CS Paper Radar

FETALFusion: Resolution-Aware State-Space Modeling for Multi-Domain Fetal Head Segmentation

Ammar Bhilwarawala, Mainak Bandyopadhyay

cs.CV cs.AI ·submitted 2026-10-13 08:35 UTC · v1
published

Abstract

Head circumference (HC) measured from 2D ultrasound is a routine marker of fetal growth, and automating it needs segmentations whose boundaries hold up on individual scans, not only on average. We present FETALFusion, a dual-path CNN-Mamba encoder-decoder for fetal head segmentation across acquisition types. It applies four-directional state-space scans only at the two highest-resolution stages, routes bottleneck features through domain-specific channel gates that are averaged at test time, and adds a weak landmark shape prior. We train jointly on transabdominal (HC-18) and transperineal (PSFHS) images and compare ten methods on a held-out test set of 471 images, each trained under one schedule and scored by surface distances at native resolution. FETALFusion reaches a Dice score of 0.963 and an HD95 of 2.10 mm without test-time augmentation or a domain label. It improves on U-Mamba on all five reported metrics (HD95 reduced by 0.31 mm; Holm-corrected ($p < 10^{-4}$), a lead that holds under test-time augmentation and across two independent training runs, and in the mean on U-Net, Attention U-Net and TransUNet. Residual encoders close the gap: a ResNet-34 UNet++ exceeds FETALFusion, and an ImageNet initialised ResNet-34 U-Net is best overall (HD95 1.75 mm). The ablation agrees. Calibrated against run-to-run variation, it attributes FETALFusion's measurable gains to the landmark shape prior and, on transperineal images, to the domain gates, while removing the state-space branch does not measurably change accuracy. HC from the predicted masks agrees with the clinical reference at an intraclass correlation of 0.9986.

Comment
Accepted at the 15th International Conference on Image Processing Theory, Tools and Applications, 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Cross-Device Transfer of a Hospital-Trained Fetal Head Circumference Model to a Low-Cost Handheld Ultrasound Probe

eess.IV ·2026-10-28 ·Patrick Gao, Lara Hart, Ken Sullivan
benchmark similarity 0.72
Abstract · 24 pages, 5 figures, 4 tables

Automated fetal head circumference (HC) measurement reaches near-expert accuracy on the HC18 benchmark, but published models are trained and evaluated on hospital-grade equipment. We quantify what happens when such a model is carried to a low-cost handheld probe. A lightweight segmentation network (CSM, 0.13M parameters) was trained on HC18 across five independent runs and applied without modification to images from a $1,350 handheld probe (SonoQue C3), acquired at the same visit as the reference hospital scan in 18 patients. In-domain accuracy was 2.34 +/- 0.43 mm; on handheld images the same model gave 16.12 mm against the hospital record, a 6.9-fold degradation. Input preprocessing, a choice rarely reported, accounted for about a third of that gap: direct resizing gave 49.45 mm against 16.12 mm for an aspect-preserving pipeline. A leave-one-out data-efficiency curve showed that fine-tuning on two images significantly worsened accuracy, and that from four images upward error fell by 0.75 mm per doubling of the local dataset (p = 0.0045), although no training-set size up to 27 images significantly improved on the unmodified model. Much of the residual gap belongs to the reference rather than the model: scored against a manual tracing of the same image the model was already within 10.48 mm, and its disagreement with sonographer calipers on the same frame was a near-constant offset, negative in 10 of 10 cases. A single calibration constant estimated leave-one-out reduced that disagreement from 8.12 mm to 3.49 mm, reaching the intraobserver reproducibility reported for experienced sonographers, but did not improve agreement with the hospital record. Cross-device evaluations should therefore report the input preprocessing used and characterise the precision of their reference standard.

0.21

Anatomy-Guided Foundation Model Adaptation with Within-Case Prototype Supervision for Standard Plane Detection in Fetal Ultrasound Blind Sweeps

