CS Paper Radar

Mitigating Hallucinations in Medical Question Answering on ESC Cardiology Guidelines: Evaluation and Retrieval Optimization

Ilkin Masimov, Rufana Baghirli, Muhammad Rashid

cs.CL ·submitted 2026-11-25 14:15 UTC · v1
code/data

Abstract

Background: Large language models produce hallucinations in medical question answering (QA). Verify-and-revise pipelines that check atomic claims against retrieved guideline evidence are a standard mitigation, but evaluations almost universally treat the verifier's output as ground truth, an assumption rarely tested. Objective: To measure, claim by claim against human judgement, how such a pipeline fails in a guideline-grounded clinical setting. Methods: We built a dataset of 160 questions (100 patient vignettes from 89 de-identified cases, 60 fact-based) over four recent ESC cardiology guidelines, all approved by a practising internist, and a retrieval corpus of 627 hand-verified guideline records at two chunk granularities. A five-stage pipeline was run under four retrieval configurations and three independent runs (1920 arm-runs); all 606 first-pass refuted claims were manually audited, an independent judge re-judged 906 decisions, and the expert blindly reviewed 100 accepted claims. Results: Only 44.7-50.6% of flagged claims were true hallucinations. Correction loops converged in 85.2-95.1% of cases, yet 35% of genuine final errors were introduced by correction. Single-run true-hallucination recall was 35.6-41.2%, the three-run union 71-80%; verifier agreement was moderate (kappa = 0.505). The blind probe estimated the accepted-claim miss rate at 3.2% (95% CI 0.7-6.7%). Final genuine-error rate: 1.7% of answers. Conclusion: Claim-level verification reduces hallucinated content by an order of magnitude, but verifier reliability, not generation, is the limiting factor and must be measured, not assumed.

Comment
29 pages, 3 figures, 12 tables. Dataset and code: https://github.com/ilkinmasimov/esc-hallucination-qa

Closest papers

Nearest neighbours by meaning across the whole index.

When Rubrics Fail: Hallucinations Reveal Blind Spots in Medical AI Evaluation

cs.AI ·2026-09-11 ·Griffin Farrow, Lily Sijia Li, Jack Johnson, Tingyan Wang, Philip Torr +2 more
published similarity 0.71
Abstract · Published at NeurIPS 2026 GenAI4Health Workshop

Hallucinations can undermine clinician trust in LLMs, making it important that evaluation methods capture clinically relevant errors. Rubric-based evaluation has become the leading approach for assessing LLMs in medicine, but it is unclear whether rubric scores reflect such errors. We first study this in a controlled setting using MedHallu, finding that more specific rubrics better distinguish correct from hallucinated responses. To test this systematically, we develop a taxonomy of medical hallucination types and a clinician-validated error-injection pipeline that creates matched correct and error-injected responses. Across HealthBench, HealthBench Professional, and LiveMedBench, our clinically relevant hallucinations are missed by rubrics, often leaving scores unchanged. We find that rubrics are most effective when explicitly checking facts, and are less effective for additional or unexpected errors they do not anticipate. A preliminary retrieval-based factuality check recovers some of the rubric-blind errors, suggesting a complementary approach. These findings reveal systematic blind spots in current medical evaluation of LLMs and suggest that rubric scores alone are insufficient to establish clinical reliability, potentially undermining clinician trust and confidence in clinical deployment.

0.57

ROUNDS: Source-Framed Diagnostic Revision after Multi-Turn Clinical Evidence

cs.CL cs.AI ·2026-11-14 ·Jinrui Fang, Runhan Chen, Yining Wu, Jiawei Xu, Xu Yang +4 more
top venuebenchmark similarity 0.69
Abstract · Accepted at Machine Learning for Health (ML4H) 2026, Proceedings Track; to appear in Proceedings of Machine Learning Research (PMLR). 17 pag…

Large language models (LLMs) achieve high scores on medical benchmarks, but does this performance translate into reliable diagnosis as a conversation unfolds? In diagnostic conversations, users can provide clinical findings across multiple turns, ask for a diagnosis without supplying answer options, and introduce opinions from others. Models must therefore form diagnoses from the available evidence and decide how to respond to subsequent advice. We introduce ROUNDS, a framework that evaluates these abilities after a fixed sequence of clinical evidence delivered over multiple turns. ROUNDS compares diagnosis with and without answer options, presents the same incorrect diagnosis under clinician and lay framing, and varies support for competing diagnoses in written five-clinician panels. Across seven models and 1,035 cases from five datasets, average accuracy was 76.9% with answer options and 57.0% without them. Clinician-framed misleading advice produced lower final accuracy than lay-framed advice in every model, with differences of 4.6 to 38.2 percentage points. Initially correct diagnoses more often became incorrect answers than abstentions, and many adopted the suggested disease. Conversely, accuracy increased as more panel members supported the correct diagnosis, including when the majority opinion remained unchanged. These findings reveal a gap between medical benchmark performance and reliable diagnosis in conversation: models respond to external opinions, but remain vulnerable to abandoning correct diagnoses without new clinical evidence.

