CS Paper Radar

Daily listing

2026-09-20 · eess.IV

10 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 1

WILSON - Multi-magnification composites as a foundation for patient-level pathology analysis and diagnostic text generation

cs.AI q-bio.QMcs.CVcs.LG+1 ·2026-09-20 ·Saghir Alfasly, Wataru Uegami, Sobhan Hemati, Wenchao Han, Xiaojia Tang +15 more
Abstract · 61 pages, 6 main figures, with 11 additional figures and 29 tables in the appendices

Pathologists examine tissue sections across multiple magnifications and slides, integrating morphological information to establish a diagnosis. In contrast, most pathology foundation models encode thousands of image patches from a single representative ("best") slide and aggregate their features, limiting multiscale and patient-level contextual integration. Here we introduce WILSON, a vision-language foundation model that represents whole-slide images and multi-slide cases through multi-magnification composites. Trained on approximately 189,000 slides spanning 42 organs and 838 diagnostic entities, WILSON enables patient-level analysis, multimodal retrieval and diagnostic text generation. Without task-specific training, WILSON outperformed a dedicated case-level model (macro-F1, 0.52 versus 0.38) and matched substantially larger slide-level models while requiring 400-1,350 times fewer computational operations. End-to-end fine-tuning improved breast cancer subtyping and stromal lymphocyte grading. WILSON also surpassed PRISM in image-text retrieval (recall@1, 75.6% versus 58.1%) and generated diagnostic descriptions that received higher ratings from five board-certified pathologists than competing models. These findings demonstrate that compact, multiscale representations can support computationally efficient, clinically grounded pathology foundation models.

0.30

Language, Vision & Media 7

Learning-Based 3D Reconstruction of Power Networks from Aerial Point Clouds

eess.IV cs.CVcs.LG ·2026-09-20 ·Rishabh Jain, Anuja Saini, Vishal Jain
published
Abstract · 5 pages, 6 figures. Accepted for oral presentation at IEEE IGARSS 2026

This paper presents an end-to-end framework for reconstructing overhead power utility network topology and extracting span-level physical metadata from large-scale aerial LiDAR. The pipeline begins with semantic segmentation of the input point cloud using an improved KPConv-based model, in which data sampling and loss functions are adapted to emphasize pole and conductor (wire) classes. Network topology inference then proceeds in two stages: (i) pole instances are obtained by clustering pole-class points and validating candidates using geometric criteria, including height and verticality estimated via PCA, and (ii) candidate pole pairs are evaluated using a heuristic method and a lightweight ResNet-based classifier on 2D top-view projections of pole and wire point distributions to determine whether a physical conductor span exists. By explicitly classifying candidate spans, the approach mitigates common failure modes of heuristic connectivity rules in dense or cluttered scenes and under partial wire observation. For each validated wire, attributes regarding utility infrastructure geometry are computed, including endpoint conductor heights, ground elevation, sag-related lowest-point features, conductor arrangement, and wire width. Evaluation on multiple real-world aerial LiDAR datasets demonstrates decimeter-level endpoint height accuracy and approximately 9% relative improvement in recall for topology reconstruction compared to heuristic nearest-neighbor baselines, with larger gains in complex layouts.

0.44

LiteSC: Lightweight Semantic Communication for Robust Wireless Telesurgical Video Transmission

eess.IV ·2026-09-20 ·Zexin Deng, Zhenhui Yuan, Xiang Ji, Yi Han, Gaofeng Li
published
Abstract · Accepted to the 2026 IEEE Conference on Telepresence

