CS Paper Radar

Cross-Modal Ultrasound-MRI Learning for Fetal Brain Ventricular Volumetry and Abnormality Screening

Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant, Davood Karimi

eess.IV cs.AIcs.CVcs.LG ·submitted 2026-08-14 10:33 UTC · v1

Abstract

Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement. Fetal brain MRI provides more reliable volumetric information but is costly and less accessible for routine use. To address these limitations, we propose VIFBA, an ultrasound video-based framework for fetal brain assessment that predicts MRI-derived lateral ventricular volume, classifies VM severity, and identifies potential non-VM fetal brain abnormalities. Our contribution is three-fold. First, we introduce a joint-embedding predictive architecture (JEPA)-inspired tube latent prediction objective that leverages spatio-temporal coherence in ultrasound videos to enhance representation learning. Second, we develop a contrastive cross-modal alignment strategy that transfers structural information from MRI to ultrasound during training, while requiring ultrasound alone at inference. Third, we augment VIFBA with a training-free vision-language model and retrieval augmentation to verify uncertain predictions and identify potential non-VM fetal brain abnormalities. We validated VIFBA on a large dataset comprising 857 cases (3,196 videos) with paired fetal brain ultrasound and MRI examinations. On held-out test data, VIFBA achieved an MAE of 0.5909 mL and Pearson correlation coefficient of 0.9907 for ventricular volume regression, 0.9400 accuracy for VM severity classification, and an F1 score of 0.7764 for multi-abnormality classification, substantially outperforming single-task baselines, video-based strong competitors, and state-of-the-art foundation models. By enabling MRI-informed volumetric assessment from routine ultrasound alone, VIFBA offers a practical and potentially broadly deployable pathway toward accurate and affordable prenatal brain screening.

Comment
17 pages, 11 figures, 6 tables

Closest papers

Nearest neighbours by meaning across the whole index.

WASP: Weakly Aligned Spatiotemporal Pairs for Fetal Brain MRI-Ultrasound Learning

cs.CV cs.LG ·2026-10-03 ·Francesco Correnti, Gabriele Magrini, Marco Mistretta, Niccolò Biondi, Pietro Pala +4 more
top venuecode/data similarity 0.69
Abstract · Accepted at NeurIPS 2026. 21 pages, 3 figures, 11 tables. Code: https://github.com/miccunifi/WASP

Magnetic Resonance Imaging (MRI) is widely regarded as the optimal sensor for fetal brain analysis due to its superior soft-tissue contrast and anatomical detail. However, its high cost and operational burden make it invasive and difficult to obtain at scale. Ultrasound (US), in contrast, is cheap, safe, and routinely acquired, and as a result it has produced substantially larger datasets and a growing ecosystem of pretrained models. This asymmetry raises a natural question: Can we teach a US-only model to understand fetal MRI from only a limited set of examples? The standard recipe, training a foundation model on subject-to-subject paired MRI-US scans, is not viable since no such paired fetal dataset is publicly available. In this paper we address this gap with Weakly Aligned Spatiotemporal Pairs (WASP), a framework that formulates cross-modal correspondence as an entropic Optimal Transport problem driven by clinical metadata, in particular Gestational Age (GA) and diagnostic planes, enabling the fitting of a lightweight alignment module that lifts MRI representations into the US latent space, without fine-tuning the backbone. Empirically, WASP yields its largest gains when MRI is unseen by the model during pretraining (on USFM, GA estimation error drops from 21.9 to 17.4 days and standard plane classification accuracy climbs from 61.9% to 69.0%), while providing smaller, backbone-dependent refinements for backbones pretrained on both modalities (e.g., BioMedParse GA estimation error from 6.5 to 6.0 days and SAM-Med2d plane accuracy from 83.3% to 88.1%). Code is available at https://github.com/miccunifi/WASP.

