Distortion-Free High-Resolution PROPELLER-DWI: Technical Advances and Initial Demonstration for the Prostate

Jingjia Chen, Kun Zhou, Haoyang Pei, Angela Tong, Sherif Elsherif, Luke Ginocchio, Mahesh Bharath Keerthivasan, Qiuting Wen, Hersh Chandarana, Li Feng

eess.IV ·submitted 2026-10-04 18:07 UTC · v1

Abstract

Purpose: To develop and evaluate an integrated acquisition and reconstruction framework for distortion-free, high-resolution prostate diffusion-weighted imaging (DWI). Methods: PROPELLER-DWI combines pulsed-gradient spin-echo diffusion preparation, an interleaved gradient-and-spin-echo PROPELLER acquisition with golden-angle blade rotation, and self-supervised joint reconstruction and denoising. It was compared with conventional NUFFT reconstruction and MPPCA denoising in a NIST/QIBA diffusion phantom, 25 volunteers, and 4 clinical patients undergoing 3T prostate MRI across three spatial-resolution settings and two b-values (50 and 1000 s/mm2). Reader studies compared geometric fidelity, image quality, and overall preference with clinical single-shot EPI-DWI. Results: PROPELLER-DWI preserved prostate geometry in cases where EPI-DWI showed susceptibility-induced distortion, signal loss, and metal-related artifacts. Self-supervised reconstruction improved noise suppression, with the greatest benefit at higher spatial resolution. Across all resolutions, PROPELLER-DWI had significantly higher geometric fidelity than EPI-DWI, and radiologist preference increased with the severity of EPI distortion. ADC measurements remained consistent across resolutions and comparable to clinical EPI-DWI, whereas EPI-DWI ADC varied with increasing resolution. Retrospective reduced-shot reconstruction also supported shorter scan times. Conclusion: PROPELLER-DWI enables distortion-free, high-resolution prostate DWI while preserving quantitative diffusion measurements, providing a practical alternative for technically challenging prostate MRI and applications requiring improved geometric fidelity.

Comment
37 pages, 10 figures

Closest papers

Nearest neighbours by meaning across the whole index.

A cross-modal generative model for incomplete and degraded prostate MRI with multicentre clinical validation

eess.IV cs.AIcs.CV ·2026-08-17 ·Siyuan Ma, Liang He, Mengying Zhu, Yi Chai, Mengyao Lyu +12 more
published similarity 0.67
Abstract

Missing or degraded sequences can limit prostate multiparametric MRI. We developed MSCNet, a sequence-conditioned cross-modal generative framework for reconstructing unavailable contrasts and restoring degraded acquisitions. Across ten completion tasks, task-specific MSCNet achieved mean structural similarity of 0.818 versus 0.798 for the strongest task-matched comparators; matched-capacity analyses showed larger differences in lesion fidelity and boundary preservation. In a blinded 1,000-case reader study, overall image quality met the prespecified non-inferiority criterion for DWI, ADC and T2W completion, but not T1W. In a separate 200-case diagnostic assessment, AUCs for clinically significant cancer were 0.860 with acquired images, 0.841 with MSCNet and 0.797 with baseline-generated images. A locked 186-case three-hospital cohort supported multicentre transportability. These retrospective results support quality-controlled cross-modal reconstruction as an adjunct to acquired prostate MRI.

0.47

Technically Plausible but Clinically Misleading? Expert Evaluation of Patient-Personalized Synthetic Prostate MRI

eess.IV ·2026-08-17 ·Gabriel Paulo Maglalang Israel, Sol Gedde, Alvaro Fernandez-Quilez
published similarity 0.64
Abstract · To appear in SCAI 2026 proceedings

Magnetic resonance imaging (MRI) is central to prostate cancer assessment, yet its acquisition is costly and time-consuming, making it a major bottleneck in the patient care pathway. Personalized MRI synthesis is a promising direction because it may allow the generation of clinically realistic images tailored to individual patients while reducing the dependence on scanner-acquired imaging. In this work, we in-vestigate whether patient-personalized MRI synthesis produces images that experts perceive as clinically plausible and how such personaliza-tion influences expert interpretation. We synthesize patient-personalized prostate MRI using a 3D diffusion model conditioned on routine pre-imaging clinical variables age and PSA. Using a large publicly available dataset, we first verify that synthesized images are technically compara-ble to scanner-acquired MRIs using standard image similarity metrics. We then conduct a pilot, single-blinded, randomized expert study on a subset of cases sampled to reflect variation in patient clinical pro-files. A radiologist compared personalized and unconditioned synthetic MRIs using paired assessments and Likert-scale ratings of clinical plausibility, confidence, and risk of misleading interpretation, supplemented by qualitative feedback. Although personalized synthetic MRIs appeared technically plausible, expert interpretation highlighted variability in con-fidence and potential risks of misleading cues when routine clinical data was embedded into image generation. These findings suggest that while personalized synthesis may be technically feasible, careful assessment is needed to understand how generated cues influence clinician interpreta-tion before such systems can be safely integrated into clinical workflows.

