CS Paper Radar

Weekly top 10 · eess.IV

2026-W34 Aug 17 – Aug 23, 2026

Ranked from 3,407 papers submitted on 7 days.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works
1

MDFI: A Multi-Domain Features Integration for Compressed Video Quality Enhancement

eess.IV cs.CV ·2026-08-21 ·Sang NguyenQuang, Hieu Bui Minh, Dang BuiDinh, Xiem HoangVan
top venuedatasetcode/data
Abstract

The latest video coding standard, H.266/VVC, has demonstrated significant improvements in compression efficiency compared to H.265/HEVC. Despite its advanced coding techniques, H.266/VVC still faces challenges in meeting the increasing demand for higher perceptual quality and enhanced compression performance. To address these limitations, we propose MDFI (Multi-Domain Features Integration), a compressed video quality enhancement approach that features a novel Frame-Prediction Feature Transform (FPFT) module to process prediction information. Moreover, MDFI integrates a multi-domain feature fusion strategy that effectively combines spatiotemporal characteristics, cross-frequency representations, and compressed-domain prediction information to enhance decoded video quality. Additionally, we introduce a comprehensive dataset that encompasses uncompressed video sequences, corresponding reconstructed versions at multiple QP levels, and predicted frames generated from H.266/VVC compressed bitstreams, providing essential resources for developing and benchmarking video enhancement approaches. Extensive experiments demonstrate that our MDFI approach achieves superior performance to state-of-the-art methods in both objective metrics and visual quality, effectively mitigating video compression artifacts. The code is available at: https://github.com/dangdinh17/MDFI.git.

0.75
2

Flow Matching-Based PET Image Reconstruction

eess.IV cs.CVphysics.med-ph ·2026-08-20 ·Fumio Hashimoto, Ziqian Huang, Tatsuya Yokota, Kuang Gong
Abstract · 10 pages, 8 figures

Generative models have shown strong potential for positron emission tomography (PET) image reconstruction. Although diffusion model-based reconstruction methods have demonstrated promising performance, they often require many reverse sampling steps with data-consistency updates incorporated into the sampling process. Flow matching offers an attractive alternative because it can directly estimate clean images from intermediate states, allowing data-consistency refinement to be separated from flow propagation. In this work, we proposed flow matching-based PET image reconstruction methods. We first established PET-FlowDPS by incorporating Poisson likelihood guidance with an expectation-maximization (EM)-based preconditioner into the FlowDPS framework. We then proposed a model-based PET reconstruction method that used a pretrained flow matching model as a prior, in which the flow-based prior, PET data refinement, and stochastic propagation were interpreted within an approximate Bayesian framework. Experimental results using [$^{\text{18}}\text{F}$]FDG brain PET datasets showed that the proposed method achieved better bias-variance trade-offs across different dose levels compared with other reference methods. These results demonstrated the potential of flow matching as a generative prior for quantitative PET image reconstruction.

0.57
3

Multispectral Household Plastic Classification for Recycling Using a Camera Array

eess.IV ·2026-08-23 ·Katja Kossira, Jürgen Seiler, André Kaup
publishedcode/data
Abstract

Plastic pollution has become a persistent problem in natural ecosystems. Driven by insufficient waste management, limited recycling efficiency, and high costs for recycling, plastic waste in the environment poses significant ecological and health risks. Recycling requires accurate identification of polymer types, but existing optical sorting systems often struggle to distinguish common household plastics. In this work, we present a novel classification approach based on a multispectral imaging system consisting of nine cameras equipped with near-infrared bandpass filters. The system is designed to discriminate the seven most common household plastics. From the resulting multispectral images, we extract the spectral fingerprints and derive features such as intensity differences between specific wavelength pairs and their slopes, as well as false-color image representations. A dedicated preprocessing pipeline aligns and normalizes the data before classification. We recorded a multispectral household plastic database (https://github.com/FAU-LMS/MHPM) and trained four different classifiers Gradient Boosting, Extreme Gradient Boosting, Light Gradient Boosting Machine, and CatBoost. The best-performing model achieves a classification accuracy of 86.7%. The computational runtime is 2.603 μs per pixel, enabling efficient processing of high-resolution images. The entire setup is built from off-the-shelf hardware components, which makes replication straightforward and allows direct integration into industrial sorting pipelines.

0.56
4

Frozen CLIP Priors for Robust Self-Supervised Poisson Inverse Problems

eess.IV cs.CV ·2026-08-20 ·Laura C. Diaz-Delgado, Emmanuel Martinez, Henry Arguello
top venue
Abstract

Self-supervised learning for imaging inverse problems is increasingly important in photon-limited settings, where acquiring clean ground truth is impractical and reconstruction must remain stable under dataset and acquisition shifts. This challenge is amplified under Poisson noise, whose signal-dependent statistics interact with sampling operators (e.g., CFA mosaicing). Meanwhile, foundation vision encoders trained at web scale offer distortion-invariant, content-related representations that generalize well across domains, suggesting a promising route to build priors that transfer beyond the training distribution without expensive fine-tuning. This paper proposes an ADMM-inspired unrolled plug-and-play solver for Poisson inverse problems that decouples a closed-form data-consistency update from a parameter-efficient prior. The prior is implemented as a lightweight decoder operating on frozen CLIP RN50 dense multi-scale features, adapting foundation representations with less trainable parameters. For self-supervision, the method integrates GR2R measurement-domain re-corruption with an Equivariant Imaging regularizer via virtual acquisitions. Experiments on Poisson CFA demosaicing and deblurring show competitive quality, improved robustness under shifts, and self-supervised performance approaching supervised training.