0.46

AWR-Net: Decoupling Anatomy and Appearance for 3D Fetal Brain Ultrasound Synthesis

eess.IV cs.CV ·2026-09-18 ·Yuhuan Lu, Sergio Valencia, Yuanji Zhang, Yuhao Huang, Camilo Jaimes +2 more
similarity 0.67
Abstract · 10 pages, 6 figures

Three-dimensional fetal brain ultrasound offers non-ionizing, cost-effective imaging with rich spatial information for comprehensive anatomical assessment, yet its development remains limited by scarce data and annotations. In contrast, fetal brain magnetic resonance imaging has advanced further, supported by larger datasets and mature analysis methods. To leverage these resources, anatomical label maps provide a promising modality-invariant bridge for transferring knowledge from fetal brain magnetic resonance imaging to ultrasound. However, generating ultrasound images from label maps remains challenging because anatomy is tightly entangled with ultrasound appearance. To address this challenge, we separate anatomical correspondence learning from ultrasound appearance adaptation at both the data and model levels. Specifically, we propose the anatomy wavelet residual network, a two-stage framework combining wavelet diffusion and residual refinement. The first stage learns to generate volumes from label maps using atlas pairs in the wavelet domain, while the second stage learns bounded residual corrections from real clinical ultrasound in the image domain. This separation enables realistic synthesis with consistent preservation of normal and abnormal anatomy. Experiments on real fetal brain ultrasound show that our method outperforms representative synthesis methods, with normalized cross correlation of 0.518 versus 0.482 and Fréchet Inception Distance of 8.905 versus 13.319 for the strongest baseline. Beyond synthesis quality, volumes generated from fetal brain magnetic resonance imaging label maps also improve downstream segmentation, particularly for severe abnormal cases. Overall, these results highlight the potential of the proposed framework to leverage rich fetal brain magnetic resonance imaging resources for advancing three-dimensional ultrasound analysis.

0.30

FETALFusion: Resolution-Aware State-Space Modeling for Multi-Domain Fetal Head Segmentation

cs.CV cs.AI ·2026-10-13 ·Ammar Bhilwarawala, Mainak Bandyopadhyay
published similarity 0.64
Abstract · Accepted at the 15th International Conference on Image Processing Theory, Tools and Applications, 2026

Head circumference (HC) measured from 2D ultrasound is a routine marker of fetal growth, and automating it needs segmentations whose boundaries hold up on individual scans, not only on average. We present FETALFusion, a dual-path CNN-Mamba encoder-decoder for fetal head segmentation across acquisition types. It applies four-directional state-space scans only at the two highest-resolution stages, routes bottleneck features through domain-specific channel gates that are averaged at test time, and adds a weak landmark shape prior. We train jointly on transabdominal (HC-18) and transperineal (PSFHS) images and compare ten methods on a held-out test set of 471 images, each trained under one schedule and scored by surface distances at native resolution. FETALFusion reaches a Dice score of 0.963 and an HD95 of 2.10 mm without test-time augmentation or a domain label. It improves on U-Mamba on all five reported metrics (HD95 reduced by 0.31 mm; Holm-corrected ($p < 10^{-4}$), a lead that holds under test-time augmentation and across two independent training runs, and in the mean on U-Net, Attention U-Net and TransUNet. Residual encoders close the gap: a ResNet-34 UNet++ exceeds FETALFusion, and an ImageNet initialised ResNet-34 U-Net is best overall (HD95 1.75 mm). The ablation agrees. Calibrated against run-to-run variation, it attributes FETALFusion's measurable gains to the landmark shape prior and, on transperineal images, to the domain gates, while removing the state-space branch does not measurably change accuracy. HC from the predicted masks agrees with the clinical reference at an intraclass correlation of 0.9986.

