CS Paper Radar

Daily listing

2026-08-28 · eess.SP

20 papers first submitted this day (UTC) in eess.SP — Signal Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 3

mmIR: Frequency-Space Inverse Rendering for 3D Millimeter-Wave Radar ADC Synthesis

cs.CV cs.GRcs.LGeess.SP ·2026-08-28 ·Adnan Armouti, Yixuan Gao, Rajalakshmi Nandakumar
top venuecode/data
Abstract · Accepted to the European Conference on Computer Vision (ECCV) 2026. Project page: https://mmwave-inverse-rendering.github.io/

High-resolution 3D radar data is scarce. Commodity mmWave sensors use small antenna arrays that limit angular resolution to several degrees, and existing datasets provide only 2D range-azimuth maps or sparse point clouds rather than raw analog-to-digital converter (ADC) signals. Hardware scaling is expensive, synthetic-aperture scanning is impractical at fleet scale, and learned synthesis methods are bottlenecked by the very data shortage they aim to address. We present mmIR, an open-source differentiable frequency-modulated continuous-wave (FMCW) radar inverse renderer that fits a physics-based forward model to real captures and re-renders from dense virtual apertures to synthesize high-resolution 3D radar data. Because radar resolution is too coarse to recover geometry directly, mmIR performs LiDAR-assisted inverse rendering: using LiDAR-derived meshes as a geometric scaffold, mmIR optimizes per-vertex International Telecommunication Union (ITU) physics materials, vertex normals, and antenna beam patterns through end-to-end automatic differentiation of a phase-coherent multiple-input multiple-output (MIMO) forward model with multi-bounce propagation, polarization, and free-space diffraction. On seven outdoor and six indoor ColoRadar scenes, mmIR achieves 0.914 mean Pearson correlation on range-azimuth maps versus 0.307 for Sionna-RT. Scenes trained on a cascaded imaging radar transfer to a co-located single-chip radar without re-training (0.554 correlation), and dense virtual arrays (100x100 elements) produce single-frame 3D occupancy validated against LiDAR. Project page: https://mmwave-inverse-rendering.github.io/

0.75

Accurate Plate Reverb Parameter Estimation Using Two-Stage Evolutionary Search

eess.AS cs.SDeess.SP ·2026-08-28 ·Byunghoo Park, Jayeon Yi, Takyoung Kim, Minje Kim
publishedunusual
Abstract · Accepted as a challenge paper at the 29th International Conference on Digital Audio Effects (DAFx), Cambridge, MA, USA, 2026

We describe our submission to Task A of the 1st DAFx parameter estimation challenge. The task is to recover the six physical parameters of a simulated metal-plate reverberator -- its dimensions and material properties -- from a single impulse response (IR). We treat this as a black-box optimization: candidate parameter sets are fed to the simulator and scored by a loss against the target IR. The method has two stages. The first uses CMA-ES, an evolutionary optimizer, to recover five of the six parameters, comparing IRs under an amplitude-normalized loss. Amplitude normalization makes the search robust but discards the cue to the sixth parameter, the plate's surface density; a second stage therefore estimates it alone, with a ternary search on the un-normalized loss. As the choice of loss strongly affects the search, we select it beforehand, and analyze why compression in the common multi-scale spectral loss degrades recovery. Finally, we test our method on a validation set of 50 IRs, discuss a pathological failure mode, and ablate to justify having two different stages instead of a unified CMA-ES search.

0.51

Patch-Based Diffusion Reconstruction for Accelerated Cardiac Cine

eess.IV eess.SP ·2026-08-28 ·Xuan Lei, Philip Schniter, Juliet Varghese, Rizwan Ahmad
Abstract

Purpose: To develop and evaluate a diffusion-based reconstruction framework for highly accelerated 2D real-time (RT) cine cardiovascular magnetic resonance imaging (CMR). Methods: We trained an unconditional patch-based diffusion model and incorporated it into a reconstruction framework, termed CineDiff, using diffusion posterior sampling for data consistency. CineDiff was evaluated in four settings: (i) 30 retrospectively undersampled breath-held cine at 1.5T and 3T from healthy participants across multiple acceleration rates, (ii) 15 prospectively undersampled free-breathing RT cine at 1.5T and 3T from patients indicated for clinical CMR, and (iii) 10 prospectively undersampled mid-field (0.55T) free-breathing scans, including five from healthy subjects and five from porcine models. For retrospective undersampling, reconstruction quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), learned perceptual image patch similarity (LPIPS), and deep image structure and texture similarity (DISTS). For prospective undersampling, image quality was evaluated by blinded expert scoring on a 5-point Likert scale. Results: In retrospectively undersampled breath-held cine data, CineDiff achieved higher PSNR and SSIM and lower LPIPS and DISTS than the comparison methods across all evaluated acceleration rates. In prospectively undersampled free-breathing RT cine data, CineDiff received higher expert image-quality scores. Qualitatively, CineDiff reduced block-like artifacts and preserved finer anatomical detail compared with traditional compressed sensing and a variational network method, termed CineVN. Conclusion: CineDiff enabled high-quality reconstruction of highly accelerated 2D RT cine CMR. The method also demonstrated robustness to out-of-distribution data, including mid-field and porcine acquisitions.

0.33