Data Centers: The Error of Generalizing Environmental and Socioeconomic Impacts. The Need for a Contextualized Assessment of Computing Infrastructure in Brazil and Worldwide

Elzo Brito dos Santos Filho

cs.CY ·submitted 2026-11-25 12:34 UTC · v1

Abstract

The rapid expansion of artificial intelligence and cloud computing has intensified debates about the environmental and socioeconomic impacts of data centers, including electricity and water consumption, noise, land use, and employment. A recurring methodological problem in these debates is the use of global data, or of evidence produced in a particular country, to draw conclusions about facilities located in very different settings. This paper argues that the impacts of a data center depend on the geographic, climatic, energy, technological, economic, and regulatory conditions of the territory where it operates, and must therefore be assessed at the appropriate territorial and technological scale. Using Brazil as a case, we discuss the country's predominantly renewable electricity mix and the curtailment of renewable generation, the reported prevalence of closed-loop cooling, national and municipal noise regulations, the water-efficiency requirement of the new Redata tax regime, and the ongoing litigation over the Pec{é}m data center in the state of Cear{á}. We also examine a recent study of data centers in Northern Virginia, showing the limits of its external validity and of its noise measurements. We propose a multiscale assessment framework and conclude that international evidence should inform which questions are asked, not predetermine the answers -- a principle that applies equally to claims of harm and to claims of safety.

Comment
11 pages, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Data Center Governance Under AI Expansion Pressures

cs.CY ·2026-11-12 ·Yacine Jernite, Sasha Luccioni, Bruna Trevelin, Angela Lee, Carolina Molina +1 more
similarity 0.68
Abstract

The promised benefits of data centers are global, but their negative impacts are very much local, affecting the energy bills, aquifers and living environments of citizens across the United States. While governments and authorities have historically provided data centers with incentives such as tax credits and exemptions, AI's aggressive growth in scale has changed this dynamic, and recent months have seen them issue bills and file lawsuits in order to ensure that data centers remain a net positive influence on their legislatures. Existing pieces of federal legislation -- such as the Public Trust Doctrine, the Pollution Prevention, Clean Air and Safe Drinking Water Acts -- exist to manage natural resources, but their scope remains contested, and the current federal government's stance on competitiveness and growth of AI has put the onus on regional governments to endeavor to protect local resources. There are also state- and regional laws and regulations that are relevant for building and operating data centers since, in practice, they require substantial land, electricity, water, and infrastructure at a local level. Given this situation, communities are currently provided with the opportunity to raise their concerns regarding the potential negative impacts of how data centers are built and operated, and have existing regulations that can be used to put pressure on data center operators.

0.22

Moving bits instead of watts: Accelerating global AI data-centre deployment at the energy-digital-water-land nexus

eess.SY ·2026-10-26 ·Jiawei Qu, Xiaoying Shi, Kai Hou, Hongjie Jia, Jinyue Yan
similarity 0.65
Abstract

Artificial intelligence is driving an unprecedented expansion of data centres. However, this growth is increasingly stalled by grid transmission constraints that trap new data centres in years-long connection queues. Unlike electricity, computation can be moved across the globe through fibre-optic networks, but whether this spatial transfer can bypass constrained grids and accelerate global AI data-centre deployment remains unknown. Here we develop a global framework that places future data-centre capacity in energy-abundant regions and routes computational workloads through fibre-optic networks rather than transmitting electricity. We evaluate the framework through more than 11 million hourly operation simulations at subnational resolution, integrating constraints on energy systems, water, digital connectivity, land and financing risk. Results show that across multiple data-centre development and climate-policy scenarios, leveraging global data transfer allows new data centres to be sited where these conditions are favourable, lowering construction costs by 44-47% and carbon emissions by 38%. By treating the global fibre-optic network as an energy-system asset, it avoids 34-67 GW of high-voltage transmission capacity, comparable in magnitude to Italy's national peak electricity demand. Crucially, this methodology could bring more than 95% of connection-delayed data centres online in 2030, with Canada, the Nordic countries and the Arabian Peninsula emerging as preferred locations for data-centre development. Our findings establish computational mobility as an alternative to energy-system expansion, informing the coordinated global development of energy and artificial-intelligence infrastructure.

