CS Paper Radar

Daily listing

2026-10-04 · eess.IV

2 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 2

TIRMamba: A Thermal-Prior-Modulated State-Space Network for Sub-Million-Parameter Infrared Image Super-Resolution

eess.IV cs.CVcs.LG ·2026-10-04 ·Chun-An Lin, Tsung-Jung Liu, Yen-Chieh Ouyang
benchmarkcode/data
Abstract · 13 pages, 4 figures, 5 tables. Submitted to IEEE Transactions on Geoscience and Remote Sensing. Code and trained models will be released at …

Infrared image super-resolution is currently led by Mamba-based networks with 26 to 37 million parameters, which are difficult to deploy on the airborne and handheld platforms where thermal imaging is most needed. This paper presents TIRMamba, a network with 896K to 910K parameters for single-channel thermal imagery. A Thermal Prior Highway computes gradient, local-contrast and spectral cues once at the input and, through one adapter per residual group, modulates a weight-tied bidirectional state-space trunk and gates its dual-scale detail branch; a tri-path reconstruction adds the learned residual to a bicubic radiometric baseline. Because the standard benchmark provides only 265 infrared training images and evaluates fusion products on full images, we train with a replay strategy: grayscale DIV2K pre-training followed by fine-tuning on 64-pixel patches drawn with equal probability from the infrared and natural corpora. At scale factor 4, TIRMamba matches the strongest protocol-trained methods on both official test sets with 29 to 40 times fewer parameters and 2.8 to 9.4 times lower latency; at scale factor 2 it gives the highest SSIM on both. A variant with prior-conditioned selectivity, TIRMamba-Rad, corrects a 3 dB raw-thermal failure of an intermediate size-invariant design and gives the best results at scale factor 4 on raw-thermal, unmanned-aerial-vehicle and independent-sensor test sets. Code and trained models will be released at https://github.com/julian135707/TIRMamba upon acceptance.

0.56

Distortion-Free High-Resolution PROPELLER-DWI: Technical Advances and Initial Demonstration for the Prostate

eess.IV ·2026-10-04 ·Jingjia Chen, Kun Zhou, Haoyang Pei, Angela Tong, Sherif Elsherif +5 more
Abstract · 37 pages, 10 figures

Purpose: To develop and evaluate an integrated acquisition and reconstruction framework for distortion-free, high-resolution prostate diffusion-weighted imaging (DWI). Methods: PROPELLER-DWI combines pulsed-gradient spin-echo diffusion preparation, an interleaved gradient-and-spin-echo PROPELLER acquisition with golden-angle blade rotation, and self-supervised joint reconstruction and denoising. It was compared with conventional NUFFT reconstruction and MPPCA denoising in a NIST/QIBA diffusion phantom, 25 volunteers, and 4 clinical patients undergoing 3T prostate MRI across three spatial-resolution settings and two b-values (50 and 1000 s/mm2). Reader studies compared geometric fidelity, image quality, and overall preference with clinical single-shot EPI-DWI. Results: PROPELLER-DWI preserved prostate geometry in cases where EPI-DWI showed susceptibility-induced distortion, signal loss, and metal-related artifacts. Self-supervised reconstruction improved noise suppression, with the greatest benefit at higher spatial resolution. Across all resolutions, PROPELLER-DWI had significantly higher geometric fidelity than EPI-DWI, and radiologist preference increased with the severity of EPI distortion. ADC measurements remained consistent across resolutions and comparable to clinical EPI-DWI, whereas EPI-DWI ADC varied with increasing resolution. Retrospective reduced-shot reconstruction also supported shorter scan times. Conclusion: PROPELLER-DWI enables distortion-free, high-resolution prostate DWI while preserving quantitative diffusion measurements, providing a practical alternative for technically challenging prostate MRI and applications requiring improved geometric fidelity.

0.24