Reliable laparoscopic video is essential for telesurgery, yet fixed-rate digital transmission can degrade abruptly under poor channel conditions. We propose LiteSC, a lightweight semantic communication framework combining a frozen pretrained extractor, a compact joint source--channel coding pair, and a receiver-adapted surgical renderer. The extractor produces a latent with approximately 97.9\% fewer scalar values than the red--green--blue (RGB) input, while inference requires neither segmentation masks nor temporal reference frames. Using separate CholecSeg8k source videos for training and testing, we evaluate LiteSC over an additive white Gaussian noise (AWGN) channel at symbol signal-to-noise ratios $E_s/N_0$ from 0 to 25 dB. At a channel bandwidth ratio of $ρ=0.0208$, equivalent to 0.0208 complex channel symbols per RGB source value, peak signal-to-noise ratio (PSNR) rises from 28.7 to 31.9 dB, structural similarity index measure (SSIM) from 0.869 to 0.919, and learned perceptual image patch similarity (LPIPS) falls from 0.102 to 0.048. Against H.265 transmission protected by low-density parity-check (LDPC) coding under the same channel-symbol budget, LiteSC achieves higher SSIM and lower LPIPS, although H.265+LDPC attains a higher peak PSNR. These results show graceful laparoscopic frame reconstruction under the evaluated AWGN conditions.

0.43

Hierarchical Filter Band Selection for Multispectral Object Classification

eess.IV ·2026-09-20 ·Katja Kossira, Jürgen Seiler, André Kaup
published
Abstract · This paper was publsihed at IEEE International Conference on Image Processing (ICIP) 2026, Tampere, Finnland

Multispectral camera arrays capture image data in various spectral bands, enabling image acquisition beyond human perception. These systems are widely used in medical, agricultural, environmental, and remote sensing applications. However, not all recorded bands are needed for classification tasks, thus reducing them can lower hardware complexity and cost. The conditional filter band selection algorithm addresses this by selecting low-noise, non-redundant bands to minimize the number of filters and cameras. This paper improves the approach by introducing a second classification stage that estimates object material in addition to the object label. This information is merged by a decision-tree based band selection strategy. The proposed method achieves a 28.9% relative reduction in classification error on the SMM50 dataset compared to the state-of-the-art. Moreover, for the same classification accuracy, the required number of cameras is reduced from 7 to 4, demonstrating that the proposed approach improves performance while significantly lowering hardware requirements.

0.31

VGG16-MCA UNet: Whole-Tumor Segmentation in 2D FLAIR MRI with Decoder-Side Channel Attention

eess.IV cs.CV ·2026-09-20 ·Shubham Gajjar, Deep Joshi, Avi Poptani, Vishal Barot
benchmarktheorycode/data
Abstract · 22 pages, 7 figures, 4 tables. Code and data splits: https://github.com/ShubhamGajjar/vgg16-mca-unet

Automated brain tumor segmentation supports diagnosis, treatment planning, and monitoring of disease progression, but building models that generalize across heterogeneous tumors and limited annotated data remains difficult. We present VGG16-MCA UNet, a hybrid architecture pairing an ImageNet-pretrained VGG16 encoder with a decoder in which a Multi-Channel Attention (MCA) module recalibrates features after each skip-connection fusion, trained with the Focal Tversky loss to counter severe foreground-background imbalance. We evaluate the model as a 2D, FLAIR-only, whole-tumor segmenter on tumor-positive slices from two public datasets: the BraTS 2020 benchmark and the LGG MRI Segmentation dataset. Using 5-fold cross-validation and a single network formed by averaging the weights of the five fold models, the method attains an aggregate pixel-level Dice (F1) of 95.10% on our held-out BraTS 2020 split and 88.32% on LGG. These scores are computed over all test pixels pooled into a single confusion matrix rather than averaged per case, and are therefore not directly comparable to the per-case mean Dice used in the BraTS challenge protocol. All partitions were drawn over individual slices rather than over patients, so every patient contributes slices to both training and test; the figures above therefore measure interpolation within known patients and should be read as an upper bound rather than as generalization to new ones. The model segments a 256x256 slice in 66.32 ms on a single 6 GB NVIDIA RTX 2060, approximately 8 ms more than an equivalent VGG16-UNet without MCA. We release the split records and report the protocol in full, with the aim of providing a precisely specified and reproducible 2D FLAIR baseline.

