CS Paper Radar

Looping Kooshball: Improved k-space coverage for silent fMRI using 3D coherence trajectories

David J. Frey, Shreya Ramachandran, Jeffrey A. Fessler, Douglas C. Noll, Tobias C. Wood

eess.IV ·submitted 2026-10-27 23:41 UTC · v1

Abstract

Functional MRI (fMRI) is widely used to characterize brain activity and connectivity, but conventional gradient-echo echo-planar imaging produces high acoustic sound-pressure levels by operating gradient hardware near its limits. Scanner noise can increase anxiety and motion, particularly in noise-sensitive populations, and can evoke auditory responses that confound both task-based and resting-state measurements. Looping Star (LS) is a near-silent, T2*-weighted acquisition that uses slowly varying gradients and multiplexed, temporally staggered coherences. Conventional LS rotates planar encoding trajectories across shots to achieve three-dimensional coverage. Because these planes intersect near the center of k-space, sampling is dense at low spatial frequencies but sparse and nonuniform at the periphery, limiting efficiency when relatively few shots are combined for high temporal resolution. We introduce Looping Kooshball (LKB), a complementary LS trajectory that extends through all three spatial dimensions within each shot. LKB is designed to improve volumetric k-space coverage while preserving the echo-formation and coherence-crushing properties of LS. We compare LKB with conventional LS using point-spread-function analysis, in-bore acoustic measurements, structural phantom imaging, and preliminary visual-motor fMRI experiments. We evaluate whether LKB reduces undersampling artifacts and improves temporal stability and functional-activation detection without sacrificing the near-silent operation of LS.

Comment
11 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

DTI-Guided Volumetric Spherical Harmonics Regression for Single-to-Multi-Shell dMRI Synthesis

cs.CV ·2026-09-13 ·Binghua Li, Christina Andica, Tong Liang, Ziqing Chang, Chao Li +6 more
top venuecode/data similarity 0.59
Abstract · 10 pages, 4 figures. Accepted at MICCAI 2026

Multi-shell diffusion MRI (dMRI) unlocks more expressive microstructural modeling than single-shell scans, yet its longer acquisition time hinders deployment in large-scale cohorts and time-constrained clinical settings. Synthesizing an unobserved shell from a single-shell input is fundamentally ill-posed and further complicated by protocol mismatch, where source and target gradient direction sets may not align. We propose DTI-SHNet, a single-to-multi-shell synthesis framework that operates in the real symmetric spherical harmonics (SH) coefficient domain and performs spatially aware volumetric regression. Given a source shell, we estimate diffusion tensor imaging (DTI) and use direction-agnostic parametric maps along with a brain mask as conditioning priors to guide a 3D U-Net regressor from source-shell to target-shell SH coefficients. To couple coefficient accuracy with signal fidelity, we introduce a signal consistency regularization that reconstructs signals on randomly sampled canonical directions from predicted coefficients and enforces agreement in the signal domain. Experiments on UK Biobank and Cam-CAN data for b=1000 to b=2000 dMRI synthesis show that DTI-SHNet achieves competitive visual quality compared to advanced methods, while better preserving downstream diffusion measures. Our code is available at https://github.com/xiaovhua/dti-shnet.

0.51

Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTI

eess.SP ·2026-11-01 ·Yimeng Lin, Zachary Shah, Mehdi Khalighi, Zimu Huo, Mengze Gao +12 more
similarity 0.59
Abstract · 8 pages, 5 figures

High-performance head-only gradient systems can substantially reduce echo spacing (ESP) in echo-planar imaging (EPI), but the resulting encoding speed is typically used to shorten readouts and reduce distortion. Here, we instead leverage the increased echo budget to enable denser k-space sampling and higher simultaneous-multislice (SMS) acceleration in SMS-EPI and SMS-EPTI. Fast k-space traversal with denser ky-kz sampling is achieved using peripheral nerve stimulation (PNS)-optimized gradient waveforms, while high-quality reconstruction is obtained using field-correcting GRAPPA (FCG). The resulting ESPs on MAGNUS 3T and Impulse 7T are approximately half those of high-performance whole-body systems, enabling approximately 2-fold higher multiband (MB) acceleration. This facilitates high-quality 2.5-mm isotropic whole-brain resting-state fMRI at 7T with MB28 and a repetition time (TR) of 123 ms.

0.39

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

cs.CV ·2026-09-21 ·Jingran Xu, Dong Liang, Hairong Zheng, Yuanyuan Liu, Yanjie Zhu
similarity 0.58
Abstract

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.

0.12

Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis

cs.CV ·2026-10-07 ·Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu +1 more
top venue similarity 0.57
Abstract · Accepted to ECCV 2026

Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value of multi-contrast imaging. This motivates synthesizing missing contrasts from those already acquired, which is an inherently 3D problem requiring anatomical coherence across axial, sagittal, and coronal planes. However, fully 3D generative models are often impracti- cal under computational resources that scale cubically with volume size. We propose a unified Multi-Plane Autoregressive Diffusion (MPAD), a latent diffusion framework that achieves full-volume 3D synthesis using efficient plane-wise 2D operations while preserving volumetric coherence. A 3D autoencoder first compresses MRI scans into an isotropic 3D la- tent representation. A 2D diffusion model is then trained to reconstruct masked latent slices of the target contrast, conditioned on both source- contrast slices and unmasked target-contrast slices. During inference, we introduce plane-wise autoregressive synthesis with inter-plane priors. Slices are generated autoregressively in random order within one plane orientation to maintain intra-plane continuity, then propagated as con- ditioning priors to orthogonal plane orientations to enforce inter-plane consistency. Compared to 3D latent diffusion baselines, MPAD reduces training and inference FLOPs by 7x and 3x, respectively, while also lowering inference time and peak memory consumption. Experiments on multiple datasets demonstrate that MPAD achieves superior perfor- mance, generating high-fidelity 3D volumes and supporting one-to-many translation within a single unified model.

