Automated Fetal Brain MRI Biometry in Healthy and Pathological Cases

Ema Masterl, Tina Vipotnik Vesnaver, Nejc Šubič, Žiga Špiclin

cs.CV ·submitted 2026-08-16 11:48 UTC · v1
published

Abstract

Automated biometric analysis of fetal brain MRI enables reproducible, observer-independent quantitative assessment, yet existing methods are often restricted to few measurements or evaluated only on healthy cases. We assemble and evaluate an automated biometric analysis pipeline that localizes 22 anatomical landmarks on NeSVoR-reconstructed 3D volumes and derives 11 clinically relevant measurements spanning supratentorial, ventricular, cerebellar, and midline structures. We compare two landmark localization models, H3DE-Net and SCN, on a heterogeneous cohort of 122 acquisitions (both healthy controls and range pathologies). Localization accuracy was assessed with a linear mixed-effects model, agreement with normative growth trajectories with calibrated centile charts, and diagnostic utility with a decision tree classifying VM severity. H3DE-Net achieved significantly lower localization error than SCN across all landmarks (mean 1.36 mm vs. 3.58 mm in HC and 1.90 mm vs. 4.13 mm in PC; p < 0.001), and outperformed a GA-based regression baseline in 7 of 11 measurements. H3DE-Net measurements yielded higher classification AUC in every diagnostic group, with the clearest advantage in separating healthy controls from VM. Decision tree thresholds for ventricular width fell near the clinical 10 mm and 15 mm cut-offs used to define and grade VM.

Comment
Accepted at the PIPPI Workshop of MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Generalizable fetal brain biometry via adaptive artificial intelligence

cs.CV ·2026-10-11 ·Yijin Li, Mingxuan Liu, Yi Liao, Le Chang, Hongjia Yang +22 more
similarity 0.77
Abstract · 67 pages, 8 figures

Fetal brain biometry provides a quantitative basis for assessing prenatal growth and identifying congenital brain abnormalities. However, comprehensive assessment remains limited by labor-intensive manual measurements and automated models that lose accuracy across imaging sequences and institutions. We introduce BioTTA, an anatomically guided test-time adaptation framework that measures 11 fetal brain biometrics from reconstructed three-dimensional magnetic resonance images. BioTTA adapts pretrained models to individual unlabeled volumes using geometric consistency and atlas priors, without access to source images. In a retrospective study across five centers in China and Switzerland, BioTTA improved measurement accuracy across three out-of-distribution datasets and two network architectures. It reduced mean absolute measurement errors by 46-82% relative to the corresponding models without adaptation, achieving errors similar to those of supervised fine-tuning. Its measurements were mapped onto normative growth trajectories derived from expert annotations, enabling gestational-age-specific assessment through a web-based reporting platform. Across four disease cohorts, the platform achieved 82.1-95.0% accuracy in binary detection of ventriculomegaly or cerebellar abnormalities, with performance similar to that of a senior radiologist. BioTTA provides a practical foundation for standardized fetal brain biometry across heterogeneous imaging settings, supporting scalable prenatal growth assessment and quantitative evaluation of brain abnormalities.

0.13

FETALFusion: Resolution-Aware State-Space Modeling for Multi-Domain Fetal Head Segmentation

cs.CV cs.AI ·2026-10-13 ·Ammar Bhilwarawala, Mainak Bandyopadhyay
published similarity 0.63
Abstract · Accepted at the 15th International Conference on Image Processing Theory, Tools and Applications, 2026

Head circumference (HC) measured from 2D ultrasound is a routine marker of fetal growth, and automating it needs segmentations whose boundaries hold up on individual scans, not only on average. We present FETALFusion, a dual-path CNN-Mamba encoder-decoder for fetal head segmentation across acquisition types. It applies four-directional state-space scans only at the two highest-resolution stages, routes bottleneck features through domain-specific channel gates that are averaged at test time, and adds a weak landmark shape prior. We train jointly on transabdominal (HC-18) and transperineal (PSFHS) images and compare ten methods on a held-out test set of 471 images, each trained under one schedule and scored by surface distances at native resolution. FETALFusion reaches a Dice score of 0.963 and an HD95 of 2.10 mm without test-time augmentation or a domain label. It improves on U-Mamba on all five reported metrics (HD95 reduced by 0.31 mm; Holm-corrected ($p < 10^{-4}$), a lead that holds under test-time augmentation and across two independent training runs, and in the mean on U-Net, Attention U-Net and TransUNet. Residual encoders close the gap: a ResNet-34 UNet++ exceeds FETALFusion, and an ImageNet initialised ResNet-34 U-Net is best overall (HD95 1.75 mm). The ablation agrees. Calibrated against run-to-run variation, it attributes FETALFusion's measurable gains to the landmark shape prior and, on transperineal images, to the domain gates, while removing the state-space branch does not measurably change accuracy. HC from the predicted masks agrees with the clinical reference at an intraclass correlation of 0.9986.