0.23

Resolution-Flexible Decoding for Hybrid Neural Video Representations

eess.IV cs.CV ·2026-09-20 ·Taiga Hayami, Masaya Takabe, Hiroshi Watanabe
published
Abstract · Accepted to VCIP 2026

Neural video representations (NVRs) represent videos using neural network parameters and, in hybrid formulations, frame-wise latent embeddings. In conventional hybrid NVRs, the spatial size of frame-wise latent embeddings and the decoder upsampling schedule depend on the target resolution, potentially requiring large and non-uniform upsampling factors. In this paper, we propose a resolution-flexible decoder framework for hybrid NVRs. The decoder is constructed from uniform \(2\times\) upsampling stages, whose target feature sizes are obtained by tracing the spatial resolution backward from the final output resolution. After each upsampling stage, the feature map is aligned with the target size by minimal padding or cropping when necessary. To support this progressive decoding process, we further use intermediate reconstruction supervision and a reconstruction-difficulty-aware frame sampling strategy based on recent frame-wise losses. The framework preserves the basic representation format of hybrid NVRs and can therefore be applied to different backbones. Experiments on the UVG dataset at resolutions of \(1080\times1920\) and \(810\times1440\) show that the proposed approach improves reconstruction quality over the corresponding NVR baselines.

0.20

Does DCGAN-Based Synthetic Augmentation Improve Brain Tumor MRI Classification? An Empirical Study

eess.IV cs.CV ·2026-09-20 ·Irhum Jawad Khan, Talha bin Aslam
Abstract

Generative adversarial networks (GANs) are increasingly used to augment medical imaging datasets, but synthetic images do not necessarily provide downstream classification benefits. This study investigates whether class-specific Deep Convolutional Generative Adversarial Network (DCGAN) augmentation improves brain tumor classification when the classifier and evaluation set are held constant. Experiments were conducted on 7,200 brain magnetic resonance imaging (MRI) scans across four classes: glioma, meningioma, pituitary tumor, and no tumor. For each class, 1,400 real images were used for training and 400 were reserved for testing. A baseline Swin Transformer classifier was trained using only the real training images and compared with a second model trained using the same real images augmented with 500 DCGAN-generated images per class. Both conditions were evaluated on the identical held-out test set. The two models achieved the same overall accuracy of 96%, while macro F1 remained effectively unchanged and ROC-AUC decreased slightly from 0.987 to 0.982 after augmentation. Class-level analysis showed small redistributions in errors rather than a consistent performance gain. FID values between real and synthetic images ranged from 209.15 to 314.27, indicating substantial distributional differences under the adopted evaluation setup. These results suggest that synthetic augmentation should not be assumed to improve medical image classification and should instead be evaluated for both distributional fidelity and downstream task utility.

0.18

ORION-CMR: On-scanner Reporting with Integrated Foundation Model for End-to-End Cardiac MRI Analysis and Interpretation

eess.IV cs.CVcs.LGphysics.med-ph ·2026-09-20 ·Omer Burak Demirel, Kelly K. Horst, Alessio Perazzolo, Elisa Bruno, Kenan Kaya +13 more
Abstract

Cardiovascular magnetic resonance (CMR) provides comprehensive cardiac assessment but remains underutilized because of the complexity of acquisition, post-processing, and interpretation. Existing artificial intelligence (AI) methods address isolated tasks, limiting clinical integration. We present ORION-CMR (On-scanner Reporting with Integrated fOunda-tioN Model), the first clinically evaluated scanner-native end-to-end CMR foundation model. Pretrained on 12,896,733 CMR images from 9,258 studies, ORION-CMR performs sequence classification, ventricular function assessment, late gadolinium enhancement (LGE) detection, binary and multiclass disease classification, and local large language model-based report generation in approximately 90 seconds. The framework. was evaluated on public benchmarks and clinically validated in a multi-vendor cohort of 68 subjects with normal examinations, congenital heart disease, dilated cardiomyopathy, and myocardial infarction. ORION-CMR outperformed supervised baselines and the previously published CMR foundation model (CMR-FM), achieving state-of-the-art performance for LGE classification and scar segmentation. Clinical evaluation achieved an AUC of 0.96 for normal-versus abnormal classification and 0.88 for multiclass disease classification, while generated reports demonstrated 81.4% agreement with expert interpretation. These results demonstrate the feasibility of real-time scanner-native AI-assisted CMR analysis and automated report generation.