0.34

Towards Whole-Study Screening for Congenital Heart Disease in Fetal Ultrasound Using Multiple Instance Learning

eess.IV cs.CV ·2026-09-25 ·Mohamed Azzam, Ruobing Liu, Esther C. Ugwueke, Ziyang Xu, Shibiao Wan +6 more
similarity 0.62
Abstract

Congenital heart disease (CHD) is the most common birth defect, yet a large fraction of cases remain undetected on prenatal ultrasound, in part because current artificial-intelligence methods assume that the key diagnostic frames have already been isolated from a study, by a clinician or by a view classifier. We remove that assumption and address CHD screening directly at the level of the whole ultrasound study. We propose a two-stage framework that first learns transferable frame representations by self-supervised masked-autoencoder pre-training on unlabeled fetal ultrasound, then identifies cardiac frames with a disease-robust module and aggregates them with a transformer-based multiple instance learning (MIL) model that produces a case-level diagnosis from study-level labels alone. The model further returns its highest-scoring frames for clinician review, and a hierarchical head separates critical from non-critical CHD. On the internal test set of our multi-source development cohort (FUSE), the proposed cardiac-gated MIL model reaches an area under the curve (AUC) of 0.985 with a specificity of 0.990, outperforming the reproduced NATMED ensemble (AUC 0.861, specificity 0.600) and the FetalCLIP foundation model (AUC 0.867, specificity 0.710). On an independent external cohort, all models initially perform near chance, but label-free CORAL adaptation raises the proposed model from an AUC of 0.513 to 0.944, whereas whole-study and view-dependent baselines do not recover. These results indicate that whole-study MIL with disease-robust cardiac-frame identification is an accurate and deployable route to prenatal CHD screening.

0.15

Mr3D-VL: A generalist vision language foundation model for Multiparametric 3D Magnetic Resonance Imaging

cs.CV cs.AI ·2026-08-13 ·Zhi Qiao, Xintong Wu, Yichu He, Feng Shi
similarity 0.62
Abstract

Multi-parametric magnetic resonance imaging (mpMRI) is a cornerstone for brain tumor diagnosis and treatment, yet current AI models face critical limitations: their lack of natural language interaction and interpretability impedes spatial information integration and cross-modal reasoning required clinically. Key challenges arise from significant physical meaning differences across modalities, spatial misalignment due to scan intervals, and the need for complex multi-feature interpretation in tasks like glioma grading. While visual-language models (VLMs) show promise in cross-modal understanding, existing methods focus mainly on 2D image modeling, neglecting direct perception of 3D volumetric space. Although 3D VLMs have been proposed for report generation and feature alignment in 3D CT imaging, mpMRI applications demand collaborative inference across multiple imaging modalities-a requirement unmet by current solutions. To address this, we introduce Mr3D-VL, a dedicated visual-language foundation model for multi-parametric 3D MRI. With 4 billion parameters, it employs an unsupervised pre-trained shared 3D encoder and 4D rotational positional embedding for dual modality-spatial integration. Its cross-modal projection layer uses a multi-resolution feature implantation strategy to enhance feature perception across resolutions. Experimental results show significant improvements over existing 4B/7B/30B domain-specific and general-purpose models in text generation tasks, achieving a BERTScore of 0.856 for report generation, with question-answering accuracy at 0.713 and multiple-choice accuracy at 0.912.

0.04

MR-JEPA: A General Purpose Video Foundation Model for Cardiac MRI

cs.CV cs.AI ·2026-08-31 ·Athira J. Jacob, Puneet Sharma, Dorin Comaniciu, Daniel Rueckert
published similarity 0.62
Abstract · Accepted at STACOM 2026 (MICCAI 2026 peer-reviewed workshop)

Cardiac magnetic resonance imaging (CMR) produces rich sequential data such as temporal cine videos and spatial LGE/mapping stacks, yet most deep learning approaches process individual 2D slices, discarding this context. We present MR-JEPA, a self-supervised video foundation model for CMR that extends LeJEPA to 3D spatiotemporal inputs through tubelet tokenization, spatiotemporal masking augmentation, and initialization from a 2D CMR foundation model. Unlike prior CMR video models limited to cine data, MR-JEPA is pretrained on multi-sequence data (cine, LGE, mapping) from 10,505 patients across two centers without annotations. We evaluate the frozen encoder on six downstream tasks using a unified multi-view gated attention architecture: LV ejection fraction, RV ejection fraction, three myocardial strains (GLS, GCS, GRS), and four-class disease detection. MR-JEPA outperforms other compared methods on all five regression tasks, including both a domain-specific CMR model pretrained on more data with text supervision and a natural-video foundation model, achieving an LV EF MAE of 4.79% (r =0.764) and a GLS MAE of 1.87 (r=0.805), with 21-27% MAE reductions over baselines on strain tasks. For disease detection, MR-JEPA achieved a macro AUG of 0.868, remaining competitive with the domain-specific baseline despite using a fully self-supervised pretraining objective. These results demonstrate the potential of a unified video encoder for robust, multi-view utilization of diverse CMR sequences in clinical cardiac quantification and diagnosis.

