench- mark for evaluating both predictive performance and explanation reliability in ECG image classification, contributing toward the development of trustworthy and interpretable AI components for clinical decision support systems.

0.41

MAGEFormer: Learning Metric-Consistent Representations for Anisotropic CT Segmentation

cs.CV cs.AI ·2026-10-02 ·Jiaying Li, Paolo Remagnino
top venue similarity 0.67
Abstract

Vision Transformers (ViTs) have shown strong performance in volumetric segmentation, but their effectiveness on clinical CT is limited by an isotropic Euclidean lattice assumption. This conflicts with anisotropic CT acquisition, leading to two key issues: (1) a metric mismatch between voxel indices and physical anatomy, and (2) accuracy degradation from isotropic resampling. To address this, we propose MAGEFormer, a geometry-calibrated framework that embeds physical metric constraints directly into representation learning. Our method introduces Metric-Adaptive Spatial Embedding (MASE) to calibrate positional frequencies using voxel spacing, Geometry-Constrained Attention (GCA) to suppress physically implausible feature correlations, and Geometric View Voting (GVV) to reduce discretization bias during inference. We evaluate MAGEFormer on two multi-organ abdominal CT benchmarks, BTCV and FLARE 22, under a unified protocol against strong CNN and Transformer-based baselines. MAGEFormer achieves the strongest boundary accuracy among the compared methods, with 10.58 mm HD95 on BTCV and 3.40 mm HD95 on FLARE 22, and shows consistent gains in Dice under the same protocol. These results show that geometry-aware internal calibration is more effective than relying on conventional isotropic preprocessing alone for anisotropic CT segmentation.

0.32

COGENT: Counterfactual Gaussian Explanations for Volumetric Medical Images

cs.CV ·2026-08-11 ·Dorian Rząsa, Bartosz Zabdyr, Krzysztof Piekarz, Jakub Grzywaczewski, Bartlomiej Sobieski +5 more
similarity 0.67
Abstract

Explainability is essential for deploying deep learning models in high-stakes medical applications. Existing explainability methods for volumetric imaging predominantly operate in voxel space, overlooking the structured representations introduced by recent advances in 3D scene modeling. We present COGENT (Counterfactual Gaussian Explanations), a framework that generates counterfactual explanations directly in the parameter space of Gaussian-based volumetric representations. Built upon MedGS and the Sybil lung cancer risk prediction model, COGENT optimizes selected Gaussian primitives through a differentiable rendering pipeline, enabling gradients from the downstream predictor to identify representation components that most influence model decisions. Unlike conventional pixel- or voxel-level attribution methods, our approach formulates explainability as a counterfactual optimization problem over an explicit 3D scene representation, producing sparse and spatially localized explanations while preserving anatomical consistency. We evaluate COGENT on lung CT scans using quantitative comparisons with existing explainability methods together with qualitative analysis by medical experts. The results demonstrate that representation-space counterfactual optimization provides clinically meaningful explanations while offering a new perspective on interpreting volumetric deep learning models.

0.04

MedVTok: A General-Purpose Medical Visual Tokenizer

eess.IV cs.CV ·2026-10-26 ·Chenglong Ma, Yuanfeng Ji, Junzhi Ning, Jiyao Liu, Yujie Wei +16 more
published similarity 0.67
Abstract · NeurIPS 2026

Multimodal medical AI requires a common visual interface for encoding heterogeneous imaging evidence for patient condition modeling. However, existing medical visual tokenizers are often tied to a specific dimension and imaging modality, forcing multimodal systems to rely on fragmented and poorly reusable representations. We introduce MedVTok, a general-purpose visual tokenizer that maps 2D images and 3D volumes from diverse imaging modalities into a unified token space. Building such a tokenizer poses two key challenges: preserving anatomical structure across dimensions and capturing clinical semantics across modalities. To this end, MedVTok introduces (i) slice differential regularization, which explicitly models inter-slice anatomical coherence missing in previous per-pixel/per-voxel supervision, and (ii) multi-expert representation alignment, which integrates knowledge from multiple medical expert encoders while retaining modality-specific complementary knowledge. Trained on 28M images and 70K volumes across 9 imaging modalities, MedVTok supports classification, retrieval, segmentation, synthesis, visual question answering, and medical report generation through a single tokenizer. Across 24 benchmarks, MedVTok achieves state-of-the-art performance, demonstrating a scalable token interface that unifies medical image dimension, modality, and task usage.

0.19