CS Paper Radar

Daily listing

2026-09-25 · eess.IV

14 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

AI & Machine Learning 1

Learned Compression of SAR Phase-History Data: A Rate-Honest Feasibility Study on GOTCHA

cs.LG eess.IVeess.SP ·2026-09-25 ·Alizishaan Khatri
Abstract

On-board compression of synthetic aperture radar (SAR) phase history is bandwidth-critical, and block-adaptive quantization (BAQ) remains the operational standard. We test whether a small convolutional autoencoder, with its encoder on the sensor, can compete with BAQ on complex phase-history patches from the AFRL GOTCHA collection. Every method is charged for all transmitted bits, rates are reported in bits per complex sample (b/cs), and detection is scored by one-to-one matching of CA-CFAR detections. The autoencoder (28,656 encoder parameters) loses at every rate. At 16 b/cs it reaches -2.87 dB NMSE, against -35.5 dB for 8-bit BAQ with $\pm 3σ$ clipping and -41.0 dB with a tuned clipping range. It also loses to a $16 \times 16$ block Karhunen-Loève transform (KLT), a local linear coder with a tenth of its encoder cost (-5.39 dB). Running the network in a companded Fourier domain helps, but its detection F1 remains bounded at 33%. The evidence points to this model, its normalization, and its objective, not to a fundamental limit of learned coding. Per patch, the data have modest lag-1 coherence ($|ρ| \approx 0.3$) and patch-specific spectral concentration. Two findings concern evaluation itself. First, 97% of CFAR crossings on raw $64 \times 64$ patches are border artifacts of the zero-padded detector. Second, on interior cells BAQ's clipping range decides detection: 8-bit BAQ keeps 69% F1 with tuned clipping but 17% at $\pm 3σ$, and at 8 b/cs or less adaptive FFT thresholding preserves more detections than BAQ. We close with an evaluation protocol for learned radar compression.

0.08

Language, Vision & Media 13

Deep Pseudo-Proximal Map: A Self-Supervised Data-Fitting Agent for Iterative Reconstruction

eess.IV ·2026-09-25 ·Haley Duba-Sullivan, Emma J. Reid, Charles A. Bouman, Gregery T. Buzzard
published
Abstract · To appear in 2026 Asilomar Conference on Signals, Systems, and Computers

Iterative algorithms for inverse imaging problems split reconstruction into alternating subproblems, one of which requires evaluating the data-fitting proximal map. In many practical cases, this proximal map has no analytic solution and so must be approximated by an inner loop solver at every iteration, compounding the cost of the outer reconstruction loop. To address this, we propose the pseudo-proximal map (PPM), a reformulation of the data-fitting proximal map as the minimum mean square error estimate of a synthetic probabilistic model. We implement the deep PPM as a self-supervised neural network trained only on sampled Gaussian noise, requiring no ground-truth training images. The deep PPM can be trained for any operator for which the forward model $A$ and its transpose $A^T$ can be evaluated, with provable equivalence to the proximal map when $A$ is linear. We validate the deep PPM on Gaussian deblurring and 4x super-resolution, where the proximal map has an analytic solution, and on X-ray computed tomography (XCT), where no analytic solution exists. Used as the data-fitting agent within an iterative reconstruction method, the deep PPM reproduces the reference reconstruction to within 1% NRMSE for all three operators, and for XCT, it replaces the inner conjugate-gradient loop with a single network evaluation that is 18x faster.

0.66

MammoClaw: Towards Skill-Evolving Agent Harness for Breast Cancer Mammography Analysis

eess.IV cs.CV ·2026-09-25 ·Krishna Kanth Nakka
published
Abstract · Accepted at Deep Breast Imaging Workshop, MICCAI 2026

In this work, we explore MammoClaw, a training-free agent framework that leverages frozen MLLMs for mammography analysis. To support agentic investigation, we equip the agent with lightweight mammography-specific tools for targeted image analysis, including ROI, paired-view, and contralateral-breast examination. MammoClaw iteratively gathers evidence through these tools, while skill evolution enables non-parametric adaptation by transforming failed trajectories into reusable guidance for later runs. We evaluate the framework on BI-RADS assessment and breast density estimation tasks. In our experiments, we find that tools alone do not reliably improve performance, whereas evolved skills can improve tool-use behavior and performance in some settings. Beyond these results, MammoClaw enables transparent inspection of evidence acquisition, tool interactions, and failure modes, facilitating the analysis and auditing of agent behavior. We view this work as an exploratory study of training-free, self-evolving agentic approaches for mammography and hope it provides a concrete starting point for future work on mammography-specific tools and self-evolution mechanisms. We release our code at https://krishnakanthnakka.github.io/mammoclaw.

