CS Paper Radar

A cross-modal generative model for incomplete and degraded prostate MRI with multicentre clinical validation

Siyuan Ma, Liang He, Mengying Zhu, Yi Chai, Mengyao Lyu, Haowei Wang, Qizhen Lan, HaoBo Sun, Qixin Zhang, Jingli Chen, Xiaobing Wei, Jiaming Liu, Guiqin Liu, Qianwen Zhang, Yang Liu, Dacheng Tao, Guangyu Wu

eess.IV cs.AIcs.CV ·submitted 2026-08-17 08:11 UTC · v1
published

Abstract

Missing or degraded sequences can limit prostate multiparametric MRI. We developed MSCNet, a sequence-conditioned cross-modal generative framework for reconstructing unavailable contrasts and restoring degraded acquisitions. Across ten completion tasks, task-specific MSCNet achieved mean structural similarity of 0.818 versus 0.798 for the strongest task-matched comparators; matched-capacity analyses showed larger differences in lesion fidelity and boundary preservation. In a blinded 1,000-case reader study, overall image quality met the prespecified non-inferiority criterion for DWI, ADC and T2W completion, but not T1W. In a separate 200-case diagnostic assessment, AUCs for clinically significant cancer were 0.860 with acquired images, 0.841 with MSCNet and 0.797 with baseline-generated images. A locked 186-case three-hospital cohort supported multicentre transportability. These retrospective results support quality-controlled cross-modal reconstruction as an adjunct to acquired prostate MRI.

Closest papers

Nearest neighbours by meaning across the whole index.

Conditional Diffusion-Based Generation of T2-Weighted Prostate MRI for Clinically Significant Prostate Cancer Classification

cs.CV ·2026-11-01 ·Xavier Rafael-Palou, Alejandro Vergara-Richart, Ignacio Iborra Roncales, Carmen Prieto-de-la-Lastra, Andreu Antolin-Redondo +2 more
similarity 0.70
Abstract

Scarce and unrepresentative training data limit the performance of prostate MRI prediction models. Synthetic T2-weighted (T2W) MRI may augment training data containing clinically significant prostate cancer (csPCa) and transition zone (TZ) lesions. In this retrospective, single-center, ethics-committee-approved study, we developed a conditional generative model for T2W prostate MRI extending MAISI-v2 with csPCa class, zonal, and lesion-mask-guided conditioning, incorporating a relative advantage weighted loss fine-tuned on 1,303 patients (1,654 lesions). Fidelity was assessed by incremental ablation, and downstream utility was evaluated with T2W-based csPCa classifiers across five simulated training-data scenarios, each testing 18 synthetic-data configurations. The proposed model reduced Fréchet inception distance (FID) from 13.28 (pretrained MAISI-v2) to $2.04 \pm 0.06$ internally (PI-CAI: $3.83 \pm 0.51$). Synthetic augmentation significantly increased AUC in all five scenarios (+0.027 to +0.088; adjusted $p = 0.016$--$0.043$), though cross-institutional augmentation of PI-CAI yielded a non-significant gain (+0.013; $p = 0.397$). Overall, our model improved T2W MRI fidelity, and synthetic images improved csPCa classification under simulated data constraints, although benefit did not transfer significantly across institutions.

0.21

Distortion-Free High-Resolution PROPELLER-DWI: Technical Advances and Initial Demonstration for the Prostate

eess.IV ·2026-10-04 ·Jingjia Chen, Kun Zhou, Haoyang Pei, Angela Tong, Sherif Elsherif +5 more
similarity 0.67
Abstract · 37 pages, 10 figures

