CS Paper Radar

PerFact: Perception-Derived Fact Prompting for 3D Brain MRI Report Generation

Jianyu Sun, Zhenxuan Zhang, Guang Yang, Peter J. Lally

cs.CV ·submitted 2026-08-18 15:47 UTC · v1

Abstract

Radiology report generation has matured almost entirely on 2D chest radiographs, where the default route to better reports is a larger backbone or a pre-training one on medical data. We revisit that assumption on 3D multi-sequence brain MRI, a volumetric multi-disease regime, and find that the model is not the lever. Zero-shot medical and radiology vision-language models transfer poorly to brain MRI, with chest radiograph specialists failing most conspicuously, and five backbones fine-tuned identically across three model families and an order of magnitude in scale differ only marginally. What determines the quality of the report is the information injected into the prompt. We delegate perception to upstream 3D segmentation and classification, serialize their outputs into a structured fact sentence, and prompt a LoRA-adapted vision-language model with it; we call this \textbf{PerFact}. In a controlled study that fixes the backbone, data split, target reports, and adaptation while varying only the injected grounding, perception-derived facts outperform retrieved prior reports, retrieval becomes redundant once facts are present, and end-to-end predicted facts remain effective without any ground-truth annotation at inference. The residual gap between predicted and oracle facts is explained by the granularity of the facts rather than by the generator. Closed-ended visual question answering comes at no measurable cost to report quality, though the grounding source has little effect on it. On 3D brain MRI, grounding information, not model choice, is the dominant controllable factor in report quality.

Closest papers

Nearest neighbours by meaning across the whole index.

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

cs.CV ·2026-08-31 ·Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan +5 more
similarity 0.68
Abstract

Accurate 3D abnormality segmentation in chest CT requires dense spatial supervision, but obtaining expert voxel-level labels is costly. Radiology reports, however, are routinely generated during clinical interpretation and contain instance-specific descriptions that can provide additional guidance without new dense annotation. Existing vision-language grounding methods typically require report-derived findings at inference, making localization dependent on paired text and limiting each forward pass to a queried finding. We propose Instance-Guided Report Anchoring (IGRA), a model-agnostic module that preserves the correspondence between each annotated abnormality instance and the report finding that describes it. IGRA pools each instance representation and anchors it to the corresponding finding embedding during training; all text-related components are discarded at inference. We further reformulate free-text grounding on ReXGroundingCT as multi-label volumetric segmentation by merging same-category instances, allowing all abnormality categories to be predicted in one image-only forward pass. IGRA improves Dice by 22.5% over the strongest image-only baseline (30.93 vs. 25.25) and is comparable to VoxTell on the single-finding subset (30.29 vs. 30.43). Applied unchanged to four standard 3D segmentation backbones, IGRA improves Dice and hit rate across all architectures. Zero-shot evaluation on LIDC-IDRI, PleThora, and a private in-house dataset further shows consistent gains over image-only baselines.

0.17

A 3D foundation model unifying CT interpretation and segmentation

cs.CV ·2026-11-04 ·Yulu Xie, Zilong Li, Shen Xu, Yifan Bai, Liuhong Shi +12 more
similarity 0.68
Abstract · 114 pages, including Supplementary Information; 7 main figures and 2 Extended Data figures

Radiologists interpret computed tomography (CT) scans by jointly determining what a finding represents and where it lies in three-dimensional (3D) anatomy. However, CT models have treated CT interpretation and 3D segmentation as separate tasks, leaving textual findings spatially unverifiable and overlooking potential synergy between clinical understanding and spatial perception. Here we present HoloCT, a generalist 3D foundation model unifying CT interpretation and voxel-level segmentation by jointly modelling whole-volume context and fine-grained anatomical detail, providing 3D masks as evidence. We curated HoloDATA, comprising 195,921 CT scans from 73 public datasets and six clinical cohorts, with 6.2 million instruction dialogues and 2.8 million CT-mask pairs. Across 346 tasks spanning segmentation, lesion screening, visual question answering, and report generation on 61 internal and 12 external datasets, HoloCT outperformed specialist and foundation models. In multicentre validation across 11,455 clinical CT scans from five hospitals, HoloCT outperformed competing models in lesion segmentation and report generation by 18.2 and 15.3 points. It also achieved 85.1% mean accuracy in screening thyroid tumours and colon lesions, exceeding all four participating radiologists in a retrospective reader study. Further analyses revealed bidirectional semantic-spatial synergy: language-guided segmentation delineated unseen anatomical structures and lesions as well as diffuse free-text findings, outperforming the leading approach by 22.1 points, whereas prompting the model to generate corresponding 3D masks alongside its textual outputs significantly improved interpretation performance. HoloCT shows that clinical understanding and spatial perception can be learned together within a single foundation model and offers a path towards more accurate and reliable CT analysis.