0.10

Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development

eess.SY cs.CYcs.DC ·2026-09-21 ·Garrett Alston, Nancy Love, Rabab Haider
code/data similarity 0.62
Abstract · 12 pages; 8 figures; 6 tables; appendix

Data centers are being developed at an unprecedented pace, yet their energy and water impacts, and the spatial and temporal distribution of these impacts, remain poorly characterized. Data centers consume water for cooling (direct) and through electricity generation (indirect). Decisions on siting and cooling technology result in water-energy trade-offs that extend impacts beyond the facility's location. Existing assessment frameworks rely on facility efficiency metrics and average grid water intensity factors, suppressing the temporal impacts of data center load and generation availability. They also attribute indirect consumption to the facility's location rather than to the generators (and corresponding hydrologic regions) that respond to the added load, misattributing spatial impacts. To close this gap, we develop a computational model of the data center-energy-water nexus that links facility cooling and electricity demand with hourly economic dispatch, generator-level water consumption, and monthly subbasin depletion. Built on open-source data, the model resolves where and when water is consumed, and where this consumption compounds existing water risk or creates new risk. Using the model, we study different cooling configurations and proposed developments in the state of Michigan. Air-cooled data centers halve total water consumption relative to evaporative cooling, but increase electricity demand and raise indirect water consumption by one-third, shifting the water footprint from the facility to generators. Mapping these changes to subbasins reveals depletion increases beyond the data center sites, in regions that facility-level reporting may overlook. These results show that data center water and energy impacts cannot be assessed in isolation, motivating the need for integrated modeling to inform siting, design, and reporting practices.

0.22

Beyond PUE: A Local Impact Audit Framework for Data Center Environmental Accountability

cs.CY cs.AI ·2026-09-20 ·Sharifa Sultana, Syed Ishtiaque Ahmed
similarity 0.60
Abstract

Standard data center sustainability metrics, including Power Usage Effectiveness (PUE), Water Usage Effectiveness (WUE), and Carbon Usage Effectiveness (CUE), measure a facility's resource use and emissions intensity, normalized to IT energy use, without directly representing local resource scarcity, infrastructure capacity, or social footprint. This gap has become politically consequential. In the first quarter of 2026 alone, local opposition delayed or canceled roughly $130 billion in projects across the United States, driven overwhelmingly by recurring concerns over water use, power demand, infrastructure capacity, and transparency rather than internal efficiency, matching the total for all of 2025 [11]. We propose a five-category local impact audit framework covering efficiency, water stewardship, carbon and renewables, regulatory compliance, and local disclosure. The framework is designed for recurring quarterly assessment and independent verification against public records. We illustrate its application using publicly available data from three Illinois facilities that are currently at the center of local policy disputes, and we examine the data-access barriers that constrain independent verification. We position this framework as both a research contribution and a practical instrument for county-level policymakers evaluating data center permitting and moratorium decisions.

0.24

Computing at Sea: Floating and Offshore Data Centres as a Pathway to Sustainable AI Infrastructure

eess.SY cs.AI ·2026-09-11 ·Cheng Siong Chin, Jianhua Zhang, M. Venkateshkumar
similarity 0.59
Abstract · 7 pages, 2 figures, 2 tables

The rapid expansion of artificial intelligence is transforming data centres into one of the world's fastest-growing sources of electricity demand. As AI systems scale in size and capability, the physical infrastructure supporting computation is approaching critical limits in energy availability, cooling capacity, land use, freshwater consumption, and carbon management. Conventional land-based data centres are increasingly constrained by urban land competition, grid congestion, environmental pressures, and lengthy permitting processes, raising fundamental questions about where future computing infrastructure can sustainably exist. This article examines floating and offshore data centres as an emerging alternative model for digital infrastructure. By relocating computation to marine environments, offshore systems can exploit the ocean's natural cooling capacity, reduce freshwater dependence, and enable direct integration with offshore renewable energy resources such as wind, wave, and tidal power. Early deployments have demonstrated the potential for significantly improved energy efficiency and operational reliability compared with conventional facilities, while also opening new possibilities for distributed and resilient computing architectures. The article explores how offshore computing may reshape the future relationship between electrification, renewable energy, and large-scale AI infrastructure. It analyses the opportunities and trade-offs associated with marine deployment, including environmental impacts, engineering design challenges, economic feasibility, and regulatory governance. Rather than treating offshore data centres as experimental novelties, the article presents them as part of a broader systems-level transition in how society may power, cool, and sustain the next generation of computational growth.

