CS Paper Radar

AGGR-Mamba: Mamba-based Network with Attention-Guided Gated Residual Refinement for Undersampled MRI Reconstruction

Yue Zhuo, Wenbin Deng, Lingjun Liu, Xuhang Chen, Zhonghua Xie

cs.CV ·submitted 2026-10-20 14:39 UTC · v1
published

Abstract

Undersampled magnetic resonance imaging (MRI) reconstruction aims to recover high-quality images from partially acquired k-space data, thereby reducing scan time. However, missing frequency-domain measurements often lead to residual aliasing artifacts, blurred edges, and loss of local structural details. In this paper, we propose AGGR-Mamba, a lightweight output-stage residual refinement method built upon a Mamba backbone for undersampled brain MRI reconstruction. The Mamba backbone first produces an initial reconstruction, and the proposed refinement modules then correct the remaining local errors and high-frequency artifacts in a controlled residual manner. Specifically, an Attention Refine Head is introduced to recalibrate local anatomical structures, edge textures, and residual-error regions through channel and spatial attention. In addition, a GDFN-style gated residual refinement branch is designed to selectively preserve informative residual features while suppressing redundant or unstable responses. By combining attention-based recalibration with gated residual selection, AGGR-Mamba improves local structure recovery without substantially disturbing the backbone reconstruction. Experiments are conducted on the IXI brain MRI dataset with T1- and T2-weighted images under acceleration factors of R=4 and R=8. The results show that AGGR-Mamba achieves competitive PSNR and SSIM performance across different reconstruction settings, demonstrating the effectiveness of the proposed output-stage refinement strategy.

Comment
Accepted by IEEE BIBM 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Anatomically Faithful Artifact Suppression in SENSE Accelerated Brain MRI

eess.IV cs.CV ·2026-09-18 ·Changjing Chai, Bin Huang, Libo Xu, Jian Zhou, Boyang Pan +3 more
similarity 0.70
Abstract · 18 pages of main text, 2 pages of appendix, 6 figures, and 6 tables (including 2 appendix tables)

Background: Four-fold accelerated sensitivity encoding (SENSE4) can shorten brain MRI acquisition time but may amplify noise and result in residual aliasing artifacts after conventional reconstruction. Purpose: To evaluate whether an image-domain refinement framework can improve the quality of SENSE4 brain MRI while preserving anatomical information for quantitative measurements. Methods: In this prospective paired study, 80 participants underwent fully sampled and four-fold accelerated SENSE T1-weighted MRI. We developed an Anatomy-aware Residual Attention Network (ART-Net) to refine accelerated reconstructions through generalized self-attention and correlation-based residual artifact regularization. Participant-level splitting yielded training, validation, and independent test cohort (45/5/30 participants). The independent test cohort underwent quantitative, segmentation-based, and blinded radiologist assessments of image quality and anatomical preservation. Results: ART-Net demonstrated highly competitive reconstruction performance, achieving the highest peak signal-to-noise ratio (31.03 +/- 2.88 dB) and structural similarity index (0.963 +/- 0.022) among evaluated methods. It also demonstrated improved anatomical fidelity, with numerically highest Dice coefficients for medial temporal structures relevant to atrophy assessment (0.8824 +/- 0.0827) and whole-brain regions (0.8857 +/- 0.0885). Moreover, ART-Net improved gradient fidelity, regional contrast preservation, and radiologist-rated structural quality. Conclusion: ART-Net improved agreement between SENSE4 and fully sampled T1-weighted images in a single-center, held-out test cohort while maintaining segmentation-derived anatomical measurements. These findings suggest that ART-Net may support accelerated brain MRI by improving image fidelity and enabling reliable downstream anatomical analysis.

0.23

Data-Efficient Networks for Multi-Contrast MRI Reconstruction based on a Generalized Content/Style Prior

eess.IV cs.CV ·2026-09-02 ·Chinmay Rao, Efe Ilıcak, Matthias J. P. van Osch, Mariya Doneva, Laurens Beljaards +3 more
similarity 0.62
Abstract

