CS Paper Radar

GateSPINE: Gated Cross-View Fusion for Lumbar Spine MRI Report Generation

Hoang Nguyen Van, Cuong Vuong Tuan, Trang Mai Xuan, Bien Tran Van, Nam Tran Van, Thien Van Luong

cs.CV cs.AI ·submitted 2026-09-30 16:31 UTC · v1

Abstract

Automated report generation can ease the burden radiolo gists face when interpreting multi-sequence MRI studies. Unlike CT, MRI examinations comprise multiple sequences and imaging planes, each con tributing complementary diagnostic information. Existing methods en code a study as a single volume and combine multiple acquisitions by fixed rules. Findings visible in only one plane are thus diluted and of ten missed, lowering recall on clinical efficacy metrics, where a missed abnormality is most costly. We propose GateSPINE, a vision-language framework that fuses sagittal T1 and T2 volumes with a training-free operator, encodes the fused sagittal and axial volumes with two parallel 3D encoders, and decodes their combined representation into a report. Its core mechanism is a gated cross view fusion module that predicts, per feature channel and token, how much of each view to admit, so the more informative view dominates at each spatial location. We evaluate GateSPINE on three lumbar MRI datasets, comprising two public bench marks and a private cohort collected from Phenikaa University Hospital, using both natural language generation (NLG) and clinical efficacy (CE) metrics. GateSPINE achieves the highest CE F1 through improved re call on all three datasets; on SPIDER, which lacks an axial sequence, this reflects the sagittal fusion component rather than the gated cross-view mechanism, which is validated on the two cohorts with both imaging planes. GateSPINE also remains competitive on standard NLG metrics.

Closest papers

Nearest neighbours by meaning across the whole index.

ViBMR: A Large-Scale Multi-Sequence Brain MRI Dataset and Comprehensive Evaluation for Vietnamese Radiology Report Generation

cs.CV ·2026-10-21 ·Dai Lam Le, Minh Khoi Nguyen, Son Dinh Nguyen, Amir Reza Jafari, Viet Ha +4 more
published similarity 0.72
Abstract · Accepted at IEEE/CVF Winter Conference on Applications of Computer Vision (WACV 2027)

Automated radiology report generation for multi-sequence brain MRI holds strong promise for alleviating radiologists' workload, yet it remains a demanding problem: brain MRI studies are inherently volumetric, each pulse sequence carries complementary diagnostic information, and annotated data are critically scarce for low-resource clinical languages. Existing brain MRI-report resources are still dominated by English reports, translated clinical text, or datasets adapted from task-specific imaging benchmarks, leaving routine low-resource clinical reporting and heterogeneous multi-sequence MRI protocols insufficiently represented. To bridge this gap, we introduce ViBMR, to the best of our knowledge, the first large-scale multi-sequence brain MRI dataset paired with routine Vietnamese clinical reports, comprising 3,649 patients and 11,875 MRI series across T1, T2, FLAIR, and contrast-enhanced T1 sequences. Building on ViBMR, we establish a comprehensive evaluation setup for brain MRI report generation, covering representative medical vision-language models, multi-sequence inputs, and feature aggregation strategies. The results provide key insights into dataset characteristics and model behavior, while demonstrating the necessity of native low-resource clinical datasets for reliable Vietnamese-origin brain MRI report generation. Our dataset and baseline models will be released for non-commercial research.

0.34

PerFact: Perception-Derived Fact Prompting for 3D Brain MRI Report Generation

cs.CV ·2026-08-18 ·Jianyu Sun, Zhenxuan Zhang, Guang Yang, Peter J. Lally
similarity 0.65
Abstract

Radiology report generation has matured almost entirely on 2D chest radiographs, where the default route to better reports is a larger backbone or a pre-training one on medical data. We revisit that assumption on 3D multi-sequence brain MRI, a volumetric multi-disease regime, and find that the model is not the lever. Zero-shot medical and radiology vision-language models transfer poorly to brain MRI, with chest radiograph specialists failing most conspicuously, and five backbones fine-tuned identically across three model families and an order of magnitude in scale differ only marginally. What determines the quality of the report is the information injected into the prompt. We delegate perception to upstream 3D segmentation and classification, serialize their outputs into a structured fact sentence, and prompt a LoRA-adapted vision-language model with it; we call this \textbf{PerFact}. In a controlled study that fixes the backbone, data split, target reports, and adaptation while varying only the injected grounding, perception-derived facts outperform retrieved prior reports, retrieval becomes redundant once facts are present, and end-to-end predicted facts remain effective without any ground-truth annotation at inference. The residual gap between predicted and oracle facts is explained by the granularity of the facts rather than by the generator. Closed-ended visual question answering comes at no measurable cost to report quality, though the grounding source has little effect on it. On 3D brain MRI, grounding information, not model choice, is the dominant controllable factor in report quality.