Purpose: To develop and evaluate an integrated acquisition and reconstruction framework for distortion-free, high-resolution prostate diffusion-weighted imaging (DWI). Methods: PROPELLER-DWI combines pulsed-gradient spin-echo diffusion preparation, an interleaved gradient-and-spin-echo PROPELLER acquisition with golden-angle blade rotation, and self-supervised joint reconstruction and denoising. It was compared with conventional NUFFT reconstruction and MPPCA denoising in a NIST/QIBA diffusion phantom, 25 volunteers, and 4 clinical patients undergoing 3T prostate MRI across three spatial-resolution settings and two b-values (50 and 1000 s/mm2). Reader studies compared geometric fidelity, image quality, and overall preference with clinical single-shot EPI-DWI. Results: PROPELLER-DWI preserved prostate geometry in cases where EPI-DWI showed susceptibility-induced distortion, signal loss, and metal-related artifacts. Self-supervised reconstruction improved noise suppression, with the greatest benefit at higher spatial resolution. Across all resolutions, PROPELLER-DWI had significantly higher geometric fidelity than EPI-DWI, and radiologist preference increased with the severity of EPI distortion. ADC measurements remained consistent across resolutions and comparable to clinical EPI-DWI, whereas EPI-DWI ADC varied with increasing resolution. Retrospective reduced-shot reconstruction also supported shorter scan times. Conclusion: PROPELLER-DWI enables distortion-free, high-resolution prostate DWI while preserving quantitative diffusion measurements, providing a practical alternative for technically challenging prostate MRI and applications requiring improved geometric fidelity.

0.24

Technically Plausible but Clinically Misleading? Expert Evaluation of Patient-Personalized Synthetic Prostate MRI

eess.IV ·2026-08-17 ·Gabriel Paulo Maglalang Israel, Sol Gedde, Alvaro Fernandez-Quilez
published similarity 0.67
Abstract · To appear in SCAI 2026 proceedings

Magnetic resonance imaging (MRI) is central to prostate cancer assessment, yet its acquisition is costly and time-consuming, making it a major bottleneck in the patient care pathway. Personalized MRI synthesis is a promising direction because it may allow the generation of clinically realistic images tailored to individual patients while reducing the dependence on scanner-acquired imaging. In this work, we in-vestigate whether patient-personalized MRI synthesis produces images that experts perceive as clinically plausible and how such personaliza-tion influences expert interpretation. We synthesize patient-personalized prostate MRI using a 3D diffusion model conditioned on routine pre-imaging clinical variables age and PSA. Using a large publicly available dataset, we first verify that synthesized images are technically compara-ble to scanner-acquired MRIs using standard image similarity metrics. We then conduct a pilot, single-blinded, randomized expert study on a subset of cases sampled to reflect variation in patient clinical pro-files. A radiologist compared personalized and unconditioned synthetic MRIs using paired assessments and Likert-scale ratings of clinical plausibility, confidence, and risk of misleading interpretation, supplemented by qualitative feedback. Although personalized synthetic MRIs appeared technically plausible, expert interpretation highlighted variability in con-fidence and potential risks of misleading cues when routine clinical data was embedded into image generation. These findings suggest that while personalized synthesis may be technically feasible, careful assessment is needed to understand how generated cues influence clinician interpreta-tion before such systems can be safely integrated into clinical workflows.

0.33

MOSAIC-Flow: Orthogonal-Axis and Status-Conditioned Fusion for Missing-Sequence Completion in Brain Tumor MRI

cs.CV ·2026-10-29 ·Pengli Zhu, Zhihao Peng, Yixuan Yuan
code/data similarity 0.66
Abstract · 5 pages, 4 figures

Missing-sequence completion is important for comprehensive brain tumor characterization, but cross-modal fusion can obscure sequence-specific contrast and lose fine-grained three-dimensional tumor detail. To address this challenge, we introduce Modality-aware Orthogonal-axis Status-conditioned Attentive Integration for Completion (MOSAIC-Flow), a unified framework for missing-sequence completion that learns a target-conditioned velocity field while keeping the seven acquired volumes fixed throughout the transport. Specifically, modality-aware stems independently encode each sequence, and orthogonal-axis refinement captures axial, coronal, and sagittal dependencies while retaining the three-dimensional representation. Status-conditioned prototype fusion uses compact modality and availability tokens to route and modulate pooled queries from the fused visual representation, enabling target-adaptive conditioning without dense voxel-to-voxel attention. A conditional flow matching objective transports target-channel noise toward the single missing sequence, while four Heun trajectories are averaged to produce the completion. Evaluation across structural, diffusion, and contrast-enhanced MRI in UCSF-PDGM demonstrates consistent whole-brain and tumor-region fidelity across all eight single-target completion tasks, with the strongest performance on structural sequences. Code is available at https://github.com/CUHK-AIM-Group/MOSAIC-FLOW.