Multi-contrast MR scans contain redundant structural information that can be leveraged during reconstruction and potentially accelerate acquisition times. This idea has inspired end-to-end guided reconstruction models, leveraging one or more contrasts to guide the reconstruction of a different contrast. However, these models require large paired multi-contrast raw datasets for training, limiting their application in low-data regimes. In this work, we propose a modular framework, namely CoSMo-RecNet, for learning guided reconstruction models in the low-data regime. At its core is a reusable multi-contrast representation based on a content/style model, which can be learned from large-scale, publicly accessible, unpaired multi-contrast image datasets, without available k-space data. Using this frozen model as a multi-contrast prior and using a set of reference contrasts, the reconstruction problem reduces to a much simpler refinement problem that can be solved by a lightweight unrolled network and thus learned from small, task-specific reconstruction datasets. We demonstrate the efficacy of CoSMo-RecNet by evaluating it on the low-field 0.3 T M4Raw dataset, showing stable reconstruction quality on decreasing the raw training data budget. CoSMo-RecNet achieved higher reconstruction quality with 5 training subjects or lower compared to a parameter-count-matched MoDL trained on 100 subjects. On a data-limited and severely out-of-distribution ultra-low-field 47 mT Halbach scanner dataset, CoSMo-RecNet was superior to other viable strategies, including classical reconstruction, transfer learning, and zero-shot reconstruction.

0.28

DGCM-SSFA: Dual-Granularity Cross-Modulation and Sparse Strip Frequency Attention for Efficient 3T-to-7T MRI Synthesis

cs.CV ·2026-10-21 ·Zhichun Fan, Zhiqiang Chen, Lanling Liu, Lingjun Liu, Zhonghua Xie
publishedbenchmarkhot direction similarity 0.62
Abstract · Accepted by BIBM 2026

Synthesizing high-fidelity 7T MRI from routinely acquired 3T scans offers a practical pathway to enhanced neuroimaging without the prohibitive cost of ultra-high-field scanners. While existing deep learning approaches have achieved promising results, state-of-the-art methods typically rely on either large-scale architectures exceeding 45 million parameters or computationally intensive ensemble strategies, limiting their practicality in resource-constrained clinical environments. In this work, we propose a compact multi-domain attention framework, termed DGCM-SSFA, that achieves competitive synthesis quality with only 11M parameters. The proposed architecture integrates two complementary modules into a U-Net Transformer backbone. First, a Dual-Granularity Cross-Modulated Feature Modulator (DGCM) is embedded at multiple hierarchical levels to enhance local edge and texture details through Sobel-guided spatial attention and depthwise frequency-aware channel attention with cross-branch gating. Second, a Sparse Strip Frequency Attention (SSFA) module at the bottleneck captures global spatial context via strip-pooled attention with near-linear complexity, while simultaneously performing FFT-based spectral modulation in the frequency domain. These two modules operate synergistically with the backbone's native channel attention, forming a triple-granularity feature refinement pipeline. Extensive experiments on the UNC and BNU 3T-to-7T MRI datasets across T1w and T2w modalities demonstrate that DGCM-SSFA achieves strong structural fidelity, attaining an SSIM of 0.8431 on BNU T2w---approaching the best benchmark value of 0.8624---and 0.8100 on BNU T1w, while using substantially fewer parameters than Transformer-based alternatives such as ResViT (123.4M) and FS-RWKV (45.4M).

0.38

PGDM-MRSRGAN: Physics-Guided Degradation Model with an SRGAN Framework for Magnetic Resonance Image Super-Resolution: Applications in Low-Field MRI

eess.IV physics.med-ph ·2026-09-24 ·Yashwant Kurmi, Charlotte R. Sappo, Sai Abitha Srinivas, Selin D. Kandemir, Malvika Viswanathan +1 more
similarity 0.62
Abstract · 28 pages, 10 figures, 5 supporting information tables

Magnetic Resonance Imaging (MRI) often suffers from low signal-to-noise ratio (SNR) and limited spatial resolution, which compromise clinical precision. This study aims to address these challenges by developing a physics-guided degradation model (PGDM) and a novel deep learning framework, Magnetic Resonance Super-Resolution GAN Imaging (MRSRGAN), for improved super-resolution reconstruction of MRI images. The proposed approach consists of two stages: (1) a physics-guided degradation model that simulates low-field MRI conditions by incorporating artifacts such as blur, B0 inhomogeneity, chemical shift effects, down-sampling, and noise to generate paired low-resolution (LR) and high-resolution (HR) training datasets; and (2) an MRSRGAN-based reconstruction network utilizing a hybrid loss function, including modified spectral angle mapper (MSAM) and sharpened ground truth images based on de-convolution of slice profile-based kernels to restore high-SNR and high-resolution images. Experimental validation demonstrates that the proposed method achieves superior spatial resolution, enhanced SNR, improved peak signal-to-noise ratio (PSNR), higher structural similarity index (SSIM), reduced MSAM error, and better non-reference image quality evaluation (NIQE) metrics. Furthermore, it effectively reduces artifacts and demonstrates robustness on real MRI datasets. The MRSRGAN framework, guided by the physics-informed degradation model, provides a significant improvement in MRI image quality, enhancing spatial resolution and diagnostic accuracy. Its demonstrated robustness and effectiveness on real MRI datasets highlight its potential to resolution enhancement for precise diagnostic imaging.