0.34

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

eess.IV ·2026-11-12 ·Wenxuan Wu, Lucy Hall, Jonathan O'Muircheartaigh, Joseph V. Hajnal, J-Donald Tournier +1 more
similarity 0.62
Abstract

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

0.13

WASP: Weakly Aligned Spatiotemporal Pairs for Fetal Brain MRI-Ultrasound Learning

cs.CV cs.LG ·2026-10-03 ·Francesco Correnti, Gabriele Magrini, Marco Mistretta, Niccolò Biondi, Pietro Pala +4 more
top venuecode/data similarity 0.61
Abstract · Accepted at NeurIPS 2026. 21 pages, 3 figures, 11 tables. Code: https://github.com/miccunifi/WASP

Magnetic Resonance Imaging (MRI) is widely regarded as the optimal sensor for fetal brain analysis due to its superior soft-tissue contrast and anatomical detail. However, its high cost and operational burden make it invasive and difficult to obtain at scale. Ultrasound (US), in contrast, is cheap, safe, and routinely acquired, and as a result it has produced substantially larger datasets and a growing ecosystem of pretrained models. This asymmetry raises a natural question: Can we teach a US-only model to understand fetal MRI from only a limited set of examples? The standard recipe, training a foundation model on subject-to-subject paired MRI-US scans, is not viable since no such paired fetal dataset is publicly available. In this paper we address this gap with Weakly Aligned Spatiotemporal Pairs (WASP), a framework that formulates cross-modal correspondence as an entropic Optimal Transport problem driven by clinical metadata, in particular Gestational Age (GA) and diagnostic planes, enabling the fitting of a lightweight alignment module that lifts MRI representations into the US latent space, without fine-tuning the backbone. Empirically, WASP yields its largest gains when MRI is unseen by the model during pretraining (on USFM, GA estimation error drops from 21.9 to 17.4 days and standard plane classification accuracy climbs from 61.9% to 69.0%), while providing smaller, backbone-dependent refinements for backbones pretrained on both modalities (e.g., BioMedParse GA estimation error from 6.5 to 6.0 days and SAM-Med2d plane accuracy from 83.3% to 88.1%). Code is available at https://github.com/miccunifi/WASP.

0.46

Cross-Modal Ultrasound-MRI Learning for Fetal Brain Ventricular Volumetry and Abnormality Screening

eess.IV cs.AIcs.CVcs.LG ·2026-08-14 ·Yuhao Huang, Yuanji Zhang, Yuhuan Lu, Dong Ni, P. Ellen Grant +1 more
similarity 0.58
Abstract · 17 pages, 11 figures, 6 tables

Assessment of ventriculomegaly (VM) on fetal brain ultrasound relies primarily on measuring lateral ventricular atrial width on standard planes, which is operator-dependent and may not fully reflect the overall ventricular enlargement. Fetal brain MRI provides more reliable volumetric information but is costly and less accessible for routine use. To address these limitations, we propose VIFBA, an ultrasound video-based framework for fetal brain assessment that predicts MRI-derived lateral ventricular volume, classifies VM severity, and identifies potential non-VM fetal brain abnormalities. Our contribution is three-fold. First, we introduce a joint-embedding predictive architecture (JEPA)-inspired tube latent prediction objective that leverages spatio-temporal coherence in ultrasound videos to enhance representation learning. Second, we develop a contrastive cross-modal alignment strategy that transfers structural information from MRI to ultrasound during training, while requiring ultrasound alone at inference. Third, we augment VIFBA with a training-free vision-language model and retrieval augmentation to verify uncertain predictions and identify potential non-VM fetal brain abnormalities. We validated VIFBA on a large dataset comprising 857 cases (3,196 videos) with paired fetal brain ultrasound and MRI examinations. On held-out test data, VIFBA achieved an MAE of 0.5909 mL and Pearson correlation coefficient of 0.9907 for ventricular volume regression, 0.9400 accuracy for VM severity classification, and an F1 score of 0.7764 for multi-abnormality classification, substantially outperforming single-task baselines, video-based strong competitors, and state-of-the-art foundation models. By enabling MRI-informed volumetric assessment from routine ultrasound alone, VIFBA offers a practical and potentially broadly deployable pathway toward accurate and affordable prenatal brain screening.

