CS Paper Radar

Daily listing

2026-10-27 · eess.IV

11 papers first submitted this day (UTC) in eess.IV — Image and Video Processing. arXiv announces a day's submissions the next evening, so the newest day fills up over ~24 h.

Score = weighted mean ofCitations 20%Upvotes 10%Code stars 10%Venue 15%Code/data 10%Novelty 15%Momentum 15%Substance 5%how it works

Language, Vision & Media 10

Flow Matching for Fluctuation-Based Fluorescence Super-Resolution

eess.IV math.OC ·2026-10-27 ·Alberto Cozzani, Giacomo Meanti, Laure Blanc-Féraud, Luca Calatroni
code/dataunusual
Abstract · 5 pages, 3 figures, submitted to ISBI 2027. Code available at https://github.com/cozzalberto/flow_fluo

Fluctuation-based super-resolution techniques are an appealing alternative to single-molecule and structured-illumination microscopy, as they adapt to standard acquisition settings and exploit the independent stochastic fluctuations of fluorophores across a sequence of frames. However, most existing approaches lack an explicit model of the acquisition process and provide only relative intensity estimates, limiting quantitative analyses. In this work, we combine model-based and generative approaches to exploit the full stochastic information in the sequence, proposing a reconstruction framework built on flow matching and a double-Poisson forward model accounting for blinking, blur, under-sampling and noise. The method alternates two steps: a flow matching model first learns the distribution of the acquired data; then, the sample and the background are jointly estimated by minimising a Kullback-Leibler divergence between observed and simulated distributions via regularised proximal gradient steps. On simulated and real Argolight data, the method resolves lines separated by 120 nm, outperforming SACD and eSRRF.

0.41

Looping Kooshball: Improved k-space coverage for silent fMRI using 3D coherence trajectories

eess.IV ·2026-10-27 ·David J. Frey, Shreya Ramachandran, Jeffrey A. Fessler, Douglas C. Noll, Tobias C. Wood
Abstract · 11 pages, 5 figures

Functional MRI (fMRI) is widely used to characterize brain activity and connectivity, but conventional gradient-echo echo-planar imaging produces high acoustic sound-pressure levels by operating gradient hardware near its limits. Scanner noise can increase anxiety and motion, particularly in noise-sensitive populations, and can evoke auditory responses that confound both task-based and resting-state measurements. Looping Star (LS) is a near-silent, T2*-weighted acquisition that uses slowly varying gradients and multiplexed, temporally staggered coherences. Conventional LS rotates planar encoding trajectories across shots to achieve three-dimensional coverage. Because these planes intersect near the center of k-space, sampling is dense at low spatial frequencies but sparse and nonuniform at the periphery, limiting efficiency when relatively few shots are combined for high temporal resolution. We introduce Looping Kooshball (LKB), a complementary LS trajectory that extends through all three spatial dimensions within each shot. LKB is designed to improve volumetric k-space coverage while preserving the echo-formation and coherence-crushing properties of LS. We compare LKB with conventional LS using point-spread-function analysis, in-bore acoustic measurements, structural phantom imaging, and preliminary visual-motor fMRI experiments. We evaluate whether LKB reduces undersampling artifacts and improves temporal stability and functional-activation detection without sacrificing the near-silent operation of LS.

0.33

Image Modeling: From Handcrafted Priors to Foundation Image Models

eess.IV cs.CV ·2026-10-27 ·A. Murat Tekalp
Abstract

This paper unifies six decades of image modeling, evolving from handcrafted mathematical tractable priors to solve inverse problems in imaging to data-driven deep foundation image models for both image generation and solving inverse problems, under a common Bayesian framework that formulates image modeling as an implicit or explicit probabilistic characterization of a data manifold. Every image restoration or generative task fundamentally seeks to answer the same question: What makes an image look like a real image? In the Bayesian framework, this question is encapsulated by the prior probability density p(x), or its more optimization-friendly counterpart, the log-prior log p(x). While early works in solving inverse problems, such as Tikhonov, Total Variation (TV), and Non-local priors relied on explicit handcrafted definitions of log prior to model local smoothness, modern techniques, such as Plug-and-Play (PnP) priors and Denoising Diffusion models, are rooted in algorithmic uncoupling and implicit manifold learning that apply to both inverse problems and conditional image generation. By grounding imaging inverse problems and conditional image generation under a single mathematical engine: the gradient of the log-prior, or the Stein Score Function, we bridge the gap between signal processing and machine learning communities, turning what seems like parallel developments into a single, evolution of image modeling from handcrafted analytical models to models learned from big data, demonstrating that the pursuit of the denoising score is the common thread connecting variational optimization (in MAP estimation) to posterior sampling (in modern foundation image models).

