CS Paper Radar

Automatic Cephalometric Landmark Localization on CBCT-Derived Digitally Reconstructed Radiographs for Skeletal Malocclusion Classification

Benjamin Hou, Konstantinia Almpani, Janice S. Lee, Zhiyong Lu

cs.CV ·submitted 2026-08-17 13:11 UTC · v1
published

Abstract

Manual cephalometric landmark annotation is important for craniofacial assessment but is labor-intensive and difficult to scale. We introduce CephViT, a Vision Transformer-based model for automated 2D lateral cephalometric landmark localization, and evaluate its use in downstream skeletal malocclusion classification. CephViT was trained and benchmarked on a public lateral cephalogram dataset, achieving a mean radial error of 1.28 +/- 1.42 mm and a successful detection rate of 92.0% at 3.0 mm. Because the private evaluation cohort consisted of 3D CBCT scans, lateral cephalogram-like digitally reconstructed radiographs (DRRs) were generated from each volume and used as 2D inputs to the landmark localization model. Landmark coordinates were normalized into a common coordinate frame, and skeletal malocclusion classification was performed using landmarks shared between the reference and DRR-based pipelines. Classification performance using DRR-localized landmarks was comparable to that obtained using manually annotated reference landmarks, with accuracies of 70.0% and 68.3%, respectively. These results support the feasibility of automated cephalometric analysis on CBCT-derived DRRs for skeletal malocclusion assessment.

Comment
Accepted for presentation at the ODIN 2026 Workshop, held in conjunction with MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Morphological Decoupling-Based Skeletal Classification for Clinical Assessment of Malocclusion

eess.IV cs.CV ·2026-09-09 ·Zhichun Jin, Zhicheng He, Hao Xu, Dongyang Li, Lin Wang +2 more
published similarity 0.65
Abstract · Accepted by Biocybernetics and Biomedical Engineering

Malocclusion skeletal grading is a fundamental task in orthodontics, critical for diagnosis and treatment planning. Traditionally, cone-beam computed tomography (CBCT) is used for visual measurement, and the reconstructed lateral cephalograms are handed over to expert dentists for diagnosis. However, manual review is time-consuming, labor-intensive, and subject to inter-operator variability. Therefore, an automatic CBCT-based system is needed for reliable malocclusion skeletal grading. In this case, we develop TeethGNN, a novel graph-based framework designed to combine CBCT image features with morphological information for accurate and efficient malocclusion grading. TeethGNN utilizes a decoupled learnable decoder to directly predict key morphological indicators from CBCT images, eliminating the need for manual measurements. These morphological features are then fused with image features using a graph neural network (GNN), which effectively models the relationships between the modalities. To further enhance robustness and calibration, we introduce a collaborative calibration strategy. This strategy combines multi-scale graph adversarial perturbation for explicit calibration and nonlinear topological graph calibration for implicit confidence adjustment. Extensive experiments and ablation studies on our collected clinical dataset demonstrate that our malocclusion measurement system achieves 77.08\% in accuracy and 89.61\% in AUC, outperforming the compared state-of-the-art methods. These results validate the effectiveness of graph-based multimodal fusion and collaborative calibration in improving malocclusion grading performance. Our system shows strong potential for advancing computer-aided orthodontic diagnosis, providing an accurate and reliable solution for vision-based clinical measurement and diagnosis.

0.36

Every Pixel Is an Option: A System One Model for Medical Ultrasound Biometry

cs.CV cs.LG ·2026-11-02 ·Moein Heidari, Junbo Rao, Yudan Chen, Yasamin Medghalchi, River Jiang +4 more
code/data similarity 0.58
Abstract

**Purpose:** Ultrasound biometry is widely used across various clinical applications, including prenatal and cardiac examinations, to obtain quantitative measurements by placing calipers at anatomical landmarks. However, these measurements remain subject to interoperator variability as they rely largely on manual caliper placement. Conventional methods often use specialized prediction heads for different ultrasound tasks, whereas vision-language models offer flexibility through text instructions. However, direct coordinate prediction does not explicitly model spatial likelihood distributions, limiting the representation of localization ambiguity. **Methods:** We propose Kev-Bio, a vision-language model that uses clinical measurement questions to guide ultrasound landmark detection. Inspired by System One decision models, Kev-Bio uses decision representations of the language model to generate queries for each caliper endpoint. These queries are matched against shared dense ultrasound features to produce spatial probability maps, from which landmark coordinates and clinical measurements are derived. The model is trained end-to-end using both landmark localization and clinical measurement losses. **Results:** On the nine-view FU/GU Biometry 2026 dataset, Kev-Bio achieves a mean radial error (MRE) of 22.50 pixels and a clinical measurement mean absolute error (MAE) of 15.38, outperforming the compared baselines in overall performance. **Conclusion:** These results demonstrate the effectiveness of Kev-Bio for ultrasound landmark detection and clinical measurement across different anatomical views. Our code and models are available at https://github.com/moeinheidari7829/Kev-Bio.

