CS Paper Radar

Daily listing

2026-08-21 · eess.IV

7 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 7

MDFI: A Multi-Domain Features Integration for Compressed Video Quality Enhancement

eess.IV cs.CV ·2026-08-21 ·Sang NguyenQuang, Hieu Bui Minh, Dang BuiDinh, Xiem HoangVan
top venuedatasetcode/data
Abstract

The latest video coding standard, H.266/VVC, has demonstrated significant improvements in compression efficiency compared to H.265/HEVC. Despite its advanced coding techniques, H.266/VVC still faces challenges in meeting the increasing demand for higher perceptual quality and enhanced compression performance. To address these limitations, we propose MDFI (Multi-Domain Features Integration), a compressed video quality enhancement approach that features a novel Frame-Prediction Feature Transform (FPFT) module to process prediction information. Moreover, MDFI integrates a multi-domain feature fusion strategy that effectively combines spatiotemporal characteristics, cross-frequency representations, and compressed-domain prediction information to enhance decoded video quality. Additionally, we introduce a comprehensive dataset that encompasses uncompressed video sequences, corresponding reconstructed versions at multiple QP levels, and predicted frames generated from H.266/VVC compressed bitstreams, providing essential resources for developing and benchmarking video enhancement approaches. Extensive experiments demonstrate that our MDFI approach achieves superior performance to state-of-the-art methods in both objective metrics and visual quality, effectively mitigating video compression artifacts. The code is available at: https://github.com/dangdinh17/MDFI.git.

0.75

CHIMERA Challenge: Biochemical Recurrence Prediction in Prostate Cancer Patients using multimodal datasets

eess.IV cs.CV ·2026-08-21 ·Robert N. Spaans, Catherine Chia, Tongjie Wang, Adam Kowalewski, Parandzem Khachatryan +5 more
benchmark
Abstract · 38 pages, 3 figures, 3 supplementary figures. Preprint submitted to Medical Image Analysis. Challenge results presented at the CHIMERA works…

Biochemical recurrence (BCR), defined as any detectable prostate-specific antigen level after prostatectomy with confirmatory elevation, is widely used as a surrogate endpoint and typically assessed using clinical and pathological variables. Currently, no standardized benchmark exists for multimodal prognostic modeling in urological cancers, partly because curating heterogeneous multimodal data remains challenging. We developed the CHIMERA Challenge, a multimodal benchmark integrating preoperative mpMRI, post-prostatectomy histopathology, patient characteristics, and clinician-derived variables from 267 patients across two institutions. The dataset comprises 801 MRI sequences, 13 clinical variables per case, and 942 WSIs. Training (n=95), validation (n=23), and test (n=149) splits were established and hosted on the Grand Challenge platform. Baseline clinical and pathological characteristics did not differ significantly across splits. Models were evaluated on predicting time to BCR using the C-index. Post-challenge analyses tested how each model type performed when clinician-derived variables were withheld or randomized. Unimodal clinical models achieved the highest test C-index of 0.7402 but proved sensitive to the integrity of these variables, with performance collapsing toward chance (C approximately 0.50) when they were randomized. Multimodal models retained near-baseline performance when these variables were withheld (delta C at most 0.04), indicating their ability to recover prognostic signal directly from imaging data. CHIMERA is the first public, standardized multimodal benchmark for prostate cancer prognosis. Although models using only patient characteristics and clinician-derived variables yielded the highest leaderboard performance, multimodal models demonstrated greater robustness in clinically realistic scenarios where complete expert annotation is not guaranteed.

0.47

FlowSem: Flow Matching for Adaptive Wireless Image Transmission in Semantic Communication

eess.IV ·2026-08-21 ·Arnab Emon, Eslam Eldeeb
Abstract

Wireless image transmission becomes challenging under poor channel conditions and stringent bandwidth constraints, as the receiver needs to preserve both pixel-level fidelity and meaningful visual structure. Classical separation-based systems, such as better portable graphics with low-density parity-check coding (BPG+LDPC), may suffer from cliff-effect behavior. While deep joint source-channel coding (DeepJSCC) provides graceful degradation as channel conditions worsen, its reconstructions may lose fine details under strong compression and severe channel distortion. To address this limitation, this paper proposes a two-stage flow matching-based semantic communication framework, termed FlowSem. In the first stage, a signal-to-noise ratio (SNR)-adaptive DeepJSCC model maps the source image into channel symbols and produces a coarse reconstruction at the receiver. In the second stage, a conditional flow matching model generates the final image from Gaussian noise conditioned on the DeepJSCC reconstruction and channel SNR. The proposed framework is evaluated on the Cityscapes dataset under additive white Gaussian noise (AWGN) and Rayleigh fading channels using a fixed channel-symbol budget. The baselines include a rate-matched BPG+LDPC system, DeepJSCC, a denoising diffusion probabilistic model (DDPM), and a denoising diffusion implicit model (DDIM). Results show that FlowSem achieves competitive pixel-level fidelity and improved structural and perceptual reconstruction quality over the considered generative baselines across different channel conditions. FlowSem provides up to 60% lower Fréchet Inception Distance (FID) than the diffusion baselines at low SNRs. Moreover, FlowSem reaches high reconstruction quality using only a few ODE integration steps, providing a favorable quality-latency tradeoff compared with standard DDPM and accelerated DDIM sampling.