0.27

Scalable Unrolled Chains for MRI Reconstruction

cs.CV ·2026-10-24 ·Emiljo Mëhillaj, Ender Konukoglu
publishedcode/data similarity 0.61
Abstract · 23 pages (including supplementary material), 14 figures. Accepted at WACV 2027

Unrolled variational networks achieve state-of-the-art performance for accelerated MRI reconstruction, but standard end-to-end training becomes prohibitively memory intensive as the number and width of cascades increase. We propose a memory-efficient training framework that updates a randomly sampled cascade while retaining supervision from the final reconstruction loss. The error signal is propagated from the end of the chain to the sampled cascade using an activation-light backward pass that avoids storing full chain activations, thereby decoupling training memory from chain length. A time-conditioned network shared across cascades further keeps the parameter count independent of chain length. The backward pass is approximate only through frozen normalization statistics, and a trained exact gradient control shows the approximation leaves reconstruction quality unchanged. The framework remains trainable at chain lengths and cascade widths where standard end-to-end backpropagation exhausts GPU memory. On fastMRI single-coil knee and multi-coil brain reconstruction, our method consistently outperforms other local training approaches. On high-SNR knee slices, our method surpasses E2E-VarNet at $8\times$ and matches it at $4\times$, while on the complete brain validation set it surpasses E2E-VarNet at $8\times$ and achieves comparable performance at $4\times$, with fewer parameters, lower peak memory, and faster per-iteration training. Code is available at https://github.com/emehillaj/scalable-unrolled-mri.

0.50

FM-Recon: Exploring Foundation Model Features for Accelerated Cardiac Cine MRI Reconstruction

cs.CV cs.AI ·2026-11-16 ·Donghang Lyu, Marius Staring, Ruochen Gao, Jochen Keupp, Hildo J. Lamb +1 more
similarity 0.60
Abstract

Foundation models have demonstrated strong feature extraction capabilities across various medical imaging tasks, yet their potential for MRI reconstruction remains largely unexplored, particularly within unrolled reconstruction networks and under artifact-corrupted inputs. In this work, we explore whether and how features from pretrained foundation models can benefit accelerated cardiac cine MRI reconstruction. To this end, we propose FM-Recon, a framework that refines and integrates extracted features from frozen image encoder of foundation models into an unrolled reconstruction network. Through extensive experiments on the CMRxRecon2023 dataset, we systematically evaluate foundation model features across different reconstruction settings. Our results show that foundation models can extract informative representations from artifact-corrupted inputs and improve reconstruction performance, particularly at moderate acceleration factors. These findings demonstrate the potential of foundation model features for accelerated MRI reconstruction and provide insights into their effective integration into unrolled reconstruction networks.

0.07

Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort

cs.CV ·2026-11-16 ·Kabir Hamzah Muhammad, Lorena Garcia-Foncillas Macias, Soumya Snigdha Kundu, Emily Guilhem, Jon Cleary +8 more
code/data similarity 0.60
Abstract · 27 pages, 14 figures

High-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved

0.51

Awaken, Then Scale: Tiny Adaptation for MRI Reconstruction

eess.IV cs.CV ·2026-09-25 ·Mohammed Wattad, Tamir Shor, Alexander M. Bronstein
similarity 0.60
Abstract

Dormant Awakening (DA) specializes a magnetic resonance imaging (MRI) reconstruction model by fitting a small set of zero weights to one labeled slice. Across fourteen U-shaped convolutional network (U-Net) and vision transformer (ViT) sources, fitting 1,004 or 10,560 weights gives mean peak signal-to-noise ratio (PSNR) gains of .430 and .509 dB. We analyze how scaling the fitted output correction changes evaluation PSNR, then use the calibration correction size to cap changes on new images. The cap bounds changes in root mean squared error (RMSE) relative to the source without an evaluation reference. At 10\% adaptation budget, we compare fixed halving and dynamic capping for DA, unrestricted sparse adaptation and low-rank adaptation (LoRA). The controls increase both measured calibration-evaluation correlations across all six tested architecture-adapter settings. Experiments concern one constructed fastMRI-to-M4Raw shift with fixed source checkpoints and participant panels.

0.19