CS Paper Radar

Elicitation format changes zero-shot classification accuracy in a medical vision-language model: a two-center evaluation on colorectal histopathology

Anay Sinhal, Amit Sinhal, Arpana Sinhal

cs.CV cs.CLcs.LG ·submitted 2026-11-21 19:15 UTC · v1

Abstract

Background. Verbalized confidence from a hosted medical vision-language model is usually treated as packaging around an unchanged prediction. Methods. We held a nine-class colorectal histopathology prompt fixed except for the requested response format and evaluated MedGemma-27b-it on 10,004 validation and 7,180 external-center PathMNIST patches, with preregistered endpoints, randomized ties, and random floors recomputed for each patch set. Results. Requesting probabilities over all nine classes instead of a ranked top-3 reduced accuracy by 14.8 points on validation, -0.1475 [-0.1594, -0.1353], and 13.4 at the external center, -0.1341 [-0.1484, -0.1196], against chance accuracy of 0.1111. The nine-class prompt uniquely forbade commentary, reasoning, and a chosen answer; removing that prohibition at matched cardinality and token budget recovered +0.1878 [+0.1623, +0.2134] and +0.1911 [+0.1648, +0.2181], while changing cardinality with the prohibition absent moved accuracy by -0.0013 [-0.0300, +0.0280] and -0.0214 [-0.0494, +0.0071]. The nine-class format returned no parseable distribution on 7.6 and 7.7 percent of patches, mostly zero vectors in the two least-textured classes, and deferring these failures first explained its measurable selective-prediction gain. Across four vision-capable models, accuracy did not grade the cost: two models matched on accuracy differed five- to sevenfold. First-token logit entropy routed better than any elicited signal, +0.1820 [+0.1722, +0.1974] versus +0.0493 [+0.0377, +0.0649] relative to each signal's random floor. Conclusions. Response format changes a medical vision-language classifier, and the operative component here was the instruction suppressing an answer. Use logits when available; otherwise request a short ranked list without prohibiting reasoning or a chosen answer.

Comment
34 pages, 6 figures; Supplementary Table S1 and Supplementary Material S2 in ancillary files. Corrects one result reported in the companion preprint "Diagnosing Verbalized Confidence in a Medical Vision-Language Model for Selective Prediction on Colorectal Histopathology Patches" (Sinhal et al., arXiv, 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Diagnosing Verbalized Confidence in a Medical Vision-Language Model for Selective Prediction on Colorectal Histopathology Patches

cs.CV ·2026-11-21 ·Anay Sinhal, Amit Sinhal, Ashish Pandey, Arpana Sinhal
similarity 0.79
Abstract · 39 pages, 7 figures; supplementary material in ancillary files. Under review at Scientific Reports. Code and artifacts: https://doi.org/10.5…

Flagging uncertain histopathology patches for specialist review needs a confidence that is higher when the model is right. We test whether an open medical vision-language model emits one. MedGemma-27b-it and its base Gemma-3-27b-it were run zero-shot under one prompt on 10,004 PathMNIST validation patches and 7,180 patches of a patient-disjoint external cohort. Both are too inaccurate to deploy (40.6% and 35.5%); the object of study is the confidence. MedGemma's verbalized confidence puts 96% of patches at one value; its confidence-correctness AUROC is 0.499 and 0.528, and routing by it moves selective-accuracy AUC by -0.004 and +0.037. Gemma-3 spreads its confidence over nine values, reaches AUROC 0.70, and gains +0.114 and +0.115. MedGemma's label-token probabilities do not rescue it: their validation advantage reverses where the top-20 alternatives include every class. On 1,800-patch subsets of each cohort, stratified on correctness and reweighted to the full splits, agreement across five prompt variants beats random by +0.123 and +0.106, and wording-only paraphrases give +0.100 and, externally and in direction only, +0.054; agreement's external margins over confidence do not survive slide-level clustering. Under one restructured prompt variant, MedGemma's stated confidence routes (+0.112, +0.141), so the failure is tied to a prompt chosen for macro F1.

0.38

PathJev: Decision-Native Vision-Language Modelling for Histopathology

cs.CV cs.LG ·2026-10-23 ·Cristian Tommasino, Antonio M. Rinaldi
code/data similarity 0.68
Abstract · 25 pages, 4 figures. Code: https://github.com/CosmoIknosLab/PathJev ; model and demo: https://huggingface.co/Cristiandieti/PathJev-P