0.32

Medical Image Analysis with Machine Learning (MEDiml): Strategies for Simpler Radiomics

eess.IV physics.med-ph ·2026-10-27 ·Mahdi Ait Lhaj Loutfi, Simon Provost, Élodie Gillard, Moustafa Amine Bezzahi, Alexander Chum +11 more
code/data
Abstract · 11 pages, 3 figures, 2 tables. Software paper. Full reference manual: arXiv:2610.29666 . Software, documentation, tutorials, and resources a…

Radiomics extracts quantitative features describing tumor shape, intensity, and texture from medical images to build models that predict clinical outcomes. However, large feature sets increase the risk of overfitting in small datasets, and building an end-to-end workflow often requires programming expertise. We present MEDiml (Medical Image Analysis with Machine Learning), open-source radiomics software available as a Python package (MEDiml-pkg) and a no-code desktop application (MEDiml-app). Both run on the same computational engine, and code generation exports graphically configured workflows as executable Python code. Feature extraction follows the Image Biomarker Standardization Initiative (IBSI) standards. MEDiml is built around complexity minimization: features are grouped into levels of increasing complexity (morphological, intensity, textural,l and filter-based), a model is trained at each level, and the simplest level not significantly outperformed by more complex ones is retained. Applied to five oncological datasets (2,104 scans), MEDiml achieved AUCs of 0.65 to 0.82, with morphological or intensity features sufficient in four of the five tasks. Resources: www.mediml.app.

0.28

Longitudinal retinal imaging and auxiliary tasks for discrete-time survival prediction of referable diabetic retinopathy and maculopathy: a retrospective cohort study

eess.IV ·2026-10-27 ·Paul Nderitu, Laura Webster, Samantha S. Mann, Christos Bergeles, Timothy L. Jackson
Abstract

Deep learning can predict progression to referable diabetic retinopathy (rDR) and referable maculopathy (rM) from screening photographs, but existing models ignore the prior images that screening programmes hold. We assessed whether multi-visit (MV) images and auxiliary objectives that model the future visit improve prognostic prediction. In this retrospective cohort study of macula-centred photographs from the South-East London Diabetic Eye Screening Programme (UK), eyes without referable disease at baseline and with a follow-up at 20-28 months were split into development (72,559 eyes, 36,648 patients) and test (17,917 eyes, 9,071 patients) sets. A time-aware discrete-time survival model predicted incident rDR (R2 or R3), rM (M1), or either (rDR/rM). We compared baseline-only input with up to three visits (MV), alone or with auxiliary supervision of future-visit age (MV+age) or future-visit latent prediction (MV+latent), using the AUROC of 28-month cumulative risk and paired DeLong tests with Benjamini-Hochberg correction. In the test set, 308 eyes (1.7%) developed rDR/rM, 58 (0.3%) rDR, and 275 (1.5%) rM. MV images increased the AUROC for rDR/rM from 0.749 to 0.786 (+0.037, 95% CI 0.012-0.061; q=0.011) and for rM from 0.749 to 0.788 (+0.039, 0.013-0.065; q=0.010). Auxiliary objectives did not improve MV model performance. In eyes with two or three visits, prior visits accounted for 30-38% of positive Grad-CAM attributions. Prior screening images improved prediction of incident maculopathy and the composite rDR/rM outcome, with gains driven by longitudinal images, not auxiliary supervision. External validation and prospective studies are required before the deployment of models to individualise screening.