0.27

ICGF-CXRMate: Image-Conditioned Clinical Context Compression and Gated Fusion for Chest X-ray Report Generation

cs.CV ·2026-10-22 ·Vu Minh Tran, Thuc Huynh, Son Thanh Luu, Doanh C. Bui
similarity 0.64
Abstract

Auxiliary patient data can improve chest X-ray report generation, but directly concatenating heterogeneous clinical information with visual tokens produces long, variable-length decoder prompts and may expose the model to redundant or image-irrelevant context. We propose ICGF-CXRMate, an image-conditioned clinical context compression and gated fusion framework. Learnable queries are first conditioned on the current chest X-ray representations and then attend to the patient-data sequence, compressing it into a fixed number of clinical context tokens. Gated cross-attention selectively integrates these tokens into the visual stream, while the compressed tokens are retained in the decoder prompt as a direct clinical pathway. Experiments on linked MIMIC-CXR and MIMIC-IV-ED examinations show that ICGF-CXRMate improves report quality while reducing the average prompt length. In Stage~2, it improves RadGraph-F1 from 24.00 to 28.86, CXR-BERT similarity from 56.86 to 62.80, and BLEU-4 from 5.14 to 7.96 compared with CXRMate-ED, while reducing the average prompt length from 373.89 to 288.37 tokens, corresponding to a 22.9\% reduction. After self-critical sequence training, ICGF-CXRMate outperforms CXRMate-ED on six of eight report-quality metrics in Stage~3. Ablation studies confirm the complementary contributions of image-conditioned compression, gated fusion, and direct retention of the compressed clinical tokens.

0.17

Mr3D-VL: A generalist vision language foundation model for Multiparametric 3D Magnetic Resonance Imaging

cs.CV cs.AI ·2026-08-13 ·Zhi Qiao, Xintong Wu, Yichu He, Feng Shi
similarity 0.63
Abstract

Multi-parametric magnetic resonance imaging (mpMRI) is a cornerstone for brain tumor diagnosis and treatment, yet current AI models face critical limitations: their lack of natural language interaction and interpretability impedes spatial information integration and cross-modal reasoning required clinically. Key challenges arise from significant physical meaning differences across modalities, spatial misalignment due to scan intervals, and the need for complex multi-feature interpretation in tasks like glioma grading. While visual-language models (VLMs) show promise in cross-modal understanding, existing methods focus mainly on 2D image modeling, neglecting direct perception of 3D volumetric space. Although 3D VLMs have been proposed for report generation and feature alignment in 3D CT imaging, mpMRI applications demand collaborative inference across multiple imaging modalities-a requirement unmet by current solutions. To address this, we introduce Mr3D-VL, a dedicated visual-language foundation model for multi-parametric 3D MRI. With 4 billion parameters, it employs an unsupervised pre-trained shared 3D encoder and 4D rotational positional embedding for dual modality-spatial integration. Its cross-modal projection layer uses a multi-resolution feature implantation strategy to enhance feature perception across resolutions. Experimental results show significant improvements over existing 4B/7B/30B domain-specific and general-purpose models in text generation tasks, achieving a BERTScore of 0.856 for report generation, with question-answering accuracy at 0.713 and multiple-choice accuracy at 0.912.

0.04

Diagnosis-Conditioned Spatial Gating and Decoder-Level Supervised Contrastive Learning for Radiology Report Generation

cs.CV ·2026-10-03 ·Md Mustafizur Rahman, Mylene C. Q. Farias
similarity 0.63
Abstract · 5 pages. Manuscript submitted to ICASSP 2027

Radiology report generation models can produce fluent text while still containing finding-level inaccuracies. Diagnosis-driven methods improve generation by conditioning on predicted findings, but these predictions do not directly modify the visual patch features provided to the decoder, and global gating applies the same modulation across spatial locations. We introduce a Position-Aware Gate (PAG) that uses predicted finding representations to modulate visual patches spatially without region supervision. We also propose a Decoder-level Supervised Contrastive Loss (DSCL) that structures decoder representations using shared positive findings rather than instance identity. On MIMIC-CXR, PAG+DSCL improves clinical efficacy (CE) F1 from 0.484 to 0.502 over a matched global-gate reference, while PAG and DSCL individually reach 0.491 and 0.495. Without additional fine-tuning, the combined model achieves 0.226 CE F1 on IU X-Ray, compared with 0.211 reported by PromptMRG.

0.27

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.63
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

cs.CV cs.AI ·2026-11-12 ·Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong +2 more
published similarity 0.63
Abstract · 17 pages, 6 figures, 11 tables

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

0.21

Guided Co-Attention with Adaptive Gating for Multimodal Medical Data Fusion

cs.CV cs.LG ·2026-11-07 ·Muntaqim Ahmed Raju, Priyanka Siddappa, Md Shifat Haider Al Amin, Ruizhe Ma, Md Ripon Ahammed
similarity 0.63
Abstract · IEEE BIBM 2026

Multimodal fusion requires not only exchanging information across modalities but also determining which representations should participate in the interaction and how complementary cross-modal views should be combined. We introduce Guided Co-Attention with Adaptive Gating, a fusion framework that integrates token-wise guidance, bidirectional cross-attention, and sample-specific fusion. The proposed method constructs two directional representations: an image-conditioned text representation, obtained by allowing textual tokens to query visual features, and a text-conditioned image representation formed in the reverse direction. Token-wise guidance modulates the representations before cross-attention, while an adaptive gate learns the relative contribution of the two resulting directional representations for each sample. We evaluate the approach using paired chest radiographs and radiology reports as an image-text test bed for binary (normal vs. abnormal) classification. The two cross-attention directions exhibit distinct performance characteristics, demonstrating that reversing the query and source modalities does not produce interchangeable representations. Ablation experiments further show that bidirectional interaction, adaptive gating, and token guidance provide complementary benefits. The proposed model achieves 96.05% accuracy, 96.10% F1-score, 98.37% AUC, 95.60% Sens@95Spec, and 96.51% Spec@95Sens, yielding the highest mean performance across all evaluated metrics. These findings support explicitly modeling interaction direction, token relevance, and sample-dependent integration when constructing multimodal representations.

0.16