CS Paper Radar

Daily listing

2026-10-26 · eess.IV

6 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 6

Neural fields for adaptive white matter microstructural modeling

eess.IV ·2026-10-26 ·Adam M. Saunders, Gaurav Rudravaram, Elyssa M. McMaster, Michael E. Kim, Trent Schwartz +4 more
published
Abstract · 12 pages, 7 figures. Accepted to SPIE Medical Imaging 2027: Image Processing

Diffusion magnetic resonance imaging (MRI) is sensitive to the micron-level diffusion motion of water molecules, allowing in vivo characterization of white matter architecture in the brain. Microstructural models like diffusion tensors or the Standard Model are typically fit independently on each voxel, limiting their ability to incorporate local spatial context and adapt to regional tissue complexity. Here, we introduce FiberField, an approach using neural fields that selects from multiple candidate models with different numbers of fibers to estimate fiber configurations and properties. This method incorporates spatial context through coordinate representations and model-weighted priors inspired by Bayesian model averaging to adapt to local microstructure. To compare FiberField with ground truth fiber properties, we validate on simulated diffusion MRI before applying to in vivo data. In simulated diffusion MRI, FiberField accurately estimates fiber directions and diffusivities using a multi-stick model (angular error: $2.2 \pm 2.8°$, diffusivity root mean square error (RMSE): $4.4 \times 10^{-4} \pm 5.2 \times 10^{-4}$ mm$^{2}$/s, fiber sensitivity: $0.87 \pm 0.21$). FiberField resolves fibers at 25% smaller angular separations than fod2fixel, and the diffusivity RMSE is 52% lower within fiber crossings than the Standard Model. On acquired diffusion MRI, FiberField's estimated fiber directions agree with those from MRtrix3's fod2fixel while also mapping microstructural properties such as diffusivity (angular difference: $10.5 \pm 7.1°$). Using neural fields allows for adaptive white matter modeling for selecting from a set of alternative models while maintaining accurate fiber property estimation.

0.36

Accuracy and efficiency of compact foundation models for surface-water mapping during floods

eess.IV cs.CVcs.LGstat.AP ·2026-10-26 ·Parastoo Farajpoor, Mohammadreza Narimani
code/data
Abstract · 19 pages, 8 figures, 7 tables. Code: https://github.com/MohammadrezaNarimaniUCDavis/Prithvi_Tiny_Floodwater_GeoAI Data: https://doi.org/10.5…

Pretrained Earth observation models may reduce the effort needed to map surface water, but their value depends on the alternative against which they are compared. We evaluated Prithvi-EO-2.0-Tiny using the 446 hand-labeled Sentinel-2 chips from 11 flood events in Sen1Floods11. A fine-tuned model, a frozen-encoder model, and an identical randomly initialized architecture were compared with a similarly sized U-Net, a larger Prithvi model, and spectral-index thresholds. Experiments varied the number of training chips, excluded events from model fitting, and measured computational cost and prediction reliability. With 252 training chips, U-Net achieved a water intersection-over-union (IoU) of 0.856 on the official test set, compared with 0.833 for fine-tuned Prithvi-Tiny. Pretraining improved the tiny transformer over random initialization by a reported 0.046 IoU with 25 training chips and 0.023 with 252 chips, but did not reverse the U-Net ranking. Across 11 event-exclusion evaluations, mean IoU was 0.768 for fine-tuned Prithvi-Tiny and 0.777 for U-Net; the paired interval included zero. Fine-tuned Prithvi-Tiny processed a 512x512-pixel chip in 16.1 ms on a GPU and 258 ms on a laptop CPU, compared with 30.6 and 665 ms for U-Net. Errors were concentrated near water boundaries, and high predictive entropy identified many, but not all, erroneous pixels. These results support a specific role for compact pretrained models: lower measured computational demand with competitive accuracy, rather than consistent superiority. Event-dependent performance, shared hyperparameter selection, and the distinction between observed water and newly inundated land delimit the conclusions.

0.36

Towards Myocardial Infarction Diagnosis: An Investigation into Machine Learning and Deep Learning Algorithms using ECG Data

eess.IV cs.CVcs.LG ·2026-10-26 ·Rafid Ahnaf, Husne Mubarak, Fahim Ahsan, G. M. Refatul Islam, Rafeed Rahman +1 more
Abstract · 18 pages, 7 figures, 3 tables. Based on the authors' undergraduate thesis at BRAC University (2023)

