**Purpose:** Ultrasound biometry is widely used across various clinical applications, including prenatal and cardiac examinations, to obtain quantitative measurements by placing calipers at anatomical landmarks. However, these measurements remain subject to interoperator variability as they rely largely on manual caliper placement. Conventional methods often use specialized prediction heads for different ultrasound tasks, whereas vision-language models offer flexibility through text instructions. However, direct coordinate prediction does not explicitly model spatial likelihood distributions, limiting the representation of localization ambiguity. **Methods:** We propose Kev-Bio, a vision-language model that uses clinical measurement questions to guide ultrasound landmark detection. Inspired by System One decision models, Kev-Bio uses decision representations of the language model to generate queries for each caliper endpoint. These queries are matched against shared dense ultrasound features to produce spatial probability maps, from which landmark coordinates and clinical measurements are derived. The model is trained end-to-end using both landmark localization and clinical measurement losses. **Results:** On the nine-view FU/GU Biometry 2026 dataset, Kev-Bio achieves a mean radial error (MRE) of 22.50 pixels and a clinical measurement mean absolute error (MAE) of 15.38, outperforming the compared baselines in overall performance. **Conclusion:** These results demonstrate the effectiveness of Kev-Bio for ultrasound landmark detection and clinical measurement across different anatomical views. Our code and models are available at https://github.com/moeinheidari7829/Kev-Bio.

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Discrete Tokens: Preserving Numerical Continuity in Medical Vision-Language Models

cs.CV cs.AI ·2026-10-23 ·Dianye Huang, Jiamei Guo, Yue Zhou, Mingde Li, Yi Xiong +3 more
similarity 0.64
Abstract

Objective: To develop a unified vision-language model for prompt-conditioned quantitative ultrasound measurement that addresses the mismatch between continuous measurement targets and discrete token-based numerical prediction. Methods: This article presents HAD-VLM, a hybrid autoregressive-diffusion framework that combines autoregressive text generation with continuous measurement prediction within a shared backbone. Visual prompt tuning adapts the vision encoder to ultrasound images. A diffusion process predicts a five-component representation comprising caliper endpoint coordinates and measurement length. A post-processing strategy combining the proposed coordinate-length consistency mechanism with ensemble prediction is introduced to refine measurement estimates. We evaluate four echocardiographic measurement tasks on EchoNet-LVH, with additional assessments of medical question answering and X-ray vertebral measurement. Results: HAD-VLM achieves mean absolute errors of 1.36, 2.77, 3.05, and 1.16 mm for IVSd, LVIDd, LVIDs, and LVPWd, respectively, reducing errors by 21.4-37.6\% relative to the Vicuna-based autoregressive baseline. It also outperforms fine-tuned Qwen3-VL and direct MLP regression across all four tasks. Medical question answering performance is preserved on the evaluated dataset. For X-ray vertebral measurement, HAD-VLM reduces mean absolute error from 11.4 to 6.7 pixels. Conclusion: Integrating autoregressive language generation with diffusion-based continuous prediction improves quantitative medical image measurement while retaining prompt-conditioned task flexibility. Significance: HAD-VLM provides a unified approach to combining language interaction with anatomically grounded numerical prediction for quantitative medical image analysis.

0.32

Localization Lens for Improving Medical Vision-Language Models

cs.CV cs.AI ·2026-10-03 ·Hasan Farooq, Murtaza Taj, Mehwish Nasim, Arif Mahmood
top venuecode/datahighly cited similarity 0.63
Abstract · 10 pages, 1 figure, Medical Image Computing and Computer Assisted Intervention (MICCAI)

Medical Vision-Language Models (Med-VLMs) have demonstrated strong capabilities in clinical tasks. However, they often struggle to understand anatomical structures and spatial positioning, which are crucial for medical reasoning. To address this, we propose a localization-aware enhancement to the Med-VLM pipeline, introducing improvements at three levels: data,architecture, and alignment. First, we introduce localization lens, a set of expert-validated representations that provide richer anatomical and positional context. However, as these representations increase input complexity, we integrate pixel shuffle within the model architecture to filter and refine representations, enhancing spatial information processing while preserving anatomical continuity. Lastly, to effectively align the localization lens representations with textual features, we incorporate decoupled contrastive loss (DCL) alongside the standard loss function. This ensures better feature discrimination and robustness, particularly in data limited medical settings. Through extensive evaluations on medical visual question answering (Med-VQA) datasets, we show that our methodology improves localization-driven performance across different Med-VLM architectures. Our analysis of localization-based questions further reveals that improvements in anatomy and spatial reasoning directly enhance the overall accuracy of Med-VQA upto 6.2%. The proposed approach is model-agnostic and can be seamlessly integrated into existing Med-VLM pipelines. The dataset, code, and trained models will be made publicly available at https://github.com/CVLABLUMS/localizationlens.