0.31

Anatomy-Guided Foundation Model Adaptation with Within-Case Prototype Supervision for Standard Plane Detection in Fetal Ultrasound Blind Sweeps

cs.CV eess.IV ·2026-08-27 ·Yuzhe Zhao
benchmark similarity 0.62
Abstract

Detecting the fetal abdominal circumference standard plane in low-cost obstetric blind sweeps is a highly imbalanced frame-classification problem: positive frames account for under 3% of a sequence, form short contiguous segments, and are poorly handled by off-the-shelf ultrasound and vision foundation models. We propose AnatoProto, a lightweight sequence-level framework that adapts a frozen BiomedCLIP encoder to fetal blind sweeps through four components: (i) anatomy-weighted spatial pooling that uses nnU-Net abdominal-region probabilities as a spatial prior to reweight BiomedCLIP patch tokens, so frozen semantic features are aggregated onto anatomically meaningful regions; (ii) a within-case prototype loss that pulls each frame embedding toward the mean of positive frames of the same sweep, exploiting case-level structure unavailable at the frame level; (iii) a three-stage cascade refinement (frame->segment->case-level rejecter) that lifts the prediction unit from noisy frames to structurally-constrained segments; and (iv) a hybrid prediction head that jointly models per-frame stability and inter-frame boundary transitions to suppress boundary false positives. On the ACOUSLIC-AI benchmark, AnatoProto reaches a test F1 of 67.72, outperforming the strongest foundation-model baseline (FetalCLIP + PRS, F1 = 54.52) by +13.20 F1 and the strongest video temporal-action-detection baseline (TriDet + PRS) by +15.76 F1. A synergy study, backed by embedding geometry and paired-bootstrap confidence intervals, shows that the prototype loss and anatomy-weighted pooling are not additive: applied alone the prototype loss reduces recall by 12 points, but combined with anatomy-weighted pooling it increases recall by 6.5 points -- a sign-flip we trace to the accuracy of the within-case prototype.

0.31

STORK: Spatio-Temporal Observation of uterine contRactions via neural networKs

cs.CV ·2026-10-07 ·Melissa Schween, Tristan Gottwald, Jordina Aviles Verdera, Lisa Story, Mary Rutherford +1 more
published similarity 0.61
Abstract · Accepted at the PIPPI Workshop at MICCAI 2026 and will appear in the workshop proceedings (Springer)

Uterine contractions in fetal MRI are typically identified manually and discarded, limiting insights into contraction dynamics. We formalize Uterine Contractile Activity Detection (UCAD) as a weakly-supervised learning problem and introduce STORK, a multi-instance learning model trained on dynamic MRI series using only coarse, series-level labels. STORK factorizes 3D spatio-temporal convolutions into parallel branches across temporal hyperplanes to capture coherent tissue motion without the cost of full 4D convolutions. Per-frame embeddings, combining intensity and Demons-estimated displacement fields, are aggregated by a linear mean-pooling head. This ensures that frame-level contraction scores can be recovered post-hoc without frame-level training supervision. Evaluated on around 700 multi-vendor dynamic fetal MRI series, STORK achieves a series-level AUROC of 95.0% and AUPRC of 94.6%, substantially outperforming 3D ResNet and ConvNeXt baselines. Grad-CAM analysis suggests that the model draws on predictive features extending beyond the placenta into the uterine tissue, offering an automated tool for richer phenotyping of uterine behavior.

0.25