Myocardial Infarction (MI) is a severe and potentially fatal cardiac condition caused by myocardial injury due to ischemia, and timely detection can substantially reduce its mortality. Electrocardiography (ECG) is the primary diagnostic modality for MI, but manual interpretation is susceptible to human error. In this work, we propose Visionary V2, a multi-step, adaptive filtration method for ECG signal normalization, and use it to study machine learning (ML) and deep learning (DL) approaches to MI detection on the PTB Diagnostic ECG Database using all 15 available leads. On statistical features extracted from the filtered signals, such as the R-R interval, a Bagging ensemble of decision trees reaches 96.6% accuracy, compared with 87.7% when the signals are processed with BioSPPy. We further generate an image dataset from the filtered signals, on which a custom ResNet-50 misclassifies only 1 of 7,000 validation images and a custom CNN reaches an F1 score of about 98.7%. Finally, we apply LIME, Grad-CAM and Integrated Gradients to verify that the image models attend to the ECG waveform rather than the background. These results indicate that careful signal normalization combined with ML and DL models can support fast and accurate automated MI screening.

0.28

Decoding Motion-Blurred QR Codes: Motion-Parameter Error Tolerance and Model-Based Recovery

eess.IV ·2026-10-26 ·Zhi Zeng, Qiaochen Su, Si Xiong, Yaoqi Wang, Yufei Cai +2 more
benchmark
Abstract · 13 pages, 5 figures, and 13-page supplementary material

Quick Response (QR) code deblurring must ultimately recover the encoded payload, yet how accurately the underlying camera motion must be estimated remains an open question. To address this question, we formulate motion-blurred QR recovery within a unified mathematical framework of identifiability and systematically measure the decoding tolerance to perturbations in motion length, direction, rotation or scaling centre, and speed profile. These controlled experiments reveal three structural laws: 1) parameter tolerances shrink rapidly as blur amplitude grows and are tightest under uniform speed, whereas accelerating motion is substantially more forgiving; 2) length tolerance can differ markedly between underestimation and overestimation; 3) errors that are individually benign interact strongly and prevent decoding when combined. Guided by these findings, we propose a grey-box recovery pipeline in which two compact networks predict an initial corner trajectory, followed by tolerance-guided candidate search, alternating image-and-path fitting, and regularised linear inversion. On a new benchmark of 955 handheld motion-blurred photographs captured across four phone models and four motion categories, our method recovers the exact payload on 93.1% of the images, outperforming the strongest fine-tuned deblurring network at 83.6% and reducing the decoding error rate by 58.0%.

0.28

MedVTok: A General-Purpose Medical Visual Tokenizer

eess.IV cs.CV ·2026-10-26 ·Chenglong Ma, Yuanfeng Ji, Junzhi Ning, Jiyao Liu, Yujie Wei +16 more
published
Abstract · NeurIPS 2026

Multimodal medical AI requires a common visual interface for encoding heterogeneous imaging evidence for patient condition modeling. However, existing medical visual tokenizers are often tied to a specific dimension and imaging modality, forcing multimodal systems to rely on fragmented and poorly reusable representations. We introduce MedVTok, a general-purpose visual tokenizer that maps 2D images and 3D volumes from diverse imaging modalities into a unified token space. Building such a tokenizer poses two key challenges: preserving anatomical structure across dimensions and capturing clinical semantics across modalities. To this end, MedVTok introduces (i) slice differential regularization, which explicitly models inter-slice anatomical coherence missing in previous per-pixel/per-voxel supervision, and (ii) multi-expert representation alignment, which integrates knowledge from multiple medical expert encoders while retaining modality-specific complementary knowledge. Trained on 28M images and 70K volumes across 9 imaging modalities, MedVTok supports classification, retrieval, segmentation, synthesis, visual question answering, and medical report generation through a single tokenizer. Across 24 benchmarks, MedVTok achieves state-of-the-art performance, demonstrating a scalable token interface that unifies medical image dimension, modality, and task usage.

0.19

When Slides Met Scans: Cross-Attention for Renal Cancer Prognosis

eess.IV cs.CV ·2026-10-26 ·Anusha Krishnamoorthy, Basudha Pal
Abstract

Histopathology and computed tomography (CT) provide complementary views of renal cancer. We connect these modalities through bidirectional cross-attention between 16 histology prototypes and up to 32 kidney-centered CT tokens from frozen foundation models. In 210 TCGA-KIRC patients with 46 disease-specific survival (DSS) events, 5-fold evaluation yielded a C-index of $0.760\pm0.081$ and 3-year AUROC of 0.773 (95\% CI 0.678--0.860), the highest averages among evaluated unimodal and fusion baselines. External testing in 180 CPTAC-CCRCC patients yielded DSS C-index of 0.629 with CT withheld. Attribution analysis linked predictions to image regions while exposing acquisition artifacts. These findings support further study of cross-scale fusion and independent multimodal validation.

0.13