0.54
5

Primitive Representation Learning for Unsupervised Dynamic Contrast Enhanced MRI Reconstruction

eess.IV cs.CVcs.LGeess.SP+1 ·2026-08-18 ·Veronika Spieker, Wenqi Huang, Cemre Ariyurek, Liam Timms, Daniel Rueckert +3 more
publishedcode/data
Abstract · Accepted at MICCAI Off-Grid Workshop 2026

Reliable quantitative analysis of dynamic contrast-enhanced MRI requires high-quality spatiotemporal reconstructions at high undersampling rates. Scan-specific reconstructions using Gaussian and Gabor primitives have shown promising results without the need for large training datasets, but have not addressed the additional dimension of dynamic contrast. We propose a multi-dimensional, primitive based framework for dynamic contrast-enhanced MRI reconstruction that disentangles the underlying anatomy, the dynamic contrast enhancement, and residual motion into separate temporal basis functions, thereby enabling a geometrical interpretation of the representation. We show that this architecture achieves performance competitive with conventional reconstruction methods, both in reconstruction quality and in the accuracy of extracted aorta and kidney enhancement curves. The modular tier design extends naturally to additional dynamic factors and higher acceleration rates. Code available at https://github.com/compai-lab/2026-GaborDCE-spieker.

0.51
6

BiCRVC: An Efficient Bidirectional Neural Video Compression Framework via Coupled Representation Coding

eess.IV ·2026-08-17 ·Wei Jiang, Junru Li, Kai Zhang, Li Zhang
Abstract · Fix some typos

Neural video compression (NVC) has achieved strong compression performance, but practical random-access coding still faces two technical challenges: existing bidirectional NVCs (BVCs) usually require costly motion-first decoding, and reliable motion estimation is difficult under long-range bidirectional prediction. To address these issues, we present BiCRVC, an efficient bidirectional neural video compression framework based on coupled representation coding. Instead of coding motion and frame information with two separate codecs, BiCRVC transforms the motion representation and the current-frame latent into a unified latent representation for entropy coding. This design enables motion and frame information to be decoded from the same bitstream with one unified codec, while still reconstructing motion-aligned contexts for frame decoding. To improve motion accuracy, we introduce multi-candidate motion estimation (MCME), which combines multi-scale motion estimation and parallel accumulated motion estimation to better handle diverse and long-range motions. To reduce motion coding overhead, we further propose bidirectional motion feature propagation (BMFP), which reuses previously decoded motion features at both the encoder and decoder as temporal priors for conditional motion coding. In addition, coupled distortion training and random GOP structure training are used to encourage joint motion-frame coding and improve adaptation to hierarchical random-access structures. Experiments show that BiCRVC achieves better compression performance than state-of-the-art BVCs while providing about 30 times faster 1080p decoding than recent BVCs.

0.49
7

Clinical Pathways Matter for Multimodal Deep Learning in Early Alzheimers Disease Detection

eess.IV ·2026-08-17 ·Yao Lu, Solveig Kristina Hammonds, Alvaro Fernandez-Quilez
published
Abstract · Published

Identifying individuals at risk of Alzheimer's disease (AD), particularly in the preclinical and early stages, remains challenging. Although deep learning approaches based on structural MRI show promise as a non-invasive biomarker, existing multimodal models require task-specific training and depend on biomarkers that are not routinely available in clinical practice. Here, we propose a zero-shot multimodal framework based on SigLIP that combines structural MRI embeddings with text embeddings of routinely collected clinical variables for early AD risk stratification in individuals at preclinical or mild cognitive impairment (MCI) stages. We evaluated the approach in 416 individuals from the ADNI cohort (age: 72.73 +- 6.7). SigLIP was used without fine-tuning to extract MRI and clinical text embeddings, which were combined into multimodal representations for individual-level AD risk prediction within 4 years. We further compared the model performance in a single-visit and two-visit settings to assess the value of longitudinal information and framework scalability. In the single-visit setting, combining MRI embeddings with MMSE, age, and sex achieved an AUC of 0.91 +- 0.02, outperforming both a CSF A\b{eta}42-based model (AUC 0.73 +- 0.08) and an MMSE-based model (AUC 0.85 +- 0.22). In the two-visit setting, performance was maintained or improved, supporting the scalability of the approach to longitudinal data. These findings suggest that zero-shot multimodal fusion of structural MRI and routinely collected clinical variables may provide a practical and scalable strategy for early AD risk stratification without task-specific retraining.