0.25

Reference-Guided Data Curation for 3D Medical Vision-Language Pretraining

cs.CV ·2026-11-17 ·Faidra Patsatzi, Ashwin Kumar, Chong Wang, Curtis P. Langlotz, Reinhard Heckel +1 more
publishedcode/data similarity 0.67
Abstract · Accepted at WACV 2027. Code: https://github.com/StanfordMIMI/data-curation-3d-medical-vlm

Training 3D vision-language models (VLMs) on large medical imaging datasets collected across institutions is constrained by data quality. Vast, uncurated pools of image-report pairs are characterized by redundancy, class imbalance, and cross-institutional heterogeneity. We address this challenge of data curation for improving 3D VLM pretraining by proposing an offline, training-free, reference-guided data curation recipe. Our approach leverages a small, high-quality reference set to independently extract quality signals for each modality of a large, uncurated pool and merges them through a rank-aggregation step into a single ranking that guides sample selection. We validate this method on datasets comprising 35k 3D abdominal CT volume-report pairs from two institutions and 58k 2D chest X-ray image-report pairs. On 3D CT, using our reference-guided data curation strategy, our curated model matches the zero-shot disease classification performance of a state-of-the-art baseline (Merlin) while using $3.3\times$ less training data and a reference set of 5k samples. On 2D chest X-rays, our method yields a curated model that matches or exceeds the zero-shot disease classification performance of a model trained on the full pool while using up to $10\times$ less training data and a reference set of only 74 samples. Ablations show that the selection is stable under resampling of the reference, that smaller reference sets still outperform random sampling, and that label rebalancing does not improve performance. To support reproducibility, we release our code.

0.50

BrainTRACE: Tracing Longitudinal, Multimodal, and Volumetric Evidence in Brain MRI Clinical Reasoning

cs.CV cs.AI ·2026-10-05 ·Qizhen Lan, Mengchen Fan, Hang Zhang, Jingwei Duan, Moule Lin +3 more
top venuebenchmark similarity 0.66
Abstract · 35 pages. Accepted to NeurIPS 2026

Brain MRI interpretation is a longitudinal clinical reasoning problem: radiologists compare serial studies, integrate information across MRI sequences, localize findings within volumetric anatomy, and translate this evidence into report-grounded assessments. Existing medical VQA and 3D imaging benchmarks capture important parts of this workflow, but often evaluate brain MRI through isolated images, static volumes, or ungrounded report-style answers, thereby obscuring failures in the evidence chain that support clinical validity. We introduce BrainTRACE, a report-grounded benchmark for evaluating whether vision-language models can trace the evidence structure required for longitudinal brain MRI interpretation. BrainTRACE contains 7,273 scored VQA instances derived from 1,778 longitudinal patients, 7,299 MRI studies, and approximately 29k co-registered 3D MRI sequence volumes. The benchmark is organized by five levels of clinical reasoning, from acquisition recognition to case-level synthesis, and by evidence demands covering longitudinal comparison, report-grounded references, multi-sequence integration, and volumetric spatial evidence. BrainTRACE supports rendered inputs compatible with standard VLM interfaces, a 3D-evidence condition, and a decomposed case-reasoning track that audits six steps in a longitudinal evidence chain. Evaluation of 20 VLM configurations shows that current systems can identify isolated visual cues but rarely compose them into grounded longitudinal interpretations. We release the benchmark specification, evaluation lists, scoring implementation, scoring rubrics, and audit-record format to support reproducible progress in brain MRI VLM evaluation.

0.47

ReVision3D: Attribution-Guided Recursive Self-Improvement for 3D Medical Perception

cs.CV ·2026-09-26 ·Ho Hin Lee, Yuyin Zhou, Yannan Yu, Shi Gu, Yifan Wu
code/data similarity 0.66
Abstract · 28 pages

Recursive self-improvement (RSI) offers a promising path for overcoming the limited visual capability of current medical imaging agents. Yet applying RSI to volumetric imaging remains difficult: failures can arise from acquisition, perception, training recipe, or downstream inference, while self-generated feedback and logged trajectories provide little guidance on which component should change. We introduce ReVision3D, an RSI system that leverages 3D volumes with spatially grounded annotations to determine where visual evidence is lost and recursively improve the corresponding visual capability. A frozen language-model designer proposes revisions to acquisition, perception, training, or inference, while the verifier and system-level objective remain fixed. Our key insight is that an annotated volume forms an exact replay world for view rendering and spatial verification: unvisited views can be rendered on demand, and localized predictions can be checked directly against reference masks. This grounded feedback directs targeted revision, while only changes that improve beyond measured seed noise are retained. Each accepted change triggers renewed attribution, allowing the dominant bottleneck to shift across rounds. On abdominal CT, attribution identifies perception as the dominant remaining limitation. Revising that level enables ReVision3D to achieve 79% liver recall and 83% kidney recall at under 0.4 false positives per patient, outperforming the evaluated frozen multimodal foundation models, with the largest gains on small lesions. Our framework is public available with interactive demo in this project page: \url{https://leeh43.github.io/ReVision3D/}