0.15

Systems & Networking 2

FINN-Tro: Exploiting Verification Gaps in Dataflow Inference Accelerators

cs.AR eess.IV ·2026-09-20 ·Qazi Arbab Ahmed, Suraj Karki, Thorsten Jungeblut
Abstract

The growing adoption of dataflow accelerators for neural network inference introduces new attack surfaces that existing verification methodologies fail to address. Inference ac- celeration frameworks such as FINN, which transform quantized neural networks into FPGA-deployable dataflow architectures, implicitly assume semantic equivalence between the software model and the synthesized hardware. In this work, we in- troduce the FINN-Tro attack, which identifies and exploits a critical verification gap in the FINN compilation pipeline that enables stealthy hardware Trojan insertion without modifying the original quantized model. The Trojan is placed in the last Matrix-Vector Activation Unit (MVAU) layer and supports two counter-based trigger modes, periodic and persistent, and three payload types: bias addition, logit swapping, and bias subtraction, resulting in six different configurations. FINN-Tro is evaluated on an MNIST feed-forward network and a CIFAR-10 convolutional neural network deployed on a PYNQ-Z1 board. Across the evaluated configurations, accuracy reductions range from 0.90% to 82.84%, while throughput and runtime remain close to the corresponding baseline designs. The most severe configuration, persistent Bias Addition, reduces accuracy from 92.96% to 10.12% on MNIST and from 84.19% to 10.00% on CIFAR-10. The inserted logic introduces modest implementation overhead, with maximum LUT and FF increases of 6.71% and 7.49% for MNIST, and 2.50% and 3.98% for CIFAR-10, respectively. Our findings reveal that widely used pre- and post- compilation verification flows are insufficient for detecting such temporally delayed hardware manipulations, motivating the need for stronger verification mechanisms in accelerator toolchains.

0.31

ShatterQuant: Breaking Uniform Precision with Block-Wise Mixed-Precision on a Systolic Transformer Hardware Accelerator

cs.AR cs.AIeess.IV ·2026-09-20 ·Mikolaj Walczak, Edward Humes, Chao Fang, Marian Verhelst, Tinoosh Mohsenin
published
Abstract

Due to limited support for intra-tensor heterogeneous precision in conventional accelerators, neural network quantization remains largely restricted to per-tensor precision assignment. We present ShatterQuant, a hardware-software co-designed framework enabling mixed-precision quantization within each tensor by assigning independent bit-widths to blocks of a weight projection. ShatterQuant couples precision granularity with PE configuration, such that each precision determines an effective block height. We introduce (1) a hardware-aware post-training method that assigns intra-tensor precision based on block-level standard deviation and weight sensitivity; (2) the ShatterQuant Transformer Accelerator supporting 1/2/4/8-bit weight precision, precision-dependent PE configuration, block rescaling, and integrated softmax and piecewise-linear nonlinearities; and (3) an evaluation of model-hardware tradeoffs using an implementation in the TSMC 16nm PDK operating at 1 GHz, achieving 1.5 TOPS, 760 GOPS/$mm^2$ area efficiency, and 2.8 TOPS/W energy efficiency. On DeiT and ImageNet-1K, ShatterQuant achieves accuracy within $3.3\%$ of state-of-the-art mixed-precision techniques while using a 2 bit lower effective bitwidth, while for PixelDiT demonstrates comparable generation quality. ShatterQuant demonstrates how fine-grained intra-tensor mixed-precision can be realized through hardware-software co-design.

0.30