0.51

Rethinking Medical Landmark Localization with Prototype Learning-based Progressive Offset Correction

cs.CV cs.AIcs.LG ·2026-08-10 ·Jingxian Xu, Yuhao Huang, Rusi Chen, Yanfeng Zhou, Dong Ni
published similarity 0.58
Abstract · 10 pages, 4 figures, 3 tables. Accepted by MICCAI MLMI 2026

Accurate landmark localization in medical images is a fundamental step for quantitative clinical measurement and downstream analysis. Existing localization methods have advanced, among which multi-stage refinement is a superior solution. Although this strategy mitigates the anatomical ambiguity inherent in single-stage global predictions, its high computational cost limits practical applicability. In this work, we propose a parameter-economic model, PPOC-LL, which leverages Prototype learning-based Progressive Offset Correction for Landmark Localization. Our contribution is three-fold. First, to drive coarse-to-fine landmark optimization, we introduce a multi-scale dynamic perception strategy for patch-level feature pyramid modeling. Second, to effectively handle anatomically similar patterns, we design a similarity-driven prototype learning mechanism that captures informative local semantics for robust offset prediction. Last, to stabilize the model learning and improve the overall performance, we incorporate a novel error-aware reliability regularization via tolerance-based balancing. We collected a large validation cohort, including two public and one private datasets spanning X-ray and ultrasound modalities, covering cephalometric, symphysis-fetal head, and fetal heart landmarks. Extensive experiments demonstrate that PPOC-LL achieves satisfactory performance with a favorable trade-off between accuracy and model complexity.

0.33

Structure-aware Keypoint Localization for Videofluoroscopic Swallowing Study

cs.CV ·2026-10-06 ·Kai Zhou, Chuanshen Chen, Runhao Zeng, Meng Dai, Yifan Yang +4 more
publisheddatasetcode/data similarity 0.57
Abstract · Accepted by ICME 2026 Oral

Videofluoroscopic Swallowing Study (VFSS) is one of the gold standard for diagnosing swallowing disorders, providing dynamic X-ray imaging of the swallowing process. Automated kinematic analysis in VFSS relies fundamentally on precise anatomical keypoint localization. However, existing studies focus on limited keypoints (e.g., cervical vertebrae or the hyoid) and overlook critical regions such as the soft palate, while annotating only active swallowing segments and ignoring abundant non-swallowing data, resulting in poor data efficiency. Moreover, leveraging this unlabeled data via standard semi-supervised learning is suboptimal, as generic methods are prone to spatial bias. In medical X-rays with fixed layouts, models tend to memorize absolute coordinates rather than understanding anatomical structures. To tackle these challenges, we introduce VFSSKep, a novel dataset that extends annotations to the soft palate and incorporates large-scale unlabeled data. We further propose S$^3$KL, a Structure-aware Semi-Supervised Keypoint Localization framework designed to overcome spatial bias. It integrates a Structure-Aware Learning strategy to extract high-resolution structural cues for structure-aware representation learning, and a Structural Representation Consistency Learning strategy with block shuffling to enforce invariant structural recognition. Experiments show our method achieves state-of-the-art semi-supervised performance, even with unlabeled and 25% labeled data surpassing fully supervised learning with 100% labeled data. Code and data will be made publicly available at: https://github.com/kaai520/S3KL.

0.42

Raysemble: Metric 3D Bone Reconstruction from a Single X-ray

cs.CV ·2026-11-12 ·Xiaoyang Li, Xinghao Yan, Yuan Chai
similarity 0.55
Abstract

Raysemble reconstructs eight lumbar and pelvic bones from a single X-ray by separating shape and placement. Each 3D query samples regional and global features at its image projection. A shared decoder predicts normalized bone shapes. Predicted depth and camera geometry determine 3D centers and scales for resampling these shapes onto a common grid in millimeters. Evaluation uses 23 held-out patients with 43 CT scans, each generating one simulated anteroposterior radiograph. Without rigid alignment to CT,Raysemble leads 15 evaluated methods, averaging 65.24% Dice, 9.09 mm HD95, and 3.32 mm ASSD over three random seeds. With identical inputs, it improves Dice over VolumeNeRF by 5.86 percentage points.

