CS Paper Radar

Flagging Batch Shift in Flow Cytometry using Jeffreys Divergence between Gaussian Mixtures

Jonathan Legrand, Aguirre Mimoun, Audrey Bidet, Pierre-Yves Dumas, Christ{è}le Etchegaray, Baudouin Denis de Senneville

cs.LG ·submitted 2026-11-23 08:39 UTC · v1

Abstract

Machine learning models for clinical flow cytometry are usually evaluated on data drawn from their training distribution. In routine practice, however, acquisition conditions and reagents may change, potentially making predictions unreliable without warning. We propose a model agnostic criterion for prediction reliability based on a notion of distance from the training distribution: each patient sample is represented by a Gaussian mixture model, and its Jeffreys divergence to a reference fitted on the training data is estimated using Monte Carlo integration. We illustrate our approach on real-life shifted cohorts of acute myeloid leukaemia patients, using a classifier trained to predict NPM1 mutation status. First, we show graphically and statistically that pairwise divergences capture acquisition cohort structure. We then calibrate a rejection threshold on a subset of shifted cohort samples and evaluate it on held-out subjects. Across 20 runs, the misclassification rate of rejected samples was 2.5 times larger than for retained samples. These results suggest that input divergence can help identify unreliable predictions, providing a strong candidate component for abstention frameworks, along with quality control measures and classifier confidence.

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable Multi-Instance Learning Enables Early Prediction of Key Molecular Alterations from Routine Flow Cytometry in Acute Myeloid Leukemia

cs.LG ·2026-09-16 ·Jonathan Legrand, Aguirre Mimoun, Baudouin Denis de Senneville, Audrey Bidet, Pierre-Yves Dumas +1 more
similarity 0.71
Abstract

Background: Molecular testing for NPM1 and FLT3-ITD mutations guides critical early treatment decisions in acute myeloid leukemia (AML), but results can take weeks, long after these decisions must be made. Flow cytometry, already performed within hours of admission as part of routine care, may carry enough signal to predict these mutations directly, without added cost or delay. Methods: We developed an interpretable multi-instance learning classifier based on a decision tree, in which each patient sample is modeled as a collection of individual cells and mutation status is inferred from cell-level predictions. The model was benchmarked against a random forest trained on clinical variables and a deep convolutional neural network adapted for multitube flow cytometry data. Performance was assessed by cross-validation on a discovery cohort of 197 patients and tested on an independent cohort of 161 patients, using the area under the receiver operating characteristic curve (AUROC) and positive predictive value. Results: In cross-validation on the discovery cohort, the MIL model achieved mean AUROCs of 0.96 (SD=0.05) for NPM1 and 0.86 (SD=0.10) for FLT3-ITD, outperforming the clinical baseline and matching deep learning approaches. The model then successfully generalized to the independent test cohort of 161 patients, reaching AUROCs of 0.90 (NPM1) and 0.82 (FLT3-ITD), with positive predictive values of 0.87 and 0.68, respectively. Cell-level interpretation recovered established immunophenotypic signatures (CD33${}^{+}$ /CD34___ for NPM1-mutated cases, CD33${}^{+}$ /low side-scatter for FLT3-ITD), directly linking model predictions to known biology. Conclusions: These results show that an interpretable model applied to data already collected in routine care can predict AML molecular status within hours, offering a practical route to earlier, biology-informed treatment decisions.

0.20

Scalable Bayesian Gaussian Process Classification for Cancer Histopathology: Calibrated Uncertainty Under Distribution Shift

cs.LG ·2026-11-04 ·Yunru Zheng, Wun Ting Chan, Sampras Dsouza, Zhenyu Hong
similarity 0.66
Abstract

Reliable uncertainty quantification is essential for clinical deployment of cancer diagnosis models, yet neural networks and variational Gaussian process methods can produce overconfident predictions, particularly under the distribution shifts that arise when models trained at one hospital are applied at another. We present a scalable Bayesian Gaussian Process Classification (GPC) framework that operates on frozen pathology foundation model embeddings (Phikon) and combines accelerated Randomly Pivoted Cholesky (RPCholesky) for low-rank kernel factorization, Hamiltonian Monte Carlo (HMC) with non-centered parameterization for posterior sampling, and a pivots-as-inducing-points scheme for prediction. This makes HMC posterior sampling in the low-rank latent representation tractable at N approximately 300,000 training points, enabling HC-based low-rank GPC on substantially larger datasets than prior MCMC-based demonstrations. We evaluate on two histopathology benchmarks for breast cancer metastasis detection: PCam and CAMELYON17-WILDS, where the latter tests calibration under hospital-level distribution shift. Compared to stochastic variational GP and neural network baselines, our method improves calibration and predictive performance - reducing expected calibration error by up to 88% and false negative rate by up to 90% - with the largest gains appearing under distribution shift, suggesting that HMC-based posterior sampling provides more trustworthy uncertainty estimates for cross-site pathology classification.

