CS Paper Radar

ViT3Flow: A Test-Time Training Transformer MeanFlow for Postoperative Radiograph Synthesis in Scoliosis

Rui Tang, Sicheng Yang, Moxin Zhao, Hongqiu Wang, Guankun Wang, Lei Zhu, Hongliang Ren, Menglin Cong, Nan Meng

cs.CV cs.AIeess.IV ·submitted 2026-09-04 12:14 UTC · v1

Abstract

Predicting postoperative spinal morphology from preoperative radiographs could provide valuable support for scoliosis surgical planning, but remains challenging because surgical correction induces large spatial changes while anatomical structures must be faithfully retained. We formulate this problem as postoperative scoliosis radiograph synthesis and construct ScoliSurg, the first paired dataset for this task, comprising 632 preoperative--postoperative whole-spine radiograph pairs with structured morphology information. We further propose ViT$^{3}$Flow, a single-NFE conditional MeanFlow framework for efficient postoperative radiograph synthesis. ViT$^{3}$Flow models surgical correction as finite-interval generative transport and replaces conventional self-attention with test-time-training token mixers that perform sample-specific inner adaptation to the anatomy and deformity pattern of each case. In addition, a Spinal Morphology Extraction Agent extracts distributions of dominant-curve region and direction from the preoperative radiograph. These distributions guide Diagnosis-Routed Interval Cross-Attention (DRICA), which performs interval-dependent vertical, horizontal, joint, and global retrieval from a separate preoperative token stream. This design enables the evolving postoperative representation to incorporate spatially corresponding anatomical evidence throughout the transport process. Extensive experiments on ScoliSurg demonstrate that ViT$^{3}$Flow achieves the best performance among the compared methods in perceptual image quality, anatomical fidelity, and clinically relevant geometric accuracy, while requiring only a single network evaluation. These results highlight the potential of ViT$^{3}$Flow for efficient and anatomically faithful postoperative radiograph synthesis in scoliosis surgical planning.

Closest papers

Nearest neighbours by meaning across the whole index.

ARNAI: Artifact Removal Network based on Autoencoding and Inpainting for Robust Spinal Image Segmentation and Measurement

cs.CV cs.AI ·2026-09-07 ·Sang-Jin Park, Jinyoung Choi, Seokwon Kim, Seungeon Song, Insu Park +11 more
top venue similarity 0.60
Abstract · 12 pages 4 figures

Purpose: This study aims to develop an AI framework applicable for postoperative imaging for automated measurement of spinopelvic parameters on radiographs with robustness to the presence of spinal implants. Materials and Methods: We retrospectively reviewed lateral lumbar spine radiographs from two institutions (Internal: January 2017--December 2024; External: October 2021--September 2025). We developed the Restore, Segment, and Measure (RSM) framework, incorporating a novel Artifact Removal Network based on Autoencoding and Inpainting (ARNAI) to mitigate implant-related artifacts in postoperative radiographs. Segmentation and spinopelvic parameter (PT, LL, SS, SCA) measurement performance were assessed using Wilcoxon signed-rank tests and intraclass correlation coefficients. Results: When ARNAI was added to a recent Transformer-based segmentation model, FCBFormer, the mean DSC increased to 0.870 from 0.814, with marked gains at L3--L5 and smaller improvements at L1--L2. On 91 radiographs with implants, the mean L4--L5 segmental Cobb angle error decreased to 4.7 ° from 15.6--16.2 °, an average error reduction of 70%. The ICC for L4--L5 segmental Cobb angle improved to 0.54 (Rater 1) and 0.59 (Rater 2) from 0.18, and ICCs for pelvic tilt, lumbar lordosis, and sacral slope all exceeded 0.70. The improvement in L4--L5 segmental Cobb angle error was statistically significant in the internal implant-containing cohort after correction for multiple comparisons. Conclusion: The proposed RSM framework improved automated spinopelvic parameter measurement in implant-containing postoperative radiographs. By mitigating implant-related artifacts, ARNAI improved segmentation and downstream measurement accuracy, with the greatest benefit observed for L4--L5 segmental Cobb angle estimation, where the mean error was reduced by approximately 70%.

0.51

GateSPINE: Gated Cross-View Fusion for Lumbar Spine MRI Report Generation

cs.CV cs.AI ·2026-09-30 ·Hoang Nguyen Van, Cuong Vuong Tuan, Trang Mai Xuan, Bien Tran Van, Nam Tran Van +1 more
similarity 0.59
Abstract