0.62

Quantum Diffusion Models for Medical Image Analysis

eess.IV cs.AIcs.CVcs.ET+2 ·2026-09-25 ·Francesco Aldo Venturelli, Stefano Martina, Marco Parigi, Filippo Caruso, Alba Cervera-Lierta +1 more
benchmark
Abstract · 12 pages, 12 supplementary pages, 7 figures, 1 table, 12 supplementary figures

Quantum Machine Learning is a novel field of research aimed at devising machine learning approaches exploiting principles of quantum mechanics, such as superposition, entanglement and interference. In this context, we present a scalable hybrid Quantum Diffusion Model, and evaluate its use for medical image analysis. Specifically, our method is based on a Discrete-Time Quantum Walk algorithm, executed on a real quantum device, to model the forward dynamics of the diffusion model. For the backward step of the diffusion model, we devise and evaluate a classical learning model, which is used to reversely denoise the data. In contrast with other existing attempts at applying quantum machine learning for image analysis tasks, severely limited by the size of existing quantum devices, our method allows to process real-world large size medical data. In particular, we present results on grayscale and RGB images, as well as 3D volumes of moderate sizes. We benchmark our results by reproducing an alternative classical counterpart model, based on diffusion models on discrete state spaces. By doing so, we compare the generation capabilities of both models in terms of three distinct state-of-the-art metrics in the field of image generation, showing the competitive, promising results of our approach.

0.47

Improving Audiovisual Speech Recognition through Synthetic Visual Data Augmentation

eess.AS cs.CLcs.SDeess.IV ·2026-09-25 ·Pol Buitrago, Pol Gàlvez, Javier Hernando
Abstract · 12 pages, 9 Figures

Audiovisual Speech Recognition (AVSR) is a multimodal approach to speech recognition that incorporates visual information from lip movements to enhance model performance. Despite its advantages, its development remains constrained by the limited availability of labeled audiovisual (AV) datasets. This work explores the use of synthetic visual data as a solution, using an audio-driven talking-head pipeline to generate lip-synchronized visual content from existing audio data. We evaluate the effectiveness of synthetic visual data both as an augmentation strategy and as a standalone training resource, applying our approach to Spanish and Catalan. Our results show that augmenting real AV data with synthetic samples yields relative Word Error Rate (WER) reductions of up to 16.2%, demonstrating the potential of this approach. Moreover, we demonstrate that synthetic data alone can serve as a baseline for AVSR training in languages lacking AV datasets. These findings provide evidence that synthetic visual data can serve as a scalable solution to AVSR data scarcity, enabling broader language coverage.

0.45

Airway cross-sectional area measurement using quantitative endoscopy with AI-enabled depth estimation: A proof-of-concept study

eess.IV ·2026-09-25 ·Amirsajjad Taleban, Jake Luo, Christopher E. Larkee, B. Tucker Woodson, Ryan Puccia +2 more
Abstract · 37 pages, 12 figures

Endoscopy is widely used in medicine to visualize anatomical structures for diagnosis and treatment evaluation. However, it does not currently allow rapid, quantitative measurement of airway cross-sectional area (CSA), a key metric for diagnosing and managing respiratory pathologies. There is growing interest in AI-enabled quantitative endoscopy using depth estimation, but a fundamental challenge is the need for ground-truth depth data to train algorithms capable of quantifying depth in physical units (e.g., meters). In this study, 60,000 paired virtual endoscopy images and depth maps were created in Blender from 3D airway models built from computed tomography. A U-Net convolutional neural network was trained to predict the depth maps from the endoscopy images. Point clouds were reconstructed from the AI-generated depth maps using the Equisolid fisheye lens model, and airway perimeters were identified by intersecting a plane with the point cloud to estimate CSA. Nasopharyngeal CSA, a key metric in obstructive sleep apnea, was quantified using this AI-enabled approach with a median error of 5.3 \% relative to the 3D model ground-truth. This pilot study using synthetic data provides strong evidence for the feasibility of developing AI-enabled quantitative endoscopy for airway CSA measurement.