0.22

Evaluating Transformation Models for pCLE Mosaic Registration

cs.CV ·2026-09-21 ·Ahmed Aboelela, Johannes Barcsay, Jana Friedhof, Miguel Gonçalves, Alexander Hann +1 more
similarity 0.55
Abstract

Confocal Laser Endomicroscopy (CLE) provides real-time, cellular-resolution optical biopsy but has a narrow field of view, which image mosaicing can extend to provide anatomical context. Because of line-by-line acquisition, probe motion, and probe-tissue interaction, frame alignment generally requires a non-linear transformation whose accuracy is difficult to quantify: flexible transformation models can fit intensity features and noise, so appearance-based metrics such as Normalized Cross-Correlation (NCC) can improve without a genuine gain in geometric accuracy. We therefore establish a dataset of 132 frame pairs across fourteen pCLE sequences from 4 patients with manually annotated landmark correspondences, so that Target Registration Error (TRE) can serve as a geometrically grounded complement to NCC. We assess the effect of progressively increasing the transformation model's degrees of freedom, from translation to Thin Plate Spline (TPS), and of six feature-matching backends spanning classical (Shi-Tomasi, Lucas-Kanade) and learned (SuperPoint, SuperGlue, LightGlue, LoFTR, RoMa) approaches. Translation and rigid models prove insufficient under tissue deformation, while TPS with random sampling achieves the strongest landmark-derived alignment of the evaluated configurations; among the learned matchers, used without fine-tuning, only RoMa offers a robust, if modest, advantage over other methods. At the sequence level, pairwise registration quality proved an unreliable predictor of final mosaic quality, so mosaic quality must be evaluated directly rather than inferred from pairwise metrics.

0.34

Automated Fetal Brain MRI Biometry in Healthy and Pathological Cases

cs.CV ·2026-08-16 ·Ema Masterl, Tina Vipotnik Vesnaver, Nejc Šubič, Žiga Špiclin
published similarity 0.54
Abstract · Accepted at the PIPPI Workshop of MICCAI 2026

Automated biometric analysis of fetal brain MRI enables reproducible, observer-independent quantitative assessment, yet existing methods are often restricted to few measurements or evaluated only on healthy cases. We assemble and evaluate an automated biometric analysis pipeline that localizes 22 anatomical landmarks on NeSVoR-reconstructed 3D volumes and derives 11 clinically relevant measurements spanning supratentorial, ventricular, cerebellar, and midline structures. We compare two landmark localization models, H3DE-Net and SCN, on a heterogeneous cohort of 122 acquisitions (both healthy controls and range pathologies). Localization accuracy was assessed with a linear mixed-effects model, agreement with normative growth trajectories with calibrated centile charts, and diagnostic utility with a decision tree classifying VM severity. H3DE-Net achieved significantly lower localization error than SCN across all landmarks (mean 1.36 mm vs. 3.58 mm in HC and 1.90 mm vs. 4.13 mm in PC; p < 0.001), and outperformed a GA-based regression baseline in 7 of 11 measurements. H3DE-Net measurements yielded higher classification AUC in every diagnostic group, with the clearest advantage in separating healthy controls from VM. Decision tree thresholds for ventricular width fell near the clinical 10 mm and 15 mm cut-offs used to define and grade VM.

0.18

Detection is solved, delineation is not: what governs tooth segmentation on panoramic radiographs

cs.CV cs.LG ·2026-09-18 ·Muhammad Rehan, Moaz Amjad, Syed Danial Ahmed, Mariam Adnan, Haider Ali
code/data similarity 0.54
Abstract · 15 pages, 6 figures, 5 tables. Code: https://github.com/Rehan000/opg-tooth-segmentation

Automatic tooth segmentation and FDI numbering on panoramic radiographs underpins computer-assisted dental diagnosis, yet which factors govern performance remains unclear. We assemble a corpus of 1,422 panoramic radiographs containing 42,142 expert-delineated tooth polygons across the 32-class FDI taxonomy, annotated by 30 dental practitioners and independently reviewed by two others, and use it to isolate input resolution, architecture and anatomical priors under a single evaluation protocol. First, resolution dominates: across a controlled 640/1024/1280 ablation, mask mAP50-95 rises 0.656 -> 0.710 -> 0.717 while mAP50 stays flat at ~0.982. Both gains are significant under a paired bootstrap over images (p < 0.001, p = 0.024); neither mAP50 change is distinguishable from zero. Added resolution buys boundary precision, not detection. Second, architecture is nearly irrelevant in-domain: a query-based transformer with 2.1x the parameters is statistically equivalent to a one-stage detector (95% CI [-0.0064, +0.0064]), only marginally better under domain shift, 5.5x slower on CPU and not executable under standard ONNX runtimes. Third, three targeted interventions fail: a LoRA-adapted self-supervised encoder underperforms, a promptable foundation segmenter degrades masks by 39%, and globally optimal anatomical label assignment yields +0.0007 despite correcting a constraint violated in 40% of out-of-domain predictions. Zero-shot transfer to an independent multi-centre cohort, verified overlap-free, costs 62% of mask mAP50-95 but only 18% of mAP50, reproducing the dissociation. Decomposing masks along the tooth axis localises the residual error to the apical third. Boundary precision is therefore the binding constraint, and effort is better directed at resolution and acquisition diversity than at architectural novelty.

0.36