0.60

SeVeR: Selective Visual Exposure and Retrieval for 3D Medical Image Question Answering

cs.CV ·2026-08-26 ·Yaojun Hu, Danyang Tu, Yang Liu, Jiajin Zhang, Wei Fang +6 more
top venuebenchmark similarity 0.66
Abstract

Volumetric medical VQA requires reasoning over long and redundant 3D visual token sequences, especially in multi-sequence MRI where complementary modalities provide diverse diagnostic cues but expose the decoder to many repeated anatomical regions. To investigate reasoning under multi-sequence visual redundancy, we first introduce BreMRIs-VQA, a clinically curated breast MRI benchmark with 1.19M QA pairs from 71.0K sequences and 12.9K patients, covering both free-text and multiple-choice questions. We further propose SeVeR, a selective visual exposure framework that compresses dense volumes into modality-wise prototypes and retrieves complementary multi-level evidence with change-aware gated attention during decoding, trained with a marginal-utility self-consistency objective that suppresses unhelpful retrieval. Experiments on BreMRIs-VQA and public benchmarks show that SeVeR improves both discriminative and generative performance while exposing substantially fewer visual tokens.

0.60

VoxForge: A Unified Foundation Model for Dense 3D Features Across MRI, CT and PET

cs.CV cs.LG ·2026-11-19 ·Rushil Anirudh, Jayaraman J. Thiagarajan
similarity 0.66
Abstract · 34 pages (8-page main paper, references, and 23-page supplementary material), 7 figures. Rushil Anirudh and Jayaraman J. Thiagarajan contrib…

A unified 3D medical foundation model promises reusable, frozen features that serve a wide variety of tasks such as segmentation, classification and registration on MRI, CT and PET as well as specialist models do. Generalist models still need separate backbones for localized and global tasks, specialist models are confined to a single modality, with the concern that spanning modalities under-emphasizes fine anatomy, and both typically rely on end-to-end fine-tuning to be competitive. We present VoxForge, a single encoder that integrates recent advances in 3D architecture, self-distillation and cross-modal curricula to learn transferable features from permissively licensed MRI and CT volumes. We evaluate it strictly frozen, the test a reusable foundation model must pass, against state-of-the-art generalist and specialist models on segmentation, classification and registration across MRI and CT, and on PET, which it never sees. VoxForge has the best or tied-best average rank in every task group, serves localized and global tasks across modalities at the level of state-of-the-art specialists, and is extremely label-efficient, matching top-performing models on TotalSegmentator CT with a tenth of the labels.

0.17

GateSPINE: Gated Cross-View Fusion for Lumbar Spine MRI Report Generation

cs.CV cs.AI ·2026-09-30 ·Hoang Nguyen Van, Cuong Vuong Tuan, Trang Mai Xuan, Bien Tran Van, Nam Tran Van +1 more
similarity 0.65
Abstract

Automated report generation can ease the burden radiolo gists face when interpreting multi-sequence MRI studies. Unlike CT, MRI examinations comprise multiple sequences and imaging planes, each con tributing complementary diagnostic information. Existing methods en code a study as a single volume and combine multiple acquisitions by fixed rules. Findings visible in only one plane are thus diluted and of ten missed, lowering recall on clinical efficacy metrics, where a missed abnormality is most costly. We propose GateSPINE, a vision-language framework that fuses sagittal T1 and T2 volumes with a training-free operator, encodes the fused sagittal and axial volumes with two parallel 3D encoders, and decodes their combined representation into a report. Its core mechanism is a gated cross view fusion module that predicts, per feature channel and token, how much of each view to admit, so the more informative view dominates at each spatial location. We evaluate GateSPINE on three lumbar MRI datasets, comprising two public bench marks and a private cohort collected from Phenikaa University Hospital, using both natural language generation (NLG) and clinical efficacy (CE) metrics. GateSPINE achieves the highest CE F1 through improved re call on all three datasets; on SPIDER, which lacks an axial sequence, this reflects the sagittal fusion component rather than the gated cross-view mechanism, which is validated on the two cohorts with both imaging planes. GateSPINE also remains competitive on standard NLG metrics.

0.22