CS Paper Radar

Daily listing

2026-09-04 · eess.IV

4 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 3

Real-World Multi-Modal and Longitudinal Lung Cancer Dataset

eess.IV cs.CV ·2026-09-04 ·Rita Cordeiro Mendes, Maria Rita Fonseca Verdelho, Carlos Santiago, Catarina Barata
publishedbenchmarkcode/data
Abstract · Accepted at ECCV 2026 Workshop on Data Curation & Augmentation in Medical Imaging

Multi-modal learning has demonstrated strong potential in medical applications by integrating heterogeneous data sources such as medical imaging, clinical records, and genomics to improve predictive performance and support clinical decision-making. However, advances in this area are often constrained by two key challenges: the limited availability of well-curated, ready-to-use datasets that accurately reflect real-world conditions, where medical data are frequently collected inconsistently and are often incomplete; and the inherent difficulty of integrating heterogeneous data modalities. In this work, we introduce a newly curated multi-center, multi-modal, and longitudinal dataset designed to support the evaluation of a wide range of learning pipelines under realistic conditions. The dataset comprises a total of 1,365 lung cancer patients and has three imaging modalities (whole-slide images, CT scans, and PET scans), structured clinical data, transcriptomic, and longitudinal follow-up and treatment information. For each imaging modality the dataset contains more than one instance. Moreover, the dataset exhibits substantial and non-uniform missingness across modalities, making it well-suited for studying robust multi-modal fusion strategies. We further provide both uni-modal and multi-modal benchmarks on the task of 12-month overall survival prediction, disease-specific survival, as well as longitudinal benchmark of hazard prediction under severe missing data. Our results show that, despite high levels of missingness, integrating complementary modalities consistently improves predictive performance over uni-modal approaches, highlighting the value of multi-modal fusion in realistic clinical settings. The dataset and benchmark code are available at https://github.com/ritacmendes/MMIST-LUNG.

0.33

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

eess.IV cs.CV ·2026-09-04 ·Nazim-E-Alam
Abstract

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

0.26

ViT3Flow: A Test-Time Training Transformer MeanFlow for Postoperative Radiograph Synthesis in Scoliosis

cs.CV cs.AIeess.IV ·2026-09-04 ·Rui Tang, Sicheng Yang, Moxin Zhao, Hongqiu Wang, Guankun Wang +4 more
Abstract

Predicting postoperative spinal morphology from preoperative radiographs could provide valuable support for scoliosis surgical planning, but remains challenging because surgical correction induces large spatial changes while anatomical structures must be faithfully retained. We formulate this problem as postoperative scoliosis radiograph synthesis and construct ScoliSurg, the first paired dataset for this task, comprising 632 preoperative--postoperative whole-spine radiograph pairs with structured morphology information. We further propose ViT$^{3}$Flow, a single-NFE conditional MeanFlow framework for efficient postoperative radiograph synthesis. ViT$^{3}$Flow models surgical correction as finite-interval generative transport and replaces conventional self-attention with test-time-training token mixers that perform sample-specific inner adaptation to the anatomy and deformity pattern of each case. In addition, a Spinal Morphology Extraction Agent extracts distributions of dominant-curve region and direction from the preoperative radiograph. These distributions guide Diagnosis-Routed Interval Cross-Attention (DRICA), which performs interval-dependent vertical, horizontal, joint, and global retrieval from a separate preoperative token stream. This design enables the evolving postoperative representation to incorporate spatially corresponding anatomical evidence throughout the transport process. Extensive experiments on ScoliSurg demonstrate that ViT$^{3}$Flow achieves the best performance among the compared methods in perceptual image quality, anatomical fidelity, and clinically relevant geometric accuracy, while requiring only a single network evaluation. These results highlight the potential of ViT$^{3}$Flow for efficient and anatomically faithful postoperative radiograph synthesis in scoliosis surgical planning.

0.22

Systems & Networking 1

A Piecewise-Linear Approximation-based Energy-Efficient Error-Optimized Unsigned Square Rooter for Accuracy-Critical Applications

cs.AR eess.IV ·2026-09-04 ·Prateek Goyal, Sujit Kumar Sahoo
benchmark
Abstract · OK

Approximate computing improves energy efficiency in error-resilient applications, but square root units remain challenging due to the trade-off between hardware cost and computational accuracy. This paper presents an energy-efficient, error-optimized, piecewise-linear approximation-based unsigned square rooter (EOSQR) for 2n-bit inputs that achieves high accuracy with low hardware complexity, using only simple arithmetic and shift operations. The EOSQR design is implemented in Verilog-HDL and evaluated on a 16-bit benchmark synthesized on an Artix-7 FPGA. Compared to representative state-of-the-art approximate square rooters, EOSQR achieves the lowest error among accuracy-critical designs while delivering 61.91 percent resource savings, 77.54 percent power savings, and 53.11 percent latency reduction relative to a precise restoring array-based square rooter. To enable holistic evaluation, a Composite Efficiency Metric (CEM) is introduced to jointly capture accuracy and energy efficiency. EOSQR is further validated across representative image-processing workloads, including Sobel edge detection, K-means colour quantization, and K-nearest-neighbour (KNN) classification. Experimental results demonstrate that EOSQR achieves high computational accuracy with a superior CEM-based accuracy-hardware efficiency trade-off while maintaining visual quality and classification performance, making it well-suited for real-time edge-embedded systems.

0.35