CS Paper Radar

Anatomy-Guided Foundation Model Adaptation with Within-Case Prototype Supervision for Standard Plane Detection in Fetal Ultrasound Blind Sweeps

Yuzhe Zhao

cs.CV eess.IV ·submitted 2026-08-27 12:36 UTC · v1
benchmark

Abstract

Detecting the fetal abdominal circumference standard plane in low-cost obstetric blind sweeps is a highly imbalanced frame-classification problem: positive frames account for under 3% of a sequence, form short contiguous segments, and are poorly handled by off-the-shelf ultrasound and vision foundation models. We propose AnatoProto, a lightweight sequence-level framework that adapts a frozen BiomedCLIP encoder to fetal blind sweeps through four components: (i) anatomy-weighted spatial pooling that uses nnU-Net abdominal-region probabilities as a spatial prior to reweight BiomedCLIP patch tokens, so frozen semantic features are aggregated onto anatomically meaningful regions; (ii) a within-case prototype loss that pulls each frame embedding toward the mean of positive frames of the same sweep, exploiting case-level structure unavailable at the frame level; (iii) a three-stage cascade refinement (frame->segment->case-level rejecter) that lifts the prediction unit from noisy frames to structurally-constrained segments; and (iv) a hybrid prediction head that jointly models per-frame stability and inter-frame boundary transitions to suppress boundary false positives. On the ACOUSLIC-AI benchmark, AnatoProto reaches a test F1 of 67.72, outperforming the strongest foundation-model baseline (FetalCLIP + PRS, F1 = 54.52) by +13.20 F1 and the strongest video temporal-action-detection baseline (TriDet + PRS) by +15.76 F1. A synergy study, backed by embedding geometry and paired-bootstrap confidence intervals, shows that the prototype loss and anatomy-weighted pooling are not additive: applied alone the prototype loss reduces recall by 12 points, but combined with anatomy-weighted pooling it increases recall by 6.5 points -- a sign-flip we trace to the accuracy of the within-case prototype.

Closest papers

Nearest neighbours by meaning across the whole index.

FETALFusion: Resolution-Aware State-Space Modeling for Multi-Domain Fetal Head Segmentation

cs.CV cs.AI ·2026-10-13 ·Ammar Bhilwarawala, Mainak Bandyopadhyay
published similarity 0.68
Abstract · Accepted at the 15th International Conference on Image Processing Theory, Tools and Applications, 2026

Head circumference (HC) measured from 2D ultrasound is a routine marker of fetal growth, and automating it needs segmentations whose boundaries hold up on individual scans, not only on average. We present FETALFusion, a dual-path CNN-Mamba encoder-decoder for fetal head segmentation across acquisition types. It applies four-directional state-space scans only at the two highest-resolution stages, routes bottleneck features through domain-specific channel gates that are averaged at test time, and adds a weak landmark shape prior. We train jointly on transabdominal (HC-18) and transperineal (PSFHS) images and compare ten methods on a held-out test set of 471 images, each trained under one schedule and scored by surface distances at native resolution. FETALFusion reaches a Dice score of 0.963 and an HD95 of 2.10 mm without test-time augmentation or a domain label. It improves on U-Mamba on all five reported metrics (HD95 reduced by 0.31 mm; Holm-corrected ($p < 10^{-4}$), a lead that holds under test-time augmentation and across two independent training runs, and in the mean on U-Net, Attention U-Net and TransUNet. Residual encoders close the gap: a ResNet-34 UNet++ exceeds FETALFusion, and an ImageNet initialised ResNet-34 U-Net is best overall (HD95 1.75 mm). The ablation agrees. Calibrated against run-to-run variation, it attributes FETALFusion's measurable gains to the landmark shape prior and, on transperineal images, to the domain gates, while removing the state-space branch does not measurably change accuracy. HC from the predicted masks agrees with the clinical reference at an intraclass correlation of 0.9986.

0.34

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.67
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.63
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.63
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

Leveraging Segmentation Representations for Efficient Classification: A Self-Configuring Framework Based on nnU-Net

cs.CV cs.AI ·2026-11-17 ·Renjun Cai, Antonio Javier Gallego, Félix Fuentes-Hurtado
benchmark similarity 0.63
Abstract

We propose a self-configuring framework that extends the nnU-Net workflow to both segmentation and classification in 3D medical imaging. Building on nnU-Net's self-configuring method, the framework reuses representations learned by a segmentation model for image-level classification. Its encoder features and predicted segmentation probabilities are used by a lightweight classifier. Two information-sharing strategies are investigated. In the frozen-backbone branch, features are augmented with region-of-interest information, predicted foreground volume, and segmentation confidence. In the adaptation branch, the final encoder stage is partially fine-tuned for classification, with an auxiliary segmentation loss to preserve segmentation-related information. Additional five-fold experiments showed that more complex configurations did not consistently improve classification performance. On the public validation leaderboard, our selected framework achieved an Overall score of 0.8056. In the official FLARE 2026 Task 2 final evaluation, our framework ranked first overall, achieving the highest DSC, NSD, and AUROC across all four testing tasks, including two hidden testing tasks. Local inference measurements also remained below the challenge limits of $60 \mathrm{s}$ per case and $4 \mathrm{GB}$ GPU memory. These results demonstrate the practical value of reusing segmentation representations for classification while maintaining a simple and efficient framework.