0.21

C-WFDM: A ControlNet-Guided Wavelet-Fusion Diffusion Model for Multimodal Brain MRI Completion

cs.CV ·2026-11-03 ·Muhammad Nabi Yasinzai, Remika Mito, Mangor Pedersen
similarity 0.64
Abstract

Multimodal brain MRI provides complementary anatomical, tissue, and pathological information to support downstream artificial intelligence (AI) applications. However, modality availability is uneven across public and pooled neuroimaging datasets: T1-weighted (T1w) MRI is widely represented, T2-weighted (T2w) and fluid-attenuated inversion recovery (FLAIR) MRI are less consistently available, and gadolinium-enhanced T1-weighted (T1Gd) MRI is relatively scarce. Pooled datasets therefore contain participants with different combinations of acquired MRI contrasts, reflecting variation in the study designs, acquisition protocols, and clinical or research objectives of the contributing studies. Many missing-modality benchmarks simulate incomplete MRI by withholding contrasts from complete four-modality cases, which may not represent the observed availability patterns in pooled datasets. To address this gap, we introduce C-WFDM, a ControlNet extension of our Wavelet-Fusion Diffusion Model (WFDM), for subject-specific missing-modality completion. C-WFDM is built on an earlier BrainScape snapshot comprising 157 public MRI datasets and 45,880 preprocessed scans. The pretrained WFDM backbone retains target-modality and metadata conditioning, while target-specific ControlNet adapters use MRI contrasts from the same participant to guide synthesis. C-WFDM synthesizes T2w from T1w, FLAIR from T1w and T2w, and T1Gd from T1w, T2w, and FLAIR. Acquired conditioning contrasts are used when available, and generated intermediate contrasts are used only when required. We compare C-WFDM with ALDM, cWDM, and Pix2Pix using paired structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and mean absolute error (MAE). In the BrainScape completion experiment, C-WFDM achieves the best T2w and FLAIR results among the evaluated models, with SSIM values of 0.9232 and 0.8904, respectively.

0.26

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.64
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

End-to-end prostate lesion segmentation and detection from undersampled diffusion-weighted MRI

cs.CV physics.med-ph ·2026-10-24 ·Lukas T. Rotkopf, Marco Schlimbach, Kevin Kröninger, Stefan O. Schoenberg, Heinz-Peter Schlemmer +2 more
similarity 0.63
Abstract

Automated prostate lesion detection from diffusion-weighted MR imaging (DWI) conventionally relies on reconstructed images and does not fully use all acquisition information. We present an end-to-end network that uses complex multicoil DWI data and coil sensitivity information for prostate lesion segmentation. We included 269 fastMRI prostate examinations with additional voxel-level lesion annotations. Of these, 64 examinations contained PIRADS 4 or 5 lesions. The proposed network, VarNet-Seg, consists of a k-space variational network (VarNet) with six variational cascades and an image-space 3D segmentation U-Net. Comparator models used the same segmentation architecture with fully coil-combined images (CC-Seg), fixed root-sum-of-squares reconstruction (RSS-Seg), or fixed SENSE reconstruction (SENSE-Seg). We performed ablations with end-to-end training and data consistency (DC) enabled or disabled. We evaluated lesion segmentation using Dice and patient-level detection using AUROC in five-fold cross-validation with full sampling, simulated undersampling, added noise, or both. VarNet-Seg achieved the highest Dice at every undersampling level. At eight-fold acceleration, Dice was 0.22 for VarNet-Seg, 0.14 for SENSE-Seg and 0.16 for VarNet-Seg (no DC). The paired difference from SENSE-Seg was 0.08 (95% CI, 0.04-0.11). With full sampling, VarNet-Seg and RSS-Seg performed similarly (0.40 vs 0.39). Patient-level AUROC decreased from 0.75 with full sampling to 0.63 at eight-fold acceleration; corresponding RSS-Seg AUROCs were 0.76 and 0.64. The proposed multicoil network improved prostate lesion segmentation under simulated undersampling compared to conventional models. Matched ablations supported contributions from both end-to-end training and data consistency. Prospective evaluation is needed to establish whether this approach can be used clinically in accelerated prostate DWI.

0.31

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.62
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.

0.18