0.34

How Much Do Legal RAG Systems Still Hallucinate?

cs.CL cs.AI ·2026-08-14 ·Souvick Das, Sallam Abualhaija, Domenico Bianculli
similarity 0.68
Abstract

Hallucination is a major challenge for retrieval-augmented generation (RAG) systems in the legal domain, where ungrounded answers can lead to serious consequences. To better understand this problem, we conduct a fine-grained analysis of hallucination behavior in eight legal RAG systems across two legal corpora, the GDPR (in English) and a national civil law (in French). Using claim-level and answer-level evaluation, we report on hallucination density and severity, analyze performance across question categories and user personas, and validate our findings on an independent set of 142 legal-expert-authored questions. Our results show that hallucinations remain pervasive, ranging from less than 10% of responses for the best-performing systems to nearly half in the worst case. We further find that false-premise questions, containing incorrect assumptions that must be rejected, produce high hallucination rates on the manually-drafted questions.

0.04

Verifiable by Construction: Claim-Level Evaluation of Verbatim Citation in Clinical Question Answering

cs.CL ·2026-09-14 ·Jiashuo Zhang, Yuling Chen, Yvonne Commodore-Mensah, Michael Oberst
similarity 0.68
Abstract

Large language models (LLMs) have been widely adopted for clinical question answering (QA). Current systems can attach citations to their answers, but these often point to broad texts, leaving time-pressed clinicians unable to verify them efficiently. An alternative is to ensure that responses are verifiable by construction: providing fine-grained verbatim quotes from reference material that substantiate claims, so users can verify an answer without opening other documents. In this paper, we evaluate the ability of current models to perform this task end-to-end: from providing citations for every factual claim, to producing verbatim quotes, to ensuring that those quotes fully substantiate the claims. To do so, we build a standardized harness over four clinical practice guidelines and evaluate twelve LLMs on 222 synthetic clinical questions, measuring each of these stages separately. We find that most models can attach verbatim quotes to over 90% of their claims from prompting alone, apart from some lightweight models such as claude-haiku-4.5. Yet these quotes often fail to substantiate every detail of the claims they accompany. For instance, claude-opus-5 produces verbatim quotes for 98.0% of its claims, but fully substantiates only 37.1%. Our work provides insights into the current capability gap of LLMs in building verifiable clinical QA systems, along with artifacts for future research.

0.12

Untangling the Mechanisms of Misleading Context in Medical Question Answering

cs.CL cs.AIcs.LG ·2026-09-02 ·Robin Linzmayer, Noémie Elhadad
benchmark similarity 0.67
Abstract · 25 pages, 10 figures. Submitted to ML4H 2026

Large language models now answer medical questions with expert-level performance. However, the context these systems act on can be misleading, and misleading context can corrupt a model's medical judgment. To understand how misleading context corrupts this judgment, we examine the model's susceptibility to the context, disclosure of it, mechanism of corrupted reasoning, and monitorability of the decision. On the medical reasoning subset of MedMisBench, a clinician-reviewed question-answering benchmark of 8,627 questions, we inject two types of misleading context cues, fabricated evidence and a bare assertion. We test three reasoning models, two that expose their full reasoning trace and one frontier model that exposes only its response. All three are more susceptible to the assertion than to the fabricated evidence, adopting the asserted answer 10 to 27 points more often. The misleading cues are disclosed in 81 to 98% of traces but only 7 to 90% of responses, and the assertion is disclosed less often than evidence based cues. Resampling from reasoning traces without disclosure shows the two cues corrupt reasoning differently, evidence entering early and accumulating while the assertion redirects the conclusion near its end. An LLM monitor catches 78% of corrupted decisions at 5% false positives when reading an open model's trace with guidance, against at most 32% from any response. The misleading context that models are most susceptible to is disclosed least, and was caught reliably only from an open reasoning trace, which frontier providers withhold.