Automated report generation can ease the burden radiolo gists face when interpreting multi-sequence MRI studies. Unlike CT, MRI examinations comprise multiple sequences and imaging planes, each con tributing complementary diagnostic information. Existing methods en code a study as a single volume and combine multiple acquisitions by fixed rules. Findings visible in only one plane are thus diluted and of ten missed, lowering recall on clinical efficacy metrics, where a missed abnormality is most costly. We propose GateSPINE, a vision-language framework that fuses sagittal T1 and T2 volumes with a training-free operator, encodes the fused sagittal and axial volumes with two parallel 3D encoders, and decodes their combined representation into a report. Its core mechanism is a gated cross view fusion module that predicts, per feature channel and token, how much of each view to admit, so the more informative view dominates at each spatial location. We evaluate GateSPINE on three lumbar MRI datasets, comprising two public bench marks and a private cohort collected from Phenikaa University Hospital, using both natural language generation (NLG) and clinical efficacy (CE) metrics. GateSPINE achieves the highest CE F1 through improved re call on all three datasets; on SPIDER, which lacks an axial sequence, this reflects the sagittal fusion component rather than the gated cross-view mechanism, which is validated on the two cohorts with both imaging planes. GateSPINE also remains competitive on standard NLG metrics.

0.22

THA-Flow Generative Model: Prosthesis Geometry Prediction from Preoperative CT

cs.CV ·2026-08-26 ·Yiping Wang, Jie Li, Jingyu Shen, Liao Wang
similarity 0.59
Abstract · 17 pages, 7 figures, 2 tables

Preoperative planning for total hip arthroplasty (THA) is commonly framed as selecting a single prosthesis configuration and placement for a patient's osseous anatomy. In practice, however, the same anatomy may admit several clinically reasonable solutions, making planning inherently a one-to-many problem that is better represented by a conditional probability distribution. We present THA-Flow, a conditional flow-matching model that generates three-dimensional prosthesis geometry directly from preoperative CT. Separate AutoencoderKL models compress preoperative bone anatomy and prosthesis geometry, while a three-dimensional UNet learns a rectified flow from Gaussian noise to the prosthesis latent space under spatial bone conditioning and optional structured prosthesis parameters. The retrospective cohort comprised 1,355 hips from 1,149 patients undergoing primary THA. Following rigid registration of postoperative CT to preoperative CT, the actual postoperative prostheses were transformed independently according to the pelvic and femoral registrations and represented as a dual-channel truncated signed distance field. The prosthesis autoencoder achieved a peak signal-to-noise ratio of 47.11 dB and a structural similarity index of 0.9964 on the validation set. Complete acetabular and femoral geometries were generated across seven major stem models representing 93.4% of the cohort. Repeated bone-conditioned sampling preserved component position, alignment, and the principal bone-prosthesis interfaces while allowing limited local geometric variation. To our knowledge, THA-Flow represents the first application of generative AI to three-dimensional surgical planning for THA.

0.28

TokenSTFormer: A Tokenized Spatial-temporal Attention Model for Holistic Motion Analysis in Adolescent Idiopathic Scoliosis Screening

cs.CV cs.AIcs.LG ·2026-08-17 ·Dong Chen, Kenneth M. C. Cheung
dataset similarity 0.58
Abstract

Adolescent Idiopathic Scoliosis (AIS) is a prevalent spinal deformity in adolescents that, if left untreated, can result in severe health outcomes. Traditional screening methods are limited by subjective interpretation, reliance on professional expertise and low scalability. To address these challenges, we present ScoliGait dataset, which comprises 1,516 gait video clips paired with corresponding X-ray records. We also introduce TokenSTFormer, a novel model that tokenizes spatial and temporal semantics to enhance feature representation and convergence. Our model achieves state-of-the-art performance, surpassing vanilla Vision Transformer encoder across key metrics, including accuracy of 0.79. This study highlights the potential of leveraging holistic motion features derived from gait video and attention-based models for scalable, cost-effective AIS screening, paving the way for future clinical applications in scoliosis detection.

0.35

Prompt-Guided Interactive Segmentation of Interstitial Lung Disease in Thoracic CT

cs.CV ·2026-08-28 ·Vasilis Dedousis, Lubnaa Abdur Rahman, Lorenzo Brigatο, Ethan Dack, Andreas Christe +6 more
code/data similarity 0.57
Abstract

Accurate segmentation of interstitial lung disease (ILD) patterns is essential for quantitative disease assessment and longitudinal monitoring. However, existing approaches remain limited by relying on dense annotations and producing static predictions that cannot be refined, motivating interactive approaches. While promptable models show promise in interactive segmentation, their adaptation to ILDs remains largely unexplored. To address this gap, we investigate prompt-guided foundation models for ILD refinement and present, to the best of our knowledge, the first adaptation of MedSAM2 for interactive 3D ILD segmentation on thoracic CT. We investigate three fine-tuning strategies and multiple clinically motivated prompts: bounding-boxes (BBox), point, lasso, and scribble. On a dataset spanning seven ILD patterns and healthy lung tissue, full model fine-tuning performed best, improving the average Dice score by 4.7 percentage points over MedSAM2.While BBox prompts achieve the strongest performance, non-native MedSAM2 interactions such as lasso and scribble prompts also prove effective. Finally, we present and evaluate a proof-of-concept end-to-end workflow in which MedSAM2 is initialized from an automatic segmentation prior and subsequently refined using radiologist prompts. Model weights and plug-ins made available at: https://github.com/AIHNlab/ILD-SemiSegTool.