0.33

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.56
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17

Learning Where and How Much to Sample: Volume-Adaptive k-Space Acquisition for Accelerated MRI

cs.CV ·2026-11-18 ·Reyhaneh Neshatavar, Mohsen Yavartanoo, Kyoung Mu Lee
similarity 0.56
Abstract

Magnetic resonance imaging (MRI) is an essential medical imaging technique, but its high costs and long acquisition times can limit accessibility. Accelerated MRI reduces acquisition time through k-space undersampling, yet conventional methods often rely on predefined sampling patterns and uniform slice budgets, overlooking anatomical variations and inter-slice relationships. In this paper, we propose a volume-adaptive k-space acquisition framework that jointly learns where and how much to sample across an entire MRI volume. Using only acquired auto-calibration signal (ACS) measurements, our method exploits volume-wide anatomical information to adaptively allocate sampling budgets across slices while identifying informative k-space lines. A learned joint slice--frequency refinement module coordinates sampling decisions while preserving an exact total volume-level acquisition budget. To reconstruct the acquired measurements, we design a sensitivity-aware synchronous cross-slice reconstruction network that estimates coil sensitivities from ACS measurements and progressively refines neighboring-slice reconstructions while enforcing hard k-space data consistency. Both networks are jointly optimized using reconstruction-based supervision without requiring fully sampled k-space at inference. Experiments on knee and brain MRI across multiple contrasts and acceleration factors demonstrate the adaptive behavior of our acquisition framework and evaluate its reconstruction performance.

0.17

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

cs.AI ·2026-11-09 ·Juan Liu, Nian Wang
similarity 0.55
Abstract · Submit to a journal; under review

Purpose: To develop a phase-aware self-supervised framework for accelerated high-resolution multi-echo gradient-echo (mGRE) MRI that preserves anatomical detail and complex echo information for quantitative mapping. Methods: We developed multi-stage phase-aware self-supervised reconstruction (MSPR-GRE), integrating progressive k-space expansion with phase estimation and refinement. Sequential unrolled networks reconstruct complex multi-echo images and update echo-dependent phase priors. A relaxation-informed temporal subspace is used for acquisitions with at least four echoes, while shorter echo trains are reconstructed in the image domain. Training uses held-out acquired k-space samples without fully sampled targets. Evaluation included 9.4 T ex vivo mouse-brain data 30um eight-echo and 18um dual-echo) and retrospectively undersampled 7 T AHEAD human-brain data, with supervised ablations. Results:MSPR-GRE reduced artifacts in regions of rapid phase variation and preserved fine mouse-brain anatomy. Across five AHEAD test datasets at R = 4, 8, and 12, it generally improved magnitude-image, T2* map, and QSM metrics, particularly at higher acceleration. At R = 12, fourth-echo magnitude NRMSE was 12.09$\pm$0.60% versus 21.55$\pm$1.12% for SSDU. Ablations indicated benefits of phase refinement, while supervised experiments supported multi-stage phase-aware reconstruction. Conclusion: MSPR-GRE improves accelerated mGRE reconstruction and quantitative-map agreement without fully sampled training targets. Further validation of generalizability and phase-estimation accuracy is needed.

0.17

Array-Agnostic High-Order Ambisonics Encoding via Diffusion Posterior Sampling

eess.AS eess.SP ·2026-10-29 ·Amit Milstein, Nir Shlezinger, Boaz Rafaely
similarity 0.55
Abstract

Ambisonics provides a device-independent representation of three-dimensional sound fields; however, extracting these coefficients from practical microphone array recordings remains strongly dependent on array geometry, acoustic transfer functions, and spatial sampling resolution. This pipeline is typically divided into two distinct tasks: encoding, which entails reconstructing the physically resolvable spatial components, and upscaling, which requires generating higher-order coefficients. Model-based approaches often fail on irregular arrays due to ill-conditioned transfer matrices, whereas conventional neural encoders remain strictly tied to the specific acquisition setup seen during training. Furthermore, existing upscaling methods usually assume ideal low-order inputs, ignoring device-specific array artifacts. We present ADEUPS, a unified framework that couples an array-independent Ambisonic diffusion prior with an explicit physical acquisition model during inference, enabling zero-shot encoding and upscaling across diverse array configurations. We train our prior using an order-masking strategy and perform inference via score blending, which we demonstrate to be crucial for solving the underlying inverse problem. Through extensive numerical evaluations across various array geometries, we show that ADEUPS consistently outperforms task- and array-specific baselines. Finally, we conduct subjective listening tests to confirm the perceptual effectiveness of our approach.

0.12