0.13

Scribble Once, Segment the Sequence: Bidirectional Temporal Consistency for Weakly Supervised Segmentation in Echocardiography Sequences

eess.IV cs.CV ·2026-11-16 ·Vincent Li Weixin, Chen Jingkun, Vicente Grau
similarity 0.62
Abstract

Temporal medical image segmentation relies on pixel-wise annotations, which are prohibitively expensive for long image sequences. Existing weakly-supervised methods reduce the annotation burden per frame but still require repeated annotations across the sequence. Furthermore, sparse supervision can result in temporally unstable representations. Addressing both challenges requires a model that can leverage strong spatial priors from large-scale pretraining while minimizing reliance on dense annotations. Frozen 2D vision foundation models provide a promising basis for this by offering transferable spatial representations with low trainable parameters. However, their lack of explicit temporal modeling limits their ability to propagate reliable information across anatomical sequences. To address this, we present a weakly-supervised framework for temporal segmentation from a single scribble-annotated frame, with all remaining frames left unlabeled. The framework combines parameter-efficient adaptation of DINOv3 encoders present in the mean-teacher architecture. Furthermore, a set of complementary losses, including a temporal loss helps generate reliable segmentation priors for the unlabeled frames. This formulation decouples annotation costs from sequence length while retaining the transferable spatial knowledge of the pretrained encoder. Extensive experiments on the publicly available CAMUS and CardiacNet datasets demonstrate that our approach outperforms other scribble-supervised methods. These results show that accurate and temporally consistent segmentation can be achieved from extremely sparse supervision, substantially reducing annotation requirements for temporal echocardiographic segmentation and providing a practical framework for scalable clinical deployment.

0.16

Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry

cs.CV cs.LG ·2026-11-02 ·Moein Heidari, Junbo Rao, Yudan Chen, Yasamin Medghalchi, River Jiang +4 more
code/data similarity 0.62
Abstract

**Purpose:** Ultrasound biometry is widely used across various clinical applications, including prenatal and cardiac examinations, to obtain quantitative measurements by placing calipers at anatomical landmarks. However, these measurements remain subject to interoperator variability as they rely largely on manual caliper placement. Conventional methods often use specialized prediction heads for different ultrasound tasks, whereas vision-language models offer flexibility through text instructions. However, direct coordinate prediction does not explicitly model spatial likelihood distributions, limiting the representation of localization ambiguity. **Methods:** We propose Kev-Bio, a vision-language model that uses clinical measurement questions to guide ultrasound landmark detection. Inspired by System One decision models, Kev-Bio uses decision representations of the language model to generate queries for each caliper endpoint. These queries are matched against shared dense ultrasound features to produce spatial probability maps, from which landmark coordinates and clinical measurements are derived. The model is trained end-to-end using both landmark localization and clinical measurement losses. **Results:** On the nine-view FU/GU Biometry 2026 dataset, Kev-Bio achieves a mean radial error (MRE) of 22.50 pixels and a clinical measurement mean absolute error (MAE) of 15.38, outperforming the compared baselines in overall performance. **Conclusion:** These results demonstrate the effectiveness of Kev-Bio for ultrasound landmark detection and clinical measurement across different anatomical views. Our code and models are available at https://github.com/moeinheidari7829/Kev-Bio.

0.51

CAST: Calibrating Correspondences for Training-Free Biomedical In-Context Segmentation

cs.CV ·2026-11-17 ·Mingze Jiang, Jiashu Han, Haonan Chen, Zhiyi Li, Yilun Du +1 more
similarity 0.62
Abstract · 10 pages, 6 figures

Biomedical image segmentation must keep up with new anatomical structures, subjects, imaging modalities, and acquisition protocols, yet dense expert annotations are scarce and models trained on one cohort often struggle to transfer. In-context segmentation (ICS) offers a way out: a new structure is specified by a few annotated exemplars at inference time. However, reliable correspondence remains challenging in biomedical images, where adjacent structures often share similar appearances, and variations across subjects and imaging conditions further obscure their distinctions. We introduce CAST, a training-free framework built on a frozen DINOv3 backbone to calibrate fine-grained correspondences. Its stability test improves feature reliability at both global and patch-specific levels, while its coherence test assesses whether candidate correspondences are supported by consistent local structural context. Together, these tests enable more reliable correspondence across diverse anatomical structures and imaging conditions. Across eight biomedical benchmarks spanning 2D and 3D segmentation, cross-subject, and cross-modality transfer, CAST outperforms the strongest overall baseline by 12.34 percentage points in Dice and ranks first across all six volumetric settings. The versatility of CAST further opens up opportunities for challenging biomedical applications, including 2D-to-3D segmentation and atlas label transfer.

0.23