CS Paper Radar

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

Juan Liu, Nian Wang

cs.AI ·submitted 2026-11-09 23:25 UTC · v1

Abstract

Purpose: To develop a phase-aware self-supervised framework for accelerated high-resolution multi-echo gradient-echo (mGRE) MRI that preserves anatomical detail and complex echo information for quantitative mapping. Methods: We developed multi-stage phase-aware self-supervised reconstruction (MSPR-GRE), integrating progressive k-space expansion with phase estimation and refinement. Sequential unrolled networks reconstruct complex multi-echo images and update echo-dependent phase priors. A relaxation-informed temporal subspace is used for acquisitions with at least four echoes, while shorter echo trains are reconstructed in the image domain. Training uses held-out acquired k-space samples without fully sampled targets. Evaluation included 9.4 T ex vivo mouse-brain data 30um eight-echo and 18um dual-echo) and retrospectively undersampled 7 T AHEAD human-brain data, with supervised ablations. Results:MSPR-GRE reduced artifacts in regions of rapid phase variation and preserved fine mouse-brain anatomy. Across five AHEAD test datasets at R = 4, 8, and 12, it generally improved magnitude-image, T2* map, and QSM metrics, particularly at higher acceleration. At R = 12, fourth-echo magnitude NRMSE was 12.09$\pm$0.60% versus 21.55$\pm$1.12% for SSDU. Ablations indicated benefits of phase refinement, while supervised experiments supported multi-stage phase-aware reconstruction. Conclusion: MSPR-GRE improves accelerated mGRE reconstruction and quantitative-map agreement without fully sampled training targets. Further validation of generalizability and phase-estimation accuracy is needed.

Comment
Submit to a journal; under review

Closest papers

Nearest neighbours by meaning across the whole index.

MOSAIC: A Self-supervised Dynamic Multi-encoding Reconstruction Framework for 3D Late Gadolinium Enhancement MRI

eess.IV ·2026-08-19 ·Muhammad A. Sultan, Yingmin Liu, Katherine Binzel, Katarzyna E. Gil, Karolina M. Zareba +1 more
similarity 0.66
Abstract

Purpose: To develop and evaluate a self-supervised dynamic reconstruction framework for highly undersampled dual-echo three-dimensional late gadolinium enhancement (3D LGE) MRI. Methods: MOSAIC jointly models multi-echo image content, coil sensitivity maps, and beat-specific nonrigid motion directly from acquired undersampled data, without requiring fully sampled training datasets or accurate precomputed sensitivity maps. Unlike existing methods that bin the acquired data into different motion states, with or without motion compensation, MOSAIC reconstructs a motion-resolved 3D LGE image from each heartbeat. The method was evaluated using digital phantoms with simulated myocardial scars and in vivo animal and human studies. Results: In phantom experiments, MOSAIC achieved higher peak signal-to-noise ratio and structural similarity index measure than low-rank deep image prior reconstruction and ablation variants of MOSAIC. In animal and human studies, MOSAIC achieved higher blinded expert image-quality scores than inline image-navigated compressed-sensing and low-rank deep image prior reconstructions. Conclusion: MOSAIC demonstrated the feasibility of motion-resolved free-breathing dual-echo 3D LGE MRI at acceleration factors exceeding 1,000, with improved detail preservation and artifact suppression relative to the state-of-the-art comparison methods.

0.36

UMPIRE-Net: Unrolled Magnitude-Phase Regularization Network for Accelerated MRI

eess.IV cs.CVeess.SPphysics.med-ph ·2026-08-14 ·Mahdi Saberi, Toygan Kiliç, Mehmet Akçakaya
code/data similarity 0.66
Abstract · IEEE International Workshop on Machine Learning for Signal Processing (MLSP)

MRI reconstruction from undersampled k-space measurements is an ill-posed inverse problem. Physics-driven deep learning (PD-DL) methods have shown strong performance for this task by combining the MRI forward model with learned image regularization within algorithm-unrolling frameworks. However, most existing PD-DL methods reconstruct complex-valued images directly, thereby implicitly coupling magnitude and phase within a single learned representation. This coupled regularization may be suboptimal in reconstruction settings where accurate phase modeling plays an important role, such as partial Fourier (PF) imaging, where recovery of the omitted asymmetric k-space measurements depends on the underlying image phase. In such scenarios, explicit modeling of magnitude and phase as separate components may reduce the reliance on externally estimated or predefined phase information. To this end, we propose UMPIRE-Net (Unrolled Magnitude-Phase In REgularization Network), a PD-DL method that introduces separate learned regularizers for magnitude and phase components, together with a novel data-fidelity formulation that enforces measurements consistency. We evaluate UMPIRE-Net for accelerated MRI with PF across different datasets and acceleration factors. Experimental results demonstrate that our proposed method improves reconstruction quality compared with a conventional complex-valued PD-DL baseline, yielding sharper images and reduced artifacts. Code available at: https://github.com/MahdiSaberii/UMPIRE-Net