0.36

Reliability- and Anatomy-Consistency-Aware Multimodal Learning for Robust Fracture Classification from Bangladeshi Radiographs

eess.IV cs.AIcs.CV ·2026-08-21 ·Musa Tur Farazi, K G Subarno Bithi
hot direction
Abstract

Background: Multimodal fracture classifiers may benefit from patient and anatomical metadata, but they can also become brittle when contextual information is missing or mismatched. Methods: We studied 1493 radiographs from the Bangladeshi OrthoFrac-XR dataset using leakage-safe age, sex, bone type, and laterality. A ConvNeXt image encoder was combined with a clinical multilayer perceptron through concatenation, late fusion, reliability-gated residual fusion, and a hierarchical state-location formulation. We additionally introduced an anatomy-consistency gate that attenuates metadata corrections when an image-side anatomical prediction disagrees with the reported bone type. Results: Across five folds and three seeds, hierarchical residual fusion achieved a macro-F1 of 0.6046 +/- 0.0279, compared with 0.5727 +/- 0.0270 for image-only learning, while improving the Brier score from 0.5239 to 0.4948. In a five-fold robustness experiment, anatomy-consistency fusion reduced the macro-F1 loss under shuffled metadata from 0.0567 to 0.0203 relative to ordinary residual fusion, although its clean-data macro-F1 was lower. Without bone type at inference, auxiliary anatomy supervision improved macro-F1 from 0.5620 +/- 0.0330 to 0.5899 +/- 0.0289. Conclusions: Structured context improves fracture classification, and consistency-aware gating limits harm from mismatched metadata. The observed clean-performance-robustness trade-off and the absence of patient-level identifiers motivate external and prospective validation.

0.34

Toward Vision Language Model-based Assessment of Clinical Quality and Usability of LGE-MR Images for Cardiac Ablation Planning

eess.IV cs.CV ·2026-08-21 ·Bipasha Kundu, Abhishek Chaturvedi, Axel W. E. Wismueller, Richard Simon, Cristian A. Linte
benchmark
Abstract

LGE cardiac MRI is widely used for left atrial fibrosis assessment and ablation planning in atrial fibrillation patients as knowledge of fibrotic tissue regions identified from LGE-MRI is critical for catheter ablation. Often, poor quality images used during ablation planning can cause mis-localization of ablation targets, directly impacting procedure safety and outcome. The decision of whether a scan meets the minimum quality threshold for ablation planning is currently made informally by the reviewing radiologist and is not captured by any automated system, yet it is arguably the most safety-critical output of the image quality assessment (IQA) process. However, variations in image quality caused by noise, motion artifacts, and poor boundary definition significantly compromise the reliability of downstream segmentation and clinical decision-making tasks. Manual quality assessment by expert radiologists is subjective and difficult to scale, while existing automated methods produce scalar scores without interpretable clinical reasoning. In this work, we propose a two-stage vision language model (VLM) framework for clinically grounded image quality assessment of left atrial LGE-MRI. In the first stage, a fine-tuned VLM generates structured radiology-style quality reports predicting five radiologist-defined criteria: Noise, Motion Artifact, LA Boundary Accuracy, PV Region Accuracy, and Under-segmentation Severity. In the second stage, a GPT-based reasoning module maps the predicted quality and reports to a structured quality scores and binary clinical usability decision for ablation planning. We curate a dataset of 60 annotated image slice-text pairs from 20 patients and benchmark four state-of-the-art VLM architectures. InternVL2 achieves the highest criterion-level accuracy (Avg ACC=0.65, PLCC=0.79), while DeepSeek achieves perfect clinical usability agreement (Acc=1.00, kappa=1.00).

0.27

Image Denoising Using Lower Semi-Frames

eess.IV cs.CV ·2026-08-21 ·Hemalatha M, P. Sam Johnson
Abstract

A blind image denoising framework based on an infinite directional lower semi-frame (DLSF) is proposed for additive white Gaussian noise. The model employs scale-dependent directional analysis with resolvent regularization of the unbounded semi-frame operator. Noise variance is estimated directly in the DLSF domain by modeling the joint covariance of four directional difference channels and applying covariance whitening to obtain a chi-square statistic. A lower-tail moment estimator provides blind noise estimation without median absolute deviation. The estimated noise level is incorporated into channel-wise Wiener-type shrinkage and canonical-dual synthesis, followed by a data-consistent iterative reconstruction with automatic stopping. Experiments on three standard grayscale images at noise levels 15--30 yield a mean relative noise-estimation error of 3.28\%, with average improvements of 7.45 dB in PSNR and 0.367 in SSIM. At 30/255 noise, the estimation error decreases to 1.73\%, with a mean PSNR gain of 8.31 dB. Results demonstrate effective noise suppression and structural preservation, with the strongest performance on smooth and edge-dominated images.

0.27

Multimodal pseudo-CT synthesis for PET attenuation correction using separate modality encoding and topogram conditioning

eess.IV cs.CVphysics.med-ph ·2026-08-21 ·Rory Bell, Artemis Bouzaki, Jiaming Cao, Jasmine Morrison, Chelsea Sargeant
code/data
Abstract · Technical report for the BIC-MAC 2026 Challenge

We participated in the BIC-MAC Challenge with a multimodal 3D patch-based U-Net for pseudo-CT generation from NAC-PET, MRI, and 2D topograms. By using separate PET and MR encoders, multi-scale feature fusion, and FiLM-based topogram conditioning at the bottleneck, we obtain a model that integrates complementary cross-modal information while reducing reliance on precise voxel-wise correspondence between modalities. Our final submission can be found: https://github.com/rrr-uom-projects/BIC-MAC-MICCAI2026

0.17