cs.CV eess.IV ·2026-08-27 ·Yuzhe Zhao
benchmark similarity 0.68
Abstract

Detecting the fetal abdominal circumference standard plane in low-cost obstetric blind sweeps is a highly imbalanced frame-classification problem: positive frames account for under 3% of a sequence, form short contiguous segments, and are poorly handled by off-the-shelf ultrasound and vision foundation models. We propose AnatoProto, a lightweight sequence-level framework that adapts a frozen BiomedCLIP encoder to fetal blind sweeps through four components: (i) anatomy-weighted spatial pooling that uses nnU-Net abdominal-region probabilities as a spatial prior to reweight BiomedCLIP patch tokens, so frozen semantic features are aggregated onto anatomically meaningful regions; (ii) a within-case prototype loss that pulls each frame embedding toward the mean of positive frames of the same sweep, exploiting case-level structure unavailable at the frame level; (iii) a three-stage cascade refinement (frame->segment->case-level rejecter) that lifts the prediction unit from noisy frames to structurally-constrained segments; and (iv) a hybrid prediction head that jointly models per-frame stability and inter-frame boundary transitions to suppress boundary false positives. On the ACOUSLIC-AI benchmark, AnatoProto reaches a test F1 of 67.72, outperforming the strongest foundation-model baseline (FetalCLIP + PRS, F1 = 54.52) by +13.20 F1 and the strongest video temporal-action-detection baseline (TriDet + PRS) by +15.76 F1. A synergy study, backed by embedding geometry and paired-bootstrap confidence intervals, shows that the prototype loss and anatomy-weighted pooling are not additive: applied alone the prototype loss reduces recall by 12 points, but combined with anatomy-weighted pooling it increases recall by 6.5 points -- a sign-flip we trace to the accuracy of the within-case prototype.

0.31

Beyond In-Distribution Metrics: A Systematic Out-of-Distribution Evaluation of Congenital Heart Disease Segmentation

cs.CV cs.AI ·2026-09-15 ·Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh, Clare Pomeroy-Ward, Harikrishnan Anil Maya +3 more
published similarity 0.67
Abstract · 12 pages, 6 figures, 2 tables. Accepted at STACOM 2026, held in conjunction with MICCAI 2026

Congenital heart disease (CHD) diagnosis and surgical planning often require patient-specific 3D anatomical models, but manual segmentation is labor-intensive, particularly in complex anatomies. Although deep-learning methods can automate this process, they are typically evaluated in-distribution, despite clinically relevant shifts in scanner, protocol, institution, population, and imaging modality. We present, to our knowledge, the first systematic evaluation of out-of-distribution (OOD) generalization in CHD segmentation, using ImageCHD as a held-out target cohort. We compare representative segmentation architectures under combined CT and CMR training, CT-only training, self-supervised pretraining, and limited target-domain adaptation. In-distribution performance proves to be a poor indicator of cross-cohort robustness: nnU-Net achieves the highest validation Dice (0.77) but falls to 0.51 on ImageCHD, while SwinUNETR generalizes substantially better, reaching 0.67 Dice. MAE and JEPA pretraining provide only modest additional benefit, suggesting that architecture contributes more to robustness than the tested pretraining strategies in this setting. When limited target-domain supervision is introduced, all SwinUNETR variants exceed 0.76 Dice with only 11 labeled ImageCHD cases. These findings demonstrate that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation.

0.28

CAST: Calibrating Correspondences for Training-Free Biomedical In-Context Segmentation

cs.CV ·2026-11-17 ·Mingze Jiang, Jiashu Han, Haonan Chen, Zhiyi Li, Yilun Du +1 more
similarity 0.65
Abstract · 10 pages, 6 figures

Biomedical image segmentation must keep up with new anatomical structures, subjects, imaging modalities, and acquisition protocols, yet dense expert annotations are scarce and models trained on one cohort often struggle to transfer. In-context segmentation (ICS) offers a way out: a new structure is specified by a few annotated exemplars at inference time. However, reliable correspondence remains challenging in biomedical images, where adjacent structures often share similar appearances, and variations across subjects and imaging conditions further obscure their distinctions. We introduce CAST, a training-free framework built on a frozen DINOv3 backbone to calibrate fine-grained correspondences. Its stability test improves feature reliability at both global and patch-specific levels, while its coherence test assesses whether candidate correspondences are supported by consistent local structural context. Together, these tests enable more reliable correspondence across diverse anatomical structures and imaging conditions. Across eight biomedical benchmarks spanning 2D and 3D segmentation, cross-subject, and cross-modality transfer, CAST outperforms the strongest overall baseline by 12.34 percentage points in Dice and ranks first across all six volumetric settings. The versatility of CAST further opens up opportunities for challenging biomedical applications, including 2D-to-3D segmentation and atlas label transfer.