Vision-language models used for decisions in histopathology rarely return calibrated probabilities over the candidates a user cares about. Decision-native models write a question and a candidate set chosen at run time into the input and return a normalised distribution from a small decision head in one forward pass. We build PathJev-P, a decision-native model for histopathology: MedGemma-1.5-4B with LoRA adapters and a decision head, trained on 40,000 patch states from three public collections whose expert labels are turned into typed questions with organ-specific candidate sets and a "none of these" option. In a comparison over 3 seeds with an analysis plan fixed before testing, on test sets without documented overlap with the training data of the backbone, PathJev-P is more accurate than a generative model trained with the same backbone, data and selection rule, the zero-shot pathology model CONCH and a general medical decision model (balanced accuracy 0.541 against 0.492, 0.345 and 0.213); its advantage over the generative model comes from two organs absent from training. The calibration advantage depends on how the generative model's probabilities are read out. With the summed candidate log-likelihood used in previous work, PathJev-P has the lower calibration error (ECE 0.204 against 0.279); with a length-normalised read-out of the same generative model, examined post hoc, the two have similar mean calibration error (0.201) and the generative model is better calibrated on the unseen organs, where PathJev-P remains over-confident. A supervised linear probe on a pathology foundation model is better calibrated in every setting. In a qualitative whole-slide demonstration, PathJev-P labels unsupervised tissue clusters with abstention and separates carcinoma from other tissue while running the model on a fraction of the tiles.

0.64

Native Probability Outputs for Clinical Triage: An Evaluation of Calibration and Decision Accuracy

cs.LG stat.AP ·2026-10-17 ·Liang You, Zhiyin Zhou, Dawei Tang, Chuchu Wu, Jingzhuo Hu
similarity 0.64
Abstract

Patient-facing triage requires an appropriate care recommendation and recognition of when information is insufficient. We evaluate whether Jev, a decision model that returns probabilities over predefined actions, supports both judgments. Using CARE-Bench, we compare Jev with four general-purpose language models and three input-independent baselines across 925 decision points from 439 public cases. On the public test subset, Jev ranks fourth of five models by macro-F1 (0.461) but has the lowest observed multiclass Brier score (0.610), an 18.7\% improvement over uniform prediction (case-bootstrap 95\% interval, 4.9--31.1\%). Noul has lower binary Brier than Choice (0.215 versus 0.276). A evaluation of 453 HealthBench conversations again gives Jev the lowest observed Brier score (0.299), but measures a distinct emergency-referral judgment. Jev combines lower probability error with missed clarification needs in the four-action task. Asking about information sufficiency separately increases recall but also produces frequent unnecessary clarification assignments.

0.10

RefineRank: Joint Box Refinement and Ranking for Surgical Spatio-Temporal Grounding

cs.CV cs.AI ·2026-08-25 ·Linzhe Jiang, Jiayuan Huang, Changhao Zhang, Chunyang Jiang, Zhehua Mao +1 more
theorycode/data similarity 0.62
Abstract · 17 pages, 3 figures

Surgical spatio-temporal grounding (STG) requires locating, at each video time specified by a procedural question, the object that the question asks about. Existing approaches face a trade-off: vision language models understand the question context but produce imprecise coordinates, whereas open-set detectors provide localized candidate boxes whose confidence does not reflect which box answers the question. We introduce RefineRank, which closes this gap at the candidate-box level. A compact trainable module, RefineNet, combines the language and regional features of a frozen medical vision language model with the proposals of a frozen open-set detector: it predicts a bounded coordinate correction and a quality score for every candidate box, and a fixed decoding rule returns the original or refined box with the highest score. On the MedVidBench Official Rankings (Verified), RefineRank records 0.421 STG mIoU, the highest displayed STG score, while its global multi-metric rank is 11. In a controlled evaluation on separate training and evaluation videos, coordinate correction raises the candidate oracle upper bound from 0.6772 to 0.7302, and ranking the joint pool of original and refined candidates by their RefineNet scores improves STG mIoU from 0.2719 to 0.4534, whereas separately trained selectors over the same pool reach at most 0.4186. These results show that a small box-level module can reconcile question understanding with precise localization without retraining either backbone. Code is available at [https://github.com/linzhe001/RefineRank](https://github.com/linzhe001/RefineRank).

0.32

Rethinking Correctness for Uncertainty Estimation in Clinical Prediction with Vision-Language Models

cs.LG ·2026-09-14 ·Mingcheng Zhu, Jinning Liang, Tingting Zhu
similarity 0.61
Abstract · 5 pages, 3 figures

Vision-language models are increasingly explored for clinical prediction from electronic health records and medical images, where identifying unreliable predictions is important for safe deployment. Uncertainty estimation (UE) enables detecting such predictions, but its evaluation depends on a correctness criterion that determines whether each model output is correct. If this criterion disagrees with human judgement or distorts downstream UE performance, conclusions about model reliability can be misleading. We introduce a two-axis framework that evaluates correctness criteria by their agreement with human judgements and fidelity to human-referenced UE performance. We assess eight criteria across three clinical prediction tasks and three models using 450 predictions annotated by two reviewers. Across the audited tasks, canonical exact matching (EM) achieved the highest observed human agreement and lowest UE distortion, while the BERT-based matching (BEM) and LLM-judge also showed strong human agreement. Across four UE methods and 23,254 clinical predictions, criterion choice changed error-detection AUROC by up to 0.146 and reversed the relative ranking of UE methods. The LLM-judge also selectively accepted invalid or uncertain outputs, accepting 16 of 30 such human-identified errors. These results demonstrate that correctness assessment is an integral component of clinical UE evaluation and should be validated before UE methods are compared.

