CS Paper Radar

Daily listing

2026-11-24 · q-bio.QM

4 papers first submitted this day (UTC) in q-bio.QM — q-bio.QM. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 2

DDxBasis: Explaining Frozen Foundation Encoder-based Medical Classification by Exact Differential Diagnosis

cs.CV q-bio.QM ·2026-11-24 ·Luojie Huang, Gregory N. McKay, Nicholas J. Durr
code/data
Abstract · Project page: durrlab.github.io/DDxBasis

In differential diagnosis (DDx), a clinician explains a diagnosis by the few findings that separate it from the alternatives. Medical image classifiers cannot yet explain themselves this way. Existing explanations are either faithful but spread over hundreds of concepts, or compact but leave part of each decision unexplained. We present DDxBasis, which explains a classifier on a frozen foundation encoder as a differential diagnosis in three steps. First, a concept bottleneck reads all patch tokens at every encoder layer using gated, second-order slot attention. A concept basis then regroups the concepts into two-pole axes, each a differential between groups of diagnoses. Finally, we read a differential diagnosis from each axis through the typical presentation of its poles, the pertinent findings of the case, and counterfactual edits of borderline cases. Across five medical datasets, DDxBasis is the most accurate frozen-encoder model and close to the best published domain-specific results. Because every concept adds its own evidence, its reproducible concept basis splits each decision exactly, at no cost in accuracy. Without ordered stage or concept labels, the axes recover cell lineages and rare subtypes, agree with dermatologists' structure annotations, and expose planted and real shortcuts.

0.38

Longitudinal Characterization of Personalized Hydration Dynamics Using a Facial-Video Digital Hydration Biomarker

cs.CV q-bio.QM ·2026-11-24 ·Janindu Athukorala, D. M. J. Prathapa, Thanveer Ahamed, Yudara Kularathne
Abstract · 18 pages, 8 figures, 5 tables

Background. Hydration is often assessed at a single time point despite continuous changes in body water. A facial-video biomarker has tracked hydration-state transitions, but its longitudinal behavior is unclear. Objective. To assess within-person hydration score changes, individual differences in fluid response, and implications for personal calibration. Methods. Five adults completed water and electrolyte days with an identical 2.0 L fluid schedule, using facial videos every 30 minutes over 12 hours (250 videos). On a separate morning, each completed a 500 mL electrolyte challenge with baseline and four follow-up videos over 2 hours (25 videos). Analyses assessed trajectories, post-drink changes, variability, time at or above score 50, and exploratory effects of starting score and beverage day. Results. The first scan was the day's lowest on 7 of 10 days. Across 50 intakes, the mean post-drink change was +4.0 points, exceeding a shuffled-time comparison (p less than 0.001). For 21 intakes starting below 50, no subsequent score fell; the mean rise was +11.3 points versus +5.7 expected under permutation (p less than 0.001). Intakes starting at 50 or above showed no rise beyond chance. After 500 mL electrolytes, mean change over 2 hours was positive for all five participants, with peak increases of 7.2 to 22.6 points at 30 to 90 minutes. Despite identical fluid schedules, time at or above 50 ranged from 16% to 100%. The electrolyte day showed a greater mean increase from morning baseline than the water day (+7.7 points), although day order was fixed. Conclusion. Facial-video hydration scores showed longitudinal changes associated with drinking and marked individual differences. These exploratory findings support further research on personal calibration and hydration protocols in larger controlled studies.

0.11