0.21

Where Does Retrieval-Based Open-Ended Evaluation Fail? Automatic Taxonomy Induction from Long-Form Medical Answer Factuality Verification

cs.CL cs.IR ·2026-09-24 ·Heyuan Huang, Jirui Dai, Alexandra DeLucia, Sonal Joshi, Mahsa Yarmohammadi +3 more
top venue similarity 0.67
Abstract · All experiments were done before May 2026 (also all corpus knowledge cutoff date). Accepted as an Oral paper (Best Paper Finalist) at NeurIP…

Retrieval-based factuality evaluation, where LLM-generated claims are verified against evidence from authoritative medical corpora, has become the dominant paradigm for scalable hallucination detection in high-stakes clinical settings. Despite the urgency of reliable and transparent medical fact verification, most systems measure performance with aggregate metrics like F1, which obscure where and why failures occur. Existing RAG diagnostics require gold answers or annotated gold evidence, neither of which exists in this regime. We introduce two comprehensive taxonomies, grounded in a case study on the open-ended MedExpert dataset and 3 closed-ended datasets, decomposing failures into retrieval-stage errors along five quality dimensions, and verifier-reasoning errors into six consecutive steps. We adapt an automatic pattern induction pipeline using LLM-as-Judge to label evidence quality and classify verifier reasoning errors at scale, and then stress-test our findings across 4 retrieval methods and 6 frontier verifier models. Our analysis reveals that scaling model size, adding reasoning effort, expanding to authoritative web sources, and applying medical fine-tuning do not resolve these failure modes, demonstrating that they represent fundamental limitations of the retrieve-then-verify paradigm in open-ended medical settings rather than artifacts of outdated systems. We release our code and data at https://anonymous.4open.science/r/Medical_RAG_eval-4AB5 for the full reproducibility of our results.

0.36

When Retrieval Hurts: Measuring and Explaining Retrieval-Induced Hallucination in Chest X-ray Report Generation

cs.CV ·2026-09-22 ·Emmanuel Idoko, Abdusshakur Olabisi, Shiloh Oni, Adesola Josiah
position similarity 0.67
Abstract · 10 pages, 4 tables

Retrieval-augmented generation is an attractive way to improve chest X-ray reporting, because reports from similar prior studies supply clinical context a general vision-language model lacks. We show the same mechanism is a reliable source of clinical error. Over 100 MIMIC-CXR studies with a frozen LLaVA-1.5 generator and BioMedCLIP retrieval, CheXbert clinical F1 doubles under relevant retrieval (0.201 to 0.402) and collapses to 0.043 under clinically mismatched retrieval, a fifth of the image-only score; the retrieval-induced hallucination rate, counting only unsupported findings traceable to retrieved evidence, rises from 0.00 to 0.76 and 0.98. To show this is not an artefact of evidence-set coverage, we introduce a coincidental-overlap control that scores image-only generations against evidence they never saw, placing the chance base rate at 0.18, four to five times below the observed rates. The generator does not merely acquire findings, it transcribes text: 95% of reports produced under relevant retrieval contain an eight-word span occurring verbatim in the retrieved evidence but absent from the reference, against 0% without retrieval. We then explain the mechanism: a normal chest X-ray retrieves at least one abnormal precedent in 24 of 28 cases, because medical image-embedding similarity is dominated by anatomy and acquisition rather than by the presence of disease. This has a direct design consequence. Retrieval similarity does not predict harm (RIH rates 0.80/0.80/0.60/0.84 across similarity quartiles), so relevance gates conditioned on embedding similarity cannot work; gating on predicted pathology agreement removes 61% of unsupported evidence at no cost to useful coverage. We argue that retrieval-augmented clinical systems must be evaluated under retrieval failure, not only under retrieval success.

0.27

PROVE: Proof-guided Regime-aware Operator Verification for Hallucination Detection in Medical Visual Question Answering

cs.CV cs.MM ·2026-08-28 ·Keyang Zhou, Siyi Li, Zhongnan Shi, Qichao Ying, Wei Tang +1 more
top venue similarity 0.66
Abstract

In medical visual question answering (VQA), hallucinations of vision-language models (VLMs) may lead to confident but incorrect responses, raising the risk of diagnostic errors. Existing hallucination detection methods uniformly estimate the reliability of VLM outputs from response consistency or visual evidence. However, such uniform verification across questions ignores question-specific characteristics, resulting in missed overconfident errors and false alarms from over-verification. We present PROVE (Proof-guided Regime-aware Operator Verification), a black-box detector that adapts verification strategy to the evidential structure of each question. PROVE classifies questions into three verification regimes based on what kind of visual proof they demand, activates a regime-specific subset of five complementary operators, and adjusts operator importance per question through a lightweight calibration layer conditioned on deterministic question-answer features. PROVE uses question-specific evidence to reweight operators and produce a calibrated risk score. Evaluated on 8048 test samples across three medical VQA benchmarks and four frontier VLMs, PROVE achieves 0.821 AUROC, outperforming the strongest baseline by +0.159, with consistent gains across all models and benchmarks.

0.38