0.18

RetiJev: Fast and Source-Grounded Ophthalmic Decision Models

cs.CL cs.AI ·2026-10-22 ·Bo Liu, Lianyu Wang, Meng Wang, Ching-Yu Cheng, Huazhu Fu
benchmarkcode/data similarity 0.61
Abstract

Ophthalmic clinical decision support requires fast, accurate, and privacy-preserving inference, yet autoregressive large language models (LLMs) incur substantial latency and computational overhead for decisions among predefined actions. We therefore investigate a decision-oriented alternative to generative reasoning. Specifically, we first introduce RetiJev-Data, a source-grounded ophthalmology corpus comprising 78,158 clinical-decision and diagnosis questions derived from articles in PubMed Central and a MeSH vocabulary covering 531 eye diseases, and 50,074 guideline-grading questions spanning 11 grading systems, along with a 24,662-question evaluation benchmark. Based on this, we develop RetiJev, a family of 0.8B-9B decision models that directly score candidate answers without autoregressive decoding. Across all model sizes, RetiJev outperforms both a 27B LLM and the commercial Jev 1.13 decision model on guideline grading by 10.4-23.0 points. RetiJev-9B further achieves the highest accuracy on clinical decisions, improving over both baselines by 5.4-6.5 points while matching them on diagnosis. It answers a case in 158 ms on one GPU, 3.5x faster than LLM generation and 470x faster than reasoning. Models are released at https://github.com/Awenbocc/RetiJev.

0.51

Instance-preserving graded semantic reporting for surgical action triplets

cs.CV ·2026-11-09 ·Yanchong Xue, Wanting Zhang, Lingtao Yu, Guochao Zhang
similarity 0.60
Abstract

Complete-or-reject reporting of surgical action triplets can discard a correctly identified instrument and action when the target is uncertain. We introduce instance-preserving graded semantic reporting, which separates instance selection from the choice of semantic detail. Each selected instance retains its predicted mask and labels while hierarchical correctness scores guide instrument (I), instrument-verb (IV), or complete instrument-verb-target (IVT) reporting. The utility-increment rule DELTA weighs the expected gain from finer reporting against its error cost. We compare three decision rules on 5,641 test frames from eight surgical videos using fixed predictions and scores. At the 10% development calibration target, DELTA retains correct partial reports for 80.0% of candidates rejected by a matched complete-or-reject baseline (5,329/6,662). Adding IV increases source-normalized weighted correct-report yield by 19.13 to 23.13 per 100 frames across all three rules relative to separately recalibrated I/IVT controls. Weighted reporting risk changes by -0.77 to +1.01 percentage points, with complete correct-triplet counts unchanged or reduced. Graded reporting makes partial surgical predictions available as localized descriptions, with an explicit trade-off between report utility and completeness.

0.17

What Language Adds, and at What Cost: Four Controlled Probes of Pathology Vision-Language Models

cs.CV q-bio.QM ·2026-10-19 ·Wenhao Zhang, Zhongliang Zhou, Yi Ping, Zirui Wang, Sheng Li
similarity 0.60
Abstract

Vision--language models (VLMs) promise to make computational pathology queryable and able to draft reports, but how much language adds beyond the vision backbone is unclear, because almost every system is evaluated by its developers on test sets of their own choosing. We grade published evidence by how it was produced and test four claims with controlled probes that reuse released checkpoints and public data, varying one input at a time. Report text adds prognostic signal: adding a frozen embedding of the stage-redacted report to a slide embedding raises the pooled C-index by 0.019 for progression-free interval and by 0.016 for overall survival across 1{,}633 TCGA patients, and restoring the stage statement adds nothing. Prompts add no measurable accuracy at inference: with features and pooling fixed, zero-shot classification is statistically indistinguishable from a supervised linear probe for lung and renal cancer subtyping. Slide-level question answering is barely grounded: SlideChat answers 74.82\% of SlideBench-VQA(TCGA) items correctly with the slide and 74.41\% without it, whereas its language backbone alone reaches 43.52\%. Paraphrasing leaves accuracy unchanged but flips 8--23\% of answers. Self-reported gains from agentic navigation and few-shot language priors cannot yet be attributed to language. Language thus adds real but narrow value, and we propose minimum controls that would expose these failure modes in future evaluations.

0.18