0.28

One Rater to Score Them All: Frozen Large Language Model Anchoring for Video Quality of Experience

cs.MM cs.NIeess.IV ·2026-10-27 ·Parsa Hassani Shariat Panahi, Amir H. Jalilvand, M. Hassan Najafi
Abstract · 4 figures, 2 tables

Quality of Experience results for video streaming cannot be compared across studies, because public databases share neither test material nor subjects. This work introduces a common reference rater: an open-weights large language models with a fixed rubric and greedy decoding that scores the delivery events of every session and supplies the shared items that score equating requires. The rater is used without training, and it reads only the playback event log of startup delay, stalls and quality switches, which most delivery databases retain even when they share nothing else. A monotonic curve then maps each study's native scale onto the common scale. On 3{,}552 sessions from four studies covering four rating scales, the rater attains a Spearman correlation of 0.809 on VL04 of the ITU-T P.1203 collection, exceeding P.1203 mode~0 on the same sessions, with a Krippendorff alpha of 0.974 over repeated scoring and 0.951 across three serving providers. Sessions from three further laboratories give correlations from 0.756 to 0.787. After calibration, the four studies are placed on a single 0 to 100 scale with a held-out error between 7.8 and 13.3 points, and a mean VMAF of 60 corresponds to positions 17 points apart in two of the studies.

0.26

EUReCA: End-to-End Unified CBCT Reconstruction Across Clinical Acquisitions

eess.IV cs.AI ·2026-10-27 ·Jiening Zhu, Chengzhu Zhang, Jason Fan, LiCheng Kuo, Weixing Cai +6 more
Abstract

Cone-beam computed tomography (CBCT) is widely used for image-guided radiotherapy, but reducing the number of projections to lower dose and scan time makes reconstruction increasingly ill-posed. We present EUReCA (End-to-end Unified REconstruction across Clinical Acquisitions), a geometry-aware feed-forward model for variable-view clinical linac CBCT. For a given acquisition trajectory, EUReCA accepts 8-100 projections with a single set of weights, without view-count-specific retraining; the same architecture and training recipe extend unchanged to other clinical trajectories. It combines learned projection features with an in-frame Feldkamp-Davis-Kress (FDK) reconstruction. The model encodes each projection with a shared multiscale backbone, back-projects features into multiresolution 3D grids using the acquisition geometry, aggregates variable numbers of views at fixed computational cost, and refines the volume with a global 3D transformer and multilevel decoder. On simulated data, EUReCA achieved 29.9-33.2 dB PSNR with 10-100 views and outperformed all applicable feed-forward baselines; it also exceeded iterative optimization-based methods while running orders of magnitude faster. On 15 measured patient CBCT scans evaluated against vendor reconstructions, EUReCA achieved the best performance at every tested view count. These results suggest that geometry-aware, measurement-anchored feed-forward reconstruction can provide a practical and flexible foundation for variable-view linac CBCT.

0.25

Quantized Edge Inference of a Self-Supervised SAR-Optical Encoder on Commodity x86 Hardware

eess.IV cs.CVcs.LG ·2026-10-27 ·Christian Sanchez-Leon, Dongming Chen
Abstract · 3 pages, 1 figure, 3 tables

Self-supervised vision transformers are increasingly used as reusable encoders for Earth observation, but their inference cost on the hardware available in the field is rarely characterized. We deploy a pretrained SAR-optical masked-autoencoder encoder on three commodity x86 nodes, from a low-power CPU without AVX2 to an AVX2+VNNI reference, at FP32, FP16 and INT8 on the CPU and, where present, the integrated GPU, and report latency, energy (RAPL and wall plug) and linear-probe accuracy. Quantization is accuracy-neutral: INT8 changes micro-mAP by only +0.0006, within the seed spread, so precision becomes a pure cost decision. INT8 lowers CPU latency on every node, by 1.45x even on the CPU without AVX2, and CPU energy wherever it is measured, and the VNNI reference (1.53x) suggests a further gain beyond AVX2. The Pareto-optimal device shifts from the integrated GPU, which is 4.38x faster than the CPU on the weakest node, to the CPU as the CPU class improves.

0.24

Effects of Deep Learning Architecture and Pretraining on Automated Vocal Fold Segmentation in Ex Vivo High-Speed Phonation Images

cs.CV eess.IVphysics.flu-dyn ·2026-10-27 ·Varun Vinayak Kalaiarasan, Charles Farbos de Luzan, Khalid Malik, Ephraim Gutmark, Liran Oren
Abstract · 37 pages, 8 figures, 7 tables

