CS Paper Radar

Leveraging high-performance head-only gradients to enable ~2-fold higher multiband acceleration in SMS-EPI and SMS-EPTI

Yimeng Lin, Zachary Shah, Mehdi Khalighi, Zimu Huo, Mengze Gao, Hua Wu, Baolian Yang, Qiang Liu, Erpeng Dai, Arthur Chakwizira, Lipeng Ning, Carl-Fredrik Westin, Yogesh Rathi, Jonathan R. Polimeni, Nan Wang, Adam B. Kerr, Kawin Setsompop

eess.SP ·submitted 2026-11-01 01:22 UTC · v1

Abstract

High-performance head-only gradient systems can substantially reduce echo spacing (ESP) in echo-planar imaging (EPI), but the resulting encoding speed is typically used to shorten readouts and reduce distortion. Here, we instead leverage the increased echo budget to enable denser k-space sampling and higher simultaneous-multislice (SMS) acceleration in SMS-EPI and SMS-EPTI. Fast k-space traversal with denser ky-kz sampling is achieved using peripheral nerve stimulation (PNS)-optimized gradient waveforms, while high-quality reconstruction is obtained using field-correcting GRAPPA (FCG). The resulting ESPs on MAGNUS 3T and Impulse 7T are approximately half those of high-performance whole-body systems, enabling approximately 2-fold higher multiband (MB) acceleration. This facilitates high-quality 2.5-mm isotropic whole-brain resting-state fMRI at 7T with MB28 and a repetition time (TR) of 123 ms.

Comment
8 pages, 5 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Multi-Stage Phase-Aware Self-Supervised Reconstruction for Multi-Echo Gradient-Echo MRI

cs.AI ·2026-11-09 ·Juan Liu, Nian Wang
similarity 0.59
Abstract · Submit to a journal; under review

Purpose: To develop a phase-aware self-supervised framework for accelerated high-resolution multi-echo gradient-echo (mGRE) MRI that preserves anatomical detail and complex echo information for quantitative mapping. Methods: We developed multi-stage phase-aware self-supervised reconstruction (MSPR-GRE), integrating progressive k-space expansion with phase estimation and refinement. Sequential unrolled networks reconstruct complex multi-echo images and update echo-dependent phase priors. A relaxation-informed temporal subspace is used for acquisitions with at least four echoes, while shorter echo trains are reconstructed in the image domain. Training uses held-out acquired k-space samples without fully sampled targets. Evaluation included 9.4 T ex vivo mouse-brain data 30um eight-echo and 18um dual-echo) and retrospectively undersampled 7 T AHEAD human-brain data, with supervised ablations. Results:MSPR-GRE reduced artifacts in regions of rapid phase variation and preserved fine mouse-brain anatomy. Across five AHEAD test datasets at R = 4, 8, and 12, it generally improved magnitude-image, T2* map, and QSM metrics, particularly at higher acceleration. At R = 12, fourth-echo magnitude NRMSE was 12.09$\pm$0.60% versus 21.55$\pm$1.12% for SSDU. Ablations indicated benefits of phase refinement, while supervised experiments supported multi-stage phase-aware reconstruction. Conclusion: MSPR-GRE improves accelerated mGRE reconstruction and quantitative-map agreement without fully sampled training targets. Further validation of generalizability and phase-estimation accuracy is needed.

0.17

Looping Kooshball: Improved k-space coverage for silent fMRI using 3D coherence trajectories

eess.IV ·2026-10-27 ·David J. Frey, Shreya Ramachandran, Jeffrey A. Fessler, Douglas C. Noll, Tobias C. Wood
similarity 0.59
Abstract · 11 pages, 5 figures

