CS Paper Radar

Daily listing

2026-08-27 · eess.IV

7 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 5

CARDINAL Predicts Cardiovascular Risk From Non-contrast Cardiac CT

eess.IV cs.AIcs.CVcs.LG+1 ·2026-08-27 ·Roy Gabriel, Nattakorn Kittisut, Jamshid Hassanpour, Michael Galarnyk, Abanoub Abdelmalak +4 more
Abstract

Cardiovascular risk prediction remains limited by incomplete clinical data and imaging biomarkers that reduce computed tomography (CT) to a small number of handcrafted features. We developed CARDINAL (Cardiovascular Assessment via Representation learning from Deep Imaging with Nested Anatomical Latent embeddings), a clinically grounded framework that learns compact representations from routine non-contrast cardiac CT for major adverse cardiovascular event (MACE) prediction. In 17,659 patients, CARDINAL was evaluated for 1-, 3-, 5-, and 10-year MACE prediction against American Heart Association (AHA) pooled cohort equations (PCE), AHA predicting risk of cardiovascular disease events (PREVENT), coronary artery calcium (CAC), segmentation-derived CT biomarkers, and 70-feature structural radiomics. Gains were largest at longer horizons. At 10 years, CARDINAL (joint) achieved an area under the receiver operating characteristic curve (AUROC) of 0.866 $\pm$ 0.020 and an area under the precision-recall curve (AUPRC) of 0.890 $\pm$ 0.015, compared with an AUROC of 0.826 $\pm$ 0.023 and an AUPRC of 0.826 $\pm$ 0.022 for structural radiomics, the strongest baseline. CARDINAL also achieved the highest survival concordance index (C-index), 0.753 $\pm$ 0.015, and high-versus-low risk-tertile hazard ratio, 10.78 $\pm$ 3.16, with favorable reclassification and exploratory calibration. These findings suggest that non-contrast cardiac CT contains prognostic information beyond conventional risk equations, CAC scoring, and engineered imaging biomarkers.

0.45

Enhancing MRI Brain Tumor Edge Detection: A Hybrid Preprocessing Approach Utilizing CLAHE

eess.IV cs.CV ·2026-08-27 ·Shahid-E-Kaiser Md. Tashrif, Munshi Md Arafat Hussain, Sheikh Nahian, Sumaiya Islam
benchmarkhot direction
Abstract · 14 pages, 3 figures. In review at IntSym 2026, South Eastern University of Sri Lanka

Accurate boundary delineation of brain tumors in Magnetic Resonance Imaging (MRI) is a critical yet formidable challenge in neuro-oncology due to inherent scanner noise, complex anatomical structures, and uneven illumination. Traditional edge detection algorithms, while computationally lightweight and mathematically interpretable, frequently fail to capture the diffuse, localized boundaries of edema when relying solely on global preprocessing and manual parameter tuning. To overcome these limitations, we propose a hybrid automated edge detection pipeline. Our approach integrates an optimally configured Contrast-Limited Adaptive Histogram Equalization (CLAHE) layer into a comprehensive morphological preprocessing framework, followed by a deterministic sequential parameter sweep to fully automate threshold selection. The proposed hybrid model demonstrated enhancement in detecting critical anatomical structures in a publicly available benchmark database from Kaggle. By intelligently amplifying localized gradients without overwhelming the image with background noise, our method achieved higher Recall (Sensitivity). Consequently, the overall F1-Score elevated, and the Structural Similarity Index (SSIM) improved, all while maintaining a highly efficient execution. This establishes our optimized pipeline as a highly practical and near real-time operational model for clinical diagnostics, offering a compelling alternative to computationally heavy deep learning approaches.

0.34

Anatomy-Guided Foundation Model Adaptation with Within-Case Prototype Supervision for Standard Plane Detection in Fetal Ultrasound Blind Sweeps

cs.CV eess.IV ·2026-08-27 ·Yuzhe Zhao
benchmark
Abstract

Detecting the fetal abdominal circumference standard plane in low-cost obstetric blind sweeps is a highly imbalanced frame-classification problem: positive frames account for under 3% of a sequence, form short contiguous segments, and are poorly handled by off-the-shelf ultrasound and vision foundation models. We propose AnatoProto, a lightweight sequence-level framework that adapts a frozen BiomedCLIP encoder to fetal blind sweeps through four components: (i) anatomy-weighted spatial pooling that uses nnU-Net abdominal-region probabilities as a spatial prior to reweight BiomedCLIP patch tokens, so frozen semantic features are aggregated onto anatomically meaningful regions; (ii) a within-case prototype loss that pulls each frame embedding toward the mean of positive frames of the same sweep, exploiting case-level structure unavailable at the frame level; (iii) a three-stage cascade refinement (frame->segment->case-level rejecter) that lifts the prediction unit from noisy frames to structurally-constrained segments; and (iv) a hybrid prediction head that jointly models per-frame stability and inter-frame boundary transitions to suppress boundary false positives. On the ACOUSLIC-AI benchmark, AnatoProto reaches a test F1 of 67.72, outperforming the strongest foundation-model baseline (FetalCLIP + PRS, F1 = 54.52) by +13.20 F1 and the strongest video temporal-action-detection baseline (TriDet + PRS) by +15.76 F1. A synergy study, backed by embedding geometry and paired-bootstrap confidence intervals, shows that the prototype loss and anatomy-weighted pooling are not additive: applied alone the prototype loss reduces recall by 12 points, but combined with anatomy-weighted pooling it increases recall by 6.5 points -- a sign-flip we trace to the accuracy of the within-case prototype.

0.31

Destroy Me: Automatic Artifact Generation for Histopathology Images

eess.IV cs.AIcs.CVcs.LG ·2026-08-27 ·Zuzanna Krawczyk-Borysiak, Adam Krawczyk, Mateusz Miller, Gabriela Kaczmarek, Sławomir Pakuło +2 more
Abstract

Deep learning's diagnostic utility in pathology is constrained by model vulnerability to real-world data imperfections. While current strategies favor "perfect data" by filtering low-quality regions, which can lead to the loss of valuable diagnostic context, we propose a paradigm shift: engineering models to thrive in imperfect environments using "Destroy Me", a hybrid framework for realistic artifact synthesis and robust data augmentation. Our approach combines Stable Diffusion, fine-tuned to preserve morphological continuity by realistically integrating artifacts with the underlying tissue architecture, with physics-based procedural modeling to synthesize six common artifact types: tissue folds, precipitates, blur, stitching errors, dust, and pen markers. Artifact fidelity is assessed using Kernel Inception Distance (KID) and color Wasserstein distance metrics. Validating this strategy on lung adenocarcinoma pattern classification with an nnU-Net, we confirm that models trained on "destroyed" patches consistently outperform baselines on independent real-world datasets. Specifically, we observed a 10.5% relative improvement in macro F1-score and a 15% relative increase in the Cohen's Kappa ($κ$) coefficient. Crucially, our results demonstrate that selective, impact-weighted augmentation is vital for balancing practical robustness with the preservation of subtle diagnostic features.

0.23

Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration Accuracy

eess.IV cs.CV ·2026-08-27 ·Hengjie Liu, Manju Sharma, Xinyi Fu, Di Xu, Ke Sheng
benchmark
Abstract

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

0.21