Two-dimensional (2D) intraglottal particle image velocimetry (PIV) of ex vivo phonation experiments quantifies vocal fold medial surface dynamics and the intraglottal flow field. However, it relies on manual segmentation because residual glare, low tissue-to-flow contrast, and tracer-particle speckle obscure the vocal fold boundaries. This study assessed how deep learning architecture and ImageNet pretraining affect automated vocal fold segmentation in these high-speed images. Four established architectures from three categories were benchmarked: the convolutional neural network (CNN)-based UNet and UNet++, the hybrid CNN-transformer-based TransUNet, and the pure transformer-based Swin-UNet, the latter two trained from scratch and from ImageNet-pretrained weights. Using 16,344 expert-annotated images from 227 phonation trials of excised canine larynges, the six pipelines were trained with five seeds under a standardized protocol and compared on 50 held-out test trials using trial-level Wilcoxon signed-rank tests with Holm correction. Mean Dice similarity coefficient (DSC) spanned only 0.9734 to 0.9764, so the pipelines differed mainly in boundary fidelity. Pretraining significantly improved the boundary F1 score (BF1) and 95th percentile Hausdorff distance (HD95) of the TransUNet and Swin-UNet, about four times more for the Swin-UNet. Once pretrained, the two performed similarly, although the Swin-UNet has only about a quarter of the trainable parameters. Without pretraining, the TransUNet had a significantly higher BF1 and a lower HD95 than both CNN-based pipelines and about half their share of images with HD95 > 50 pixels. To our knowledge, this is the first study to apply deep learning to vocal fold segmentation in 2D intraglottal PIV, and it offers a reference framework for segmenting experimental flow-visualization images with noisy optical conditions or highly deformable objects.

0.24

Detector-Integrated Multi-Cue Association for Occlusion-Aware UAV Multi-Object Tracking

cs.CV eess.IV ·2026-10-27 ·Shu-Hung Chou, Trong-An Bui, Wei-Ming Chen, Hsin-Piao Lin
benchmark
Abstract

Multi-object tracking (MOT) in unmanned aerial vehicle (UAV) imagery is challenging because vehicles are small, visually similar, and frequently occluded, which leads to identity switches (IDSW). Appearance-based trackers such as DeepSORT rely on a standalone re-identification (ReID) network, whose per-target inference limits runtime speed, while the appearance of small or occluded vehicles remains unreliable. This paper proposes a detector-integrated multi-cue tracking framework. Lightweight projection heads are attached to the neck of the YOLOv8n detector to extract target embeddings through ROIAlign, producing detections and embeddings in a single forward pass. A multi-cue association cost then combines motion, IoU, and appearance distances with weights determined through ablation, complemented by low-score rescue and appearance-memory protection. On the UAVDT benchmark, the proposed method achieves a MOTA of 28.33, a HOTA of 31.16, and an IDF1 of 38.18 at 82.59 FPS, the best among the compared trackers in all three metrics, and reduces IDSW by 58.4\% compared with DeepSORT.

0.20

Robotics, Control & Signals 1

Assessing BIOMASS Radiometric Stability using Permanent Scatterers

eess.SP eess.IV ·2026-10-27 ·Marco Manzoni, Francesco Salvaterra, Claudio Maria Prati, Stefano Tebaldini
Abstract

Monitoring the relative radiometric stability of the European Space Agency's BIOMASS P-band synthetic aperture radar (SAR) requires separating instrumental and processing effects from temporal changes in the scene backscatter. This study investigates the use of permanent scatterers (PSs) as opportunistic references for estimating residual radiometric gains without dedicated calibration targets. The PS-based calibration (PSCal) framework combines amplitude-based scatterer selection with iterative maximum-likelihood gain estimation. Simulations assess detection and estimation performance under the limited number of acquisitions available in BIOMASS stacks, highlighting the importance of stringent selection thresholds and the dependence of estimation accuracy on scatterer abundance and signal-to-noise ratio. The approach is applied to datasets over Nairobi, Kenya, and Cordoba, Argentina. Over Nairobi, PSCal identifies an approximately 1 dB radiometric anomaly subsequently traced to a defect in radio-frequency interference mitigation, while the remaining acquisitions exhibit estimated gain variations generally within 0.1 dB. Over Cordoba, twelve acquisitions spanning two mission phases separated by approximately eight months yield residual gain variations on the order of 0.1 dB despite pronounced changes in the scene backscatter and acquisition geometry. Results were observed to be consistent with measurements from the BIOMASS Calibration Transponder (BCT) installed in New Norcia (Australia). These results demonstrate the potential of carefully selected P-band PSs to complement dedicated calibration infrastructure for relative radiometric monitoring and the detection of processing anomalies.

0.30