Functional MRI (fMRI) is widely used to characterize brain activity and connectivity, but conventional gradient-echo echo-planar imaging produces high acoustic sound-pressure levels by operating gradient hardware near its limits. Scanner noise can increase anxiety and motion, particularly in noise-sensitive populations, and can evoke auditory responses that confound both task-based and resting-state measurements. Looping Star (LS) is a near-silent, T2*-weighted acquisition that uses slowly varying gradients and multiplexed, temporally staggered coherences. Conventional LS rotates planar encoding trajectories across shots to achieve three-dimensional coverage. Because these planes intersect near the center of k-space, sampling is dense at low spatial frequencies but sparse and nonuniform at the periphery, limiting efficiency when relatively few shots are combined for high temporal resolution. We introduce Looping Kooshball (LKB), a complementary LS trajectory that extends through all three spatial dimensions within each shot. LKB is designed to improve volumetric k-space coverage while preserving the echo-formation and coherence-crushing properties of LS. We compare LKB with conventional LS using point-spread-function analysis, in-bore acoustic measurements, structural phantom imaging, and preliminary visual-motor fMRI experiments. We evaluate whether LKB reduces undersampling artifacts and improves temporal stability and functional-activation detection without sacrificing the near-silent operation of LS.

0.33

SGAM: Shared Gaussian Geometry with Implicit Amplitude Modeling for Scan-Specific 3D Multi-Contrast MRI Reconstruction

cs.CV ·2026-09-21 ·Jingran Xu, Dong Liang, Hairong Zheng, Yuanyuan Liu, Yanjie Zhu
similarity 0.56
Abstract

Three-dimensional (3D) multi-contrast magnetic resonance imaging (MCMRI) provides rich anatomical and quantitative information but requires long acquisition times, motivating k-space undersampling. However, reconstruction of large volumetric datasets imposes substantial computational and memory demands. To address this challenge, we propose SGAM, a memory-efficient, scan-specific framework for joint full-volume 3D MCMRI reconstruction. SGAM is based on a shared-geometry Gaussian representation in which amplitudes are modeled by a multi-output implicit neural representation (INR) and contrast-specific phases by explicit variables. This design exploits common anatomical structure across contrasts while preserving contrast-specific signal variations. The representation is jointly optimized using only the acquired multi-coil k-space without external training data. Experiments showed that SGAM consistently outperformed the comparison methods across imaging tasks and acceleration factors, with greater improvements under stronger undersampling. SGAM also achieved a favorable balance between reconstruction quality and computational cost, demonstrating its effectiveness for 3D multi-contrast MRI reconstruction.

0.12

Unified Motion Correction and Reconstruction for Accelerated Zero Echo Time MRI

eess.IV ·2026-11-03 ·Yan Chen, Curtis A. Corum, James H. Holmes, Mathews Jacob
similarity 0.55
Abstract

Zero echo time (ZTE) MRI is near-silent, but dead time gaps, head motion, and undersampling jointly degrade reconstruction. To develop an accelerated ZTE MRI reconstruction framework that jointly estimates the 3D image and rigid-motion parameters, this work introduces Energy-based Motion Correction (EnMoCo), a regularized maximum a posteriori (MAP) formulation that also compensates for missing k-space center data and angular undersampling artifacts. Solved by alternating between k-space rigid-motion updates and conjugate-gradient data-consistency updates, the framework incorporates regularization via a pre-trained Multi-Scale Energy-based model (MuSE) implemented in a data-efficient 2.5D form. Evaluations on simulated and in vivo 3D ZTE data, spanning dead time gaps of 1.5 to 5 samples, rotations up to 17 degrees and translations up to 10 mm, demonstrate that EnMoCo significantly improves PSNR and SSIM relative to CG-SENSE and Autofocusing baselines (achieving roughly 10 to 15 dB higher PSNR for gaps >= 3.5) while reducing motion blur and tissue contrast inconsistencies.