0.73

Anatomy-Guided Foundation Model Adaptation with Within-Case Prototype Supervision for Standard Plane Detection in Fetal Ultrasound Blind Sweeps

cs.CV eess.IV ·2026-08-27 ·Yuzhe Zhao
benchmark similarity 0.62
Abstract

Detecting the fetal abdominal circumference standard plane in low-cost obstetric blind sweeps is a highly imbalanced frame-classification problem: positive frames account for under 3% of a sequence, form short contiguous segments, and are poorly handled by off-the-shelf ultrasound and vision foundation models. We propose AnatoProto, a lightweight sequence-level framework that adapts a frozen BiomedCLIP encoder to fetal blind sweeps through four components: (i) anatomy-weighted spatial pooling that uses nnU-Net abdominal-region probabilities as a spatial prior to reweight BiomedCLIP patch tokens, so frozen semantic features are aggregated onto anatomically meaningful regions; (ii) a within-case prototype loss that pulls each frame embedding toward the mean of positive frames of the same sweep, exploiting case-level structure unavailable at the frame level; (iii) a three-stage cascade refinement (frame->segment->case-level rejecter) that lifts the prediction unit from noisy frames to structurally-constrained segments; and (iv) a hybrid prediction head that jointly models per-frame stability and inter-frame boundary transitions to suppress boundary false positives. On the ACOUSLIC-AI benchmark, AnatoProto reaches a test F1 of 67.72, outperforming the strongest foundation-model baseline (FetalCLIP + PRS, F1 = 54.52) by +13.20 F1 and the strongest video temporal-action-detection baseline (TriDet + PRS) by +15.76 F1. A synergy study, backed by embedding geometry and paired-bootstrap confidence intervals, shows that the prototype loss and anatomy-weighted pooling are not additive: applied alone the prototype loss reduces recall by 12 points, but combined with anatomy-weighted pooling it increases recall by 6.5 points -- a sign-flip we trace to the accuracy of the within-case prototype.

0.31

FETALFusion: Resolution-Aware State-Space Modeling for Multi-Domain Fetal Head Segmentation

cs.CV cs.AI ·2026-10-13 ·Ammar Bhilwarawala, Mainak Bandyopadhyay
published similarity 0.61
Abstract · Accepted at the 15th International Conference on Image Processing Theory, Tools and Applications, 2026

Head circumference (HC) measured from 2D ultrasound is a routine marker of fetal growth, and automating it needs segmentations whose boundaries hold up on individual scans, not only on average. We present FETALFusion, a dual-path CNN-Mamba encoder-decoder for fetal head segmentation across acquisition types. It applies four-directional state-space scans only at the two highest-resolution stages, routes bottleneck features through domain-specific channel gates that are averaged at test time, and adds a weak landmark shape prior. We train jointly on transabdominal (HC-18) and transperineal (PSFHS) images and compare ten methods on a held-out test set of 471 images, each trained under one schedule and scored by surface distances at native resolution. FETALFusion reaches a Dice score of 0.963 and an HD95 of 2.10 mm without test-time augmentation or a domain label. It improves on U-Mamba on all five reported metrics (HD95 reduced by 0.31 mm; Holm-corrected ($p < 10^{-4}$), a lead that holds under test-time augmentation and across two independent training runs, and in the mean on U-Net, Attention U-Net and TransUNet. Residual encoders close the gap: a ResNet-34 UNet++ exceeds FETALFusion, and an ImageNet initialised ResNet-34 U-Net is best overall (HD95 1.75 mm). The ablation agrees. Calibrated against run-to-run variation, it attributes FETALFusion's measurable gains to the landmark shape prior and, on transperineal images, to the domain gates, while removing the state-space branch does not measurably change accuracy. HC from the predicted masks agrees with the clinical reference at an intraclass correlation of 0.9986.

0.34

Rethinking Medical Landmark Localization with Prototype Learning-based Progressive Offset Correction

cs.CV cs.AIcs.LG ·2026-08-10 ·Jingxian Xu, Yuhao Huang, Rusi Chen, Yanfeng Zhou, Dong Ni
published similarity 0.61
Abstract · 10 pages, 4 figures, 3 tables. Accepted by MICCAI MLMI 2026

Accurate landmark localization in medical images is a fundamental step for quantitative clinical measurement and downstream analysis. Existing localization methods have advanced, among which multi-stage refinement is a superior solution. Although this strategy mitigates the anatomical ambiguity inherent in single-stage global predictions, its high computational cost limits practical applicability. In this work, we propose a parameter-economic model, PPOC-LL, which leverages Prototype learning-based Progressive Offset Correction for Landmark Localization. Our contribution is three-fold. First, to drive coarse-to-fine landmark optimization, we introduce a multi-scale dynamic perception strategy for patch-level feature pyramid modeling. Second, to effectively handle anatomically similar patterns, we design a similarity-driven prototype learning mechanism that captures informative local semantics for robust offset prediction. Last, to stabilize the model learning and improve the overall performance, we incorporate a novel error-aware reliability regularization via tolerance-based balancing. We collected a large validation cohort, including two public and one private datasets spanning X-ray and ultrasound modalities, covering cephalometric, symphysis-fetal head, and fetal heart landmarks. Extensive experiments demonstrate that PPOC-LL achieves satisfactory performance with a favorable trade-off between accuracy and model complexity.