0.35

Beyond Sparsity: Weight Location and Network Context in Pruned MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
Abstract

Pruning reduces the number of weights in magnetic resonance imaging (MRI) reconstruction networks. Equal sparsity, however, can retain weights with different computational roles and different compatibility with the trained network. We study these effects across 120 convolutional U-Net and vision transformer models using controlled edits evaluated before retraining. In U-Net, preserving high-resolution computation improves reconstruction at equal deletion counts across all tested sparsity levels. Equal-operation controls reveal additional sensitivity of the first convolution, which operation count alone cannot explain. In transformers, retained pretrained weight energy correlates with quality within sparsity levels, yet the same masks reverse their reconstruction ranking when the surrounding trained weights change. At 90\% sparsity, matching intermediate output scales largely removes a high-energy-mask penalty while retaining an advantage for the network's original mask. Thus sparsity alone does not characterize reconstruction quality: architecture-specific descriptors are informative, but mask quality can still depend on the surrounding trained network.

0.28

Enhancing Photogrammetric Digital Surface Models with Pretrained Diffusion Models and Multimodal Conditioning

eess.IV cs.CV ·2026-09-25 ·Antoine Lorentz, Stéphane May, Valentine Bellet, Dawa Derksen, Bastien Nespoulous
published
Abstract

Large-scale Digital Surface Models (DSMs) can be produced cost-effectively from satellite images via stereo-photogrammetry. However, the resulting 3D maps are often contaminated by noise, outliers, and voids. On the other hand, aerial LiDAR provides high-accuracy elevation measurements at a substantially higher cost. In this work, we study diffusion models conditioned both on photogrammetric DSMs and Pléiades imagery to refine vertically co-registered DSMs. We introduce a modified Stable Diffusion 3 architecture with a pruned text stream and a patch-wise normalization strategy, enabling stable training on LiDAR data and transfer from natural images to elevation maps. Experiments in French cities demonstrate that multimodal conditioning improves elevation accuracy, reducing Dense Urban RMSE from 6.00 to 3.45 m in the in-context cities and from 4.16 to 2.77 m in the held-out city of Bordeaux.

0.27

ANaLOG: Anisotropic Native-Latent Operator Guidance for Solving Inverse Problems

eess.IV cs.CV ·2026-09-25 ·Darshan Thaker, Lachlan Ewen MacDonald, René Vidal
Abstract

Native-latent guidance is a recent paradigm for solving inverse problems with latent diffusion models. It replaces repeated evaluations of the image-space forward model, each requiring a decoder pass, with efficient guidance computed using a learned latent-space surrogate. However, existing methods apply guidance uniformly across latent dimensions, ignoring that measurements are informative only along certain directions and that the reliability of model predictions varies across inputs and timesteps. We propose ANaLOG, a framework for efficient uncertainty-aware guidance with pretrained latent diffusion models. ANaLOG models uncertainty by learning an anisotropic, input- and time-dependent covariance that is integrated into the guidance mechanism to emphasize reliable directions and downweight uncertain ones. We theoretically analyze this framework in a linear model setting and prove that anisotropic, uncertainty-aware weighting is necessary for correct sampling, whereas isotropic guidance induces sampling errors. Experiments across five challenging inverse problems show that ANaLOG improves perceptual reconstruction quality over existing methods while preserving efficiency.

0.23

Learning Polarization Image Restoration with General Restoration Priors

cs.CV eess.IV ·2026-09-25 ·Chenggong Li, Jinhao Liu, Caiyun Wu, Yidong Luo, Junchao Zhang +1 more
benchmark
Abstract

Polarization imaging captures distinctive surface and geometric cues that benefit a wide range of vision tasks. However, real-world polarization acquisition is often affected by multiple coupled degradations, making image restoration essential for practical polarization vision. Existing methods are largely tailored to specific degradations and remain constrained by the limited scale and quality of polarization data. To address these limitations, we develop an all-in-one polarization restoration framework for diverse and composite degradations. We first study the impact of different polarization representations on restoration performance and identify the normalized Stokes representation as an effective choice for separating intensity and polarization information. Accordingly, we devise a dual-branch architecture that separates intensity and polarization modeling. To overcome the limitations of polarization-specific training, the intensity branch leverages pretrained general restoration priors and a mixture-of-experts extension for composite degradations, while its restoration knowledge is adaptively distilled into the symmetric polarization branch via a cross-domain feature transform. In addition, we establish a composite-degradation polarization benchmark to support all-in-one restoration research. Extensive experiments on public datasets and our proposed benchmark demonstrate the effectiveness of the proposed method.