0.12

Pathology Transport: Optimal-Transport Explanations for Clinical Data, and When Their Heatmaps (Fail to) Localize Disease

cs.LG ·2026-08-18 ·Lalit Kumar
benchmark similarity 0.63
Abstract

Generative models promise a route to explainable clinical AI: rather than probe a classifier, model the distributions of healthy and diseased patients and read explanations off the geometry between them. We build such a system - an optimal-transport rectified flow trained between two clinical distributions - and use it to ask a pointed question the field too rarely tests: do the resulting explanation heatmaps actually localize disease? On tabular tumour biomarkers (Breast Cancer Wisconsin) a single flow yields per-patient counterfactuals, an unsupervised malignancy score (AUROC 0.91; 0.93 +/- 0.01 across five seeds), and a label-free attribution that agrees with a supervised classifier (r ~ 0.5) - a compact, honest interpretability engine, though it never out-predicts logistic regression. Moving to chest X-rays, we show the transport heatmap is a population-level signal, not a localiser; a reconstruction-based, identity-preserving variant does localize synthetic lesions (pointing game 0.52), yet on real RSNA radiologist boxes it collapses to chance while only supervised Grad-CAM stays above it. The central result is a synthetic-to-real gap: label-free heatmaps that look compelling on planted lesions are not evidence of real localisation. We contribute a reusable optimal-transport recipe for generative explanations and a controlled benchmark for stress-testing whether they localize.

0.15

Detecting Unreliable Classifications from Quantized Models

cs.CV ·2026-10-13 ·Ananya Kotla, Jorge T. Gomez
hot direction similarity 0.62
Abstract · 1 figure, 5 tables

Post-training INT8 quantization is typically validated by checking accuracy retention, which requires ground-truth labels often unavailable in low-resource clinical settings. We show a label-free alternative: comparing a model's own output before and after quantization. We compute cosine similarity between the FP32 and INT8 models' output probability vectors for each prediction, which requires only a single forward pass. This output-agreement similarity separates lower-accuracy predictions across four evaluated architectures (ResNet-50, VGG-16-BN, Wide ResNet-50, and ViT-B/16) under fixed-percentile splits, outperforming a confidence-only baseline for all four. These results show that quantized models can be compared to their baselines to assess their drift and determine whether they are well suited for clinical deployment.

0.31

Guidance for Prior Change via Density Ratio Estimation

cs.LG stat.MLstat.ME ·2026-08-22 ·Yichen Zang, Jiun-Yi Lin, Song Liu
code/data similarity 0.60
Abstract

Simulation-Based Inference (SBI) serves as a vital framework for parameter inference in scientific fields where simulators involve intractable likelihoods, yet while amortized generative models offer rapid posterior estimation, they are often restricted by the specific priors used during training, thereby limiting their flexibility as prior knowledge evolves. To address this prior dependency, PriorGuide was introduced as an inference-time guidance method, but due to its intractable formulation, it relies on Gaussian approximations of the reverse transition kernel and Gaussian mixture model fitting for the prior ratio, both of which introduce systematic bias. Motivated by these limitations, we propose an unbiased test-time guidance framework that leverages Density Ratio Estimation (DRE) to learn a score guidance term, effectively decoupling the inference process from the prior training. Moreover, our framework remains agnostic to the specific density ratio estimators, making it a general and flexible framework for handling prior changes. Experimental results across multiple tasks demonstrate that our method matches or outperforms PriorGuide on C2ST and MMD in most tasks while maintaining robustness even under limited overlap between the training and target priors. Furthermore, we apply our method to Bayesian updating for parameter inference from planetary light-curve data, where it also demonstrates strong effectiveness and robustness. Code is available at https://github.com/a-chenchen/dre-based-prior-guidance .