0.33

Anatomy-Activated Mixture-of-Experts for 3D Medical Vision-Language Pre-training

cs.CV cs.AI ·2026-11-07 ·Szymon Płotka, Gizem Mert, Pedro R. A. S. Bassi, Wenxuan Li, Zongwei Zhou +7 more
publishedcode/data similarity 0.60
Abstract · NeurIPS 2026

Medical Vision-Language Pre-training (VLP) leverages the semantic richness of radiology reports to learn 3D representations, yet current architectures remain fundamentally anatomy-agnostic. While clinical diagnostics rely on organ-specific context, standard encoders apply a uniform, dense parameterization to all volumetric patches, and existing Mixture-of-Experts (MoE) routers gate on isolated local features without explicit access to the organ composition of the scan or crop. We propose Anatomy-Activated Mixture-of-Experts (A$^{2}$MoE), a framework that incorporates anatomical inductive biases within the model's computational path. A$^{2}$MoE introduces two key components: (1) a Histogram Representation Router (HRR) that conditions expert selection on global visual context and a predicted anatomical composition histogram, encouraging anatomy-dependent expert weighting; and (2) an Organ-Query Multi-Scale Projector (OQMSP) that utilizes learnable queries to extract organ-level embeddings for fine-grained alignment without requiring manual annotations at inference. By routing at the patch level rather than the token level, A$^{2}$MoE reduces routing complexity by orders of magnitude while satisfying load balancing by construction. Pre-trained on over 60,000 multi-phase CT scans, A$^{2}$MoE achieves state-of-the-art performance across segmentation, classification, and detection benchmarks. Furthermore, we demonstrate that our anatomically grounded inductive biases support robust generalization to MRI and ultrasound, establishing a scalable foundation for medical representation learning. The code is available at https://github.com/gmum/A2MoE.

0.41

Ultrasound-Based Prediction of Cirrhosis Decompensation Using Large-Scale Computer Vision Models

eess.IV cs.AIcs.CV ·2026-09-03 ·Guangyi Zhang, Peiyun Ni, Eugene Cheah, Rajat Chandra, Peng Guo +2 more
published similarity 0.60
Abstract · 6 pages, 2 figures. Accepted and presented at IEEE EMBC 2026

Decompensation represents a critical transition in the course of cirrhosis, yet clinicians have limited non-invasive tools to reliably predict its onset. In this study, we propose a novel imaging-based approach that leverages large-scale computer vision models to analyze routine abdominal ultrasound images and extract predictive features beyond those captured by traditional laboratory-based risk scores. Ultrasound is widely available, low cost, and suitable for longitudinal surveillance, making it an attractive modality for scalable risk stratification and long-term follow-up. Our framework integrates automated ultrasound data processing with modern deep learning architectures to identify patients at high risk of decompensation prior to the occurrence of clinical deterioration. This non-invasive strategy offers a practical complement to existing clinical scoring systems and may enable earlier, more proactive management of patients with compensated cirrhosis.

0.38

Weakly Supervised Spatial Grounding for Discriminative Attention-Based Ultrasound-Histopathology Alignment in Prostate Cancer Grading

cs.CV ·2026-09-14 ·Obed Korshie Dzikunu, Emma Willis, Mohammad Mahdi Abootorabi, Mohamed Harmanani, Zhuoxin Guo +5 more
similarity 0.60
Abstract

Unpaired cross-modal distillation transfers grade structure from histopathology into a micro-ultrasound (micro-US) encoder by aligning a pooled needle-region embedding to a frozen histopathology teacher under grade-group correspondence alone. A single objective is thereby required to serve two distinct functions: rendering patch features discriminative of tissue state, and selecting which patches enter the pooled representation. We decouple them. Weak spatial supervision derived from percentage involvement, recorded routinely at biopsy, constrains the predicted proportion of malignant tissue within each core, acting on the encoder features independently of the alignment objective. The alignment loss then operates on features that differ across a core, and attention concentrates on a subset of patches rather than remaining near-uniform. On 7,166 biopsy cores from 811 patients across seven centers under patient-level 5-fold cross-validation, the method reaches 67.1 macro AUC and 68.5 csPCa AUC, against 61.2 and 52.8 for the existing unpaired alignment method and 63.1 and 62.6 for the strongest unimodal baselines. Ablation against existing attention regularizers designed to prevent attention-uniformity collapse shows that such regularizers do not substitute for label-derived supervision: they constrain the attention distribution, whereas the signal required acts on the features that attention reads.

0.17