0.23

Does Vision-Language Pretraining Granularity Matter? A Controlled Evaluation of Vision-Language Objectives Across Chest X-Ray Interpretation Tasks

cs.CV eess.IV ·2026-09-25 ·Denis Musinguzi, Andrew Katumba, Prasenjit Mitra
Abstract

Vision-language pretraining objectives differ in the spatial granularity of their supervision, yet the implications of this distribution for chest X-ray interpretation remain underexplored. We present a controlled study that isolates the pretraining objective: holding the encoder and pretraining data fixed, we train nine objectives spanning global and local contrastive learning, captioning, and their combinations, and evaluate across five chest X-ray tasks of increasing spatial granularity. We find that (i) pretraining granularity aligns with task granularity at the extremes, with local objectives leading on abnormality detection and global objectives on classification; (ii) local objectives are surprisingly competitive on global-level generation and question answering tasks; (iii) the merits of captioning and contrastive learning reverse across granularity levels; and (iv) among combinations, mixing captioning and contrastive supervision is strongest on classification and in distribution generation, while pairing two captioning objectives generalizes best on zero-shot report generation. These results show that no single objective is universally optimal, and that the interaction of objective type, granularity, and task governs downstream performance.

0.19

Awaken, Then Scale: Tiny Adaptation for MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
Abstract

Dormant Awakening (DA) specializes a magnetic resonance imaging (MRI) reconstruction model by fitting a small set of zero weights to one labeled slice. Across fourteen U-shaped convolutional network (U-Net) and vision transformer (ViT) sources, fitting 1,004 or 10,560 weights gives mean peak signal-to-noise ratio (PSNR) gains of .430 and .509 dB. We analyze how scaling the fitted output correction changes evaluation PSNR, then use the calibration correction size to cap changes on new images. The cap bounds changes in root mean squared error (RMSE) relative to the source without an evaluation reference. At 10\% adaptation budget, we compare fixed halving and dynamic capping for DA, unrestricted sparse adaptation and low-rank adaptation (LoRA). The controls increase both measured calibration-evaluation correlations across all six tested architecture-adapter settings. Experiments concern one constructed fastMRI-to-M4Raw shift with fixed source checkpoints and participant panels.

0.19

Image Reconstruction from Phase with Untrained Neural Priors

eess.IV cs.CV ·2026-09-25 ·Ene Meco, Ahmet Enis Cetin
Abstract

Fourier phase encodes important spatial image structure, but recovering an image without measured spectral magnitude requires additional constraints and leaves absolute intensity ambiguous. We propose a projection-based two-stage framework that combines Fourier-phase and spatial-support constraints with an image-specific neural prior. The first stage alternates constraint enforcement with regularized neural-prior updates, while the second performs phase/support refinement alone with guaranteed convergence. We evaluate two neural-prior implementations on the same 77 microscopy images and compare them with a constraint-only baseline. After 500 final refinement passes, the best-performing variant achieves 31.41 dB pooled PSNR, 35.75 dB mean PSNR, and 0.9531 mean SSIM, improving pooled PSNR by 1.51~dB and reducing pooled MSE by 29.3% relative to the baseline. The results demonstrate the benefit of combining neural guidance with explicit constraint refinement at the evaluated iteration budget, while showing that lower phase residual alone does not guarantee greater reconstruction accuracy.

0.16

Towards Whole-Study Screening for Congenital Heart Disease in Fetal Ultrasound Using Multiple Instance Learning

eess.IV cs.CV ·2026-09-25 ·Mohamed Azzam, Ruobing Liu, Esther C. Ugwueke, Ziyang Xu, Shibiao Wan +6 more
Abstract

Congenital heart disease (CHD) is the most common birth defect, yet a large fraction of cases remain undetected on prenatal ultrasound, in part because current artificial-intelligence methods assume that the key diagnostic frames have already been isolated from a study, by a clinician or by a view classifier. We remove that assumption and address CHD screening directly at the level of the whole ultrasound study. We propose a two-stage framework that first learns transferable frame representations by self-supervised masked-autoencoder pre-training on unlabeled fetal ultrasound, then identifies cardiac frames with a disease-robust module and aggregates them with a transformer-based multiple instance learning (MIL) model that produces a case-level diagnosis from study-level labels alone. The model further returns its highest-scoring frames for clinician review, and a hierarchical head separates critical from non-critical CHD. On the internal test set of our multi-source development cohort (FUSE), the proposed cardiac-gated MIL model reaches an area under the curve (AUC) of 0.985 with a specificity of 0.990, outperforming the reproduced NATMED ensemble (AUC 0.861, specificity 0.600) and the FetalCLIP foundation model (AUC 0.867, specificity 0.710). On an independent external cohort, all models initially perform near chance, but label-free CORAL adaptation raises the proposed model from an AUC of 0.513 to 0.944, whereas whole-study and view-dependent baselines do not recover. These results indicate that whole-study MIL with disease-robust cardiac-frame identification is an accurate and deployable route to prenatal CHD screening.

0.15