0.21

MRI-to-CT Translation of Spinal Images via Anatomy-Guided Pseudo-Pairing and Adversarial Diffusion

cs.CV cs.AI ·2026-10-27 ·Eduardo Nieto, Ibai Genua, Davide Scorza, Karen López-Linares
similarity 0.57
Abstract

Magnetic Resonance Imaging (MRI) is routinely used to diagnose spinal disorders, but surgical planning often requires Computed Tomography (CT) for better visualization of vertebral bone anatomy. Synthesizing CT from MRI could avoid additional radiation exposure and streamline preoperative assessment. We propose a three-stage framework for spine MRI-to-CT synthesis. First, an anatomy-guided vertebral matching system identifies similar sagittal MRI and CT slices using spine segmentations and aligns them through rigid registration, creating pseudo-paired data from unpaired scans. Second, these pairs train an adversarial diffusion model for MRI-to-CT translation. Third, synthesized slices are assembled into 3D volumes and refined by a network that improves inter-slice continuity and structural coherence. The framework was trained on over 10,000 unpaired sagittal MRI and CT slices and evaluated on 1,911 slices from 83 MRI volumes spanning all spinal regions. Assessment combined distribution-based measures with vertebral segmentation metrics. Compared with diffusion alone, the proposed approach increased binary 3D vertebral Dice from 0.666 to 0.739. Volumetric post-processing reduced visible discontinuities between stacked slices and improved vertebral coherence in axial and coronal views. Combining anatomy-guided pseudo-pairing, adversarial diffusion and 3D refinement improves spine MRI-to-CT synthesis. Vertebral matching primarily enhanced anatomical alignment and fidelity, while volumetric refinement improved 3D consistency. These findings support further development of MRI-derived CT-like visualization for preoperative planning, particularly to preserve fine intensity details while maintaining volumetric coherence.

0.16

InnerLogic-Surg: An Open Surgical Foundation Model via Continual Pretraining

cs.CV cs.AI ·2026-11-05 ·Kun Yuan, Hao Ding, Yiqing Shen, Gasper Podobnik, Benjamin Killeen +3 more
benchmark similarity 0.57
Abstract

Vision foundation models are the backbone of modern surgical image analysis, yet most surgical systems still rely on encoders pretrained on natural images or on specialist models trained from scratch on comparatively small datasets. Pretraining encoders on large amounts of surgery-specific data has the potential to generally enhance the performance of surgical image analysis methods simply by providing stronger backbones. Here we present InnerLogic-Surg, an open family of surgical vision encoders (21M--300M parameters) obtained by continually pretraining a transformer-based image encoder on millions of surgical images curated from 11,965 internet-sourced surgical videos spanning ~2,900 hours and more than fifteen procedure types. Our training recipe inherits DINOv3's pretraining stage to preserve representation ability after surgical adaptation, and additionally applies a learned feature-upsampling module for high-resolution dense prediction at low token cost. Across a benchmark covering workflow, instrument and anatomy recognition, segmentation, detection, and monocular depth, under the same architecture, the largest InnerLogic-Surg model achieves the best linear-probe performance in all 20 surgical tasks. We demonstrate that surgical continual pretraining yields transferable representations that generalize across procedures, anatomical regions, and task types, showing our surgical image encoders as a promising and scalable alternative to the procedure-specific representation learning approaches that have traditionally dominated surgical computer vision.

0.25

LeCor: Learning to Be Corrected by Meta-Learned Test-Time Training for Interactive 3D Lung-Tumour Segmentation

cs.CV cs.LG ·2026-09-08 ·Yi Luo, Yike Guo, Wenxuan Li, Zongwei Zhou, Rui Zhang +1 more
similarity 0.57
Abstract · 18 pages, 4 figures

Delineating lung tumours on computed tomography (CT) takes a considerable share of the time spent on radiotherapy planning, and a contour proposed by a model can be refined interactively by the clinician. Promptable foundation models such as SAM 3 support this workflow by writing each correction into a session memory that conditions the remaining slices, while the model weights stay fixed. On 690 test cases from five public CT cohorts, fine-tuning SAM 3 on lung tumours raises the Dice obtained from a single point prompt from 0.298 to 0.757, and seven rounds of corrections raise it further to 0.765, but under memory conditioning alone the accuracy on slices the annotator has not touched stops improving after six rounds. We therefore treat each correction as a training signal and propose LeCor, which performs test-time training on a small set of case adapters that are reset for every case and meta-learned such that a single gradient step driven by a click improves the slices that were not clicked. On the 133 test cases that span at least eight slices, LeCor raises the Dice reached after seven correction rounds from 0.787 with the fine-tuned model to 0.827, reduces the number of cases that never reach a Dice of 0.80 from 47 to 27, and reaches in three correction rounds the accuracy that the fine-tuned model attains in seven.

0.21