0.53

Rethinking Class Imbalance for Single-Cell Foundation Models: A Systematic Benchmark Across Architectures and Long-Tail Loss Functions

cs.LG ·2026-09-20 ·Zeyu Dong, Jiahui Zhong
benchmark similarity 0.59
Abstract

Single-cell foundation models (scGPT, scBERT, Geneformer) achieve cell-type classification accuracy up to 97.5% in our experiments, yet this aggregate accuracy can mask systematic failure on rare, often disease-relevant cell populations that long-tail loss functions are widely assumed to address. We present a systematic benchmark of six long-tail loss functions (cross-entropy, weighted CE, class-balanced loss, focal loss, LDAM, logit-adjusted softmax) across three architectures and three datasets (Multiple Sclerosis, Zheng68K, human Pancreas), totaling 162 controlled training runs (3 backbones x 3 datasets x 6 losses x 3 seeds). The gap between overall accuracy, Macro-F1, and rare-class recall under plain cross-entropy is consistent across all nine (architecture, dataset) settings, driven by dataset structure rather than pretraining. Rare-class failure itself splits into two regimes with distinct embedding-geometry signatures, visible before any loss is chosen: some classes are recoverable by the right loss, while others retain linear separability yet are absorbed into unrelated classes' neighborhoods under every evaluated loss and architecture. Among the recoverable classes, the efficacy of reweighting is predicted by a class's absolute training-set size, rather than its share of the dataset or the dataset's overall imbalance ratio. Class-balanced loss and LDAM are the most consistent choices across all nine settings, while logit adjustment trades rare-class precision for recall rather than improving both. Our results give both a reusable benchmark and mechanism-grounded practical guidelines for combining foundation models with imbalanced biological data.

0.36

The Ceiling Is in the Channel: Auditing Learner Gaps and Measurement Frontiers in Clinical Prediction

cs.AI ·2026-09-01 ·Sayeed Shafayet Chowdhury, Nusrat Jahan, Snehasis Mukhopadhyay, Shiaofen Fang, Vijay R. Ramakrishnan
similarity 0.59
Abstract

Clinical prediction can saturate for two different reasons: a fitted learner may fail to extract available information, or the recorded variables may impose a population frontier. We separate these quantities through the \emph{learner gap} and the \emph{measurement-channel ceiling}. Optimal balanced accuracy is characterized by total-variation separation, yielding architecture invariance, a sharp partial-identification result under replacement contamination, a cross-fitted ceiling estimator, and exact conditions for multimodal decision improvement. We add two finite-sample diagnostics, namely a label-permutation optimism floor and an underfit curve, and validate the audit on three real cohorts: UCI readmission ($n=99{,}343$), BRFSS diabetes ($n=253{,}680$), and NHANES HbA1c ($n=10{,}219$). Well-tuned gradient boosting nearly reaches the estimated frontier in UCI and BRFSS, whereas deliberately or practically deficient learners retain large gaps. NHANES yields a null difference between questionnaire and measured marginal frontiers but a significant joint complementarity gain, refining the simplistic claim that an objective modality must dominate. Across all cohorts, modest AUROC gains coexist with substantially larger Bayes decision-flip rates, and several architectures estimate similar frontiers while their achieved balanced accuracy differs sharply. A PRISMA-guided synthesis of 104 clinical tasks then shows that the same channel-level regularities recur across more than 18 disease categories: a broad but non-universal structured-clinical region, diminishing same-channel gains across model families, and higher performance when measurement channels change. The framework converts saturation from an empirical observation into an auditable decision: improve the learner when headroom remains; improve measurement when it does not.

0.18

Diagnosing Low-Confidence Patient Profiles via Localized Harmful Covariate Shift Detection

cs.LG cs.AI ·2026-10-13 ·Olivier Lefebvre, Hakima Laribi, Dan Poenaru, Martin Vallières
publishedcode/data similarity 0.59
Abstract · Accepted at SMASH (Symposium on Machine Learning and Applications in Healthcare) 2026. Code available at https://github.com/MEDomicsLab/stud…

Before deploying clinical prediction models, their reliability must be assessed to ensure safe use. Errors may arise from distribution shifts between training and deployment or from heterogeneous performance where the model systematically underperforms for certain patient subgroups. Yet most post-hoc diagnostic methods evaluate reliability only at the population level, checking whether the deployment data resemble the training data and whether the model performs well on average, without accounting for heterogeneity that may cause some patients to be disproportionately affected. We propose a unified diagnostic pipeline that combines both perspectives. MED3pa first discovers interpretable low-confidence patient profiles, and Detectron is then applied within each profile to test whether its degradation is associated with a detectable harmful covariate shift. Across three clinical prediction tasks and three injected subgroup shifts in MIMIC-IV, we find that shift detectability itself is informative. An injected age shift, undetectable at the population level, was nonetheless localized to specific degraded profiles, whereas sex- and race-related shifts were detected broadly and therefore offered little guidance for identifying the most affected patients.

0.47