0.33

Conditional Diffusion-Based Generation of T2-Weighted Prostate MRI for Clinically Significant Prostate Cancer Classification

cs.CV ·2026-11-01 ·Xavier Rafael-Palou, Alejandro Vergara-Richart, Ignacio Iborra Roncales, Carmen Prieto-de-la-Lastra, Andreu Antolin-Redondo +2 more
similarity 0.64
Abstract

Scarce and unrepresentative training data limit the performance of prostate MRI prediction models. Synthetic T2-weighted (T2W) MRI may augment training data containing clinically significant prostate cancer (csPCa) and transition zone (TZ) lesions. In this retrospective, single-center, ethics-committee-approved study, we developed a conditional generative model for T2W prostate MRI extending MAISI-v2 with csPCa class, zonal, and lesion-mask-guided conditioning, incorporating a relative advantage weighted loss fine-tuned on 1,303 patients (1,654 lesions). Fidelity was assessed by incremental ablation, and downstream utility was evaluated with T2W-based csPCa classifiers across five simulated training-data scenarios, each testing 18 synthetic-data configurations. The proposed model reduced Fréchet inception distance (FID) from 13.28 (pretrained MAISI-v2) to $2.04 \pm 0.06$ internally (PI-CAI: $3.83 \pm 0.51$). Synthetic augmentation significantly increased AUC in all five scenarios (+0.027 to +0.088; adjusted $p = 0.016$--$0.043$), though cross-institutional augmentation of PI-CAI yielded a non-significant gain (+0.013; $p = 0.397$). Overall, our model improved T2W MRI fidelity, and synthetic images improved csPCa classification under simulated data constraints, although benefit did not transfer significantly across institutions.

0.21

CONTEXT-PCa: Evaluating the role of clinical context in MRI-based AI for detecting clinically significant prostate cancer (study protocol)

cs.AI ·2026-11-14 ·Shiqi Huang, Weixi Yi, Shaheer Ullah Saeed, Yipei Wang, Wen Yan +7 more
similarity 0.59
Abstract

The objective of this study is to investigate the role of clinical variables - their breadth, source, and quality - in the development, utility, and generalisability of an AI system for bi-parametric MRI (bpMRI)-based diagnosis of clinically significant prostate cancer (csPCa). Clinical context is added to the published PI-CAI-2B image-only model, whose weights are fixed. The study cohort comprises 6,022 biparametric MRI cases from 4,540 patients at University College London Hospitals NHS Foundation Trust (2019-2024), of which 4,834 cases (3,632 patients) are held out for internal testing. Forty-three clinical variables are drawn from structured health records, clinical letters, MRI reports, and automated image measurements. The primary endpoint is the difference in the area under the receiver operating characteristic curve (AUROC) between the image-context and image-only models on the internal test set. Secondary analyses compare combining strategies, the contribution of individual variables, and performance across subgroups. All models are further tested on five external cohorts from primary diagnosis and population-based screening.

0.20

Diffusion-Based Synthesis of Complete 3D Biparametric Prostate MRI

cs.CV ·2026-10-22 ·Claudia Giardina, Montse Pardàs, Verónica Vilaplana
publishedhot direction similarity 0.59
Abstract · Presented at the 6th Deep Generative Models Workshop (DGM4MICCAI), MICCAI 2026

Synthetic biparametric MRI (bpMRI) may help alleviate the limited availability of large and representative prostate MRI datasets for deep learning applications. In this work, we present a conditional 3D diffusion framework for anatomy-conditioned synthesis of complete prostate bpMRI from anatomical masks. The framework supports sequential synthesis, in which T2w and diffusion modalities are generated by separately trained models, and joint synthesis, in which all bpMRI modalities are generated simultaneously within a single model. Five configurations were trained using PI-CAI, FastMRI Prostate, and PROSTATEx datasets to investigate different conditioning schemes, target modalities, and synthesis strategies. Evaluation using distribution-based metrics, paired-image similarity, and qualitative assessment demonstrated the feasibility of both synthesis pathways. Joint synthesis achieved competitive distributional fidelity while generating complete bpMRI, whereas direct synthesis of ADC and computed high-b-value DWI outperformed their derivation from synthetic diffusion-weighted images.

0.34

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.57
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation

cs.CV cs.LG ·2026-08-14 ·Ayusha Abbas, Saram Abbas, Kabita Adhikari
similarity 0.57
Abstract

Prostate cancer claims a life every 80 seconds. Early detection is needed to prevent disease progression, and both PSA density calculation and biopsy decisions rely on knowing the exact boundary of the gland. Conventional ultrasound at 6-12 MHz blurs this boundary, missing one in three high-risk cancers. Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall; given the same image, two clinicians draw outlines differing by over 10% in area. Supervised methods are costly and generalise poorly across scanners. Can a foundation model segment the prostate with no training data? We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images, localises the prostate; we then apply CLAHE to sharpen the outer wall, binary dilation to recover missed pixels, and Fourier smoothing (4 modes, s=1.05) to refine the boundary. MedSAM requires a spatial prompt, so we evaluate bounding-box and point-click strategies across 75 patients of the Micro-Ultrasound Prostate Segmentation dataset (2,621 slices). On the 20-patient held-out test set, the pipeline reduces mean boundary-distance error by 45% (Dice 0.749+/-0.043 to 0.865+/-0.029; HD95 217.2+/-36.9 to 120.1+/-26.1 px), reaching Dice 0.859 across the cohort. Its mean overlap shows no significant difference from the three non-expert rater groups (p>0.19), while segmenting 38-52% more consistently (lower inter-patient standard deviation). Point-click prompts fail regardless of placement (best Dice=0.350), because speckle gives no stable local contrast. Only an approximate bounding box is required, so any clinic can deploy it without data collection, annotation, or retraining.

0.04

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
similarity 0.56
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.24