0.48
8

CHIMERA Challenge: Biochemical Recurrence Prediction in Prostate Cancer Patients using multimodal datasets

eess.IV cs.CV ·2026-08-21 ·Robert N. Spaans, Catherine Chia, Tongjie Wang, Adam Kowalewski, Parandzem Khachatryan +5 more
benchmark
Abstract · 38 pages, 3 figures, 3 supplementary figures. Preprint submitted to Medical Image Analysis. Challenge results presented at the CHIMERA works…

Biochemical recurrence (BCR), defined as any detectable prostate-specific antigen level after prostatectomy with confirmatory elevation, is widely used as a surrogate endpoint and typically assessed using clinical and pathological variables. Currently, no standardized benchmark exists for multimodal prognostic modeling in urological cancers, partly because curating heterogeneous multimodal data remains challenging. We developed the CHIMERA Challenge, a multimodal benchmark integrating preoperative mpMRI, post-prostatectomy histopathology, patient characteristics, and clinician-derived variables from 267 patients across two institutions. The dataset comprises 801 MRI sequences, 13 clinical variables per case, and 942 WSIs. Training (n=95), validation (n=23), and test (n=149) splits were established and hosted on the Grand Challenge platform. Baseline clinical and pathological characteristics did not differ significantly across splits. Models were evaluated on predicting time to BCR using the C-index. Post-challenge analyses tested how each model type performed when clinician-derived variables were withheld or randomized. Unimodal clinical models achieved the highest test C-index of 0.7402 but proved sensitive to the integrity of these variables, with performance collapsing toward chance (C approximately 0.50) when they were randomized. Multimodal models retained near-baseline performance when these variables were withheld (delta C at most 0.04), indicating their ability to recover prognostic signal directly from imaging data. CHIMERA is the first public, standardized multimodal benchmark for prostate cancer prognosis. Although models using only patient characteristics and clinician-derived variables yielded the highest leaderboard performance, multimodal models demonstrated greater robustness in clinically realistic scenarios where complete expert annotation is not guaranteed.

0.47
9

A cross-modal generative model for incomplete and degraded prostate MRI with multicentre clinical validation

eess.IV cs.AIcs.CV ·2026-08-17 ·Siyuan Ma, Liang He, Mengying Zhu, Yi Chai, Mengyao Lyu +12 more
published
Abstract

Missing or degraded sequences can limit prostate multiparametric MRI. We developed MSCNet, a sequence-conditioned cross-modal generative framework for reconstructing unavailable contrasts and restoring degraded acquisitions. Across ten completion tasks, task-specific MSCNet achieved mean structural similarity of 0.818 versus 0.798 for the strongest task-matched comparators; matched-capacity analyses showed larger differences in lesion fidelity and boundary preservation. In a blinded 1,000-case reader study, overall image quality met the prespecified non-inferiority criterion for DWI, ADC and T2W completion, but not T1W. In a separate 200-case diagnostic assessment, AUCs for clinically significant cancer were 0.860 with acquired images, 0.841 with MSCNet and 0.797 with baseline-generated images. A locked 186-case three-hospital cohort supported multicentre transportability. These retrospective results support quality-controlled cross-modal reconstruction as an adjunct to acquired prostate MRI.

0.47
10

SweepLSD: A One-Pass, O(width)-Memory Line Segment Detector with an Integer-Only Streaming Core and a Real-Time FPGA Realization

eess.IV cs.ARcs.CV ·2026-08-22 ·Yoshiyasu Shimizu
code/data
Abstract · 40 pages, 12 figures, 18 tables. Code, benchmarks, and evaluation harnesses (MIT): https://github.com/yosh-shimizu/sweeplsd

We present SweepLSD, a line segment detector that reads the image exactly once and emits each segment within a few rows of its last pixel passing the scan line. Every stage, including connected-component labeling and the final line test, processes the image as a row stream: intermediate memory is O(width) rather than O(pixels), and the per-pixel core is integer-only. We give the first complete description of the algorithm, designed in the author's 2014 master's thesis but never published, together with an open-source C++17 implementation and an FPGA realization -- held bit-exact against the software in its hardware configuration -- detecting segments in live 1080p30 video on 2009-era silicon without frame buffer or external memory. On structure-rich public 4K photographs downscaled to Full-HD, one CPU thread detects segments in ~11 ms -- 4.6x/5.2x/25x faster than the original authors' implementations of ELSED, EDLines, and LSD -- with the tightest frame-time distribution and the best per-segment direction accuracy of the four detectors, and curve rejection by design, while trailing ELSED in F-score on synthetic ground truth. A Manhattan-frame vanishing-point study on York Urban and NYU-VP scores every detector under a selection/evaluation-separated best-estimator-per-detector protocol, under which SweepLSD leads on NYU-VP by ~0.3 degrees and trails by 0.1 degrees on York Urban, with the fastest end-to-end pipeline of the four detectors on both. A single-frame camera-attitude application, evaluated on synthetic scenes with exact ground truth and on EuRoC and TUM-VI, matches the baselines' accuracy at a fraction of their memory, and drives a 4K horizon lock to 0.06 degrees median attitude error at 32 ms median per frame.

0.44