0.26

Cross-Modal Ultrasound-MRI Learning for Fetal Brain Ventricular Volumetry and Abnormality Screening

eess.IV cs.AIcs.CVcs.LG ·2026-08-14 ·Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant +1 more
similarity 0.64
Abstract · 17 pages, 11 figures, 6 tables

Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement. Fetal brain MRI provides more reliable volumetric information but is costly and less accessible for routine use. To address these limitations, we propose VIFBA, an ultrasound video-based framework for fetal brain assessment that predicts MRI-derived lateral ventricular volume, classifies VM severity, and identifies potential non-VM fetal brain abnormalities. Our contribution is three-fold. First, we introduce a joint-embedding predictive architecture (JEPA)-inspired tube latent prediction objective that leverages spatio-temporal coherence in ultrasound videos to enhance representation learning. Second, we develop a contrastive cross-modal alignment strategy that transfers structural information from MRI to ultrasound during training, while requiring ultrasound alone at inference. Third, we augment VIFBA with a training-free vision-language model and retrieval augmentation to verify uncertain predictions and identify potential non-VM fetal brain abnormalities. We validated VIFBA on a large dataset comprising 857 cases (3,196 videos) with paired fetal brain ultrasound and MRI examinations. On held-out test data, VIFBA achieved an MAE of 0.5909 mL and Pearson correlation coefficient of 0.9907 for ventricular volume regression, 0.9400 accuracy for VM severity classification, and an F1 score of 0.7764 for multi-abnormality classification, substantially outperforming single-task baselines, video-based strong competitors, and state-of-the-art foundation models. By enabling MRI-informed volumetric assessment from routine ultrasound alone, VIFBA offers a practical and potentially broadly deployable pathway toward accurate and affordable prenatal brain screening.

0.10

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.64
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

Automated Fetal Brain MRI Biometry in Healthy and Pathological Cases

cs.CV ·2026-08-16 ·Ema Masterl, Tina Vipotnik Vesnaver, Nejc Šubič, Žiga Špiclin
published similarity 0.63
Abstract · Accepted at the PIPPI Workshop of MICCAI 2026

Automated biometric analysis of fetal brain MRI enables reproducible, observer-independent quantitative assessment, yet existing methods are often restricted to few measurements or evaluated only on healthy cases. We assemble and evaluate an automated biometric analysis pipeline that localizes 22 anatomical landmarks on NeSVoR-reconstructed 3D volumes and derives 11 clinically relevant measurements spanning supratentorial, ventricular, cerebellar, and midline structures. We compare two landmark localization models, H3DE-Net and SCN, on a heterogeneous cohort of 122 acquisitions (both healthy controls and range pathologies). Localization accuracy was assessed with a linear mixed-effects model, agreement with normative growth trajectories with calibrated centile charts, and diagnostic utility with a decision tree classifying VM severity. H3DE-Net achieved significantly lower localization error than SCN across all landmarks (mean 1.36 mm vs. 3.58 mm in HC and 1.90 mm vs. 4.13 mm in PC; p < 0.001), and outperformed a GA-based regression baseline in 7 of 11 measurements. H3DE-Net measurements yielded higher classification AUC in every diagnostic group, with the clearest advantage in separating healthy controls from VM. Decision tree thresholds for ventricular width fell near the clinical 10 mm and 15 mm cut-offs used to define and grade VM.

0.18

A Dual-Stream Regulated Reconstruction and Segmentation Network with Hierarchical Artifact-Prior Modeling for Ultra-Low-Field Pediatric Neuroimaging

cs.CV ·2026-09-17 ·Bahram Jafrasteh, Leo Milecki, Qingyu Zhao
similarity 0.63
Abstract

Automated quality assessment, enhancement, and segmentation of multiple structures in $0.064\,\mathrm{T}$ ultra-low-field pediatric MRI are limited by a low signal-to-noise ratio, weak anatomical boundaries, and frequent artifacts. We present a unified framework for the LISA 2026 Challenge that performs all three tasks together within one inference pipeline. A network with two coupled streams, built on a 3D U-Net, first reconstructs an enhanced uLF volume and then combines the original and enhanced images for subcortical segmentation. To improve boundary stability, we add an auxiliary class covering brain tissue outside the target structures, derived from whole brain masks. A head conditioned on an artifact graph predicts the seven artifact ratings from reconstruction residuals and frozen segmentation features. We address the scarcity of dense annotations using diffeomorphic registration from atlas to target for label propagation and to regularize anatomical reconstruction. We report validation results across all three tasks.

0.12