0.24

FESTiVE: Self-calibrated Spatial-temporal Gradient Characterization for Non-cartesian Imaging on High Performance Systems

eess.SP ·2026-10-30 ·Zachary Shah, Daniel R. Abraham, Nan Wang, Xiaozhi Cao, Qiang Liu +9 more
similarity 0.53
Abstract

Gradient imperfections disrupt the encoding benefits of long-readout imaging applications on high-performance systems. Currently, external field monitoring hardware provides the only reliable solution for general spatial-temporal gradient characterization. We present FESTiVE, a data-driven alternative to higher-order field monitoring. FESTiVE leverages parallel imaging to both implicitly model and explicitly recover field imperfections. Using a fast k-t mapping calibration scan, FESTiVE formulates a time-varying GRAPPA problem which maps k-space data corrupted by a time-varying gradient imperfection against a clean reference. This mapping is represented compactly with an implicit neural representation, from which the spatial-temporal fields are recovered in image space using coil sensitivities. In phantom, FESTiVE produces comparable field measurements to a Skope field camera across multiple non-cartesian 2D acquisition strategies and gradient specifications. In vivo, FESTiVE achieves state-of-the-art image quality for a high-performance diffusion spiral protocol on the head-only MAGNUS 3T, where higher-order phase imperfections are significant. At 7T, on the head-only Siemens TerraX system, FESTiVE enables 300μm spiral imaging where conventional field camera-based approaches fall below probe dephasing limits. In conclusion, FESTiVE enables robust high-resolution non-cartesian imaging on high-performance gradients, characterizing gradient imperfections using parallel imaging rather than field monitoring hardware.

0.28

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.53
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

D-MOD: Diffusion mode estimation for accelerated MRI

cs.LG ·2026-10-29 ·Md Kawsar Ahmed, Mathews Jacob
theory similarity 0.51
Abstract

Diffusion models are powerful priors for accelerated MRI reconstruction, but most current methods are posterior samplers, which return a random draw from the posterior. A reproducible and high-quality reconstruction often requires averaging many samples, resulting in a high computational cost. We introduce D-MOD, a fast algorithm that instead provides a posterior mode. It uses a minorize-maximize algorithm on a lower bound of the smoothed log-posterior, which provably increases the objective. Each iteration draws S noisy samples of the current estimate at the current noise level, denoises them with a pretrained diffusion model, and combines their average with the measured k-space through a conjugate-gradient (CG) solve. We anneal the noise levels, as the distance between the bound and its target decays quadratically with noise. On fastMRI brain (T1, T2, FLAIR), a single D-MOD reconstruction exceeds, in PSNR, the 10-sample finite-MMSE estimates of DPS, DAPS and SNORE-P and stays within 0.31 dB of the strongest baselines (DiffPIR, DDS). This approach thus provides a fast deterministic reconstruction algorithm (11-73 times faster than MMSE estimates), which is useful in a clinical setting.

0.36

AGGR-Mamba: Mamba-based Network with Attention-Guided Gated Residual Refinement for Undersampled MRI Reconstruction

cs.CV ·2026-10-20 ·Yue Zhuo, Wenbin Deng, Lingjun Liu, Xuhang Chen, Zhonghua Xie
published similarity 0.51
Abstract · Accepted by IEEE BIBM 2026

Undersampled magnetic resonance imaging (MRI) reconstruction aims to recover high-quality images from partially acquired k-space data, thereby reducing scan time. However, missing frequency-domain measurements often lead to residual aliasing artifacts, blurred edges, and loss of local structural details. In this paper, we propose AGGR-Mamba, a lightweight output-stage residual refinement method built upon a Mamba backbone for undersampled brain MRI reconstruction. The Mamba backbone first produces an initial reconstruction, and the proposed refinement modules then correct the remaining local errors and high-frequency artifacts in a controlled residual manner. Specifically, an Attention Refine Head is introduced to recalibrate local anatomical structures, edge textures, and residual-error regions through channel and spatial attention. In addition, a GDFN-style gated residual refinement branch is designed to selectively preserve informative residual features while suppressing redundant or unstable responses. By combining attention-based recalibration with gated residual selection, AGGR-Mamba improves local structure recovery without substantially disturbing the backbone reconstruction. Experiments are conducted on the IXI brain MRI dataset with T1- and T2-weighted images under acceleration factors of R=4 and R=8. The results show that AGGR-Mamba achieves competitive PSNR and SSIM performance across different reconstruction settings, demonstrating the effectiveness of the proposed output-stage refinement strategy.

0.36