0.10

Rethinking Medical Landmark Localization with Prototype Learning-based Progressive Offset Correction

cs.CV cs.AIcs.LG ·2026-08-10 ·Jingxian Xu, Yuhao Huang, Rusi Chen, Yanfeng Zhou, Dong Ni
published similarity 0.57
Abstract · 10 pages, 4 figures, 3 tables. Accepted by MICCAI MLMI 2026

Accurate landmark localization in medical images is a fundamental step for quantitative clinical measurement and downstream analysis. Existing localization methods have advanced, among which multi-stage refinement is a superior solution. Although this strategy mitigates the anatomical ambiguity inherent in single-stage global predictions, its high computational cost limits practical applicability. In this work, we propose a parameter-economic model, PPOC-LL, which leverages Prototype learning-based Progressive Offset Correction for Landmark Localization. Our contribution is three-fold. First, to drive coarse-to-fine landmark optimization, we introduce a multi-scale dynamic perception strategy for patch-level feature pyramid modeling. Second, to effectively handle anatomically similar patterns, we design a similarity-driven prototype learning mechanism that captures informative local semantics for robust offset prediction. Last, to stabilize the model learning and improve the overall performance, we incorporate a novel error-aware reliability regularization via tolerance-based balancing. We collected a large validation cohort, including two public and one private datasets spanning X-ray and ultrasound modalities, covering cephalometric, symphysis-fetal head, and fetal heart landmarks. Extensive experiments demonstrate that PPOC-LL achieves satisfactory performance with a favorable trade-off between accuracy and model complexity.

0.33

Automatic Cephalometric Landmark Localization on CBCT-Derived Digitally Reconstructed Radiographs for Skeletal Malocclusion Classification

cs.CV ·2026-08-17 ·Benjamin Hou, Konstantinia Almpani, Janice S. Lee, Zhiyong Lu
published similarity 0.54
Abstract · Accepted for presentation at the ODIN 2026 Workshop, held in conjunction with MICCAI 2026

Manual cephalometric landmark annotation is important for craniofacial assessment but is labor-intensive and difficult to scale. We introduce CephViT, a Vision Transformer-based model for automated 2D lateral cephalometric landmark localization, and evaluate its use in downstream skeletal malocclusion classification. CephViT was trained and benchmarked on a public lateral cephalogram dataset, achieving a mean radial error of 1.28 +/- 1.42 mm and a successful detection rate of 92.0% at 3.0 mm. Because the private evaluation cohort consisted of 3D CBCT scans, lateral cephalogram-like digitally reconstructed radiographs (DRRs) were generated from each volume and used as 2D inputs to the landmark localization model. Landmark coordinates were normalized into a common coordinate frame, and skeletal malocclusion classification was performed using landmarks shared between the reference and DRR-based pipelines. Classification performance using DRR-localized landmarks was comparable to that obtained using manually annotated reference landmarks, with accuracies of 70.0% and 68.3%, respectively. These results support the feasibility of automated cephalometric analysis on CBCT-derived DRRs for skeletal malocclusion assessment.

0.35

Automated Fetal Magnetocardiography Reconstruction Using a Biophysical Forward Model

eess.SP ·2026-10-23 ·Jonas Emrich, Karin Narushima, Lena Wunderl, Philipp Wunderl, Tobias Jensch +5 more
top venuecode/data similarity 0.54
Abstract · 29 pages, 16 figures. Includes supplementary material. Published in IEEE Transactions on Biomedical Engineering. Code: https://github.com/ML…

Objective: Fetal magnetocardiography (fMCG) enables early detection of cardiac disease by non-invasively measuring fetal electrophysiological activity. However, current signal estimation methods for fMCG require complex, labor-intensive human processing because they rely on blind source separation or template-based projection techniques. Methods: We propose an automated signal reconstruction approach that recovers fetal and maternal cardiac activity from fMCG measurements without manual annotation. Our approach leverages the relationship between measurements and cardiac signals via a biophysically grounded forward model that represents cardiac sources as time-varying magnetic dipoles. This enables reconstruction of physiologically interpretable three-dimensional vectorcardiographic signals along with their spatial position. Results: Validation on synthetic data with known ground truth confirms accurate recovery of cardiac source parameters. On real fMCG recordings, the reconstruction shows strong agreement with established reference methods. Conclusion: The proposed forward-model approach automatically reconstructs fetal and maternal cardiac activity from fMCG recordings and produces signals in an interpretable vectorcardiographic source domain. Significance: Automated, interpretable fMCG reconstruction could make fetal cardiac assessment more reliable and support potential translation into prenatal care.

0.50