0.59

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
similarity 0.66
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.24

Hankel Subspace Self-Supervised Learning for Parallel MRI Reconstruction

cs.CV ·2026-10-08 ·Mingyu Hu, Siquan Zhu, Xijun Zhong, Qiegen Liu
similarity 0.64
Abstract

Parallel magnetic resonance imaging reconstruction is an ill-posed inverse problem under undersampling. Multi-coil acquisition and Hankel lifting expose complementary repeated information: observations of the same anatomy across coils and repeated local k-space neighborhoods in overlapping windows. These dependencies guide recovery of missing k-space data. However, splitting lifted Hankel entries for self-supervision can place the original sample in both input and target, causing data leakage. We propose Hankel Subspace Self-Supervised Reconstruction (HSSRecon), a scan-specific reconstruction framework for parallel magnetic resonance imaging. HSSRecon partitions data by physical acquisition units before Hankel lifting and applies multiplicity normalization to repeated Hankel copies in overlapping windows. Rather than learning a mapping that directly predicts missing data, the network learns a compact complex-valued Hankel subspace operator. Reconstruction is performed over the original k-space variables using a conjugategradient solver with hard data consistency. This design separates structural learning in the Hankel domain from data consistency in the physical domain: the former exploits multi-coil and local Hankel correlations, while the latter solves over unacquired degrees of freedom. We provide theoretical analyses of physicalgroup splitting and multiplicity normalization, and establish positive definiteness, uniqueness, hard data consistency, and a finite-step conjugate-gradient error bound for the system. On fastMRI brain data with three contrasts and three sampling masks, HSSRecon achieves competitive peak signal-to-noise ratio, structural similarity, and normalized mean squared error across six aggregated conditions.

0.16

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

cs.CV ·2026-09-21 ·Jingran Xu, Dong Liang, Hairong Zheng, Yuanyuan Liu, Yanjie Zhu
similarity 0.63
Abstract

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.

0.12

LGGS: Longitudinal MRI Reconstruction via Guided Group Sparsity

eess.IV cs.CV ·2026-10-15 ·Nikola Janjušević, Hersh Chandarana, Yao Wang, Li Feng
similarity 0.63
Abstract · 10 pages main, 8 figures main, 5 pages supplementary, 7 figures supplementary

Serial MRI is routinely performed in current clinical practice for disease surveillance and applications such as MR-guided radiotherapy. However, long MRI scan times increase costs and limit patient access, making accelerated image reconstruction of broad clinical importance. Previous scans of the same patient contain image information highly correlated with the current exam, yet existing reconstruction methods rarely exploit this information. Major challenges in the effective use of prior scans include inter-visit misregistration, pathological changes, and image phase variation. In this work, we propose Longitudinal Guided Group Sparsity (LGGS), an interpretable deep-learning framework for longitudinally informed MRI reconstruction derived from classical group sparsity. The prior scan is incorporated into the reconstruction regularizer through learned phase-invariant circulant attention that identifies corresponding features across exams. This formulation provides robustness to local in-plane and through-plane misregistration as well as inter-visit phase variation. Across acceleration rates, LGGS achieves state-of-the-art performance on longitudinal T1-weighted multi-coil brain MRI data, outperforming the evaluated unguided and longitudinally informed reconstruction methods, with substantially fewer learned parameters. We further evaluated the contributions of multiple guide slices and phase-invariant similarity and demonstrated that accelerated prior images can also serve as effective guides with minimal degradation in reconstruction quality.

0.21

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.62
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17

MnemoDyn: Learning Resting State Dynamics from 40K FMRI sequences

cs.LG ·2026-08-25 ·Sourav Pal, Viet Luong, Hoseok Lee, Tingting Dan, Guorong Wu +3 more
published similarity 0.62
Abstract · ICLR 2026

We present a dynamical-systems based model for resting-state functional magnetic resonance imaging (rs-fMRI), trained on a dataset of roughly 40K rs-fMRI sequences covering a wide variety of public and available-by-permission datasets. While most existing proposals use transformer backbones, we utilize multi-resolution temporal modeling of the dynamics across parcellated brain regions. We show that MnemoDyn is compute efficient and generalizes very well across diverse populations and scanning protocols. When benchmarked against current state-of-the-art transformer-based approaches, MnemoDyn consistently delivers superior reconstruction quality. Overall, we find that with such large-scale pre-training on (non-proprietary) rs-fMRI datasets, we get a highly performant model for various downstream tasks. Our results also provide evidence of the efficacy of the model on small sample size studies which has implications for neuroimaging studies at large where resting state fMRI is a commonly acquired imaging modality.

0.52