0.29

Water-Energy-Data nexus reveals sustainability gaps and priorities for AI infrastructure

cs.CY ·2026-10-16 ·Jincheng Huang, Guoan Xiao, Xin Lan, Caichun Yin, Zhimeng Jiang +2 more
similarity 0.59
Abstract

The rapid growth of artificial intelligence (AI) depends on interconnected water, energy, and data systems spanning infrastructure life cycles and diverse geographies, with the potential to intensify water and energy insecurity, exacerbate social inequities and lead to cascading sustainability issues globally. Yet assessments commonly examine them separately, limiting our understanding of where resource pressures arise, how they are transferred across space, and who bears their consequences. To address these challenges, we established a water-energy-data (WED) nexus framework that captures the spatial and life-cycle dependencies of AI infrastructure, and use large language models to synthesize 12,825 water- or energy-related studies across four resource-intensive AI infrastructure activities: mineral extraction, semiconductor manufacturing, data center operation and electronic-waste processing. The evidence map identifies a mismatch between the interconnected activities supporting AI infrastructure and boundaries used to assess them. Researchers assess operational energy more than water use and other indirect demands, while interactions across locations and life-cycle activities remain understudied. These gaps obscure how resource demands shift among infrastructure nodes and regions, and how data-enabled benefits compare with their underlying costs. The WED nexus provides a foundation for integrated assessment of spatially metacoupled systems, while the evidence map can inform priorities for managing the sustainability implications of the AI boom.

0.10

On the Optimal Co-location of Data Centers with Renewable Energy Sources in SIDS

eess.SY math.OC ·2026-09-16 ·Shankar Ramharack, Patrick Hosein, Rajiv Sahadeo
top venue similarity 0.58
Abstract · 6 pages, 4 figures, accepted to 2026 IEEE Caribbean Conference (CaribCon) - Track 3 - Smart Systems, Robotics, and Automation

The rapid expansion of data centers presents both economic opportunities and systemic risks for Caribbean Small Island Developing States~(SIDS). This paper develops a PyPSA-based capacity expansion framework for optimal co-location of data centers with renewable energy infrastructure, incorporating behind-the-meter battery storage, workload flexibility (70\%/30\% inflexible/flexible split), and multi-bus transmission topology. Two case studies are examined: Trinidad~\&~Tobago (single-bus, 92\,MW Brechin Castle solar, 5\,MW data center) and Jamaica (4-bus 138\,kV JPS network, 15\,MW data center at Kingston). Jamaica's optimum deploys 405\,MW solar, 278\,MW wind, 800\,MWh grid-scale BESS, and 84\,MWh behind-the-meter BESS, achieving 42.5\% renewable penetration; Trinidad's gas-anchored optimum builds no new RE, and a sensitivity analysis shows solar entering at gas costs above \$65--70/MWh, a carbon price of \$25--50/tCO$_2$, or solar CAPEX of \$800/kW. A post-hoc distributionally robust stress test evaluates hurricane resilience, and a novel 10-factor siting framework addresses the regulatory gap in SIDS that lack data-center-specific zoning. Results show that energy-optimal locations may score poorly on societal criteria---noise, freshwater stress, zoning readiness. This demonstrates the need for integrated planning tools in small island contexts.

0.33

GreenDirector: carbon- and water-aware workload placement for sustainable computing

cs.DC ·2026-09-11 ·Jaime Iglesias Blanco, Ignacio Heredia, María Castrillo, Andrei Tsaregorodtsev, Mazen Ezzeddine +1 more
similarity 0.57
Abstract

The rapid growth of data center electricity demand, accelerated by AI, makes carbon-only accounting an incomplete measure of computing's environmental impact: low-carbon electricity mixes are often water-intensive, and the resulting harm depends on local, seasonal scarcity rather than on the volume of water consumed. We propose the Environmental Score (ES), a unified, dimensionless index in $[0, 100]$ that jointly captures the carbon footprint and the spatial-temporal, scarcity-weighted water impact of the electricity a workload consumes. It combines real-time, cross-border electricity flow tracing with monthly AWARE2.0 water-scarcity characterization factors, weighting global greenhouse-gas emissions together with the local, seasonal severity of water stress. Building on it, we define the Green Score (GS), a scheduling metric proportional to the useful computational work delivered per unit of real environmental impact, which also accounts for data center power and hardware efficiency. We add both metrics as a green-affinity feature to the GreenDirector schedulers of two production federated infrastructures, the AI4EOSC scientific cloud and the DIRAC workload management system. In AI4EOSC, a cluster-filling experiment over four pan-European providers shows that greener sites are filled first without degrading scheduling latency or end-user experience. In DIRAC, a trace-driven simulation of 133,631 jobs and a preliminary production deployment for the KM3NeT community reduce carbon emissions and improve carbon efficiency by about 40\%, while making the carbon-water trade-off explicit when the lowest-carbon site also carries higher water stress. The results show that hydrological stress can be dynamically weighted into workload placement in live, multi-tenant systems

0.19